K100PLNZRGB7.
BEACON, BLU/GRN/RED, MULTIFUNCTION, 240V
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- Module Lens Colour:Blue, Green, Red; Supply Voltage VAC:240V; Supply Voltage VDC:-; Visual Signal Type:Multifunction; Lens Diameter:3.65"; Product Range:K100 77AK6033
- Power Rating: 7W
- Lens Diameter: 3.65"
- Product Range: K100 Pro Series
- External Height: 5.3"
- IP / NEMA Rating: IP66, IP69K
- Module Lens Colour: Blue, Green, Red
- Supply Voltage VAC: 240V
- Supply Voltage VDC: -
- Visual Signal Type: Multifunction
- Operating Temperature Max: 60°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 392.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
K100 Pro Hazardous Indicator Beacon - AC Datasheet ## Features Multicolor Indicator with Optional Audible Alarm for Indoor or Outdoor Use **==> picture [59 x 85] intentionally omitted <==** - Industrial beacon providing bright indication for OEMs and users that need visible status infor mation - • Ex/HazLoc approvals for potentially explosive environment applications • Rugged construction provides years of uninterrupted operation • Unique watershed beacon design helps protect the indicator • Fourteen colors in one device • 36 mm threaded polycarbonate base • Rugged IP69K per DIN 40050-9, UL Type 4X housing • Variety of connector options • Rugged UVstabilized polycarbonate base and window • 100 V AC to 240 V AC operating voltage • IK08 impact rating for maximum protection demanding applications ## Models Standard models shown. Contact factory for other options. **==> picture [477 x 84] intentionally omitted <==** **----- Start of picture text -----**<br> Family Style Classification Colors Audible Connector *<br>K100 P L N Z RGB7 A Q<br>Blank = None Blank = 2 m integral ITC-ER PVC cable<br>RGB7 = RGB Multicolor Q = 5-pin integral 1/2 in. 20 UNF male<br> quick disconnect **<br>* Models with a quick disconnect require a mating cordset<br>** Must be enclosed with a protected conduit or a suitable enclosure<br>**----- End of picture text -----**<br> ## Installation Instructions ## Ex/HazLoc Applications **==> picture [32 x 193] intentionally omitted <==** - WARNING: • Explosive Atmospheres/Hazardous Locations • It is the user's responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relat ing to the installation and use of this device in any particular application are satisfied. This device must be in stalled by a Qualified Person[(1)] , in accordance with this document and applicable regulations. ## WARNING: - Explosion Hazard - • Do not disconnect equipment unless the power has been switched off or the area is known to be nonhaz ardous. ## CAUTION: - Electrostatic Discharge (ESD) Special Conditions for Safe Use - • Parts of the enclosure are nonconducting and can generate an ignitioncapable level of ESD. • Clean the equipment with only a damp cloth. ## General Notes and Conditions for Use - See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations, electrical connections and certifications. - In addition to the warning above concerning user responsibility, the installation must comply with the following: - (1) A Qualified Person is a person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work. Original Instructions June 12, 2023 © Banner Engineering Corp. p/n: 231074 Rev. B 231074 K100 Pro Hazardous Indicator Beacon - AC Datasheet - All installations must comply with all manufacturer's instructions. - All applicable wiring methods in accordance with the relevant local regulations and the authority having jurisdiction. - U.S. Installations: The relevant requirements of the National Electric Code® (ANSI/NFPA70 NEC®). - ◦ Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1). - Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with non-factory components may adversely affect the safe use of the system. - The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges. - Clean with a damp cloth only. - If the equipment is likely to come into contact with aggressive substances[(1)] , then it is the responsibility of the user to take suitable precautions[(2)] that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. - The ingress protection (IP rating) of enclosures/panels may be invalidated by the installation of the beacon. The installation of the beacon in a particular enclosure/panel is subject to the evaluation/acceptance of the authority having jurisdiction. - Models with integral quick-disconnect (QD) connectors: - Use recommended Banner cordsets (see "Cordsets" on page 4), or suitable quickdisconnect cordsets with threaded retain ing nut (see "Specifications" on page 3). The cordset must be securely fastened using the quickdisconnect retaining nut to prevent disconnection. Maximum connector torque: 6 ft-lbs. - Must be installed such that the connector is protected from impact and unauthorized disconnection. The method of protec tion can include conduit (e.g. pole, pendent), enclosed raceway, a listed enclosure suitable for the intended use, and/or by inaccessible location that excludes possible impact damage. ## Wiring **==> picture [500 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> Diagram Key<br>3<br>Neutral<br>1<br>1 Hot<br>1 = Brown<br>2 2 = Blue<br>2 3 = White<br>4 = Black<br>4 5 = Gray<br>3<br>5<br>A<br>**----- End of picture text -----**<br> An "X" denotes an active input. For example: When the black wire and the white wire are both active, the indicator will be Magenta Steady. ## Default Configuration **==> picture [500 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> Wiring Operating Mode/Function<br>Brown Blue Black Gray NonAudible Audible<br> X Red Steady Red Steady<br> X Green Steady Green Steady<br> X Blue Steady Blue Steady<br> X X Yellow Steady Yellow Steady<br> X X Magenta Steady Magenta Steady<br> X X Cyan Steady Cyan Steady<br> X X X White Steady White Steady<br> X Off Audible Steady, Frequency 2.5 KHz, Volume High<br> X X Red Steady Red Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X Green Steady Green Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X Blue Steady Blue Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X Yellow Steady Yellow Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X Magenta Steady Magenta Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>Continued on page 3<br>**----- End of picture text -----**<br> (1) Aggressive substances—for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. (2) Suitable precaution—for example, regular checks as part of routine inspections or establishing from the materials data sheet that is resistant to specific chemi cals. page 2 June 12, 2023 © Banner Engineering Corp. K100 Pro Hazardous Indicator Beacon - AC Datasheet **==> picture [500 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 2<br>Wiring Operating Mode/Function<br>Brown Blue Black Gray NonAudible Audible<br> X X X Cyan Steady Cyan Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X X White Steady White Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>**----- End of picture text -----**<br> ## Specifications ## Supply Protection Circuitry Protected against reverse polarity and transient voltages ## Leakage Current Immunity ## 400 µA - Application Note: The use of relay output PLC is recommend ed since there is no leakage current. Solid state output PLCs often have leakage current above 1 mA and, therefore, turn the light on in the off state. To counteract the leakage current, a shunt resistor must be used. A resistor must be applied from the neutral wire of the device to the hot wire of each channel of the device. ## Indicator Response Time On Response: 350 ms (maximum) Off Response: 20 ms (maximum) ## Connections Integral 5pin 1/2 in. 20UNF male quickdisconnect connec tor or 2 m (6.5 ft) integral ITCER PVCjacketed cable, de pending on model Models with a quick disconnect require a mating cordset Connecting 5pin M12 quickdisconnect cordsets (see "Cord sets" on page 4): Female single-ended Multiconductor cable (at minimum): UL Style 2517, 24 AWG wire, rated ≥ 80 °C; M12 quick-disconnect connector: per IEC 61076-2-101, must have threaded M12 x 1 retaining nut ## Construction Base, Dome, and Nut: Polycarbonate ## LED Lifetime Lumen maintenance L70 ## Approvals NEC and CEC (cULus) - Gas and Vapors: Class I Div 2 Groups ABCD T4 - • Dust and Fibers/flyings: Class II Div 2 Groups FG T6; Class III Div 1 and Div 2 T6 ## Maximum Input Power Light Only: 7.0 W Light and Audible: 9.7 W ## Audible Characteristics Sound Intensity at 2.5 KHz, at 1 m (typical): Low volume setting: 93 dB Medium volume setting: 96 dB High volume setting: 101 dB ## Operating Conditions –40 °C to +60 °C (–40 °F to +140 °F) 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068227 requirements (Shock: 30G 11 ms dura tion, half sine wave) Impact: IK08 (IEC 60068-2-75) ## Environmental Rating IP66, IP69K per DIN 40050-9, UL Type 4X ## Certifications When operating within specifications, output decreases less than 30% after 42,000 hours ## Mounting M36 by 2.0 threaded base, maximum torque 5.0 N·m (44 inch-lbf) Interior 3/4-14 NPT Thread Mounting nut included Adjacent Unit Mounting Separation Distance Minimum: 0 in (mounted with unit flanges touching) ## Indicator Characteristics **==> picture [221 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Color Coordi<br>Dominant Wavelength Lumen Output<br>Color (nm) or Color Tempera nates [(1)] (Typical at 25<br>ture (CCT) x y °C)<br> Red 620 nm 0.6900 0.3081 36<br> Green 525 nm 0.1620 0.7112 73<br> Blue 468 nm 0.1400 0.0539 14<br> Yellow 575 nm 0.4780 0.4700 91<br>Continued on page 4<br>**----- End of picture text -----**<br> (1) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. E530817 ## Supply Voltage and Current 100 V AC to 240 V AC, 50 Hz to 60 Hz Maximum current (mA AC at 60 HZ): **==> picture [222 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> Voltage Light Only Light & Audible<br> 100 102 112<br> 230 68 70<br>Continued from page 2<br>Dominant Wavelength Color Coordinates Lumen Output<br>Color (nm) or Color Tempera (Typical at 25<br>ture (CCT) x y °C)<br> Magenta 0.3877 0.1817 47<br> Cyan 492 nm 0.1666 0.3406 83<br> White 6000K 0.3379 0.3380 112<br> Amber 590 nm 0.5566 0.4098 63<br> Rose 0.5234 0.2310 39<br> Lime<br> 562 nm 0.3987 0.5306 99<br>Green<br>Continued on page 4<br>**----- End of picture text -----**<br> June 12, 2023 page 3 © Banner Engineering Corp. K100 Pro Hazardous Indicator Beacon - AC Datasheet **==> picture [221 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 3<br>Dominant Wavelength Color Coordinates Lumen Output<br>Color (nm) or Color Tempera (Typical at 25<br>ture (CCT) x y °C)<br> Orange 600 nm 0.6135 0.3665 50<br> Sky Blue 485 nm 0.1483 0.2476 87<br> Violet 0.2148 0.0938 28<br> Spring 507 nm 0.1780 0.5375 77<br>Green<br>**----- End of picture text -----**<br> Internal temperature compensation circuitry: Reduces the Lu men Output to decrease the unit's internal operating tempera ture. The amount of reduction is dependent on the ambient operating temperature, supply voltage, color, and/or audible functions being utilized. ## Required Overcurrent Protection **==> picture [32 x 42] intentionally omitted <==** WARNING: Electrical connections must be made by qualified personnel in ac cordance with local and national electri cal codes and regulations. Overcurrent protection is required to be provided by end prod uct application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. **==> picture [222 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [500 x 281] intentionally omitted <==** **----- Start of picture text -----**<br> Standard Models Audible Models<br>Ø 92.8 Ø 92.8<br>[3.65] [3.65]<br>80.9 81.0<br>[3.18] [3.19]<br>134.7 134.8<br>[5.3] [5.31]<br>25.5<br>25.5 M36 x 2.0 [1.01]<br>M36 x 2.0 [1.01]<br>Interior<br>Interior<br>T<br>13.0 1/2 - 20 13.0<br>1/2 - 20 [0.51] [0.51]<br>Ø 118.5 [4.67]<br>[4.67]<br>**----- End of picture text -----**<br> Accessories ## Cordsets All measurements are listed in millimeters, unless noted otherwise. June 12, 2023 page 4 © Banner Engineering Corp. K100 Pro Hazardous Indicator Beacon - AC Datasheet **==> picture [500 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> 5Pin 1/2in Dual Key Cordsets—Single Ended<br>Model Length Style Dimensions Pinout<br>MQAC2-506 2 m (6.56 ft)<br>MQAC2-515 5 m (16.4 ft) 3 4<br>2<br>Straight 1 5<br>MQAC2-530 9.14 m (30 ft) 1/2-20 UNF-2B 1 = Brown 2 = Blue<br>ø 14.5 3 = White<br>4 = Black<br>5 = Gray<br>**----- End of picture text -----**<br> ## Brackets **==> picture [500 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> 65 70<br>50.8<br>LMB36RA • Indicator light rightangle mounting 4 X Ø6.5 25.4<br>• 36 mm mounting hole Ø36.5<br>• Stainless steel<br>62.5<br>**----- End of picture text -----**<br> ## Elevated Mount System **==> picture [500 x 331] intentionally omitted <==** **----- Start of picture text -----**<br> Model<br>Black Anodized Alu Black Anodized Aluminum Clear Anodized Aluminum Features Components<br>minum<br>½ in. NPT ½ in. NPT<br>¾ in. NPT<br>SOP-E34-150A 150 mm SOP-E12-150A 150 mm (6 SOP-E12-150AC 150 mm<br>(6 in) long in) long (6 in) long<br>• Elevateduse standoff pipe<br>SOP-E34-300A 300 mm SOP-E12-300A 300 mm SOP-E12-300AC 300 • Black anodized aluminum or clear an<br>(12 in) long (12 in) long mm (12 in) long odized aluminum surface<br>• Threaded at both ends<br>SOP-E34-600A (24 in) long 600 mm (24 in) long SOP-E12-600A 600 mm — • Compatible with most industrial environments<br>SOP-E34-900A 900 mm SOP-E12-900A 900 mm SOP-E12-900AC 900<br>(36 in) long (36 in) long mm (36 in) long<br>• Adapter from M36 thread to 12-14 NPSM<br>thread<br>SA-M36E12 • Streamlined black plastic mounting base<br>adapter/cover<br>• Drilled hole<br>• M36 thread adapter with clearance for ¾<br>pipe mount<br>SA-M36SOP • Streamlined black plastic mounting base<br>adapter/cover<br>• Drilled hole<br>Pipe Mounting Flange<br>Model Features Construction<br>• Elevated-use stand-off pipes (½ in, NPSM/ 4x ø5.5 54<br>DN15) Die-cast zinc base with black<br>SA-F12 • M5 mounting hardware and nitrile gasket paint ø28<br>included 10 ø70<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of ship ment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the June 12, 2023 page 5 © Banner Engineering Corp. K100 Pro Hazardous Indicator Beacon - AC Datasheet factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUD ING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BAN NER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or lia bilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installa tion of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the prod uct warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other lan guage. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 6 June 12, 2023 © Banner Engineering Corp.
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →