K100PBLRQ
VISUAL SIGNAL INDICATOR UNITS
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 277.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
K100 Pro Daylight Visible Beacon (DC) ## Features High Daylight Visibility, Programmable Multicolor Indicator with Optional Audible Alarm for Indoor or Outdoor Use - Highly visible indicator provides bright, even light in direct sunlight - • Three colors in one device • Programmable using Banner's Pro Editor software and Pro Converter Cable • 36 mm threaded polycarbonate base • Rugged IP66 and IP69K per ISO 20653, UL Type 4X housing • PNP or NPN operation depending on wiring • Variety of connector options • Rugged UV-stabilized polycarbonate base and window • 12 V DC to 48 V DC operating voltage ## Pro Editor Use Banner's Pro Editor software and Pro Converter Cable to create custom configurations by selecting different colors, flash patterns, and animations. For more information visit www.bannerengineering.com/proeditor. ## Full Preview Connection (Required) The full preview connection must be used for the K100 Pro Beacon. **==> picture [483 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> A = Pro Converter Cable (MQDC-506-USB)<br>B = Splitter (CSB-M1251FM1251M)<br>C = PC running Pro Editor software<br>D = Any Banner Pro Series-enabled device (K50 shown)<br>E E = Power Supply (PSW-24-1, PSW-24-2, or PSD-24-4)<br>F = 8-Pin to 5-Pin Double-Ended Cordset (MQDC-801-5M-PRO), required<br>for 8-Pin models<br>A<br>5 ce Be =<br>i —— C<br>o<br>r D<br>B<br>:— F a<br>**----- End of picture text -----**<br> ## Models Standard models shown. Contact factory for other options. Three Color Models. Other available color options: Blue and White **==> picture [444 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> Family Style Type Color 1 Color 2 Color 3 Audible Connector [(1)]<br>K100 P BL G Y R A Q<br>Continued on page 2<br>**----- End of picture text -----**<br> (1) Models with a quick-disconnect connector require a mating cordset. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com Original Instructions 02-Sep-25 p/n: 225026 Rev. F K100 Pro Daylight Visible Beacon (DC) **==> picture [500 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 1<br>Family Style Type Color 1 Color 2 Color 3 Audible Connector<br>Blank = 2 m (6.5 ft) integral PVC-<br>jacketed cable<br>Blank = None Q = Integral 5-pin M12 male quick-<br>P = Pro BL = Beacon G = Green Y = Yellow R = Red disconnect connector<br>A = Audible<br>QP = 150 mm (6 in) PVC-jacketed<br>cable with a 5-pin M12 male quick-<br>disconnect connector<br>One Color Models. Other available color option: Red<br>Family Style Type Color Audible Connector<br>K100 P BL Y A Q<br>Blank = 2 m (6.5 ft) integral PVC-jacketed cable<br>Blank = None<br>P = Pro BL = Beacon Y = Yellow Q = Integral 5-pin M12 male quick-disconnect connector<br>A = Audible<br>QP = 150 mm (6 in) PVC-jacketed cable with a 5-pin M12 male quick-disconnect<br>connector<br>**----- End of picture text -----**<br> ## Wiring **==> picture [500 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> PNP Input NPN Input Key<br>bu (3) bu (3)<br>bk (4) 12–48 V DC bk (4) 12-48 V DC<br>1 1<br>1 = Brown<br>bn (1) bn (1) 2 = White<br>2 2 3 = Blue<br>4 = Black<br>wh (2) wh (2) 5 = Gray<br>3 3<br>gy (5) gy (5)<br>A A<br>**----- End of picture text -----**<br> An "X" denotes an active input. For example: When Input 1 and Input 3 are both active, the indicator will be Color 1 Flashing at 1 Hz. ## Default Configuration: Three Color Models **==> picture [500 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> Wiring Operating Mode/Function<br>Black Brown White Gray<br>(Input Non-Audible Audible<br>(Input 1) (Input 2) (Input 3)<br>4)<br>X Color 1 Steady Color 1 Steady<br>X Color 2 Steady Color 2 Steady<br>X Color 3 Steady Color 3 Steady<br>X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz<br>X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz<br>X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz<br>X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe<br>X Off Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 1 Steady Color 1 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 2 Steady Color 2 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 3 Steady Color 3 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>Continued on page 3<br>**----- End of picture text -----**<br> page 2 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 02-Sep-25 K100 Pro Daylight Visible Beacon (DC) **==> picture [500 x 340] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 2<br>Wiring Operating Mode/Function<br>Black Brown White Gray<br>(Input Non-Audible Audible<br>(Input 1) (Input 2) (Input 3)<br>4)<br>X X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe, Audible Steady, Frequency 2.5 KHz, Volume High<br>Default Configuration: One Color Models<br>Wiring Operating Mode/Function<br>Black Brown White Gray<br>(Input Non-Audible Audible<br>(Input 1) (Input 2) (Input 3)<br>4)<br>X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz<br>X Color 1 Steady Color 1 Steady<br>X Color 1 Rotate Color 1 Rotate<br>X X Color 1 Flashing at 5 Hz Color 1 Flashing at 5 Hz<br>X X Color 1 Flashing at 0.5 Hz Color 1 Flashing at 0.5 Hz<br>X X Color 1 Strobe Color 1 Strobe<br>X X X Color 1, 3-pulse Strobe Color 1, 3-pulse Strobe<br>X Off Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 1 Steady Color 1 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 1 Rotate Color 1 Rotate, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 1 Flashing at 5 Hz Color 1 Flashing at 5 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 1 Flashing at 0.5 Hz Color 1 Flashing at 0.5 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 1 Strobe Color 1 Strobe, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X X Color 1, 3-pulse Strobe Color 1, 3-pulse Strobe, Audible Steady, Frequency 2.5 KHz, Volume High<br>**----- End of picture text -----**<br> ## Specifications ## Supply Voltage and Current ## 12 V DC to 48 V DC Product approved with usage of Class 1 or Class 3 Power Supply to achieve Class 2 Power Supply status Use only with a suitable Class 2 power supply (North America) **==> picture [221 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum Current (mA)<br>Steady On, Flash, or Strobe Rotate Function<br>Function [(2)]<br>Supply<br>Voltage (V Light & Light &<br>DC) Light Only Audible Light Only Audible<br>12 760 820 365 435<br>18 495 530 235 275<br>24 395 425 185 220<br>30 340 365 165 195<br>36 305 330 150 180<br>42 280 305 145 170<br>48 260 285 140 165<br>**----- End of picture text -----**<br> ## Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA (2) Flash or Strobe Mode: Peak current, operating at 50% duty cycle or less. ## Indicator Response Time On response: 325 ms (max) Off response: 20 ms (max) ## Connections Integral 5-pin M12 male quick-disconnect connector, 150 mm (6 in) PVC-jacketed cable with an M12 quick disconnect, or 2 m (6.5 ft) integral PVC-jacketed cable, depending on model Models with a quick disconnect require a mating cordset ## Mounting - M36 by 2.0 threaded base, maximum torque 5.0 N·m (44 inch-lbf) Interior 3/4-14 NPT Thread Mounting nut included ## Adjacent Unit Mounting Separation Distance Minimum: 0 in (mounted with unit flanges touching) ## Audible Characteristics Sound Intensity at 2.5 KHz, at 1 m (typical): Low volume setting: 93 dB Medium volume setting: 96 dB High volume setting: 101 dB ## Construction Base, Dome, and Nut: Polycarbonate ## Operating Conditions - –40 °C to +60 °C (–40 °F to +140 °F) - 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) 02-Sep-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 8 K100 Pro Daylight Visible Beacon (DC) ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) Impact: IK10 (60068-2-75) ## Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Environmental Rating IP66, IP69K per ISO 20653, UL Type 4X LED Lifetime Lumen maintenance L70 When operating within specifications, output decreases less than 30% after 42,000 hours Pro Editor Configuration Connection to Pro Editor software enables control of: - Animation: On, Flash, Rotate, Two Color Flash, Two Color Cycle, Intensity Sweep - Color: Green, Yellow, Red, Blue, White - • Wiring: See "Wiring" on page 2 • Intensity: Low, Medium, High • Speed: Slow, Standard, Fast ◦ Slow Flash: 0.5 Hz ◦ Standard Flash: 1.0 Hz ◦ Fast Flash: 5.0 Hz ◦ Slow Rotate: 80 rpm ◦ Standard Rotate: 120 rpm ◦ Fast Rotate: 160 rpm - Audible Tones: Pulse, Wobble, Strobe, Whoop, Staccato, Siren, Continuous 1, Continuous 2, Jingle, Melody 1, Melody 2, Melody 3 Pro Converter Cable required to interface between PC and indicator, see accessories Default Indicator Characteristics At 12 V DC Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. |Supply<br>Wiring<br>(AWG)<br>20|Required Overcurrent<br>Protection (A)<br>5.0|Supply<br>Wiring<br>(AWG)<br>26|Required Overcurrent<br>Protection (A)<br>1.0| |---|---|---|---| |22|3.0|28|0.8| |24|2.0|30|0.5| Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN |Color|Dominant Wavelength<br>(nm) or Color|Color<br>Coordinates(3)|Color<br>Coordinates(3)|Lumen Output<br>(Typical at 25|Lumen Output<br>(Typical at 25| |---|---|---|---|---|---| |Green|Temperature (CCT)<br>528 nm|x<br>0.1603|y<br>0.6973|360|°C)| |Yellow|589 nm|0.5557|0.4276|525|| |Red|625 nm|0.6999|0.2982|155|| |Blue|475 nm|0.1167|0.1121|165|| |White|5500K ± 250|0.3320|0.3433|600|| Lumen Output decreases by 15% at 48 V DC Internal temperature compensation circuitry: Reduces the Lumen Output to decrease the unit internal operating temperature. The amount of reduction is dependent on the ambient operating temperature, supply voltage, color, and/or audible functions being utilized. (3) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. ## Photometric Data Multiply the values shown in the chart by the maximum candela values in the Max. Candela table: page 4 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 02-Sep-25 K100 Pro Daylight Visible Beacon (DC) ## Polar Candela Distribution **==> picture [148 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> 180°<br>1.2 170°160°150°<br>1 140°<br>0.8 130°<br>0.6 120°<br>0.4 110°<br>0.2 100°<br>0 90°<br>0.2 80°<br>0.4 70°<br>0.6 60°<br>0.8 50°<br>1 40°<br>1.2 Vertical Angle: 0° 10° 20° 30°<br>0° Vertical 90° Horizontal<br>**----- End of picture text -----**<br> ## Base Candela **==> picture [500 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> Green 46<br>Yellow 67<br>Red 20<br>Blue 21<br>White 76<br>**----- End of picture text -----**<br> ## Candela Viewing Angle Example – Red **==> picture [500 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Angle Factor Base [(4)] Candela<br>120 (top view) 0.7 20 14<br>90 (side view) 1 20 20<br>60 (bottom view) 0.7 20 14<br>**----- End of picture text -----**<br> ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [500 x 281] intentionally omitted <==** **----- Start of picture text -----**<br> Standard Models Audible Models<br>Ø 92.8 Ø 92.8<br>[3.65] [3.65]<br>80.9 81.0<br>[3.18] [3.19]<br>134.7 134.8<br>[5.3] [5.31]<br>25.5<br>25.5 M36 x 2.0 [1.01]<br>M36 x 2.0 [1.01]<br>Interior<br>Interior 3/4 - 14 NPT<br>3/4 - 14 NPT<br>13.0 M12 x 1.0 13.0<br>M12 x 1.0 [0.51] [0.51]<br>Ø 118.5<br>Ø 118.5 [4.67]<br>[4.67]<br>**----- End of picture text -----**<br> (4) Red shown. See Base Candela table. 02-Sep-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 8 K100 Pro Daylight Visible Beacon (DC) ## Accessories ## Pro Editor Hardware ## MQDC-506-USB - Pro Converter Cable - • 1.83 m (6 ft) length 5-pin M12 quick disconnect to Device and USB to PC • Required for connection to the configuration software **==> picture [91 x 38] intentionally omitted <==** ## CSB-M1251FM1251M - 5-pin parallel Y splitter (Male-Male-Female) - • For full Pro Editor preview capability • Requires external power supply, sold separately ## PSW-24-1 - 24 V DC, 1 A power supply - • 2 m (6.5 ft) PVC cable with M12 quick disconnect • Provides external power with splitter cable, sold separately ## ACC-PRO-CABLE5 - Mating accessory for cabled and terminal models - 150 mm (6 inch) PVC cable with M12 quick disconnect - • Lever wire nuts included (qty 5) - Required to connect cabled models and screw terminal models to Pro Converter Cable, sold separately x5 ## Cordsets **==> picture [500 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> 5-Pin Single-Ended M12 Female Cordsets<br>Model Length Style Dimensions Pinout (Female)<br>MQDC1-501.5 0.5 m (1.5 ft)<br>MQDC1-503 0.9 m (2.9 ft) 44 Typ.<br>MQDC1-506 2 m (6.5 ft)<br>MQDC1-515 5 m (16.4 ft) Straight<br>MQDC1-530 9 m (29.5 ft) M12 x 1 2<br>ø 14.5 1<br>MQDC1-560 18 m (59 ft)<br>3<br>MQDC1-5100 31 m (101.7 ft) 4 5<br>MQDC1-506RA 2 m (6.5 ft) 1 = Brown<br>32 Typ. 2 = White<br>MQDC1-515RA 5 m (16.4 ft) [1.26"] 3 = Blue 4 = Black<br>MQDC1-530RA 9 m (29.5 ft) 5 = Gray<br>30 Typ.<br>Right-Angle [1.18"]<br>MQDC1-560RA 19 m (62.3 ft)<br>M12 x 1<br>ø 14.5 [0.57"]<br>**----- End of picture text -----**<br> page 6 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 02-Sep-25 K100 Pro Daylight Visible Beacon (DC) ## Brackets ## LMB36RA - Indicator light right-angle mounting - • 36 mm mounting hole • Stainless steel **==> picture [87 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> 65 70<br>50.8<br>4 X Ø6.5 25.4<br>Ø36.5<br>62.5<br>**----- End of picture text -----**<br> ## Elevated Mount System Elevated Mount System (1/2" Pipes) **==> picture [500 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> Adapter/Cover Model Description<br>• Adapter from M36 thread to ½-14 NPSM thread<br>SA-M36E12 •• Streamlined black plastic mounting base adapter/coverDrilled hole<br>Black Anodized Aluminum, ½ in. NPT Pipe Clear Anodized Aluminum, ½ in. NPT Pipe<br>Models Models Description<br>Pipe<br>SOP-E12-150A , 150 mm (6 in) long SOP-E12-150AC , 150 mm (6 in) long<br>• Elevated-use stand-off pipe<br>SOP-E12-300A , 300 mm (12 in) long SOP-E12-300AC , 300 mm (12 in) long • Threaded at both ends<br>• Compatible with most industrial<br>SOP-E12-600A , 600 mm (24 in) long - environments<br>SOP-E12-900A , 900 mm (36 in) long SOP-E12-900AC , 900 mm (36 in) long<br>Mounting Base Model Description<br>• Elevated-use stand-off pipes (½ in, NPSM/DN15)<br>SA-F12 •• M5 mounting hardware and nitrile gasket includedDie-cast zinc base with black paint<br>**----- End of picture text -----**<br> ## Elevated Mount System (3/4" Pipes) **==> picture [500 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> Adapter/Cover Model Description<br>Adapter/<br>Cover • M36 thread adapter with clearance for ¾ pipe mount<br>SA-M36SOP •• Streamlined black plastic mounting base adapter/coverDrilled hole<br>Black Anodized Aluminum, ¾ in. NPT Pipe Models Description<br>Pipe<br>SOP-E34-150A , 150 mm (6 in) long<br>SOP-E34-300A , 300 mm (12 in) long •• Elevated-use stand-off pipeThreaded at both ends<br>SOP-E34-600A , 600 mm (24 in) long • Compatible with most industrial environments<br>SOP-E34-900A , 900 mm (36 in) long<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void 02-Sep-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 8 K100 Pro Daylight Visible Beacon (DC) the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 8 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 02-Sep-25
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →