K100PBLNGBR.
BEACON, BLU/GRN/RED, MULTIFUNCTION, 48V
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- Module Lens Colour:Blue, Green, Red; Supply Voltage VAC:-; Supply Voltage VDC:48V; Visual Signal Type:Multifunction; Lens Diameter:3.65"; Product Range:K100 Pr 77AK6009
- Power Rating: 12.5W
- Lens Diameter: 3.65"
- Product Range: K100 Pro Hazardous Beacon Series
- External Height: 5.3"
- IP / NEMA Rating: IP66, IP69K
- Module Lens Colour: Blue, Green, Red
- Supply Voltage VAC: -
- Supply Voltage VDC: 48V
- Visual Signal Type: Multifunction
- Operating Temperature Max: 60°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 440.63 € |
| Current stock | 10+ |
| Lead time | 30 days |
## K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet ## Features High Daylight Visibility, Programmable Multicolor Indicator with Optional Audible Alarm for Indoor or Outdoor Use **==> picture [59 x 84] intentionally omitted <==** - Highly visible indicator provides bright, even light in direct sunlight - • Ex/HazLoc approvals for potentially explosive environment applications • Three colors in one device • Programmable using Banner's Pro Editor software and Pro Converter Cable • 36 mm threaded polycarbonate base • Rugged IP69K per DIN 40050-9, UL Type 4X housing • PNP or NPN operation depending on wiring • Variety of connector options • Rugged UV-stabilized polycarbonate base and window • 12 V DC to 48 V DC operating voltage • IK10 Impact rating for maximum protection in demanding applications ## Pro Editor **==> picture [112 x 67] intentionally omitted <==** Use Banner's Pro Editor software and Pro Converter Cable to create custom configurations by selecting different colors, flash patterns, and animations. For more information visit www.bannerengineering.com/proeditor. ## Full Preview Connection (Required) The full preview connection must be used for the K100 Pro Hazardous Daylight Visible Beacon. **==> picture [500 x 219] intentionally omitted <==** **----- Start of picture text -----**<br> E<br>A = Pro Converter Cable (MQDC-506-USB)<br>A B = Splitter (CSB-M1251FM1251M)<br>C = PC running Pro Editor software<br>D = Any Banner Pro Series-enabled device (K50 shown)<br>E = Power Supply (PSW-24-1 or PSD-24-4)<br>C F = 8-Pin to 5-Pin Double-Ended Cordset (MQDC-801-5M-PRO), required<br>for 8-Pin models<br>D<br>B<br>F<br>**----- End of picture text -----**<br> ## Models Standard models shown. Contact factory for other options. Original Instructions June 09, 2023 © Banner Engineering Corp. p/n: 225024 Rev. B 225024 K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet **==> picture [460 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> Family Style Classification Color 1 * Color 2 Color 3 Audible Connector **<br>K100 P N G Y R A Q<br>G = Green R = Red Blank = None Blank = 2 m integral ITC-ER PVC cable<br>Q = 5-pin integral M12 male<br> quick disconnect ***<br> ** Models with a quick disconnect require a mating cordset<br>*** Must be enclosed with a protected conduit or a suitable enclosure<br>**----- End of picture text -----**<br> ## Installation Instructions ## Ex/HazLoc Applications **==> picture [32 x 192] intentionally omitted <==** - WARNING: • Explosive Atmospheres/Hazardous Locations • It is the user's responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relating to the installation and use of this device in any particular application are satisfied. This device must be installed by a Qualified Person[(1)] , in accordance with this document and applicable regulations. ## WARNING: - Explosion Hazard - • Do not disconnect equipment unless the power has been switched off or the area is known to be non-hazardous. ## CAUTION: - Electrostatic Discharge (ESD) Special Conditions for Safe Use - • Parts of the enclosure are non-conducting and can generate an ignition-capable level of ESD. • Clean the equipment with only a damp cloth. ## General Notes and Conditions for Use - See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations, electrical connections and certifications. - In addition to the warning above concerning user responsibility, the installation must comply with the following: - All installations must comply with all manufacturer's instructions. - All applicable wiring methods in accordance with the relevant local regulations and the authority having jurisdiction. - ◦ U.S. Installations: The relevant requirements of the National Electric Code® (ANSI/NFPA-70 NEC®). ◦ Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1). - • Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with non-factory components may adversely affect the safe use of the system. - The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges. - • Clean with a damp cloth only. - If the equipment is likely to come into contact with aggressive substances[(2)] , then it is the responsibility of the user to take suitable precautions[(3)] that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. - • The ingress protection (IP rating) of enclosures/panels may be invalidated by the installation of the beacon. The installation of the beacon in a particular enclosure/panel is subject to the evaluation/acceptance of the authority having jurisdiction. - • Models with integral quick-disconnect (QD) connectors: ◦ Use recommended Banner cordsets (see "Cordsets" on page 7), or suitable quick-disconnect cordsets with threaded retaining nut (see "Specifications" on page 3). The cordset must be securely fastened using the quick-disconnect retaining nut to prevent disconnection. Maximum connector torque: 6 ft-lbs. - Must be installed such that the connector is protected from impact and unauthorized disconnection. The method of protection can include conduit (e.g. pole, pendent), enclosed raceway, a listed enclosure suitable for the intended use, and/or by inaccessible location that excludes possible impact damage. - • The device must be powered by a Class 2 or SELV power supply. > (1) A Qualified Person is a person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work. > (2) Aggressive substances—for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. > (3) Suitable precaution—for example, regular checks as part of routine inspections or establishing from the materials data sheet that is resistant to specific chemicals. page 2 June 09, 2023 © Banner Engineering Corp. K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet ## Wiring Diagrams **==> picture [500 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> PNP Input NPN Input<br>3 3<br>12–48 V DC 12–48 V DC<br>4 4<br>1 1 Key<br>1 = Brown<br>2 1 2 1 2 = White<br>3 = Blue<br>2 2 4 = Black<br>3 3 5 = Gray<br>5 5<br>A A<br>**----- End of picture text -----**<br> ## An "X" denotes an active input. For example: When Input 1 and Input 3 are both active, the indicator will be Color 1 Flashing at 1 Hz. ## Default Configuration **==> picture [500 x 257] intentionally omitted <==** **----- Start of picture text -----**<br> Wiring Operating Mode/Function<br>Black Brown White Gray<br>(Input (Input (Input Non-Audible Audible<br>(Input 3)<br>1) 2) 4)<br> X Color 1 Steady Color 1 Steady<br> X Color 2 Steady Color 2 Steady<br> X Color 3 Steady Color 3 Steady<br> X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz<br> X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz<br> X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz<br> X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe<br> X Off Audible Steady, Frequency 2.5 KHz, Volume High<br> X X Color 1 Steady Color 1 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X Color 2 Steady Color 2 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X Color 3 Steady Color 3 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br> X X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe, Audible Steady, Frequency 2.5 KHz, Volume High<br>**----- End of picture text -----**<br> ## Specifications ## Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Indicator Response Time On response: 325 ms (max) Off response: 20 ms (max) ## Connections Integral 5-pin M12 male quick-disconnect connector or 2 m (6.5 ft) integral ITC-ER PVC-jacketed cable, depending on model Models with a quick disconnect require a mating cordset Connecting 5-pin M12 quick-disconnect cordsets (see "Cordsets" on page 7): Female single-ended Multiconductor cable (at minimum): UL Style 2517, 24 AWG wire, rated ≥ 80 °C; M12 quick-disconnect connector: per IEC 61076-2-101, must have threaded M12 x 1 retaining nut ## Operating Conditions –40 °C to +60 °C (–40 °F to +140 °F) 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) ## Environmental Rating IP66, IP69K per DIN 40050-9, UL Type 4X June 09, 2023 page 3 © Banner Engineering Corp. K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet ## LED Lifetime Lumen maintenance L70 When operating within specifications, output decreases less than 30% after 42,000 hours ## Mounting M36 by 2.0 threaded base, maximum torque 5.0 N·m (44 inch-lbf) Interior 3/4-14 NPT Thread Mounting nut included Adjacent Unit Mounting Separation Distance Minimum: 0 in (mounted with unit flanges touching) ## Audible Characteristics Sound Intensity at 2.5 KHz, at 1 m (typical): Low volume setting: 93 dB Medium volume setting: 96 dB High volume setting: 101 dB ## Construction Base, Dome, and Nut: Polycarbonate Approvals NEC and CEC (cULus) - Gas and Vapors: Class I Div 2 Groups ABCD T4 - • Dust and Fibers/flyings: Class II Div 2 Groups FG T6; Class III Div 1 and Div 2 T6 ## Pro Editor Configuration ## Connection to Pro Editor software enables control of: - Animation: On, Flash, Rotate, Two Color Flash, Two Color Cycle, Intensity Sweep - • Color: Green, Yellow, Red, Blue • Wiring: See "Wiring Diagrams" on page 3 • Intensity: Low, Medium, High • Speed: Slow, Standard, Fast Slow Flash: 0.5 Hz Standard Flash: 1.0 Hz Fast Flash: 5.0 Hz Slow Rotate: 80 rpm Standard Rotate: 120 rpm Fast Rotate: 160 rpm - Audible Tones: Pulse, Wobble, Strobe, Whoop, Staccato, Siren, Continuous 1, Continuous 2, Jingle, Melody 1, Melody 2, Melody 3 Pro Converter Cable required to interface between PC and indicator, see accessories ## Supply Voltage and Current ## 12 V DC to 48 V DC Product approved with usage of Class 1 or Class 3 Power Supply to achieve Class 2 Power Supply status Use only with a suitable Class 2 power supply (North America) **==> picture [222 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum Current (mA)<br>Steady On, Flash, or Strobe Rotate Function<br>Voltage Function [(1)]<br>Light & Audi-<br>Light Only Light & Audible Light Only ble<br> 12 760 820 365 435<br> 18 495 530 235 275<br> 24 395 425 185 220<br> 30 340 365 165 195<br> 36 305 330 150 180<br> 42 280 305 145 170<br> 48 260 285 140 165<br>**----- End of picture text -----**<br> ## Default Indicator Characteristics At 12 V DC **==> picture [222 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> Color Coordi-<br>Dominant Wavelength Lumen Output<br>Color (nm) or Color Tempera- nates [(2)] (Typical at 25<br>ture (CCT) x y °C)<br> Green 528 nm 0.1603 0.6973 360<br> Yellow 589 nm 0.5557 0.4276 525<br> Red 625 nm 0.6999 0.2982 155<br> Blue 475 nm 0.1167 0.1121 165<br>**----- End of picture text -----**<br> ## Lumen Output decreases by 15% at 48 V DC Internal temperature compensation circuitry: Reduces the Lumen Output to decrease the unit internal operating temperature. The amount of reduction is dependent on the ambient operating temperature, supply voltage, color, and/or audible functions being utilized. ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) Impact: IK10 (60068-2-75) ## Certifications E530817 Maximum Power Input Light Only: 12.5 W Light and Audible: 13.5 W > (1) Flash or Strobe Mode: Peak current, operating at 50% duty cycle or less. > (2) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. June 09, 2023 page 4 © Banner Engineering Corp. K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet ## Required Overcurrent Protection **==> picture [32 x 42] intentionally omitted <==** WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. **==> picture [222 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> ## Photometric Data Multiply the values shown in the chart by the maximum candela values in the Max. Candela table: Polar Candela Distribution **==> picture [148 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 180°<br>1.2 170°160°150°<br>1 140°<br>0.8 130°<br>0.6 120°<br>0.4<br>0.2 100°<br>0 90°<br>0.2 80°<br>0.4 70°<br>0.6 60°<br>0.8 50°<br>1 40°<br>1.2 0° 10° 20° 30°<br>90° Horizontal<br>**----- End of picture text -----**<br> ## Base Candela **==> picture [500 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Green 46<br>Yellow 67<br>Red 20<br>Blue 21<br>Candela Viewing Angle Example – Red<br>Angle Factor Base [(1)] Candela<br>120 (top view) 0.7 20 14<br>90 (side view) 1 20 20<br>60 (bottom view) 0.7 20 14<br>**----- End of picture text -----**<br> ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. > (1) Red shown. See Base Candela table. June 09, 2023 page 5 © Banner Engineering Corp. K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet **==> picture [500 x 282] intentionally omitted <==** **----- Start of picture text -----**<br> Standard Models Audible Models<br>Ø 92.8 Ø 92.8<br>[3.65] [3.65]<br>80.9 81.0<br>[3.18] [3.19]<br>134.7 134.8<br>[5.3] [5.31]<br>25.5<br>25.5 M36 x 2.0 [1.01]<br>M36 x 2.0 [1.01]<br>Interior<br>Interior<br>T<br>13.0 M12 x 1.0 13.0<br>M12 x 1.0 [0.51] [0.51]<br>Ø 118.5 [4.67]<br>[4.67]<br>**----- End of picture text -----**<br> ## Accessories ## Pro Editor Hardware - MQDC-506-USB • Pro Converter Cable • 1.83 m (6 ft) length 5-pin M12 quick disconnect to Device and USB to PC • Required for connection to Pro Editor **==> picture [91 x 38] intentionally omitted <==** ## CSB-M1251FM1251M - 5-pin parallel Y splitter (Male-Male-Female) - • For full Pro Editor preview capability • Requires external power supply, sold separately ## PSW-24-1 - 24 V DC, 1 A power supply - • 2 m (6.5 ft) PVC cable with M12 quick disconnect • Provides external power with splitter cable, sold separately ## ACC-PRO-CABLE5 - Mating accessory for cabled and terminal models - 150 mm (6 inch) PVC cable with M12 quick disconnect - • Lever wire nuts included (qty 5) • Required to connect cabled models and screw terminal models to Pro Converter Cable, sold separately **==> picture [10 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> x5<br>**----- End of picture text -----**<br> page 6 June 09, 2023 © Banner Engineering Corp. K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet ## Cordsets **==> picture [500 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> 5-Pin Threaded M12 Cordsets—Single Ended<br>Model Length Style Dimensions Pinout (Female)<br>MQDC1-501.5 0.5 m (1.5 ft)<br>MQDC1-503 0.9 m (2.9 ft)<br>MQDC1-506 2 m (6.5 ft)<br>MQDC1-515 5 m (16.4 ft) Straight<br>MQDC1-530 9 m (29.5 ft) M12 x 1<br>ø 14.5 2<br>MQDC1-560 18 m (59 ft) 1<br>MQDC1-5100 31 m (101.7 ft) 3<br>MQDC1-506RA 2 m (6.5 ft) 4 5<br>1 = Brown<br>MQDC1-515RA 5 m (16.4 ft) 2 = White<br>3 = Blue<br>MQDC1-530RA 9 m (29.5 ft) 4 = Black<br>5 = Gray<br>Right-Angle<br>MQDC1-560RA 19 m (62.3 ft)<br>M12 x 1<br>ø 14.5 [0.57"]<br>**----- End of picture text -----**<br> ## Brackets ## LMB36RA - Indicator light right-angle mounting - • 36 mm mounting hole • Stainless steel **==> picture [86 x 51] intentionally omitted <==** **----- Start of picture text -----**<br> 65 70<br>50.8<br>4 X Ø6.5 25.4<br>Ø36.5<br>62.5<br>**----- End of picture text -----**<br> ## Elevated Mount System Model Black Anodized AluClear Anodized AluBlack Anodized Aluminum minum minum ½ in. NPT ¾ in. NPT ½ in. NPT SOP-E34-150A 150 SOP-E12-150A 150 mm SOP-E12-150AC 150 mm (6 in) long (6 in) long mm (6 in) long - Black Anodized AluBlack Anodized Aluminum Clear Anodized AluFeatures Components minum minum ½ in. NPT - ¾ in. NPT ½ in. NPT - SOP-E34-150A 150 SOP-E12-150A 150 mm SOP-E12-150AC 150 - mm (6 in) long (6 in) long mm (6 in) long • Elevated-use stand-off pipe - SOP-E34-300A 300 SOP-E12-300A 300 mm SOP-E12-300AC 300 • Black anodized aluminum or clear an- - mm (12 in) long (12 in) long mm (12 in) long odized aluminum surface • Threaded at both ends - mm (24 in) long SOP-E34-600A 600 (24 in) long SOP-E12-600A 600 mm — • Compatible with most industrial environ-ments SOP-E34-900A 900 SOP-E12-900A 900 mm SOP-E12-900AC 900 - mm (36 in) long (36 in) long mm (36 in) long • Adapter from M36 thread to 12-14 NPSM thread - SA-M36E12 • Streamlined black plastic mounting base adapter/cover - • Drilled hole • M36 thread adapter with clearance for ¾ pipe mount - SA-M36SOP • Streamlined black plastic mounting base adapter/cover - • Drilled hole June 09, 2023 page 7 © Banner Engineering Corp. K100 Pro Hazardous Daylight Visible Beacon - DC Datasheet **==> picture [500 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> Pipe Mounting Flange<br>Model Features Construction<br>• Elevated-use stand-off pipes (½ in, NPSM/ 4x ø5.5 54<br>DN15) Die-cast zinc base with black<br>SA-F12 • M5 mounting hardware and nitrile gasket paint ø28<br>included 10 ø70<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 8 June 09, 2023 © Banner Engineering Corp.
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →