Image not available
Illustrative purposes only
JAC-30-683
Power Line Filter, General Purpose, 500 V, 30 A, Three Phase, 1 Stage, Chassis Mount
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- No. of Phases: Three Phase
- No. of Stages: 1 Stage
- Product Range: JAC Series
- Current Rating: 30A
- Voltage Rating: 500V
- Filter Mounting: Chassis Mount
- Filter Applications: General Purpose
- Filter Input Terminals: Screw
- Filter Output Terminals: Screw
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 31.54 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [417 x 210] intentionally omitted <==** **----- Start of picture text -----**<br> Three phase input type(1-stage filter) Ordering information<br> JAC -30 -683 - O<br>| JAC series(6-30A) — 1 2 3 4<br>1 Model Name<br>R 2 Rated Current<br>3<br>Adis CS Ke “sie<br>RoHS a<br>Code<br>103<br>223<br>683<br>*<br>different.<br>*<br>system).<br>The terminal cover is retracted inside the unit DIN rail installation type is option 4 Option<br>**----- End of picture text -----**<br> **==> picture [238 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3 4<br>1 Model Name<br>2 Rated Current<br>3 Line to ground capacitor code:See table 1.1.<br>table1.1 Line to ground capacitor code<br>Line to ground<br>Code Leakage Current capacitor<br>(Input 250/500V 60Hz)<br>(nominal value)<br>103 0.5mA/1.0 mA max 10,000pF<br>223 1.0mA/2.0 mA max 22,000pF<br>683 2.5mA/5.0 mA max 68,000pF<br>* When the line to ground capacitor code is<br>different, the attenuation characteristic is<br>different.<br>**----- End of picture text -----**<br> - **Please contact us about ultra high attenuation type for EU (Wye type with neutral earth system).** - 4 **Option D:DIN rail installation type** * **The dimensions change when the option is set. Refer to External view.** - **H:Ultra high-attenuation type** **Features of JAC series** ~~ee~~ **Compact and low profile , common mode EMI/EMC filters in 150kHz to 1MHz(1stage filter)** - **Three Phase 500 VAC** - **Push down type terminal block** ## **Specifications** |**No.**|**Items**<br>~~a~~|**JAC-06-683**|**JAC-10-683**|**JAC-20-683**|**JAC-30-683**| |---|---|---|---|---|---| |**1**|**Rated Voltage[V]**<br>~~PO~~|AC Three Phase 500(voltage range:528 max)50/60Hz|||| |**2**|**Rated Current[A]**<br>~~eG~~|6<br>~~eG~~|10<br>~~eG~~|20<br>~~eG~~|30| |**3**|**Test Voltage (Terminal-Mounting Plate)**<br>~~eG~~<br>~~PO~~|2,500 VAC(Cutoff Current = 100mA),1minute at room temperature and humidity<br>~~eG~~|||| |**4**|**Isolation Resistance(Terminal-Mounting Plate)**<br>~~PO~~|500 VDC 100MWmin at room temperature and humidity|||| |**5**|**Leakage current 250/500V 60Hz**<br>~~PO~~|2.5mA/5.0mA max|||| |**6**|**DC registance**<br>~~PO~~<br>~~Ge~~|100mWmax<br>~~Ge~~|45mWmax<br>~~Ge~~|15mWmax<br>~~Ge~~|8mWmax| |**7**|**Safety agency approval temperatures**<br>~~PO~~|-25 to +85C (Refer to DeratingCurve)|||| |**8**|**Operating temperature**<br>~~PO~~|-40 to +85C (Refer to DeratingCurve)|||| |**9**|**Operating humidity**<br>~~PO~~<br>~~PO~~|20 to 95%RH(Non condensing)|||| |**10**|**Storage temperature/humidity**<br>~~PT~~|-40 to +85C/20 to 95%RH(Non condensing)|||| |**11**|**Vibration**<br>~~PO~~|10 to 55Hz,19.6m/s2(2G),3min. Period,1hour each X,Y and Z axis|||| |**12**|**Impact**<br>~~PO~~<br>~~PO~~|196.1m/s2(20G),11ms Once each X,Y and Z axis|||| |**13**<br>~~|~~|**Safety agency approvals**<br>~~PT~~<br>~~|~~|UL1283,CSA C22.2 No.8(C-UL) ,DIN EN60939 VDE0565 Teil3-1,ENEC|||| |**14**<br>~~|~~|**Case size (without projection)**<br>~~|~~<br>t—“‘i‘sdzCY|63X44X132 mm(WXHXD) (Option: -D refer to external view)|||| |||[2.48X1.73X5.20 inches] (WXHXD)|||| |**15**<br>~~|~~|**Weight**<br>~~|~~<br>~~PT~~|440gmax|||| **==> picture [505 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> i Circuit Diagram 36 Derating Curve<br>100<br>LINE Case LOAD<br>80<br>1 Be 4 70 i<br>2 5 CX : Line to line 60 pocfetestetey |<br>3 6 capacitor<br>CY : Line to ground 40<br>CX CX CX CX CX CX capacitor<br>: Lif CYCY io. : Mounting Plate 2010 P| | | | tt Xd<br>0<br>-40 -30 -20 40 50 60 70 80 90<br>Ambient Temperature [ ]<br>Load Factor [%]<br>**----- End of picture text -----**<br> **NF-54** ## **JAC series(6-30A)** ## **External view** **As this product is adopted push-down type terminal block, this appearance is as follows.** 1 **The terminal cover is retracted inside the unit.** 2 **The screws for connecting the terminals are held in the up right position.** ## **Standard Type** **==> picture [488 x 602] intentionally omitted <==** **----- Start of picture text -----**<br> 132<br>[5.20] Terminal Cover<br>119 (Terminal Block screw pitch)<br>2-f5.5 [0.22] [4.69] 2.5 32<br>Mounting Hole [0.10] [1.26]<br>3-M4<br>Output<br>3-M4 Name Plate Terminal<br>Input<br>Terminal<br>Mounting Plate M4<br>Protection Earth<br>118 (Mounting Hole pitch)<br>Terminal cover [4.61]<br>¶ Close the terminal cover<br>¶ Tolerance : ±1[±0.04]<br>¶ Weight : 440g max<br>¶ Mounting Plate : Iron(surface finishing : nickel plating) t=1.0[0.04]<br>¶ Case : PBT<br>¶ Dimensions in mm, [ ]=inches<br>¶ Terminal block screw tighting torque M4 : 1.6N-m(16.9kgf-cm)max<br>4.5<br>[0.18] 4.5<br>[0.18]<br>DIN rail installation Type<br>132 9 ±2<br>[5.20] [0.35] Terminal Cover<br>119 (Terminal Block screw pitch)<br>[4.69] 2.5 32<br>[0.10] [1.26]<br>3-M4<br>3-M4 Output<br>Input Name Plate Terminal<br>Terminal<br>Mounting Plate M4<br>Protection Earth<br>Terminal cover<br>¶ Close the terminal cover<br>¶ Tolerance : ±1[±0.04]<br>¶ Weight : 440g max<br>¶ Mounting Plate : Iron(surface finishing : nickel plating) t=1.0[0.04]<br>¶ Case : PBT<br>¶ Dimensions in mm, [ ]=inches<br>¶ Terminal block screw tighting torque M4 : 1.6N-m(16.9kgf-cm)max<br>4.5 DIN rail 4.5<br>[0.18]<br>[0.18]<br>Note when installing the EMI/<br>EMC Filter on a DIN rail. DIN rail<br>When the EMI/EMC Filter is grounded through Name Plate<br>the DIN rail, the proper noise attenuation may not<br>Be sure to connect the protection earth (PE) of<br>the EMI/EMC Filter body to the earth.<br>9.7 [0.38] 50 [1.97] 63 [2.48]<br>13.3 [0.52]<br>2 [0.08]<br>44 [1.73]<br>8 [0.31]<br>9.7 [0.38] 63 [2.48]<br>13.3 [0.52]<br>2<br>[0.08]<br>44 [1.73]<br>8 [0.31]<br>(9) 7 [0.28]<br>**----- End of picture text -----**<br> **==> picture [194 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> DIN rail<br>Name Plate<br>**----- End of picture text -----**<br> ## ¡ **Note when installing the EMI/ EMC Filter on a DIN rail.** **When the EMI/EMC Filter is grounded through the DIN rail, the proper noise attenuation may not be achieved.** **Be sure to connect the protection earth (PE) of the EMI/EMC Filter body to the earth.** **NF-55**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →