K30PAF100AMRGB7Q
DISTANCE SENSORS
- Manufacturer: BANNER ENGINEERING
- Product type:
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 180.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
K30 Pro Optical Sensor Quick Start Guide ## Quick Start Guide ## 30 mm Programmable Multicolor RGB Optical Sensor and Indicator This guide is designed to help you set up and install the K30 Pro Optical Sensor. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com. Search for part num ber 231384 to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices. **==> picture [52 x 81] intentionally omitted <==** - Programmable using Banner's Pro Editor software and Pro Converter Cable - • Up to 7 colors in one device (14 colors using Pro Editor) • Devices are completely selfcontained—no controller needed • Teachable modes with color feedback for ease of use • Touchless activation removes the need for physical force to activate • Rated IP65 • 10 V DC to 30 V DC operation • Resistant to ambient light, EMI, and RFI interference • Sensing and indication in one device **==> picture [32 x 73] intentionally omitted <==** - WARNING: • Do not use this device for personnel protection • Using this device for personnel protection could result in serious injury or death. • This device does not include the selfchecking redundant circuitry necessary to allow its use in personnel safe ty applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition. ## Models **==> picture [340 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> Activation Output<br>Family Style Method Output State Function Color/Control Connector<br>K30 P AF100 A M Q<br>Q = 5-pin or 8-pin integral<br> M12 quick disconnect<br>AF100 = 100mm adjustable field* M = Momentary depending on model **<br>AF1000 = 1000mm adjustable field*<br> ** Models with a quick disconn<br>RGB7 = Programmable Multicolor require a mating cordset<br>**----- End of picture text -----**<br> ## Overview The K30 Pro Optical Sensor is an adjustable field optical sensor that can detect a wide variety of materials and objects. ## **Detection Area** **==> picture [500 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> Measurement Detection Area<br>Reference Point<br>Reliable detection of a stationary<br>and moving object<br>D0 D1 D2<br>Model D0 (mm) Switch Point D1 (mm) Switch Point D2 (mm)<br>K30PAF1000 0 20 1000<br>**----- End of picture text -----**<br> Original Instructions July 17, 2023 © Banner Engineering Corp. p/n: 232898 Rev. C 232898 K30 Pro Optical Sensor Quick Start Guide ## Wiring Diagrams ## GRY3 Models **==> picture [500 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> NPN PNP<br>1 – 1 +<br>3 10-30V dc 3 10-30V dc<br>+ – Pin 1 = Brown<br>Pin 2 = White<br>4 4 Pin 3 = Blue<br>Load Load Pin 4 = Black<br>Pin 5 = Gray (Remote Input)<br>2 2<br> 1 1<br>5 5<br> 2 2<br>**----- End of picture text -----**<br> ## GRY3 Multicolor Color/Function Definition **==> picture [500 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> Green Yellow Red<br>Input 1 X X<br>Input 2 X X<br>**----- End of picture text -----**<br> ## GRY4 Models **==> picture [500 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> NPN PNP<br>1 – 1 +<br>3 10-30V dc 3 10-30V dc<br>+ – Pin 1 = Brown<br>Pin 2 = White<br>4 4 Pin 3 = Blue<br>Load Load Pin 4 = Black<br>Pin 5 = Gray (Remote Input)<br>2 2<br>1 1<br>5 5<br>Remote Input Remote Input<br>**----- End of picture text -----**<br> GRY4 Four State Full Logic No Detection Detection No Input State 1: Indicator Off State 3: Indicator Red Input 1 State 2: Indicator Green State 4: Indicator Yellow ## RGB7 Models **==> picture [500 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> NPN PNP<br>2 – 2 +<br>7 10-30V dc 7 10-30V dc Pin 1 = White<br>+ – Pin 2 = Brown<br>1 1 Pin 3 = Green<br>Load Load Pin 4 = Yellow (Remote Input)<br>3 3 Pin 5 = Not used<br> 1 1 Pin 6 = Not used<br>8 8 Pin 7 = Blue<br> 2 2 Pin 8 = Red<br>4 4<br> 3 3<br>**----- End of picture text -----**<br> ## RGB Multicolor Color/Function Definition **==> picture [500 x 51] intentionally omitted <==** **----- Start of picture text -----**<br> Red Yellow Green Cyan Blue Magenta White<br>Input 1 X X X X<br>Input 2 X X X X<br>Continued on page 3<br>**----- End of picture text -----**<br> page 2 July 17, 2023 © Banner Engineering Corp. K30 Pro Optical Sensor Quick Start Guide Continued from page 2 Red Yellow Green Cyan Blue Magenta White Input 3 X X X X ## Configuring a Sensor The K30 Pro Optical Sensor has three Teach modes. These modes are indicated with a Teach Status color. The Signal Level color flashes in between the Teach Status color. The color of the Signal Level depends on the signal strength of the target: Green: Best signal, accepts Teach Yellow: Acceptable signal, can accept Teach Red: Poor signal, rejects Teach ## Remote Input Use the remote input to program the sensor remotely. The remote input provides limited programming options and is Active High in PNP mode (V+ to brown wire), or Active Low in NPN mode (V+ to blue wire). For Active High, pulse the gray or yellow input wire to V+ (10 V DC to 30 V DC). For Active Low, pulse the gray or yellow input wire to ground (0 V DC). The remote input wire is enabled by default. Pulse the remote input wire 7 times or use the Banner Pro Editor software to enable or disable the feature. When the remote input feature is enabled, pulse the remote input according to the diagram and the instructions provided in this manual. Remote teach can also be performed using the button on the Pro Converter Cable. The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds . Exit remote programming modes by cycling power or by waiting for 30 seconds. NOTE: If a factory reset is performed through the Banner Pro Editor Software, the remote input wire becomes enabled (factory default setting). If the sensor is returned to factory defaults by using the remote input wire, the input wire re mains enabled and the rest of the settings are restored to factory defaults. ## Remote Teach Use the following procedure to teach the Set Point. 1. Pulse the remote input: - 3x Object Teach: The indicator alternates between a blue Teach Status color and the Signal Level color. - 4x Background Teach: The indicator alternates between a magenta Teach Status color and the Signal Level color. - 5x Window Teach: The indicator alternates between a cyan Teach Status color and the Signal Level color. 2. Present the Set Point. 3. Teach the Set Point. Action Result Teach Accepted The indicator stops flashing and the device returns to operation. T Teach Not Accepted Single pulse the remote input. The Signal Level color turns red during the teach procedure, and then the indicator stops flashing. Retry teaching the set point. July 17, 2023 page 3 © Banner Engineering Corp. K30 Pro Optical Sensor Quick Start Guide **==> picture [330 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> Remote Input Map<br>Remote<br>Input Gray/Yellow wire is remote teach input Pulse Timing (T)<br>0.04 seconds < T < 0.8 seconds<br>Timing between pulse less than 1 second<br>3x Object Mode Teach<br>1x Confirm Teach<br>4x Background Mode Teach<br>1x Confirm Teach<br>5x Window Mode Teach<br>1x Confirm Teach<br>7x Enable/Disable Remote Teach<br>1x Confirm Enable/Disable<br>9x Reset to Factory Defaults<br>1x Confirm Factory Reset<br>**----- End of picture text -----**<br> ## Specifications Supply Voltage (Vcc) 10 V DC to 30 V DC Supply Current 110 mA maximum current at 30 V DC (exclusive of load) 30 mA typical current at 24 V DC (exclusive of load) ## Construction Base, Dome, and Nut: Polycarbonate ## Connections Integral 5-pin or 8-pin M12 male quick-disconnect connector Models with a quick disconnect require a mating cordset ## Supply Protection Circuitry Protected against output short-circuit Leakage Current Immunity 400 µA NOTE: A shielded cable is required if the sensor is mounted outdoors or if the ca ble is longer than 30 m (98.4 ft). ## Range The sensor can detect an object at the following ranges, de pending on the material and size of the target: 20 mm to 1000 mm ## Output Ratings Maximum Load : 150 mA ON-State Saturation Voltage : < 2 V DC at 10 mA < 2.5 V DC at 150 mA OFF-State Leakage Current : < 10 µA at 30 V DC ## Remote Input Allowable Input Voltage Range: 0 to Vsupply Active High (internal weak pull-down): High state > (Vsupply - 2.25 V) at 2 mA maximum Active Low (internal weak pull-up): Low state < 2.25 V at 2 mA maximum ## Mounting M22 × 1.5 threaded base, maximum torque 4.5 N·m (40 in·lbf) ## Vibration and Mechanical Shock All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 10G acceleration) requirements. Method 213B conditions H&I.Shock: 75G with device operating; 100G for nonopera tion ## Operating Temperature –20 °C to +50 °C (–4 °F to +122 °F) ## Storage Temperature –40 °C to +70 °C (–40 °F to +158 °F) Sensing Beam Infrared, 940 nm ## Delay at Powerup < 1 s ## Response Time Switching frequency: 4 Hz Discrete output response: 120 ms July 17, 2023 page 4 © Banner Engineering Corp. K30 Pro Optical Sensor Quick Start Guide Repeatability ## Required Overcurrent Protection 5 mm from 20 to 300 mm 8 mm from 300 mm to 600 mm 14 mm from 600 mm to 1000 mm ## Temperature Effect <±5 mm from –20 °C to +50 °C (–4 °F to +122 °F) **==> picture [32 x 42] intentionally omitted <==** WARNING: Electrical connections must be made by qualified personnel in ac cordance with local and national electri cal codes and regulations. ## Application Note For the most accurate measurements, allow 5 minutes for the sensor to warm up Environmental Rating IP65 Pro Editor Configuration Connection to Pro Editor software enables control of: - Animation: Steady, Flash, Two Color Flash, 50/50, 50/50 Rotate, Chase, Intensity Sweep, Color Sweep, Wave, Double Wave - Color: Green, Red, Yellow, Blue, White, Cyan, Ma genta, Amber, Rose, Lime Green, Orange, Sky Blue, Violet, Spring Green - Intensity: Low, Medium, High - Speed: Slow, Standard, Fast - Output State: Normally Open, Normally Closed, Mo mentary, Latching, On Delay, Off Delay - Logic Type: Three State Advanced Control (F2 Mode), Seven State Advanced Control (F2 Mode), Four State Full Logic (Custom) Pro Converter Cable required to interface between PC and in dicator, see accessories Overcurrent protection is required to be provided by end prod uct application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. **==> picture [222 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM ## FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. July 17, 2023 page 5 © Banner Engineering Corp. K30 Pro Optical Sensor Quick Start Guide ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [272 x 290] intentionally omitted <==** **----- Start of picture text -----**<br> Ø 30.0<br>[1.18] 16.8<br>[0.66] 18.0<br>31.8<br>[0.71]<br>[1.25]<br>47.8<br>[1.88] M22 x 1.5<br>M12 x 1<br> Typical beam pattern, in millimeters<br>100<br>80 90% White Card<br>18% Gray Card<br>60<br>40<br>20<br>0<br>-20<br>-40<br>-60<br>-80<br>-100<br>0 200 400 600 800 1000<br>DISTANCE (mm)<br>BEAM WIDTH (mm)<br>**----- End of picture text -----**<br> ## Beam Pattern **==> picture [43 x 35] intentionally omitted <==** ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of ship ment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUD ING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BAN NER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or lia bilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installa tion of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the prod uct warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other lan guage. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 6 July 17, 2023 © Banner Engineering Corp.
Updated at April 28, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →