K50PCLRGB7AQ
VISUAL SIGNAL INDICATOR UNITS
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 157.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
K50 Pro Compact with Audible Indicator ## Features 50 mm Compact Programmable Multicolor RGB Audible Indicator - Bright, uniform indicator light - • Designed with integrated audible alarm • Available for lower profile applications • Seven default colors in one device (Green, Red, Yellow, Blue, White, Cyan, Magenta) • Programmable using Banner's Pro Editor software and Pro Converter Cable • 30 mm threaded polycarbonate base • Translucent polycarbonate cover • Rugged IP67, IP69K per ISO 20653 and UL Type 4X and UL Type 13 design • Bimodal inputs (PNP/NPN), depending on source wiring • Variety of connector options • 14 different tones available including intensity and input control • Two model options - with or without RGB indication ## Pro Editor Use Banner's Pro Editor software and Pro Converter Cable to create custom configurations by selecting different colors, flash patterns, and animations. For more information visit www.bannerengineering.com/proeditor. ## Models **==> picture [481 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> Family Color and Input Audible Alarm Connector [(1)]<br>K50PCL A Q<br>Blank = 2 m (6.5 ft) integral PVC-jacketed cable<br>Blank = No color indication<br>K50PCL = Compact with Audible A = Audible Q = Integral 5-pin M12 male quick-disconnect connector<br>RGB7 = RGB Multicolor (7 colors)<br>QP = 150 mm (6 in) PVC-jacketed cable with a 5-pin M12 male<br>quick-disconnect connector<br>**----- End of picture text -----**<br> ## Wiring Diagrams **==> picture [486 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> PNP Input NPN Input<br>bu (3) bu (3)<br>+<br>10–30 V DC 10–30 V DC<br>bk (4) bk (4)<br>1 1<br>7 —<br>bn (1) bn (1)<br>2 2<br>OC — oF<br>wh (2) wh (2)<br>3 3<br>oF OC -=<br>gy (5) gy (5)<br>A/F A/F<br>RGB with Audible Indicator Default Values<br>Color Red Green Yellow Blue Magenta Cyan White Audible (No<br>color)<br>Input 1 X X X X<br>Continued on page 2<br>**----- End of picture text -----**<br> ## RGB with Audible Indicator Default Values (1) Models with a quick-disconnect connector require a mating cordset. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com Original Instructions 10-Jun-25 p/n: 227785 Rev. C K50 Pro Compact with Audible Indicator **==> picture [500 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 1<br>Color Red Green Yellow Blue Magenta Cyan White Audible (No<br>color)<br>Input 2 X X X X<br>Input 3 X X X X<br>Input 4 [(2)] X<br>Audible Indicator Only – Default Values for Low-Intensity Tones<br>Audible Continuous 2 Whoop Pulse Staccato Siren Jingle Melody 1<br>Input 1 X X X X<br>Input 2 X X X X<br>Input 3 X X X X<br>Input 4 [(3)]<br>**----- End of picture text -----**<br> An "X" denotes an active input, for example when Input 1 and Input 3 are active, the indicator will show Magenta. ## Specifications Supply Voltage and Current 12 V DC to 30 V DC Standard Models: 210 mA maximum - 199 mA at 12 V DC - • 83 mA at 24 V DC • 69 mA at 30 V DC - Audible-Only Models: 25 mA maximum • 22 mA at 12 V DC • 14 mA at 24 V DC • 13 mA at 30 V DC ## Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Input Response Time 250 milliseconds maximum ## Audible Characteristics Values shown apply to continuous tone. Frequency and intensity response vary depending on the Audible Tone selected. 2.9 KHz ± 250 Hz Audible Intensity: Low intensity at 2.9 KHz: 83 dB at 1 m Medium intensity at 2.9 KHz: 88 dB at 1 m High intensity at 2.9 KHz: 92 dB at 1 m ## Connections Integral 5-pin M12 male quick-disconnect connector, 150 mm (6 in) PVC-jacketed cable with an M12 quick disconnect, or 2 m (6.5 ft) integral PVC-jacketed cable, depending on model Models with a quick disconnect require a mating cordset ## Mounting M30 by 1.5 threaded base, maximum torque 4.5 N·m (40 inch-lbf) Mounting nut included ## Construction ## Operating Conditions - –40 °C to +50 °C (–40 °F to +122 °F) - 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) Environmental Rating IP67, IP69K per ISO 20653 Meets UL Type 4X, and UL Type 12 or UL Type 13 when mounted in a UL Type 12 or Type 13 enclosure All cabled models also meet IP69K per ISO 20653 if the cable and cable entrance are protected from high-pressure spray Certifications **==> picture [31 x 88] intentionally omitted <==** Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN ## Pro Editor Configuration - Connection to Pro Editor software enables control of: • Animation: On, Flash, Two Color Flash, 50/50, 50/50 Rotate, Chase, Intensity Sweep, Demo - • Color: Green, Red, Yellow, Blue, White, Cyan, Magenta, Amber, Rose, Lime Green, Orange, Sky Blue, Violet, Spring Green - • Intensity: Low, Medium, High • Speed: Slow, Standard, Fast • Audible Tones: Pulse, Wobble, Strobe, Whoop, Staccato, Siren, Continuous 1, Continuous 2, Jingle, Melody 1, Melody 2, Melody 3 - • Audible Intensity: Low, Medium, High - Pro Converter Cable required to interface between PC and indicator, see accessories Model Base, Dome, and Nut: Polycarbonate ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) (2) Input 4 controls audible functionality. Apply 12 V DC to 30 V DC to add audible to the color indication, or leave floating for color indication only. (3) Input 4 controls audible intensity. Apply 12 V DC to 30 V DC for high intensity, or leave floating for low intensity. page 2 of 7 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25 K50 Pro Compact with Audible Indicator ## Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. |Supply<br>Wiring<br>(AWG)<br>20|Required Overcurrent<br>Protection (A)<br>5.0|Required Overcurrent<br>Protection (A)<br>5.0|Supply<br>Wiring<br>(AWG)<br>26|Required Overcurrent<br>Protection (A)<br>1.0|Required Overcurrent<br>Protection (A)<br>1.0| |---|---|---|---|---|---| |22|3.0||28|0.8|| |24|1.0||30|0.5|| ## Default Indicator Characteristics ||Color Coordinates(4)|Color Coordinates(4)| |---|---|---| ||x|y| |532|0.181|0.735| |621|0.691|0.308| |578|0.473|0.474| |467|0.137|0.056| |-|0.379|0.177| |492|0.15|0.334| |590|0.552|0.414| |-|0.508|0.23| |565|0.393|0.535| |600|0.611|0.37| |485|0.146|0.241| |-|0.212|0.091| |509|0.157|0.553| ||0.328|0.337| ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. > (4) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. Actual coordinates may differ by 10%. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 7 10-Jun-25 K50 Pro Compact with Audible Indicator ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [500 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> Cabled Models Quick Disconnect Models<br>17 mm 17 mm<br>[0.67”]<br>[0.97]<br>37.0 mm<br>37 mm [1.46”] 48.0 mm<br>[1.46] [1.89”]<br>M30 x 1.5<br>Ø50 mm<br>[1.97”]<br>Ø 50 mm<br>[1.97]<br>**----- End of picture text -----**<br> ## Accessories ## Pro Editor Hardware ## MQDC-506-USB - Pro Converter Cable - • 1.83 m (6 ft) length 5-pin M12 quick disconnect to Device and USB to PC • Required for connection to the configuration software **==> picture [91 x 37] intentionally omitted <==** ## CSB-M1251FM1251M - 5-pin parallel Y splitter (Male-Male-Female) - • For full Pro Editor preview capability • Requires external power supply, sold separately ## PSW-24-1 - 24 V DC, 1 A power supply - • 2 m (6.5 ft) PVC cable with M12 quick disconnect • Provides external power with splitter cable, sold separately ## ACC-PRO-CABLE5 - Mating accessory for cabled and terminal models - • 150 mm (6 inch) PVC cable with M12 quick disconnect • Lever wire nuts included (qty 5) • Required to connect cabled models and screw terminal models to Pro Converter Cable, sold separately x5 page 4 of 7 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25 K50 Pro Compact with Audible Indicator ## Cordsets |Model|Length|Style|Dimensions|Pinout (Female)| |---|---|---|---|---| |MQDC1-501.5|0.5 m (1.5 ft)|Straight|44 Typ.<br>ø 14.5<br>M12 x 1<br>, anes|2<br>3<br>4<br>1<br>5<br>1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black<br>5 = Gray<br>eUy)us| |MQDC1-503|0.9 m (2.9 ft)|||| |MQDC1-506|2 m (6.5 ft)|||| |MQDC1-506<br>MQDC1-515|2 m (6.5 ft)<br>5 m (16.4 ft)|||| |MQDC1-530|5 m (16.4 ft)<br>9 m (29.5 ft)|||| |MQDC1-560|18 m (59 ft)|||| |MQDC1-5100|31 m (101.7 ft)|||| |MQDC1-506RA|2 m (6.5 ft)|Right-Angle|32 Typ.<br>[1.26"]<br>30 Typ.<br>[1.18"]<br>ø 14.5 [0.57"]<br>M12 x 1<br>_ft =<br>=eT<br>cal|| |MQDC1-515RA|5 m (16.4 ft)|||| |MQDC1-530RA|9 m (29.5 ft)|||| |MQDC1-560RA|19 m (62.3 ft)|||| ## Splitter Cables for Use with IO-Blocks **==> picture [480 x 234] intentionally omitted <==** **----- Start of picture text -----**<br> 5-Pin M12 to 4-Pin M12 Combiner Cordset with Flat Junction<br>Model Branches (Male) Trunk (Female) Pinout<br>CSF-M12F51M12M41 4-pin Quick Disconnect, 2 × 0.31 m 5-pin Quick Disconnect, 0.31 m Female<br>(1.02 ft) (1.02 ft) 2<br>1<br>3<br>4 5<br>Male<br>ø4.5 18.0 49.0 Typ.<br>: 44.0 Typ. ø14.5 2 1<br>ø14.5 4<br>Sooty) oe M12 x 1<br>3<br>M12 x 1 =o Bim) eal ro<br>35.0 43.0 II S)<br>1 = brown (trunk); no connection (branches 1 and 2)<br>2 = white (trunk); brown (branch 1); gray (branch 2)<br>3 = blue (trunk; branches 1 and 2)<br>4 = black (trunk); black (branch 1); white (branch 2)<br>5 = gray (trunk only)<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 7 10-Jun-25 K50 Pro Compact with Audible Indicator ## Brackets - 45 - SMB30A • Right-angle bracket with curved slot for versatile orientation •• Clearance for M6 (¼ in) hardwareMounting hole for 30 mm sensor 61 C • 12-gauge stainless steel B A - Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 × 6.3, C=ø 30.5 69 - SMB30FVK 46 • V-clamp, flat bracket and fasteners for mounting to pipe or extensions 118 •• Clamp accommodates 28 mm dia. tubing or 1 in. square extrusions30 mm hole for mounting sensors A - Hole size: A= ø 31 A - SMB30RAVK • V-clamp, right-angle bracket and fasteners for mounting sensors to pipe or extrusion • Clamp accommodates 28 mm dia. tubing or 1 in. square extrusions 46 • 30 mm hole for mounting sensors - Hole size: A = ø 30.5 57 90 45 - SMBAMS30P • Flat SMBAMS series bracket C • 30 mm hole for mounting sensors • Articulation slots for 90°+ rotation A • 12-gauge 300 series stainless steel 93 B - Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 × 7.0, B=ø 6.5, C=ø 31.0 - SMBAMS30RA 45 • Right-angle SMBAMS series bracket C • 30 mm hole for mounting sensors • Articulation slots for 90°+ rotation 53 A • 12-gauge (2.6 mm) cold-rolled steel B - Hole center spacing:Hole size: A=26.8 × 7.0, B=ø 6.5, C=ø 31.0 A=26.0, A to B=13.0 48 70 57 - SMB30MM • 12-gauge stainless steel bracket with curved mounting slots for versatile orientation • Clearance for M6 (¼ in) hardware C • Mounting hole for 30 mm sensor 57 B - Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 × 7, B = ø 6.4, C = ø 30.1 A 67 - SMB30SC • Swivel bracket with 30 mm mounting hole for sensor B •• Black reinforced thermoplastic polyesterStainless steel mounting and swivel locking hardware included 58 - Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 29 A page 6 of 7 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25 K50 Pro Compact with Audible Indicator **==> picture [500 x 319] intentionally omitted <==** **----- Start of picture text -----**<br> SMB30FA 83.2<br>• Swivel bracket with tilt and pan movement for precise adjustment<br>• Mounting hole for 30 mm sensor<br>• 12-gauge 304 stainless steel<br>• Easy sensor mounting to extrude rail T-slot<br>• Metric- and inch-size bolt available 36.3 B 68.9<br>A<br>Bolt thread: SMB30FA, A= 3/8 - 16 × 2 in; SMB30FAM10, A= M10 - 1.5 × 50<br>Hole size: B= ø 30.1<br>55<br>LMBE12RA35 35 38.25<br>• Direct mounting of stand-off pipe, with common bracket type<br>• Zinc-plated steel<br>• 1/2-14 NPSM nut<br>• Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 35 mm<br>57<br>Hole center spacing: 20.0<br>2X Ø9<br>65<br>45<br>LMBE12RA45 38.25<br>• Direct mounting of stand-off pipe, with common bracket type<br>• Zinc-plated steel<br>• 1/2-14 NPSM nut<br>• Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 45 mm<br>81<br>Hole center spacing: 35.0<br>2X Ø11<br>**----- End of picture text -----**<br> All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 7 10-Jun-25
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →