K50BCLGRYS1QP
VISUAL SIGNAL INDICATOR UNITS
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 231.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
EZ-LIGHT® K50 Modbus Series Multicolor Indicators ## Features - Rugged, compact multi-color indicators in several package types - • Built-in flashing and strobing capability • High intensity models for outdoor applications • Fully encapsulated IP67/IP69K construction • Modbus RTU communication minimizes the cabling requirements **==> picture [487 x 233] intentionally omitted <==** **----- Start of picture text -----**<br> Models Indicator Type Picture Colors Connection<br>K50LGRYS1Q Integral 4-pin M12 male quick-disconnect connector<br>Standard Domed<br>150 mm (6 in) PVC-jacketed cable with a 4-pin M12<br>K50LGRYS1QP<br>male quick-disconnect connector<br>K50LDGRYS1Q Integral 4-pin M12 male quick-disconnect connector<br>Green, Red,<br>Daylight Visible Yellow 150 mm (6 in) PVC-jacketed cable with a 4-pin M12<br>K50LDGRYS1QP<br>male quick-disconnect connector<br>K50BLGRYS1Q Integral 4-pin M12 male quick-disconnect connector<br>Beacon (Perimeter)<br>150 mm (6 in) PVC-jacketed cable with a 4-pin M12<br>K50BLGRYS1QP<br>male quick-disconnect connector<br>K50BCLGRYS1Q Integral 4-pin M12 male quick-disconnect connector<br>Beacon (Perimeter<br>K50BCLGRYS1QP and Center) 150 mm (6 in) PVC-jacketed cable with a 4-pin M12<br>male quick-disconnect connector<br>**----- End of picture text -----**<br> ## Wiring **==> picture [415 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> 4-pin M12 Quick-Disconnect Connector (Male) Pins Wire Color Sensor Connection<br>1 1 Brown Power IN (+), 12 V DC to 30 V DC<br>2 (r= 2 White RS-485 +<br>3 Blue Ground (-)<br>4<br>3 @) 4 Black RS-485 (-)<br>**----- End of picture text -----**<br> - For cables, use Turck's BL ident® cables or their equivalent. For example: ◦ RK 4.5T-2-RS 4.5T/S2501 2 meter double-ended male/female - RK 4.5T-1-RS 4.5T/S2501 1 meter double-ended male/female - ◦ RK 4.5T-2/S2501 single-ended 2 meter female - For tees, use Turck RSC 2RKC 57 - For terminators, use Banner model EZL-RTM-M or EZL-RTM-F Original Instructions 10-Jun-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com p/n: 183980 Rev. C EZ-LIGHT® K50 Modbus Series Multicolor Indicators ## Typical Installation **==> picture [462 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> A B B B<br>brown (+)<br>blue (-)<br>bare (shield)<br>white<br>black<br>C C D<br>**----- End of picture text -----**<br> **==> picture [500 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> A Single-ended cable<br>B Tee<br>C Double-ended cable<br>D Terminator. Contains a 120 Ohm termination resistor connected across pins 2 and 4. Use the terminator for long cables or long lines of cascaded units to<br>prevent signal reflections from occurring on the communication lines.<br>**----- End of picture text -----**<br> **==> picture [500 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> 5-pin M12 Quick-Disconnect Connector (Male) Pin Wire Color<br>1 Brown<br>1<br>2 White<br>2<br>4 3 Blue<br>4 Black<br>3 5<br>5 Bare (Shield). Connect the shield to ground at the power supply connection.<br>**----- End of picture text -----**<br> ## Modbus RTU Registers The EZ-LIGHT uses the holding registers table for providing read/write access to configuration data. The holding registers are defined in the 40000-49999 address range. The input registers table is used for providing read-only access to system status data. The input registers are defined in the 30000-39999 address range. EZ-LIGHT employs a direct addressing scheme. For example, the input register at address 30000 is accessed by reading address 30000 (0x7530) directly; the starting address is not an offset. ## Supported Modbus RTU Functions **==> picture [500 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> Functions Output Status<br>03 Reading holding registers<br>04 Read input registers<br>06 Write single registers<br>08 See Diagnostics, Function 8 (0x08) for supported commands.<br>16 (0x10) Write multiple registers<br>23 (0x17) Read/write multiple registers<br>**----- End of picture text -----**<br> ## Holding Registers **==> picture [500 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> Address Description Holding Register Representation<br>40001 Modbus slave address 1 (default) through 247<br>40002 Baud 0 = 9.6k<br>1 = 19.2k (default)<br>2 = 38.4k<br>Continued on page 3<br>**----- End of picture text -----**<br> page 2 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25 EZ-LIGHT® K50 Modbus Series Multicolor Indicators **==> picture [500 x 283] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 2<br>Address Description Holding Register Representation<br>40003 Parity 0 = even (default)<br>1 = odd<br>2 = none<br>40004 Stop bits 1 = 1 stop bit (default)<br>2 = 2 stop bits<br>40005 Configuration Select 0 = No selectable configuration<br>1 = Solid light configuration 183564<br>2 = Flashing light configuration 183563<br>3 = Strobe light configuration 183565<br>40006 Modbus Settings Policy 0 = Apply After Power Cycle (default)<br>1 = Apply After Write<br>40100 Color 1 Register 0 = Color Inactive (power on value)<br>1 = Color Active<br>40101 Color 2 Register 0 = Color Inactive (power on value)<br>1 = Color Active<br>40102 Color 3 Register 0 = Color Inactive (power on value)<br>1 = Color Active<br>**----- End of picture text -----**<br> ## Solid Light Configuration 183564 The three colors are solid. Color 2 overrides color 1 and color 3 overrides colors 1 and 2. **==> picture [500 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> Input Action<br>Color 1 Color 2 Color 3 LED Function<br>Not active Not active Not active Light off<br>Active Not active Not active Green light on<br>Not active Active Not active Red light on<br>Not active Not active Active Yellow light on<br>Active Active Not active Red light on<br>Active Not active Active Yellow light on<br>Not active Active Active Yellow light on<br>Active Active Active Yellow light on<br>**----- End of picture text -----**<br> ## Flashing at 1.5 Hz, 50% Duty Cycle Configuration 183563 The three colors are flashing. Color 2 overrides color 1 and color 3 overrides colors 1 and 2. **==> picture [500 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> Input Action<br>Color 1 Color 2 Color 3 LED Function<br>Not active Not active Not active Light off<br>Active Not active Not active Green flashing<br>Not active Active Not active Red flashing<br>Not active Not active Active Yellow flashing<br>Active Active Not active Red flashing<br>Active Not active Active Yellow flashing<br>Not active Active Active Yellow flashing<br>Active Active Active Yellow flashing<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 8 10-Jun-25 EZ-LIGHT® K50 Modbus Series Multicolor Indicators ## Strobe at 2 Hz, 25% Duty Cycle (100 ms ON, 400 ms OFF) Configuration 183565 The three colors strobe. Color 2 overrides color 1 and color 3 overrides colors 1 and 2. **==> picture [500 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> Input Action<br>Color 1 Color 2 Color 3 LED Function<br>Not active Not active Not active Light off<br>Active Not active Not active Green strobe<br>Not active Active Not active Red strobe<br>Not active Not active Active Yellow strobe<br>Active Active Not active Red strobe<br>Active Not active Active Yellow strobe<br>Not active Active Active Yellow strobe<br>Active Active Active Yellow strobe<br>**----- End of picture text -----**<br> ## Input Registers The following information registers (31000–31022) must be read as a block, they cannot be read as single registers. **==> picture [500 x 423] intentionally omitted <==** **----- Start of picture text -----**<br> Address Description Input Register Representation<br>31000 Low word firmware part number Example: 0x0002A734 (hex) = 173876 (dec)<br>31001 High word firmware part number High word=0x0002; Low word = 0xA734<br>31002 Firmware version Bits 7–4 = Major Version<br>Bits 3–0 = Minor Version<br>Example:0x0012 is version 1.2<br>31003 Build number 0–0xFFFF (hex) = 0–65535 (dec)<br>31004 Low word model number Example: 0x0002A734 (hex) = 173876 (dec)<br>31005 High word model number High word = 0x0002; Low word = 0xA734<br>31006 Model version Bits 7–4 = Major Version<br>Bits 3–0 = Minor Version<br>Example: 0x0012 is version 1.2<br>31007 Low word configuration number Example: 0x0002CD0B (hex) = 183563 (dec)<br>31008 High word configuration number High word = 0x0002; Low word = CD0B<br>31009 Configuration version Bits 7–4 = Major Version<br>Bits 3–0 = Minor Version<br>Example: 0x0012 is version 1.2<br>31013–31013 Date code, 8 bytes<br>31014 Low Word Flash Config 1 Part Example: 0x0002CD0C (hex) = 183564 (dec)<br>Number<br>High word = 0x0002; Low word = 0xCD0C<br>31015 High Word Flash Config 1 Part<br>Number 0xFFFFFFFF (hex) = No flash configuration<br>31016 Flash Config 1 Version Bits 7–4 = Major Version<br>Bits 3–0 = Minor Version<br>0x00FF = No flash version<br>31017 Low Word Flash Config 2 Part Example: 0x0002CD0B (hex) =183563 (dec)<br>Number<br>High word = 0x0002; Low word = 0xCD0B<br>31018 High Word Flash Config 2 Part<br>Number 0xFFFFFFFF (hex) = No flash configuration<br>Continued on page 5<br>**----- End of picture text -----**<br> page 4 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25 EZ-LIGHT® K50 Modbus Series Multicolor Indicators **==> picture [500 x 274] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 4<br>Address Description Input Register Representation<br>31019 Flash Config 2 Version Bits 7–4 = Major Version<br>Bits 3–0 = Minor Version<br>0x00FF = No flash version<br>31020 Low Word Flash Config 3 Part Example: 0x0002CD0D (hex) = 183565 (dec)<br>Number<br>High word = 0x0002; Low word = 0xCD0D<br>31021 High Word Flash Config 3 Part<br>Number 0xFFFFFFFF (hex) = No flash configuration<br>31022 Flash Config 3 Version Bits 7–4 = Major Version<br>Bits 3–0 = Minor Version<br>0x00FF (hex) = No flash version<br>32000 Bus Message Count Returns same value as Diagnostic Function sub-function 11 (0x0B)<br>32001 Bus Communication Error Count Returns same value as Diagnostic Function sub-function 12 (0x0C)<br>32002 Bus Exception Error Count Returns same value as Diagnostic Function sub-function 13 (0x0D)<br>32003 Server Message Count Returns same value as Diagnostic Function sub-function 14 (0x0E)<br>32004 Server NAK Count Returns same value as Diagnostic Function sub-function 16 (0x10)<br>32005 Bus Character Overrun Count Returns same value as Diagnostic Function sub-function 18 (0x12)<br>32006 Buffer Overrun Count Returns the count of the number of times that a buffer overrun has occurred.<br>**----- End of picture text -----**<br> ## Diagnostics, Function 8 (0x08) **==> picture [500 x 212] intentionally omitted <==** **----- Start of picture text -----**<br> Subfunction Description<br>0 Return Query Data<br>1 Restart Communications Option Not supported<br>2 Return Diagnostic Register Returns value of 0, any other value is an internal error condition<br>10 (0x0A) Clear Counters and Diagnostic Register<br>11 (0x0B) Return Bus Message Count<br>12 (0x0C) Return Bus Communication Error Count<br>13 (0x0D) Return Bus Exception Error Count<br>14 (0x0E) Return Server Message Count<br>15 (0x0F) Return Server No Response Count Not supported<br>16 (0X10) Return Server NAK Count<br>17 (0X11) Return Server Busy Count Not supported<br>18 (0x12) Return Bus Character Overrun Count<br>20 (0x14) Clear Overrun Counter and Flag<br>**----- End of picture text -----**<br> ## Example Commands and Responses For these examples, the slave address is 1. Write Color 1 Active Master 01109CA4000102000122BD Response 01109CA400016E7A ## Write Color 1 Inactive Master 01109CA40001020000E37D Response 01109CA400016E7A © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 8 10-Jun-25 EZ-LIGHT® K50 Modbus Series Multicolor Indicators ## Read Device Status Registers Master 0104753100023A08 Command to read both output and sensor status registers Possible 01040400000000FB84 Output Inactive, button not pressed Responses 010404000100016B84 Output Active, button pressed 01040400010000AA44 Output Active, button not pressed Write Configuration Registers Master 01109C410003060001000100001BC3 Write three registers: Slave address 1, 19200 baud, Even parity Response 01109C410003FE4C Read Configuration Registers Master 01039C4100037B8F Command to read all three configuration registers Response 0103060001000100004D75 Response with slave address 1, 19200 baud, even parity Read Information Registers Master 010479180017295F Command to read all info registers Response 01042EA7340002001000026D4300010010CFE4000200106AF319E27D1240E4C7AA00020010CE8400020010CFE400020010C652 Write Configuration Registers Read Configuration Registers ## Read Information Registers ## Specifications Supply Voltage and Current 12 V DC to 30 V DC K50L 3-Color models: 70 mA at 12 V DC; 55 mA at 30 V DC K50LD 3-Color models: 110 mA at 12 V DC; 70 mA at 30 V DC K50BL 3-Color models: 85 mA at 12 V DC; 60 mA at 30 V DC K50BCL 3-Color models: 110 mA at 12 V DC; 70 mA at 30 V DC Supply Protection Circuitry Protected against reverse polarity and transient voltages Environmental Rating IP67 and IP69K per ISO 20653 ## Operating Conditions –40 °C to +50 °C (–40 °F to +122 °F) 90% at +50 °C maximum relative humidity (non-condensing) Storage: –40 °C to +70 °C (–40 °F to +158 °F) ## Communication Interface: RS-485 Serial Baud Rates: 9.6k, 19.2k (default), or 38.4k Data format: 8 data bits, no parity (default), 1 stop bit (even or odd parity available) Protocol: Modbus RTU ## Connections Integral 4-pin M12 male quick-disconnect connector or 150 mm (6 in) PVC-jacketed cable with a 4-pin M12 male quickdisconnect connector ## Vibration and Mechanical Shock All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms duration, half sine wave) requirements. ## Light Intensity **==> picture [238 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> Typical Intensity (Lumen)<br>Wavelength<br>Color<br>(nm) K50L K50LD K50BL K50BCL<br>Green 525 29 69 50 58<br>Red 625 13 27 20 23<br>Yellow 590 10 13 11 12<br>Certifications<br>Banner Engineering BV<br>Park Lane, Culliganlaan 2F bus 3<br>1831 Diegem, BELGIUM<br>**----- End of picture text -----**<br> Construction Housing: polycarbonate Translucent dome: polycarbonate Mounting Nut: PBT ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. page 6 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25 EZ-LIGHT® K50 Modbus Series Multicolor Indicators ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [500 x 488] intentionally omitted <==** **----- Start of picture text -----**<br> K50BL and BCL Models K50L Models<br>50<br>[ 1.97 ]<br>50.0 mm<br>(1.97")<br> 38 mm (1.50")*<br>M30 x 1.5<br>29 (mounting nut<br>[1.14] included)<br>49[1.93] Max. Torque 4.5 Nm<br>(40 in-lbf)<br>20 mm (0.79")<br>11<br>[.43] Internal Threads<br>½ - 14 NPSM 11 mm (0.43")<br>Max. Torque 2.25 Nm<br>M12 (20 in-lbf)<br>K50LD Models<br>Ø50 mm (1.97")<br>13 mm<br>(0.51")<br>49.5 mm<br>(1.95")<br>20 mm<br>(0.79") M30 X 1.5<br>(mounting nut included)<br>max. torque 4.5 Nm (40 in-lbf)<br>11 mm<br>(0.43") Internal Threads<br>½- 14 NPSM<br>max. torque 2.25 Nm (20 in-lbf)<br>M12 X 1<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 8 10-Jun-25 EZ-LIGHT® K50 Modbus Series Multicolor Indicators This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 8 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 10-Jun-25
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →