K100PDBLRGBKQ
Indicator, IO Link, Multicolour, 30 VDC, IP66, IP69K, 134.62 mm H, 118.62 mm Lens, -40 to 50° C
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (25-Jun-2025)
- Power Rating: -
- Lens Diameter: 118.62mm
- Product Range: K100 Pro Series
- External Height: 5.3"
- IP / NEMA Rating: IP66, IP69K
- Module Lens Colour: Multicolour
- Supply Voltage VAC: -
- Supply Voltage VDC: 30V
- Visual Signal Type: Multifunction
- Operating Temperature Max: 50°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 368.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [148 x 792] intentionally omitted <==**
K100 Programmable Display Beacon with IO-Link Product Manual
Original Instructions p/n: 248445 Rev. A 02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
K100 Programmable Display Beacon with IO-Link Product Manual
## Contents
**Chapter 1 Features.................................................................................................................. 3** Models ........................................................................................................................................................................................................... 3 **Chapter 2 Wiring...................................................................................................................... 4 Chapter 3 IO-Link Process Data Out (Master to Device) ..................................................... 5 Chapter 4 Specifications .......................................................................................................11** FCC Part 15 Class B for Unintentional Radiators........................................................................................................................................ 12 Industry Canada ICES-003(B)..................................................................................................................................................................... 12 Dimensions.................................................................................................................................................................................................. 13 **Chapter 5 Accessories.......................................................................................................... 14** Cordsets ...................................................................................................................................................................................................... 14 Brackets....................................................................................................................................................................................................... 14 Elevated Mount System............................................................................................................................................................................... 15 **Chapter 6 Product Support and Maintenance .................................................................... 16** UTF-8 Encoding Table and Unicode Characters......................................................................................................................................... 16 Clean with Mild Detergent and Warm Water ............................................................................................................................................... 20 Repairs ........................................................................................................................................................................................................ 20 Contact Us................................................................................................................................................................................................... 21 Banner Engineering Corp Limited Warranty................................................................................................................................................ 21
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
K100 Programmable Display Beacon With IO-Link Product Manual
## Chapter Contents
Models.................................................................................................................................................................................................................. 3
## Chapter 1
## Features
The K100 Programmable Display Beacon with IO-Link provides diagnostics and indication for control engineers and OEMs who need to improve the interaction between operators and equipment to drive response speed and productivity improvements.
- Easily configurable, versatile display can be installed nearly anywhere, making it a simple yet powerful alternative to complex HMIs and other displays
- Great for displaying takt time, equipment status, assembly sequences, counts, and measurements where they are most useful
- IO-Link models integrate into many different systems and applications, especially Banner sensing, safety, and monitoring solutions
- Quick and easy configuration—simply define the desired text and call it via discrete control or process data
- Bright white LED display and multicolored beacon LEDs legible from 10 meters away inform operators about exactly what is going on so they can respond quickly and accurately
- IP66- and IP69K per ISO 20653-rated polycarbonate housing resists impact and condensation to provide clear communication in challenging and changing environmental conditions
- Wireless communication facilitates remote monitoring and control
## Models
## Model Key
**==> picture [492 x 63] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Series|Style|Type|Voltage|Color|Control|Audible|Connector|[(1)]|
|K100P|D|BL|RGB|K|Q|
|Blank = No|Q = Integral 4-|
|K100P = K100 Pro|D = Display|BL = Beacon Light|Blank = DC|RGB = Multicolor|K = IO-Link|Audible|pin M12 male quick-disconnect|
|A = Audible|connector|
**----- End of picture text -----**<br>
> (1) Models with a quick-disconnect connector require a mating cordset.
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 3 of 22
K100 Programmable Display Beacon With IO-Link Product Manual
## Chapter Contents
## Chapter 2
## Wiring
IO-Link Wiring
- 4-Pin Male M12 Pinout Pinout Key and Wiring 1. Brown - 12 V DC to 30 V DC
- 1
- 2 2. White - Not used 4 3. Blue - DC Common
- 3 4. Black - IO-Link Communication
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 4 of 22
K100 Programmable Display Beacon With IO-Link Product Manual
## Chapter Contents
## Chapter 3 IO-Link Process Data Out (Master to Device) SSS
IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-LINK protocol and specifications, please visit www.io-link.com.
For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com.
## Parameter Data
Use Banner's IO-Link Master to configure the Parameter Data, which can configure the device's mode, display settings, and custom configurations.
## Mode
Select the mode for the device: Run Mode (default setting), Message Mode, Measure Mode, Timer Mode, or Counter Mode.
## Additional Settings
Use Additional Settings to set the Indicator Intensity, Flash Rate, Display Intensity, and Scroll Speed to custom values that are unique from the standard options.
## Custom Color Configuration
Use Custom Color Configuration to control the colors of the indicator LEDs using RGB codes ranging from 0-255.
## Device Access Locks
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 5 of 22
K100 Programmable Display Beacon with IO-Link Product Manual
IO-Link Process Data Out (Master to Device)
Use Device Access Locks to lock or unlock Parameter Write Access and Data Storage Access.
## Display Settings
Use Display Settings to configure the color, intensity, direction, speed, scroll mode, orientation, and justification of the display text.
**==> picture [460 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|General Settings|Description|
|Display Text Color|Select either white or black display text.|
|Display Intensity|Define the intensity of the display text with a set of preset values or a custom value.|
|Display Control Direction|Select the direction the display text scrolls, using the connector as a reference.|
|Display Scroll Speed|Define the speed at which the display text scrolls using a set of preset values or a custom value.|
|Display Scroll Mode|Determine if the device scrolls the text. Auto scrolls the text for inputs longer than 16 characters.|
|Display Orientation|Select the orientation of the device, using the connector as a reference. The text and display rotate to match the device's orientation.|
|Display Justification|Select the justification of the display text between Left, Right, or Center.|
**----- End of picture text -----**<br>
## Display Deadspace Enable
Select to enable a break in the text for clearer scrolling text on the display.
## Display Deadspace Column Count
Select the number of deadspace columns at the end of the string.
## Restore Factory Settings
Use Restore Factory Settings to clear the current configurations and reset the device to its initial settings.
## Measure Base Settings
Use Measure Base Settings to configure the overall settings of the display device in Measure Mode.
**==> picture [354 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|General Settings|Description|
|Display Override|Determine if the device displays a string of text rather than the output values.|
|Override String|Determine the text that displays if Display Override is enabled.|
|Animation|Select the animation of the indicator LEDs from the animation table.|
|Color 1|Select the color of the first row of indicator LEDs.|
|Color 1 Intensity|Define the intensity of the first row of indicator LEDs.|
|Configuration Speed|Define the speed of the animation.|
|Pulse Pattern|Select the pulse pattern of the indicator LEDs: Normal, Strobe, Three Pulse, SOS, or Random.|
|Color 2|Select the color of the first row of indicator LEDs.|
|Color 2 Intensity|Define the intensity of the first row of indicator LEDs.|
**----- End of picture text -----**<br>
## Configuration Audible Volume
Select the volume of the audible on the device.
page 6 of 22
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
02-Sep-25
IO-Link Process Data Out (Master to Device)
K100 Programmable Display Beacon with IO-Link Product Manual
## Measure Mode Settings
Use the Process Data to display the measurement values. Options include either the raw input values or the scaled values.
**==> picture [488 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|General Settings|Description|
|Filtering|The level of filtering used to minimize the effects of noise on the output.|
|Hysteresis|The level of lag between the measurement thresholds to minimize the flickering at switch points.|
|Measure/Timer/Counter Mode Data Label|Text that displays before the Measure/Timer/Counter value. This setting carries through all three modes.|
|Measure/Timer/Counter Mode Bar Graph|Display the bar graph across the full display. This setting carries through all three modes.|
|Output Scale Value Low|The low-end value of the output translated from the input frequency.|
|Output Scale Value High|The high-end value of the output translated from the input frequency.|
|Input Scale Value Low|The lowest frequency of the input range.|
|Input Scale Value High|The highest frequency of the input range.|
|Measure/Timer/Counter Mode Value Label|Text that displays after the Measure/Timer/Count value to indicate the units displayed. This can be up to three|
|characters. This setting carries through all three modes.|
|Measure General Configuration.Measure/Timer/Counter Mode|
|Determine the orientation of the bar graph, using the connector as a reference.|
|Display Orientation|
|Measure General Configuration.Measure/Timer/Counter Mode|
|Display the bar graph as a single line of LEDs.|
|Display Minimal Bar Graph|
|Measure General Configuration.Measure/Timer/Counter Mode|
|Decimal Places|Determine the number of decimal places displayed on the Count Value.|
|Measure General Configuration.Measure/Timer/Counter Mode|
|Display the time in HH:MM:SS format without data labels.|
|Display as Time|
**----- End of picture text -----**<br>
## Message Mode
Use Message Mode to create and save thirteen display messages.
## Threshold Settings
Use Threshold Settings to configure the thresholds using in Measure Mode, Timer Mode, and Counter Mode. Four of these thresholds can be set individually.
02-Sep-25
© Banner Engineering Corp. All rights reserved.
page 7 of 22
www.bannerengineering.com
K100 Programmable Display Beacon with IO-Link Product Manual
IO-Link Process Data Out (Master to Device)
|General Settings<br>Description<br>Threshold Enable<br>Determine if thresholds will be used to change the output at various levels.<br>Threshold Value<br>Define the percentage of the overall value that sets the threshold based on the threshold number used.<br>Threshold Comparison<br>Determine if this threshold is in use for values greater than or less than the Threshold Value.<br>Threshold Override<br>Determine the precedence of the thresholds that have overlapping criteria.|
|---|
|General Settings<br>Description<br>Display Override<br>Determine if the device displays a string of text rather than the output values.<br>Override String<br>Determine the text that displays if Display Override is enabled.<br>Animation<br>Select the animation of the indicator LEDs from the animation table.<br>Color<br>Select the color of the indicator LEDs.<br>Color Intensity<br>Define the intensity of the indicator LEDs.<br>Configuration Speed<br>Define the speed of the animation.<br>Pulse Pattern<br>Select the pulse pattern of the indicator LEDs: Normal, Strobe, Three Pulse, SOS, or Random.|
## Timer Mode
Use Timer Mode to count up to or down from a determined value. For additional timer settings, refer to the table in Measure Mode Settings.
General Settings Description Timer Value The total time of the timer. Timer Unit Type Select the units of the timer. Up: Counts up from zero to Count Seconds. Timer Count Type Down: Counts down from Count Seconds to zero. Enable Auto Reload The timer loops back to the original value automatically when it reaches its final value.
## Counter Mode
Counter Mode uses parameter settings found in Measure Mode Settings to configure the output of the device. For more detail, refer to the table in Measure Mode Settings.
## Demo Mode
Demo sequence cycles through twelve different configurations to highlight example applications.
## Process Data
page 8 of 22
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
02-Sep-25
IO-Link Process Data Out (Master to Device)
K100 Programmable Display Beacon with IO-Link Product Manual
Process Data is used to implement the data to run the device. With Process Data, the selection menu changes based on the Mode Selection written to the device.
## Run Mode
## Message Mode
## Measure Mode
02-Sep-25
© Banner Engineering Corp. All rights reserved.
page 9 of 22
www.bannerengineering.com
K100 Programmable Display Beacon with IO-Link Product Manual
IO-Link Process Data Out (Master to Device)
## Timer Mode
## Counter Mode
## Indicator LED Animations
**==> picture [484 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Animation|Description|
|Off|Indication LEDs are off.|
|Steady|Color 1 is solid on at a defined intensity.|
|Flash|Color 1 flashes alternately at defined speed, color intensities, and pattern (Normal, Strobe, Three Pulse, SOS, or Random).|
|Two Color Flash|Color 1 and Color 2 flash alternately at defined speed, color intensities, and pattern (Normal, Strobe, Three Pulse, SOS, or Random).|
|50/50|Color 1 and Color 2 are solid at a defined intensity.|
|50/50 Flash|Color 1 and Color 2 flash at a defined speed, color intensity, and pattern (Normal, Strobe, Three Pulse, SOS, or Random).|
|Intensity Sweep|Color 1 repeatedly increases and decreases intensity between 0% to 100% at defined speed and color intensity.|
|Color 1 and Color 2 define the end values of a line across the color gamut. The light continuously displays a color by moving along the line at the|
|Two Color Sweep|
|defined speed and color intensities.|
**----- End of picture text -----**<br>
page 10 of 22
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
02-Sep-25
K100 Programmable Display Beacon With IO-Link Product Manual
## Chapter Contents
|FCC Part 15 Class B for Unintentional Radiators .............................................................................................................................................. 12|
|---|
|Industry Canada ICES-003(B)............................................................................................................................................................................ 12|
|Dimensions......................................................................................................................................................................................................... 13|
|Specifications<br>Chapter 4|
## Specifications
Supply Voltage 18 V DC to 30 V DC
Use only with a suitable Class 2 power supply (UL) or SELV power supply (CE)
Supply Current 350 mA max. at 18 V DC 270 mA max. at 24 V DC
220 mA max. at 30 V DC
Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Indicator Response Time On response: 325 ms (max) Off response: 20 ms (max) Connections Integral 4-pin M12 male quick-disconnect connector Models with a quick-disconnect connector require a mating cordset Do not spray cable with high-pressure sprayer or cable damage will result
Operating Temperature –40 °C to +50 °C (–40 °F to +122 °F) Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F) Environmental Rating Rated IP66 and IP69K per ISO 20653 UL Type 4X
Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Impact: IK10 (60068-2-75) Audible Characteristics Sound Intensity at 2.5 KHz, at 1 m (typical): Low volume setting: 93 dB Medium volume setting: 96 dB High volume setting: 101 dB
## Character Limit
Run Mode: 29 characters All other modes: 32 characters Construction Black polycarbonate housing Smoky polycarbonate dome Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 CE 1831 Diegem, BELGIUM
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com.
|Supply<br>Wiring<br>(AWG)<br>20|Required Overcurrent<br>Protection (A)<br>5.0|Supply<br>Wiring<br>(AWG)<br>26|Required Overcurrent<br>Protection (A)<br>1.0|
|---|---|---|---|
|22|3.0|28|0.8|
|24|2.0|30|0.5|
## Mounting
M36 x 2 threaded base, maximum torque 5 N·m (44 inch-lbf) Interior 3/4-14 NPT thread Mounting nut included
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 11 of 22
K100 Programmable Display Beacon with IO-Link Product Manual
Specifications
## Indicator Characteristics
**==> picture [483 x 264] intentionally omitted <==**
**----- Start of picture text -----**<br>
Color Coordinates [(2)]<br>Dominant Wavelength (nm) or Color Lumen Output (Typical at 25<br>Color<br>Temperature (CCT) x y °C)<br>Green 523 0.159 0.6987 30.4<br>Red 620 0.6895 0.3087 14.6<br>Orange 599 0.5992 0.3752 17.7<br>Amber 588 0.535 0.4223 19.8<br>Yellow 575 0.4518 0.4834 22.4<br>Lime Green 560 0.3655 0.5471 25<br>Spring Green 506 0.1572 0.5171 26.6<br>Cyan 491 0.1565 0.3201 21.3<br>Sky Blue 484 0.1443 0.2271 16.8<br>Blue 467 0.1371 0.0555 5.4<br>Violet 415 0.2141 0.0904 7.9<br>Magenta - 0.3661 0.1644 11.4<br>Rose - 0.4976 0.2201 12.9<br>White 5500K 0.3309 0.3385 41.7<br>**----- End of picture text -----**<br>
## FCC Part 15 Class B for Unintentional Radiators
(Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
(Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
## Industry Canada ICES-003(B)
This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif.
> (2) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. Actual coordinates may differ by 10%.
page 12 of 22
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
02-Sep-25
K100 Programmable Display Beacon with IO-Link Product Manual
Specifications
## Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change.
**==> picture [500 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
Standard Models Audible Models<br>Ø 92.8 Ø 92.8<br>[3.65] [3.65]<br>80.9 81.0<br>[3.18] [3.19]<br>134.7 134.8<br>[5.3] [5.31]<br>25.5<br>25.5 M36 x 2.0 [1.01]<br>M36 x 2.0 [1.01]<br>Interior<br>Interior 3/4 - 14 NPT<br>3/4 - 14 NPT<br>13.0 M12 x 1.0 13.0<br>M12 x 1.0 [0.51] [0.51]<br>Ø 118.5<br>Ø 118.5 [4.67]<br>[4.67]<br>**----- End of picture text -----**<br>
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 13 of 22
K100 Programmable Display Beacon With IO-Link Product Manual
## Chapter Contents
Cordsets ............................................................................................................................................................................................................. 14 Brackets ............................................................................................................................................................................................................. 14 Elevated Mount System ..................................................................................................................................................................................... 15
## Chapter 5
## Accessories
## Cordsets
**==> picture [500 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
4-pin A-Code Double-Ended M12 Female to M12 Male Cordsets<br>Model Length Dimensions (mm) Pinouts<br>BC-M12F4-M12M4-22-1 1 m (3.28 ft) Female<br>BC-M12F4-M12M4-22-2 2 m (6.56 ft) 40 Typ.[1.58"] 1 2<br>3<br>BC-M12F4-M12M4-22-3 3 m (9.84 ft) M12 x 1 4 1 = Brown<br>BC-M12F4-M12M4-22-4 4 m (13.12 ft) ø 14.5 [0.57"] 2 = White<br>44 Typ. Male 3 = Blue<br>BC-M12F4-M12M4-22-5 5 m (16.4 ft) [1.73"] 4 = Black<br>1<br>BC-M12F4-M12M4-22-10 10 m (30.81 ft) M12 x 1 2<br>ø 14.5 [0.57"] 4<br>BC-M12F4-M12M4-22-15 15 m (49.2 ft) 3<br>**----- End of picture text -----**<br>
## Brackets
**==> picture [433 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
65 70<br>50.8<br>• Indicator light right-angle mounting 4 X Ø6.5 25.4<br>• 36 mm mounting hole Ø36.5<br>• Stainless steel 62.5<br>**----- End of picture text -----**<br>
## LMB36RA
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 14 of 22
K100 Programmable Display Beacon with IO-Link Product Manual
Accessories
## Elevated Mount System
## Elevated Mount System (1/2" Pipes)
**==> picture [500 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
Adapter/Cover Model Description<br>• Adapter from M36 thread to ½-14 NPSM thread<br>SA-M36E12 • Streamlined black plastic mounting base adapter/cover<br>• Drilled hole<br>Black Anodized Aluminum, ½ in. NPT Pipe Clear Anodized Aluminum, ½ in. NPT Pipe<br>Models Models Description<br>Pipe<br>SOP-E12-150A , 150 mm (6 in) long SOP-E12-150AC , 150 mm (6 in) long<br>• Elevated-use stand-off pipe<br>SOP-E12-300A , 300 mm (12 in) long SOP-E12-300AC , 300 mm (12 in) long • Threaded at both ends<br>SOP-E12-600A , 600 mm (24 in) long - • Compatible with most industrial environments<br>SOP-E12-900A , 900 mm (36 in) long SOP-E12-900AC , 900 mm (36 in) long<br>Mounting Base Model Description<br>• Elevated-use stand-off pipes (½ in, NPSM/DN15)<br>SA-F12 • M5 mounting hardware and nitrile gasket included<br>• Die-cast zinc base with black paint<br>**----- End of picture text -----**<br>
## Elevated Mount System (3/4" Pipes)
**==> picture [500 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
Adapter/Cover Model Description<br>Adapter/ • M36 thread adapter with clearance for ¾ pipe mount<br>Cover SA-M36SOP • Streamlined black plastic mounting base adapter/cover<br>• Drilled hole<br>Pipe Black Anodized Aluminum, ¾ in. NPT Pipe Models Description<br>SOP-E34-150A , 150 mm (6 in) long<br>SOP-E34-300A , 300 mm (12 in) long •• Elevated-use stand-off pipeThreaded at both ends<br>SOP-E34-600A , 600 mm (24 in) long • Compatible with most industrial environments<br>SOP-E34-900A , 900 mm (36 in) long<br>**----- End of picture text -----**<br>
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 15 of 22
K100 Programmable Display Beacon With IO-Link Product Manual
## Chapter Contents
|UTF-8 Encoding Table and Unicode Characters................................................................................................................................................ 16|
|---|
|Clean with Mild Detergent and Warm Water ...................................................................................................................................................... 20|
|Repairs ............................................................................................................................................................................................................... 20|
|Contact Us.......................................................................................................................................................................................................... 21|
|Banner Engineering Corp Limited Warranty....................................................................................................................................................... 21|
|Product Support and Maintenance<br>Chapter 6|
## UTF-8 Encoding Table and Unicode Characters
**==> picture [500 x 491] intentionally omitted <==**
**----- Start of picture text -----**<br>
Unicode Code Point Character UTF-8 (hex.) Name<br>U+0020 20 SPACE<br>U+0021 ! 21 EXCLAMATION MARK<br>U+0022 " 22 QUOTATION MARK<br>U+0023 # 23 NUMBER SIGN<br>U+0024 $ 24 DOLLAR SIGN<br>U+0025 % 25 PERCENT SIGN<br>U+0026 & 26 AMPERSAND<br>U+0027 ' 27 APOSTROPHE<br>U+0028 ( 28 LEFT PARENTHESIS<br>U+0029 ) 29 RIGHT PARENTHESIS<br>U+002A * 2a ASTERISK<br>U+002B + 2b PLUS SIGN<br>U+002C , 2c COMMA<br>U+002D - 2d HYPHEN-MINUS<br>U+002E . 2e FULL STOP<br>U+002F / 2f SOLIDUS<br>U+0030 0 30 DIGIT ZERO<br>U+0031 1 31 DIGIT ONE<br>U+0032 2 32 DIGIT TWO<br>U+0033 3 33 DIGIT THREE<br>U+0034 4 34 DIGIT FOUR<br>U+0035 5 35 DIGIT FIVE<br>U+0036 6 36 DIGIT SIX<br>U+0037 7 37 DIGIT SEVEN<br>U+0038 8 38 DIGIT EIGHT<br>U+0039 9 39 DIGIT NINE<br>U+003A : 3a COLON<br>U+003B ; 3b SEMICOLON<br>U+003C < 3c LESS-THAN SIGN<br>U+003D = 3d EQUALS SIGN<br>U+003E > 3e GREATER-THAN SIGN<br>Continued on page 17<br>**----- End of picture text -----**<br>
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 16 of 22
K100 Programmable Display Beacon with IO-Link Product Manual
Product Support and Maintenance
**==> picture [500 x 663] intentionally omitted <==**
**----- Start of picture text -----**<br>
Continued from page 16<br>Unicode Code Point Character UTF-8 (hex.) Name<br>U+003F ? 3f QUESTION MARK<br>U+0040 @ 40 COMMERCIAL AT<br>U+0041 A 41 LATIN CAPITAL LETTER A<br>U+0042 B 42 LATIN CAPITAL LETTER B<br>U+0043 C 43 LATIN CAPITAL LETTER C<br>U+0044 D 44 LATIN CAPITAL LETTER D<br>U+0045 E 45 LATIN CAPITAL LETTER E<br>U+0046 F 46 LATIN CAPITAL LETTER F<br>U+0047 G 47 LATIN CAPITAL LETTER G<br>U+0048 H 48 LATIN CAPITAL LETTER H<br>U+0049 I 49 LATIN CAPITAL LETTER I<br>U+004A J 4a LATIN CAPITAL LETTER J<br>U+004B K 4b LATIN CAPITAL LETTER K<br>U+004C L 4c LATIN CAPITAL LETTER L<br>U+004D M 4d LATIN CAPITAL LETTER M<br>U+004E N 4e LATIN CAPITAL LETTER N<br>U+004F O 4f LATIN CAPITAL LETTER O<br>U+0050 P 50 LATIN CAPITAL LETTER P<br>U+0051 Q 51 LATIN CAPITAL LETTER Q<br>U+0052 R 52 LATIN CAPITAL LETTER R<br>U+0053 S 53 LATIN CAPITAL LETTER S<br>U+0054 T 54 LATIN CAPITAL LETTER T<br>U+0055 U 55 LATIN CAPITAL LETTER U<br>U+0056 V 56 LATIN CAPITAL LETTER V<br>U+0057 W 57 LATIN CAPITAL LETTER W<br>U+0058 X 58 LATIN CAPITAL LETTER X<br>U+0059 Y 59 LATIN CAPITAL LETTER Y<br>U+005A Z 5a LATIN CAPITAL LETTER Z<br>U+005B [ 5b LEFT SQUARE BRACKET<br>U+005C \ 5c REVERSE SOLIDUS<br>U+005D ] 5d RIGHT SQUARE BRACKET<br>U+005E ^ 5e CIRCUMFLEX ACCENT<br>U+005F _ 5f LOW LINE<br>U+0060 ` 60 GRAVE ACCENT<br>U+0061 a 61 LATIN SMALL LETTER A<br>U+0062 b 62 LATIN SMALL LETTER B<br>U+0063 c 63 LATIN SMALL LETTER C<br>U+0064 d 64 LATIN SMALL LETTER D<br>U+0065 e 65 LATIN SMALL LETTER E<br>U+0066 f 66 LATIN SMALL LETTER F<br>U+0067 g 67 LATIN SMALL LETTER G<br>U+0068 h 68 LATIN SMALL LETTER H<br>Continued on page 18<br>**----- End of picture text -----**<br>
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 17 of 22
K100 Programmable Display Beacon with IO-Link Product Manual
Product Support and Maintenance
**==> picture [500 x 663] intentionally omitted <==**
**----- Start of picture text -----**<br>
Continued from page 17<br>Unicode Code Point Character UTF-8 (hex.) Name<br>U+0069 i 69 LATIN SMALL LETTER I<br>U+006A j 6a LATIN SMALL LETTER J<br>U+006B k 6b LATIN SMALL LETTER K<br>U+006C l 6c LATIN SMALL LETTER L<br>U+006D m 6d LATIN SMALL LETTER M<br>U+006E n 6e LATIN SMALL LETTER N<br>U+006F o 6f LATIN SMALL LETTER O<br>U+0070 p 70 LATIN SMALL LETTER P<br>U+0071 q 71 LATIN SMALL LETTER Q<br>U+0072 r 72 LATIN SMALL LETTER R<br>U+0073 s 73 LATIN SMALL LETTER S<br>U+0074 t 74 LATIN SMALL LETTER T<br>U+0075 u 75 LATIN SMALL LETTER U<br>U+0076 v 76 LATIN SMALL LETTER V<br>U+0077 w 77 LATIN SMALL LETTER W<br>U+0078 x 78 LATIN SMALL LETTER X<br>U+0079 y 79 LATIN SMALL LETTER Y<br>U+007A z 7a LATIN SMALL LETTER Z<br>U+007B { 7b LEFT CURLY BRACKET<br>U+007C | 7c VERTICAL LINE<br>U+007D } 7d RIGHT CURLY BRACKET<br>U+007E ~ 7e TILDE<br>U+00A0 c2 a0 NO-BREAK SPACE<br>U+00A1 ¡ c2 a1 INVERTED EXCLAMATION MARK<br>U+00A2 ¢ c2 a2 CENT SIGN<br>U+00A3 £ c2 a3 POUND SIGN<br>U+00A4 ¤ c2 a4 CURRENCY SIGN<br>U+00A5 ¥ c2 a5 YEN SIGN<br>U+00A6 ¦ c2 a6 BROKEN BAR<br>U+00A7 § c2 a7 SECTION SIGN<br>U+00A8 ¨ c2 a8 DIAERESIS<br>U+00A9 © c2 a9 COPYRIGHT SIGN<br>U+00AA ª c2 aa FEMININE ORDINAL INDICATOR<br>U+00AB « c2 ab LEFT-POINTING DOUBLE ANGLE QUOTATION MARK<br>U+00AC ¬ c2 ac NOT SIGN<br>U+00AD c2 ad SOFT HYPHEN<br>U+00AE ® c2 ae REGISTERED SIGN<br>U+00AF ¯ c2 af MACRON<br>U+00B0 ° c2 b0 DEGREE SIGN<br>U+00B1 ± c2 b1 PLUS-MINUS SIGN<br>U+00B2 ² c2 b2 SUPERSCRIPT TWO<br>U+00B3 ³ c2 b3 SUPERSCRIPT THREE<br>Continued on page 19<br>**----- End of picture text -----**<br>
page 18 of 22
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
02-Sep-25
K100 Programmable Display Beacon with IO-Link Product Manual
Product Support and Maintenance
**==> picture [500 x 663] intentionally omitted <==**
**----- Start of picture text -----**<br>
Continued from page 18<br>Unicode Code Point Character UTF-8 (hex.) Name<br>U+00B4 ´ c2 b4 ACUTE ACCENT<br>U+00B5 µ c2 b5 MICRO SIGN<br>U+00B6 ¶ c2 b6 PILCROW SIGN<br>U+00B7 · c2 b7 MIDDLE DOT<br>U+00B8 ¸ c2 b8 CEDILLA<br>U+00B9 ¹ c2 b9 SUPERSCRIPT ONE<br>U+00BA º c2 ba MASCULINE ORDINAL INDICATOR<br>U+00BB » c2 bb RIGHT-POINTING DOUBLE ANGLE QUOTATION MARK<br>U+00BC ¼ c2 bc VULGAR FRACTION ONE QUARTER<br>U+00BD ½ c2 bd VULGAR FRACTION ONE HALF<br>U+00BE ¾ c2 be VULGAR FRACTION THREE QUARTERS<br>U+00BF ¿ c2 bf INVERTED QUESTION MARK<br>U+00C0 À c3 80 LATIN CAPITAL LETTER A WITH GRAVE<br>U+00C1 Á c3 81 LATIN CAPITAL LETTER A WITH ACUTE<br>U+00C2 Â c3 82 LATIN CAPITAL LETTER A WITH CIRCUMFLEX<br>U+00C3 Ã c3 83 LATIN CAPITAL LETTER A WITH TILDE<br>U+00C4 Ä c3 84 LATIN CAPITAL LETTER A WITH DIAERESIS<br>U+00C5 Å c3 85 LATIN CAPITAL LETTER A WITH RING ABOVE<br>U+00C6 Æ c3 86 LATIN CAPITAL LETTER AE<br>U+00C7 Ç c3 87 LATIN CAPITAL LETTER C WITH CEDILLA<br>U+00C8 È c3 88 LATIN CAPITAL LETTER E WITH GRAVE<br>U+00C9 É c3 89 LATIN CAPITAL LETTER E WITH ACUTE<br>U+00CA Ê c3 8a LATIN CAPITAL LETTER E WITH CIRCUMFLEX<br>U+00CB Ë c3 8b LATIN CAPITAL LETTER E WITH DIAERESIS<br>U+00CC Ì c3 8c LATIN CAPITAL LETTER I WITH GRAVE<br>U+00CD Í c3 8d LATIN CAPITAL LETTER I WITH ACUTE<br>U+00CE Î c3 8e LATIN CAPITAL LETTER I WITH CIRCUMFLEX<br>U+00CF Ï c3 8f LATIN CAPITAL LETTER I WITH DIAERESIS<br>U+00D0 Ð c3 90 LATIN CAPITAL LETTER ETH<br>U+00D1 Ñ c3 91 LATIN CAPITAL LETTER N WITH TILDE<br>U+00D2 Ò c3 92 LATIN CAPITAL LETTER O WITH GRAVE<br>U+00D3 Ó c3 93 LATIN CAPITAL LETTER O WITH ACUTE<br>U+00D4 Ô c3 94 LATIN CAPITAL LETTER O WITH CIRCUMFLEX<br>U+00D5 Õ c3 95 LATIN CAPITAL LETTER O WITH TILDE<br>U+00D6 Ö c3 96 LATIN CAPITAL LETTER O WITH DIAERESIS<br>U+00D7 × c3 97 MULTIPLICATION SIGN<br>U+00D8 Ø c3 98 LATIN CAPITAL LETTER O WITH STROKE<br>U+00D9 Ù c3 99 LATIN CAPITAL LETTER U WITH GRAVE<br>U+00DA Ú c3 9a LATIN CAPITAL LETTER U WITH ACUTE<br>U+00DB Û c3 9b LATIN CAPITAL LETTER U WITH CIRCUMFLEX<br>U+00DC Ü c3 9c LATIN CAPITAL LETTER U WITH DIAERESIS<br>U+00DD Ý c3 9d LATIN CAPITAL LETTER Y WITH ACUTE<br>Continued on page 20<br>**----- End of picture text -----**<br>
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 19 of 22
K100 Programmable Display Beacon with IO-Link Product Manual
Product Support and Maintenance
**==> picture [500 x 534] intentionally omitted <==**
**----- Start of picture text -----**<br>
Continued from page 19<br>Unicode Code Point Character UTF-8 (hex.) Name<br>U+00DE Þ c3 9e LATIN CAPITAL LETTER THORN<br>U+00DF ß c3 9f LATIN SMALL LETTER SHARP S<br>U+00E0 à c3 a0 LATIN SMALL LETTER A WITH GRAVE<br>U+00E1 á c3 a1 LATIN SMALL LETTER A WITH ACUTE<br>U+00E2 â c3 a2 LATIN SMALL LETTER A WITH CIRCUMFLEX<br>U+00E3 ã c3 a3 LATIN SMALL LETTER A WITH TILDE<br>U+00E4 ä c3 a4 LATIN SMALL LETTER A WITH DIAERESIS<br>U+00E5 å c3 a5 LATIN SMALL LETTER A WITH RING ABOVE<br>U+00E6 æ c3 a6 LATIN SMALL LETTER AE<br>U+00E7 ç c3 a7 LATIN SMALL LETTER C WITH CEDILLA<br>U+00E8 è c3 a8 LATIN SMALL LETTER E WITH GRAVE<br>U+00E9 é c3 a9 LATIN SMALL LETTER E WITH ACUTE<br>U+00EA ê c3 aa LATIN SMALL LETTER E WITH CIRCUMFLEX<br>U+00EB ë c3 ab LATIN SMALL LETTER E WITH DIAERESIS<br>U+00EC ì c3 ac LATIN SMALL LETTER I WITH GRAVE<br>U+00ED í c3 ad LATIN SMALL LETTER I WITH ACUTE<br>U+00EE î c3 ae LATIN SMALL LETTER I WITH CIRCUMFLEX<br>U+00EF ï c3 af LATIN SMALL LETTER I WITH DIAERESIS<br>U+00F0 ð c3 b0 LATIN SMALL LETTER ETH<br>U+00F1 ñ c3 b1 LATIN SMALL LETTER N WITH TILDE<br>U+00F2 ò c3 b2 LATIN SMALL LETTER O WITH GRAVE<br>U+00F3 ó c3 b3 LATIN SMALL LETTER O WITH ACUTE<br>U+00F4 ô c3 b4 LATIN SMALL LETTER O WITH CIRCUMFLEX<br>U+00F5 õ c3 b5 LATIN SMALL LETTER O WITH TILDE<br>U+00F6 ö c3 b6 LATIN SMALL LETTER O WITH DIAERESIS<br>U+00F7 ÷ c3 b7 DIVISION SIGN<br>U+00F8 ø c3 b8 LATIN SMALL LETTER O WITH STROKE<br>U+00F9 ù c3 b9 LATIN SMALL LETTER U WITH GRAVE<br>U+00FA ú c3 ba LATIN SMALL LETTER U WITH ACUTE<br>U+00FB û c3 bb LATIN SMALL LETTER U WITH CIRCUMFLEX<br>U+00FC ü c3 bc LATIN SMALL LETTER U WITH DIAERESIS<br>U+00FD ý c3 bd LATIN SMALL LETTER Y WITH ACUTE<br>U+00FE þ c3 be LATIN SMALL LETTER THORN<br>U+00FF ÿ c3 bf LATIN SMALL LETTER Y WITH DIAERESIS<br>**----- End of picture text -----**<br>
## Clean with Mild Detergent and Warm Water
Wipe down the device with a soft cloth dampened with a mild detergent and warm water solution. Do not use any other chemicals for cleaning.
## Repairs
Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. If the device, device part, or device component is determined to be defective by a Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure.
page 20 of 22
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
02-Sep-25
K100 Programmable Display Beacon with IO-Link Product Manual
Product Support and Maintenance
IMPORTANT: If instructed to return the device, pack it with care. Damage that occurs in return shipping is not covered by warranty.
## Contact Us
Banner Engineering Corp. | 9714 Tenth Avenue North | Plymouth, MN 55441, USA | Phone: + 1 888 373 6767
For worldwide locations and local representatives, visit www.bannerengineering.com.
## Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
02-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 21 of 22
## LinkedIn
## X (formerly Twitter)
## Facebook
© 2025. All rights reserved. www.bannerengineering.com
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →