Image not available
Illustrative purposes only
IUGN62-34230-1
MAGNETIC HYDRAULIC CIRCUIT BREAKERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA / PARTNER STOCK
- Product type: Magnetic Hydraulic Circuit Breakers
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 402.23 € |
| Current stock | 10+ |
| Lead time | 15 days |
## **IAG/IUG/IEG/CEG/LEG Series** Magnetic Circuit Protectors |_Introduction_|**•**|**_99_**| |---|---|---| |_Poles_|**•**|**_100_**| |_Handles_|**•**|**_103_**| |_Configurations_|**•**|**_108_**| |_Operating Characteristics_|**•**|**_110_**| |_Delay Curves_|**•**|**_111_**| |_Specifications_|**•**|**_115_**| |_Decision Tables_|**•**|**_117_**| ## PAX: | **IAG/IUG/IEG/CEG/LEG Series** Hydraulic Magnetic Circuit Protectors ## **INTRODUCTION** The Airpax™ IAG/IUG/IEG/CEG/LEG magnetic circuit protectors provide low-cost power switching, reliable circuit protection and accurate circuit control for equipment in the international marketplace. equipment, vending and amusement machines, military applications and wherever precision operation is required. Temperature differences which affect fuses and other thermal devices are not a concern. IEG models meet IEC spacing requirements which is mandatory for equipment that must comply with IEC specifications 601 and 950 and VDE specifications 0804 and 0805. In addition, they are UL Recognized as supplementary protectors per UL STD. 1077, CSA Certified as supplementary protectors per CSA C22.2–No. 235, VDE Approved to VDE 0642 (EN60934), CCC Approved and CE Compliant. IAG models are for those applications where the unit’s inherent attributes are desired, but compliance with the various standards is not required. Designed using the latest in sensitive hydraulic magnetic technology, the IAG/IUG/IEG/CEG/LEG line adapts itself to many applications and environments. They’re ideal for data processing and business machines, medical instrumentation, broadcast One important feature of this protector line is a “trip free” action, which means the circuit will trip in the presence of an overload even though the handle is held in the ON position. The delay mechanism senses the fault and the contacts open. The IAG/IUG/IEG/CEG/LEG is available in a wide variety of configurations including series, series with auxiliary switch, shunt and relay with a choice of delays and ratings in either DC, 50/60Hz or 400Hz versions. Handles come in seven different colors and international markings are standard. Single or multipole versions are available, with a variety of pole arrangements to meet your specifications. Four pole models require a double toggle handle. Units with a handle per pole come in one through six pole assemblies. _IAG Series - Introduction_ http://airpax.sensata.com **99** ## **SINGLE POLE CIRCUIT PROTECTOR** ## **Single Pole Mounting Detail** **==> picture [164 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> .590<br>[15.00] 2X 6 – 32 THREAD<br>MAX. .140 [3.56] DEEP<br>M3 ISO THD. OPTIONAL<br>2.000 ON OFF .1.660<br>[50.80] re _| [42.16]<br>1.220<br>[31.00]<br>| | Wi<br>a .750 ook EL .168<br>[19.05] [4.27]<br>**----- End of picture text -----**<br> **==> picture [57 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> +.010<br>-.000<br>.625<br>+.25<br>-.00<br>15.88<br>1.660<br>[42.16] 1.050<br>[26.67]<br> 2X 0.156 o +<br> [3.96]<br>**----- End of picture text -----**<br> **==> picture [136 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> .230<br>[5.84]<br>,<br>1.530<br>[38.86]<br>T |<br>Note: Tolerance ±.015 [.38] unless noted.<br>Dimensions in brackets [ ] are millimeters.<br>LEG Type Units Require Screw Terminals<br>**----- End of picture text -----**<br> _IAG Series - Poles_ **100** **==> picture [612 x 61] intentionally omitted <==** ## **MULTI-POLE CIRCUIT PROTECTORS (IAG/IUG/IEG/CEG/LEG)** ## **Two Pole Protectors** An assembly consisting of two single pole units, having their trip mechanisms internally coupled and with a single toggle handle, forms the IEG11 with quick-connect D.I.N.-style terminals. Individual poles may differ in ratings, delays and internal connections. An auxiliary switch may be included in either or both poles, allowing you to mix SELV and hazardous voltages. Rugged screw-type terminals can be provided, in which case the designation would be IEG66. The IEGH offers a toggle handle for each pole. LEG type units are avavailable only in one or two pole configurations. ## **Three Pole and Four Pole Protectors** The three pole construction consists of three single pole units assembled with an internal mechanical interlock which actuates all units simultaneously. A single toggle handle operates all three poles for quick and convenient control, or if preferred, a handle per pole is available. The four pole construction consists of four single pole units assembled with an internal mechanical interlock which actuates all units simultaneously. A double toggle handle operates all four poles. The individual poles need not have identical characteristics and any series trip pole may have an auxiliary switch. If screw-type terminals are required, the breaker designation will be IEG666 for a three pole version and IEG6666 for a four pole version. Protector poles are numbered consecutively when viewed from the terminal side, with the ON position up, starting with Pole #1 on the left side and proceeding to the right. **==> picture [203 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> IAG/IUG/IEG/CEG/LEG Multi-Pole Circuit Breakers<br>**----- End of picture text -----**<br> **==> picture [526 x 328] intentionally omitted <==** **----- Start of picture text -----**<br> IAG/IUG/IEG/CEG/LEG<br>1.687 .240 Two Pole* Three Pole* Four Pole*<br>[42.85] [6.10]<br>ON<br>32º<br>ON OFF ON OFF ON OFF ON OFF<br>32º<br>OFF<br>2.075 .690 1.51 5 2.265 3.015<br>[52.71] [17.53] [38.48] [57.53] [76.58]<br>MAX. MAX. MAX. MAX.<br>(Optional: Handle may be<br>located in Pole 1 instead<br>of Pole 2)<br>LEG Type Units Require<br>Screw Terminals<br>.230 Two Pole* Three Pole* Four Pole*<br>[5.84]<br>2X .625+.010 -.000<br>[15.88+.25 -.00<br>1.530<br>[38.86] 1.660<br>[42.17] 1.050<br>[26.68]<br>4X .156 .750 . 7 5 0 . 7 5 0 . 7 5 0 . 7 5 0 . 7 5 0<br> [3.96] [19.05] [19.05] [19.05] [19.05] [19.05] [19.05]<br>[<br>**----- End of picture text -----**<br> Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] unless noted. *See Single Pole Mounting Detail for hole sizes and locations. LEG type units are only available in one or two poles. Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. _IAG Series - Poles_ http://airpax.sensata.com **101** ## **MULTI-POLE CIRCUIT PROTECTORS (IAGH/IUGH/IEGH/CEGH/LEGH)** The IAGH/IUGH/IEGH/CEGH/LEGH two, three and four pole models are available with a handle per pole. LEGH type units are available only in two pole models. **==> picture [582 x 313] intentionally omitted <==** **----- Start of picture text -----**<br> IAGH/IUGH/IEGH/CEGH/LEGH Protectors 4X 6 – 32 THREAD<br>2X .590 .140 [3.56] DEEP<br>1.687 .240 [15.00] M3 ISO THD. OPTIONAL<br>[42.85] [6.10] MAX.<br>ON<br>32º<br>2.000 1.660 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF<br>32º [50.80] [42.16]<br>1.220<br>OFF<br>[31.00]<br>2.075 .690 .168 1.515 2.265 3.015<br>[52.70] [17.53] [4.27] [38.48] [57.53] [76.58]<br>MAX. MAX. MAX. MAX.<br>LEG (Requires Screw Terminals) Two Pole Three Pole* Four Pole*<br>.230 +.010<br>[5.84] 2X .625-.000<br>+.25<br>-.00<br>15.87<br>1.660<br>1.530 [42.16]<br>[38.86] 1.050<br>[26.67]<br>. 7 5 0 . 7 5 0 . 7 5 0<br> 4X .156 . 75 0 . 75 0 . 75 0 [19.05] [19.05] [19.05]<br> [3.96] [19.05] [19.05] [19.05]<br>**----- End of picture text -----**<br> *S ~~ee~~ T ~~w~~ o ~~Pol~~ e Mounting Detail for hole sizes and locations. ## **LEG/LEGH Barriers (required)** In order to meet UL listing requirements, the LEG/LEGH two pole model requires barriers. Available with a standard straight barrier or an optional “Z” type barrier. Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] unless noted. NOTE: We recommend machining slots into your panel for 2 or more poles. This eliminates the need to dissemble/reassemble the handle ties to be able to insert the handles thru indvidiually drilled holes. LEG type units are only available in one or two poles. ## **Standard Barrier** **==> picture [76 x 108] intentionally omitted <==** **==> picture [60 x 101] intentionally omitted <==** ## **Optional “Z” Barrier** **==> picture [74 x 87] intentionally omitted <==** **==> picture [124 x 126] intentionally omitted <==** **==> picture [238 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters.<br>**----- End of picture text -----**<br> _IAG Series - Poles_ **102** **==> picture [612 x 61] intentionally omitted <==** ## **ROCKER CIRCUIT PROTECTORS (IAGX/IAGZX/IUGX/IUGZX/IEGX/IEGZX/CEGX/CEGZX/LEGZX)** The IAGX/IUGX/IEGX/CEGX and IAGZX/IUGZX/IEGZX/CEGZX/ LEGZX styles offer two attractive rocker actuator versions of our popular IAG/IUG/IEG/CEG/LEG family. Designed with the operator in mind, each features handles with a concave surface and aesthetic appearance for front panel applications. The IAGZX/IUGZX/IEGZX/CEGZX/LEGZX style adds our “EZ” options of contrasting dual color rocker actuators, affording a clear visual indication of the handle position and integrated handle guards, to help prevent accidental turn-on and turn-off of the unit. Available with a black rocker and white, red or green indicator color for either ON or OFF indication. Both are available with rocker handle styles in a choice of five single colors: black, red, grey, orange or white. **==> picture [522 x 244] intentionally omitted <==** **----- Start of picture text -----**<br> IAGX/IUGX/IEGX/CEGX<br> Single Pole Two Pole Three Pole Four Pole<br>6 – 32 THD. (TYP.)<br>M3 ISO THD.<br>OPTIONAL 1.515 2.265 3.015<br>1.68[42.85] 7 .750[19.05] MAX.[38.48] [57.53]MAX. [76.58]MAX.<br>(Optional: Handle may be<br>2.206 located in Pole 2 instead<br>1.220[30.99] [56.03] of Pole 1)<br>2.000[50.80] 1.972 ON 1.660 ON ON ON ON<br>[50.09] [42.16]<br>OFF OFF OFF OFF OFF<br>2.470 .490 ±.005<br>[62.74] [12.45] .735<br>MAX. MAX. [±.13]<br>[18.67] Mounting Detail<br>(HANDLE WIDTH) Single, Two & Three Pole Four Pole*<br>2X .156 1.510<br>[3.96] [38.35]<br>Panel Mounting Detail: Tolerance for<br>1.260 1.660[42.16] mounting ±.005 [.13] unless noted.*See Single Pole Mounting Detail for<br>.200 [32.00] hole sizes and locations.<br>[5.08]<br>.750 .750<br>[19.05] [19.05]<br>**----- End of picture text -----**<br> **==> picture [141 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> IAGZX/IUGZX/IEGZX/CEGZX/LEGZX<br>**----- End of picture text -----**<br> **==> picture [508 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> Single Pole* Two Pole* Three Pole Single, Two & Three Pole<br>2.470 MA[62.74] X. .420 REF.[10.67] [19.05].750 6 – 32 THD. (TYP.) [38.48]1.515 2.265 Max.[57.53] 2X .156[3.96]<br>1 .68 7 .125 M3 ISO THD.<br>[42.85] [3.18] OPTIONAL 1.660<br>[42.16]<br>1.220 1.260<br>2.000 [30.99] .200 [32.00]<br>[50.80] [5.08]<br>1.530[38.86] 2.165[54.98] ON 1.660[42.16] ON ON<br>OPTIONALHANDLE GUARDS OFF OFF OFF .750[19.05]<br>(SEE DETAIL “A”)<br>.430 1.239[31.47] Panel Mounting Detail: Tolerance for<br>[10.92] Mtg. ±.005 [.13] unless noted.<br>**----- End of picture text -----**<br> Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. * LEG type units are only available in one or two poles. **==> picture [53 x 54] intentionally omitted <==** Detail “A” _IAG Series - Handles_ http://airpax.sensata.com **103** ## **ROCKER CIRCUIT PROTECTORS (IAGBX/IUGBX/IEGBX/CEGBX/LEGBX)** The innovative new design of our IEG BX style circuit breaker features a flat front rocker that not only satisfies your aesthetic needs, it guards against accidental actuation while providing the highest degree of circuit protection and quality. Only Sensata Technologies offers this new standard in user interface, providing additional peace of mind that guards alone can’t supply. Available on a variety of versions with a full range of agency approvals, the new IEG BX style circuit breakers meet or exceed all current performance specifications, including interrupting capacities up to 50,000 amperes. Various guard options offer additional and increasing levels of actuation protection performance. The two shot mold on the flat rocker surface provides a clean, crisp legend that can withstand demanding use. ## **IAGBX/IUGBX/IEGBX/CEGBX/LEGBX** **==> picture [252 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> 2.378 MAX .387 REF.<br>[60.40] [9.84]<br>.125<br>1.687 [3.18]<br>[42.85]<br>2.000<br>[50.80] 1.220<br>[30.99]<br>1.530<br>[38.86]<br>1.239<br>.314 [31.47]<br>[7.98]<br>SINGLE POLE<br>2X ø .156<br>.750 [3.96]<br>[19.05]<br>1.660 1.260<br>[42.16] [32.00]<br>ON<br>I<br>2.217 1.660<br>[56.31] [42.16]<br>O<br>OFF .200 .750<br>[5.08] [19.05]<br>OPTIONAL Panel Mounting Detail<br>GUARD<br>(SEE DETAIL “A”)<br>MOUNTING DETAIL TOLERANCE:<br>6-32 THD. MOUNTING ±.005 [.13] UNLESS NOTED<br>M3 ISO THD. OPTIONAL<br>**----- End of picture text -----**<br> **==> picture [202 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> Handle position Handle<br>"OFF" with guard position "ON"<br>(6th decision, G) with guard<br>(6th decision, G)<br>Actuation<br>access handle<br>(see note)<br>O O<br>ON<br>ON I<br>I<br>OFF OFF<br>**----- End of picture text -----**<br> **==> picture [205 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> Handle position Handle position<br>"OFF" guard with "ON" guard with<br>no actuate “OFF” no actuate “OFF”<br>feature feature<br>(6th decision, X) (6th decision, X)<br>ON<br>ON I<br>I<br>PUSH PUSH<br>TO TO<br>RESET RESET<br>**----- End of picture text -----**<br> **==> picture [203 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> Handle position Handle position<br>"OFF" without "ON" without<br>guard guard<br>DETAIL "A"<br>O O<br>ON<br>ON I<br>I<br>OFF<br>OFF<br>**----- End of picture text -----**<br> Note: Access is limited to a device smaller than the Underwriters Laborator “articulated probe” Defined in UL-489 FIG. 11.1.7.2.1. _IAG Series - Handles_ **104** **==> picture [612 x 61] intentionally omitted <==** ## **SEALED TOGGLE CIRCUIT PROTECTORS (IAGN/IUGN)** The IAGN/IUGN family is a sealed toggle version of the IAG/IUG family. The silicone rubber seal around the handle assures panel seal integrity and makes this style a natural for harsh environments. This sealed toggle family is available in one to three poles with ratings of .050 to 50 amperes. **==> picture [503 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> Single Pole Two Pole Three Pole<br>KEYWAY<br>.060 [1.52] – .065 [1.65] WIDE<br>.030 [.76] – .035 [.89] DEEP 1.515 2.265<br>.750 [38.48] [57.53]<br>.130 6 – 32 MTG. SCREW [19.05] MAX. MAX.<br>[3.30] FOR HIGH SHOCK<br>MTG.<br>LOCKWASHER ±3º 1.220<br>13º [30.99]<br>ON<br>2.000<br>[50.80]<br>.656<br>OFF ±3º [16.66]<br>13º<br> 1/2 – 32 HEX NUT<br>2.256 (Optional: Handle may be<br>[57.30] RUBBER “O” RING located in Pole 2 instead<br>MAX. .625 .750 of Pole 1)<br>[15.88] [19.05]<br>Mounting Detail<br>Optional Handle Single Pole Two Pole* Three Pole*<br> .156 .750 .750 . 750<br>[3.96] [19.05] [19.05] [19.05]<br>.656<br>[16.66]<br> .515<br>[13.08]<br>**----- End of picture text -----**<br> Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] unless noted. *See Single Pole Mounting Detail for hole sizes and locations. Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. _IAG Series - Handles_ http://airpax.sensata.com **105** ## **SNAP-IN CIRCUIT PROTECTORS (IEGS/IEGHS/CEGS/CEGHS/LEGS/LEGHS)** The Snap-In version of the IEG brings mounting simplification and international spacing together in a package that is aesthetically enhanced. The IEGS securely snaps into a rectangular cut-out, eliminating the need for panel mounting hardware and the associated costs. The face plate of the IEGS is a clean, black matte and it satisfies the increasing demand for front panel components that are designed with ergonomic considerations. The IEGS is offered in either flush or beveled versions, in 1, 2, 3 or 4 pole packages, and with a handle per pole or per unit. The IEGS is UL Recognized, CSA Certified and VDE approved. **==> picture [577 x 310] intentionally omitted <==** **----- Start of picture text -----**<br> IEGHS/CEGHS/LEGHS Circuit Protectors (Note B)<br>(Multi-Pole-IEGH Handles Per Pole)<br>(Omit H for Single Pole)<br>1.687 .240 .744 1.488 2.232 2.976<br>[42.85] [6.09] [18.90] [37.80] [56.69] [75.59]<br>ON<br>ON ON ON ON ON ON ON ON ON ON<br>32º<br>2.000<br>[50.80] 32º 2.598<br>[30.99]1.220 OFF [65.99]<br>OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF<br>2.075 .690<br>[52.70] [17.53]<br>MAX.<br>DIM. “B”<br>(SEE TABLE)<br>Note:<br>Panel Cutout Detail A: Flush face plate is optional. See decision tables, sixth decision.<br>Panel Thickness: (See Table) B: Tolerance ± .031 [.79] Angles: ±5° unless noted. Dimensions in<br>brackets [ ] are millimeters.<br>DIM. “C”<br>(SEE TABLE)<br>DIM. “A”<br>(SEE TABLE) .127<br>[3.23]<br>**----- End of picture text -----**<br> **==> picture [542 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> DIMENSIONS “A”, “B”, “C”<br>Number of Poles Dimension “A”, inches [ mm ] Dimension “B”, inches [ mm ] Dimension “C”, inches [ mm ]<br>1 pole .750 [19.05] max .755 [19.18] min<br>2 pole 1.515 [38.48] max 1.520 [38.61] min 2.180 ± .005 2.186 ± .011<br>3 pole 2.265 [57.53] max 2.270 [57.66] min [55.37 ± .13] [55.52 ± .28]<br>4 pole 3.015 [76.58] max 3.020 [76.71] min<br>.040 to .059 .060 to .100<br>Panel Thickness<br>[1.02 to 1.50] [1.52 to 2.54]<br>**----- End of picture text -----**<br> _IAG Series - Handles_ **106** **==> picture [612 x 61] intentionally omitted <==** ## **IEGS/CEGS/LEGS Circuit Protectors** (Note B) (Add H for multiple handles per unit, IEGHS) **==> picture [484 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> 1.687 .240<br>[42.85] [6.09] .960 1.700 2.450 3.190<br>[24.38] [43.18] [62.23] [81.03]<br>ON ON ON ON ON ON<br>32º<br>2.000<br>[50.80] 2.598<br>32º<br>1.220 [65.99]<br>[30.99] OFF<br>OFF OFF OFF OFF OFF<br>2.075 .690<br>[52.70] [17.53]<br>MAX.<br>**----- End of picture text -----**<br> **==> picture [484 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> Panel Cutout Detail DIM. “B”<br>Panel Thickness: (See Table) (SEE TABLE)<br>DIM. “C”<br>(SEE TABLE)<br>DIM. “A”<br>(SEE TABLE) .130<br>[3.30]<br>**----- End of picture text -----**<br> **==> picture [542 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> DIMENSIONS “A”, “B”, “C”<br>Number of Poles Dimension “A”, inches [ mm ] Dimension “B”, inches [ mm ] Dimension “C”, inches [ mm ]<br>1 pole .750 [19.05] max .780 ± .015 [19.81 ± .381]<br>2 pole 1.515 [38.48] max 1.540 ± .015 [39.12 ± .381] 2.180 ± .005 2.186 ± .011<br>3 pole 2.265 [57.53] max 2.290 ± .015 [58.17 ± .381] [55.37 ± .13] [55.52 ± .28]<br>4 pole 3.015 [76.58] max 3.040 ± .015 [77.22 ± .381]<br>.040 to .059 .060 to .100<br>Panel Thickness<br>[1.02 to 1.50] [1.52 to 2.54]<br>**----- End of picture text -----**<br> ## Optional Handle Guard **==> picture [59 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> .780<br>[19.82]<br>1.560<br>[39.62]<br>.734<br>[18.64]<br>**----- End of picture text -----**<br> **==> picture [41 x 97] intentionally omitted <==** **==> picture [64 x 102] intentionally omitted <==** Note: A: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. B: Bevelled face plate is standard. _IAG Series - Handles_ http://airpax.sensata.com **107** **==> picture [612 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> CONFIGURATIONS .230[5.84] .[5.84]230<br>Series Trip<br>The most popular configuration for magnetic protectors is<br>the series trip where the sensing coil and contacts are in [38.86]1.530 Series [38.86]1.530 Switch<br>series with the load being protected. The handle position Only<br>conveniently indicates circuit status. In addition to<br>providing conventional overcurrent protection, it’s<br>simultaneously used as an on-off switch.<br>Shunt Trip<br>The shunt trip is designed for controlling two separate loads<br>with one assembly. The control is established by providing Optional flat<br>overload protection for the critical load. When the current screw terminal .230 2.52 MAX.[64.00]<br>through this load becomes excessive and reaches the trip [5.84] (See Note A)<br>point, the protector will open and remove power from both<br>loads simultaneously. The total current rating of both loads 1.380<br>[35.05]<br>must not exceed the maximum contact rating.<br>1.530 Shunt<br>Auxiliary Switch (Applies to Series Trip Only) [38.86]<br>This is furnished as an integral part of a series pole in<br>single or multi-pole assemblies. Isolated electrically from<br>IAG Series<br>**----- End of picture text -----**<br> This is furnished as an integral part of a series pole in single or multi-pole assemblies. Isolated electrically from the protector’s circuit, the switch works in unison with the power contacts and provides indication at a remote location of the protector’s on-off status. Auxiliary switch contacts actuate simultaneously with the main protector contacts, and will open regardless of whether the protector contacts are opened manually or electrically. For auxiliary switch ratings below 6Vac or 5Vdc, an auxiliary switch with gold contacts designated as REG is available. Gold contacts are not recommended for load current above 100 milliamps. **==> picture [237 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> Standard Auxiliary Switch VDE Auxiliary Switch<br>.441 .469<br>[11.20] [11.91]<br>1.083[27.51] .848 1.059[26.90].764<br>[21.53] [19.04]<br>2.438 MAX. 2.454 MAX.<br>.110[2.79] [61.93](See Note A) .187[4.75] (See Note A)[62.33]<br>.260 .250<br>–IREC4 [6.60] [6.35]<br>–IREG4 –IREC5<br>**----- End of picture text -----**<br> |**MAIN TERMINAL TYPES**|**MAIN TERMINAL TYPES**|**MAIN TERMINAL TYPES**|**MAIN TERMINAL TYPES**|**MAIN TERMINAL TYPES**|**MAIN TERMINAL TYPES**| |---|---|---|---|---|---| |**Amp**<br>**Rating**|**Push-On**|**8-32**<br>**Screw**|**M4**<br>**Screw**|**10-32**<br>**Screw**|**M5**<br>**Screw**| |.05 to 30|X|X|X||| |30.1 to 50||||X|X| **Series with Auxiliary Switch** Note: - A: Terminal protrusion dimensions are referenced from back mounting panel. B: Main terminals are male push-on type .250 [6.35] wide x 0.31 [.79] thick x .375 [9.53] long or 8-32 x .187 [4.75] screw type. Metric screw terminals are M4 x 5mm (<=30A): M5 x 5mm screw type (>30A). On VDE approved builds with screw terminals, external tooth lockwashers are supplied. On VDE approved builds with push-on terminals a soldered connection is required above 25 amperes. **==> picture [47 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> C<br>NO<br>NC<br>BREAKER IN<br>OFF POSITION<br>**----- End of picture text -----**<br> _IAG Series - Configurations_ **108** **==> picture [612 x 61] intentionally omitted <==** ## **Relay Trip** This permits the overload sensing coil to be placed in a circuit which is electrically isolated from the trip contacts. The coil may be actuated by sensors monitoring pressure, flow, temperature, speed, etc. Other typical applications include crowbar, interlock and emergency /rapid shutdown circuitry. Trip may be accomplished by voltage or current, which must be removed after trip. **==> picture [158 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> .230 2.52 MAX.<br>[5.84] [64.00]<br>(See Note A)<br>.620<br>[15.75]<br>1.380<br>[35.05]<br>1.530<br>[38.86]<br>Relay<br>**----- End of picture text -----**<br> ## **Dual Coil** By combining two electrically independent coils on a common magnetic circuit, it is possible to provide contact opening when either an over-current or trip voltage is applied to the respective coils. One coil will be a current trip coil with standard specifications. The second, or dual coil, can be used to provide a control function permitting contact opening from a remote interlock or other transducer functions. Standard coils are 6, 12, 24, 48, 120 and 240 volts. Tripping is instantaneous and must be removed (usually selfinterrupting) after trip. ## **Voltage Trip** Sometimes called “dump circuits” or “panic trip circuits,” these units make it possible to open main power contacts with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt or relay configurations. **==> picture [220 x 440] intentionally omitted <==** **----- Start of picture text -----**<br> .230 2.52 MAX.<br>[5.84] [64.00]<br>(See Note A)<br>1.380<br>[35.05]<br>1.530<br>[38.86] Dual Coil<br>.230 2.52 MAX.<br>[5.84] [64.00]<br>(See Note A)<br>.620<br>[15.75]<br>1.380<br>[35.05]<br>1.530<br>[38.86]<br>Dual Coil<br>Optional Barriers (IEG Only)<br>.571<br>[14.50]<br>2.000<br>[50.80]<br>Note: Tolerance ± .015 [.38] unless noted.<br> Dimensions in brackets [ ] are millimeters.<br>**----- End of picture text -----**<br> _IAG Series - Configurations_ http://airpax.sensata.com **109** ## **TYPICAL RESISTANCE / IMPEDANCE** |**TYPICAL RESISTANCE / IMPEDANCE**|**TYPICAL RESISTANCE / IMPEDANCE**|**TYPICAL RESISTANCE / IMPEDANCE**|**TYPICAL RESISTANCE / IMPEDANCE**| |---|---|---|---| |**Current Ratings**<br>**(Amps)**|**Impedance**||| ||**DC**<br>**(ohms)**|**AC, 50/60Hz**<br>**(ohms)**|**AC, 400Hz**<br>**(ohms)**| ||**_51, 52, 53, 59_**|**_61, 62, 63, 69_**|**_41, 42, 43, 49_**| |0.200|45.8|28.5|71.94| |1.00|1.38|1.10|2.85| |2.00|0.371|0.29|0.76| |5.00|0.055|0.051|0.12| |10.0|0.017|0.016|0.032| |20.0|0.006|0.006|0.010| |30.0|0.003|0.004|0.006| |50.0|0.0019|0.0018|—| |_DCR and Impedance based on 100% rated current applied and stabilized for_<br>_a minimum of one hour. Tolerance .05-2.5 amperes ± 20%: 2.6 -20 amperes_<br>_± 25%, 21-50 amperes ± 50%. Consult factory for special values and for coil_<br>_impedance of delays not shown._|||| ## **OPERATING CHARACTERISTICS** ## **Inrush Pulse Tolerance** The following table provides a comparison of inrush pulse tolerance with and without the inertial delay feature for each of the 50/60Hz delays. Pulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. The table at left provides a guide to determine if the inertia delay feature is required. Consult factory for further assistance. ## **INRUSH PULSE TOLERANCE** |**INRUSH PULSE TOLERANCE**|**INRUSH PULSE TOLERANCE**| |---|---| |**Delay**|**Pulse Tolerance**| |61, 62, 63, 71, 72, 73|10 times rated current (approx)| |61F, 62F, 63F, 71F, 72F, 73F|12 times rated current (approx)| |64, 65, 66|25 times rated current (approx)| ## **PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS** |**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS**| |---|---|---|---|---|---|---|---|---| |**Delay**|**100%**|**125%**|**150%**|**200%**|**400%**|**600%**|**800%**|**1000%**| |41|No Trip|MayTrip|.500 to 8.0|.150 to 1.9|.020 to .40|.006 to .25|.004 to .1|.004 to .05| |42|No Trip|MayTrip|5 to 70|2.2 to 25|.40 to 5.0|.012 to 2|.006 to .2|.006 to .15| |43|No Trip|MayTrip|35 to 350|12 to 120|1.5 to 20|.012 to 2.2|.01 to .22|.01 to .1| |49|No Trip|MayTrip|.100 Max|.050 Max|.020 Max|.020 Max|.020 Max|.020 Max| |51*|No Trip|.500 to 6.5|.300 to 3.0|.100 to 1.2|.031 to .500|.011 to .25|.004 to .1|.004 to .08| |52*|No Trip|2 to 60|1.8 to 30|1 to 10|.15 to 2.0|.015 to 1|.008 to .5|.006 to .1| |53*|No Trip|80 to 700|40 to 400|15 to 150|2 to 20|.015 to 9|.015 to .55|.012 to .2| |59*|No Trip|.120 Max|.100 Max|.050 Max|.022 Max|.017 Max|.017 Max|.017 Max| |61*|No Trip|.700 to 12|.35 to 7.0|.130 to 3.0|.030 to 1|.015 to .3|.01 to .15|.008 to .1| |62*|No Trip|10 to 120|6 to 60|2 to 20|.2 to 3.0|.015 to 2|.015 to .8|.01 to .25| |63*|No Trip|50 to 700|30 to 400|10 to 150|1.5 to 20|.015 to 10|.013 to .85|.013 to .5| |64|No Trip|.7 to 12|.35 to 7|.13 to 3|.030 to 1|.017 to .3|.01 to .16|.008 to .1| |65|No Trip|10 to 120|6 to 60|2 to 20|.2 to 3|.02 to 2|.017 to .76|.01 to. 6| |66|No Trip|50 to 700|30 to 400|10 to 150|1.5 to 20|.4 to 10|.014 to 5|.014 to 3| |69*|No Trip|.120 Max|.100 Max|.050 Max|.022 Max|.017 Max|.017 Max|.017 Max| |71**|No Trip|.440 to 10|.300 to 7|.100 to 3.0|.03 to 1|.012 to .3|.004 to .15|.004 to .1| |72**|No Trip|1.8 to 100|1.7 to 60|1 to 20|.15 to 3|.015 to 2|.008 to .79|.006 to .28| |73**|No Trip|50 to 600|30 to 400|10 to 150|1.8 to 20|.015 to 10|.015 to .88|.011 to .50| |79**|No Trip|.120 Max|.100 Max|.050 Max|.023 Max|.016 Max|.015 Max|.015 Max| |_*CEG type units are available only with 51, 52, ,53 and 59 delays LEG type units are available only with 61, 62, 63 and 69 delays_<br>_**135% minimum trip point for delays 71, 72, 73 and 79_||||||||| _IAG Series - Operating Characteristics_ **110** **==> picture [612 x 61] intentionally omitted <==** ## **DELAY CURVES (IAG/IUG/IEG/CEG/LEG)** ## **400Hz, DC, 50/60Hz Delay Curves (typ)** A choice of delays is offered for DC, 50/60Hz and 400Hz applications. Delays 49, 59 and 69 provide fast acting, instantaneous trip and are often used to protect sensitive electronic equipment (not recommended where known inrush exists). Delays 41, 51 and 61 have a short delay for general purpose applications. Delays 42, 52 and 62 are long enough to start certain types of motors and most transformer and capacitor loads. Delays 43, 53 and 63 are long delays for special motor applications at 400Hz, DC and 60Hz. CEG type units are only available in 51, 52, 53 and 59 delay curves. LEG type units are only available in 61, 62, 63 and 69 delay curves. **==> picture [485 x 361] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>1000 DELAY 61 1000 DELAY 62<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 .001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>125 125<br>PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT<br>10000 10000<br>1000 DELAY 63 1000 DELAY 69<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 .001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>125 125<br>PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT<br>MAY TRIP MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>MAY TRIP<br>MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>**----- End of picture text -----**<br> _IAG Series - Delay Curves_ http://airpax.sensata.com **111** ## **DELAY CURVES (IAG/IUG/IEG/CEG) DC Delay Curves (typ)** _IAG Series - Delay Curves_ **112** **==> picture [612 x 61] intentionally omitted <==** ## **DELAY CURVES (IAG/IUG/IEG)** **Multi-frequency - DC, 50/60Hz Delay Curves (typ)** **==> picture [539 x 393] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>1000 DELAY 71 1000 DELAY 72<br>100 100<br>10<br>1<br>01 01<br>001 001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>135 PERCENT OF RATED CURRENT 135 PERCENT OF RATED CURRENT<br>10000 10000<br>1000 DELAY 73 1000 DELAY 79<br>100 100<br>10 10<br>1 1<br>1 1<br>01 01<br>001 001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>135 PERCENT OF RATED CURRENT 135<br>MAY TRIP MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>MAY TRIP<br>MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>**----- End of picture text -----**<br> _IAG Series - Delay Curves_ http://airpax.sensata.com **113** ## **DELAY CURVES (IAG/IUG/IEG)** **400Hz Delay Curves (typ)** **==> picture [203 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 41<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 42<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>AY TRIP<br>M<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [202 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 43<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [203 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 49<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>TIME IN SECONDS MAY TRIP<br>**----- End of picture text -----**<br> _IAG Series - Delay Curves_ **114** **==> picture [612 x 61] intentionally omitted <==** ## **SPECIFICATIONS** ## **Trip Free** Will trip open on overload, even when forcibly held in the ON position. This prevents the operator from damaging the circuit by holding on the protector. ## **Vibration** Circuit protector shall not trip when vibrated per MIL-STD-202, Method 204, Test Condition A with 100% rated current applied to delayed units and 80% rated current to instantaneous units. ## **Trip Indication** The operating handle moves positively to the OFF position on overload. ## **Ambient Operation** IAG/IUG/IEG/CEG/LEG protectors operate in temperatures between –40° C to +85° C. ## **VDE Approval** IEG is VDE approved under VDE 0642 (EN60934). The IEG has 8mm creepage and clearance between the main circuit and the following areas: A. Operator accessible area around the handle. B. The mounting inserts or brackets. C. The auxiliary switch circuit. ## **Insulation Resistance** D. Between poles. Not less than 100 megohms at 500 volts DC. ## **Dielectric Strength** IAG/IUG/IEG/CEG/LEG protectors withstand 3750Vac, 60Hz for 60 seconds between all electrically isolated terminals, except auxiliary switch terminals shall withstand 600Vac, 60Hz for REG and REC types. Four terminal dual coil and relay construction (not offered in the IEG) will withstand 1500Vac. Care must be taken to maintain spacings at the terminals when wired. The VDE approval for standard terminals is not for use with bare wire. A crimp type lug is required. In addition, all VDE approved units will be in compliance with specific CE Directives. These units will be marked as CE Compliant. ## **UL1500 (Marine Ignition Protected)** IDG/IDGH is approved for Marine Ignition Protection ## **Endurance** Operating as a switch, the operating life exceeds 10,000 operations at a rate of 6 per minute when tested as follows: 6000 OPS @ rated current plus 4000 OPS @ at no load. ## **Electrical Characteristics** .050-50 amperes; 80Vdc Max., 240Vac Max., 50/60Hz and .050-30 amperes: 250Vac Max., 400Hz. Units above 30 amps are not suitable for across-the-line motor starting. ## **UL489A Listed** The CEG is dimensionally the same as the popular IEG, but provides UL listing to UL489A. Available in one to three poles, in series, series with auxiliary switch, shunt, dual coil and voltage trip configurations. As a circuit breaker, the CEG provides communication equipment manufacturers with a UL listed circuit breaker in a very compact package that meets the stringent environmental requirements of today’s marketplace. This makes the CEG ideal for switching, transmission and wireless applications. ## **Auxiliary Switch** When supplied shall be SPDT configuration. Non VDE approved switches have a maximum UL rating of 10.0 amperes, 250 volts, 60Hz; 3.0 amperes, 50 volts DC, 1 amperes, 80 volts DC (REC) type or 0.1 amperes, 125 volts, 60Hz. (REG type). VDE approved switches have a maximum UL rating of 10.0 amperes, 250 volts, 60Hz, 1 amperes, 80 volts DC (REG type); or 0.1 amperes, 125 volts, 60Hz (REG type); or 0.1 amperes, 125 volts, 60Hz (REG type). ## **Moisture Resistance** Meets all the requirements of MIL-PRF-55629 when tested in accordance with Method 106 of MIL-STD-202. ## **Salt Spray (Corrosion)** Meets the requirements of MIL-PRF-55629 when tested in accordance with Method 101 of MIL-STD-202. ## **Shock** Circuit protectors shall not trip when tested per MIL-STD-202, Method 213, Test Condition I with 100% rated current applied to delayed units, except 90% current in plane 4 (i.e., handle down). Instantaneous units shall have 80% rated current applied in all planes. ## **Construction** Series, shunt, relay and series with auxiliary switch available in various delays and combinations. ## **UL489 Listed** The LEG is dimensionally the same as the popular IEG, but provides UL listing to UL489. Available with one or two poles, in series, series with auxiliary switch, shunt and three-terminal dual coil configurations. As a circuit breaker, the LEG provides equipment manufacturers with a UL listed magnetic hydaulic circuit breaker in the most compact package available on the market. |**APPROXIMATE WEIGHT PER POLE (1 TO 6 POLES AVAILABLE)**|**APPROXIMATE WEIGHT PER POLE (1 TO 6 POLES AVAILABLE)**| |---|---| |**Ounces**|**Grams**| |2.2|62.4| ||| |**RECOMMENDED TORQUE SPECIFICATIONS**|| |**Component**|**Torque (in-lbs)**| |6-32 Mounting Inserts|6 to 8| |M3 Mounting Screws|4 to 5| |8-32 Screw Terminals|10 to 12| |M4 Terminal Screws|10 to 12| |10-32 Screw Terminals|14 to 15| |M5 Screw Terminals|14 to 15| |1/2 - 32 Mounting Bushing|30 to 35| |_Where applicable, mechanical support must be provide to the terminals when_<br>_applying torque_|| _IAG Series - Specifications_ http://airpax.sensata.com **115** **==> picture [497 x 578] intentionally omitted <==** **----- Start of picture text -----**<br> AGENCY APPROVALS<br>IAG/IUG/IEG Supplementary Protectors Rated Current (Amps) Short Circuit Rating (SC), Amps<br>Max Voltage Frequency (Hz) Phase Minimum Poles UL/CSA TÜV UL1077 & CSA TÜV<br>80 DC — 1 .02 to 50 .10 to 30 U2, 7500 4000<br>125 50/60 1 1 .02 to 50 — U2, 3000 —<br>125 50/60 1 1 .02 to 30 — C1, 5000(3) —<br>125 50/60 1 1 .02 to 50 — U3, 1000 —<br>125 / 250 50/60 1 2 .02 to 50 — U1, 3000 —<br>125 / 250 50/60 1 1 2/1 - 30/15 — C2, 5000(1) —<br>240 50/60 1 & 3 1 .02 to 50 — U1, 2000 —<br>240 50/60 1 & 3 1 .02 to 50 — C2, 5000(1) —<br>250 50/60 1 1 .02 to 2 — U2, 5000 —<br>250 50/60 1 & 3 1 .02 to 30 .10 to 50 U1, 2000 2000<br>250 50/60 1 & 3 1 .02 to 30 — C2, 3500(2) —<br>250 (4) 50/60 1 & 3 1 .02 to 30 — C1, 3500(2) —<br>250 (4) 50/60 1 & 3 1 .02 to 30 — U1, 1000 —<br>250 (5) 50/60 1 2 .02 to 50 — U3, 1000 —<br>250 (5) 50/60 3 3 .02 to 50 — U3, 1000 —<br>277 50/60 1 1 .02 to 30 — U2, 2000 —<br>277 50/60 1 1 .02 to 30 — C2, 5000(2) —<br>250 400 1 & 3 1 .02 to 30 — U2, 1500 —<br>250 400 3 — .02 to 30 — U3, 200 —<br>IDG Supplementary Protectors<br>Max Voltage Frequency (Hz) Phase Minimum Poles UL/CSA TÜV UL1077 & CSA TÜV<br>48 DC — 1 .02-50 — U2, 5000 —<br>65 DC — 1 .02-50 — U2, 3000 —<br>125 50/60 1 1 .02-50 — U2, 2000 —<br>125/250 50/60 1 2 .02-50 — U2, 1500 —<br>250 50/60 1 & 3 1 .02-30 — U1, 1000 —<br>CEG Communications Equipment Circuit Breakers<br>Max Voltage Frequency (Hz) Phase Minimum Poles UL/CSA TÜV UL489A TÜV<br>80 DC — 1 .05-15 — 5000 —<br>LEG Circuit Breakers<br>Max Voltage Frequency (Hz) Phase Minimum Poles UL/CSA TÜV UL489 TÜV<br>125 50/60 1 1 .05-30 .10-30 5000 2000<br>120/240 50/60 1 2 1-30 .10-30 5000 2000<br>Notes: (1) With 125 A max. series fuse; (2) With 80 A max. series fuse; (3) With 50 A max. circuit breaker; (4) With blocked vent construction;<br>(5) Non-standard construction. “Fit for further use” approval<br>**----- End of picture text -----**<br> ## General notes: All supplementary protectors are of the overcurrent (OC) type The family of protectors has been evaluated for end use application for use groups (UG) A, B, C and D The terminals (FW) are suitable for factory wiring only (0) The maximum voltage ratings for which the protectors have been tested are shown in the chart The current is the amperage range that the protectors have been tested The tripping current (TC) for all of the protectors is “1” (in the range of 125% to 135% of ampere rating except for the 400Hz protectors which is “2” (more than 135% of ampere rating) The overload rating (OL) - designates whether the protector has been tested for general use or motor starting applications. - 0 – tested at 1.5 times amp rating for general use - 1 – tested at 6 times AC rating or 10 times DC rating for motor starting The short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below: - C – Indicates short circuit test was conducted with series overcurrent protection - U – Indicates short circuit test was conducted without series overcurrent protection - 1 – Indicates a recalibration was not conducted as part of the short circuit testing - 2 – Indicates a recalibration was performed as part of the short circuit testing - 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further Use” rating _IAG Series - Specifications_ **116** **==> picture [612 x 61] intentionally omitted <==** ## **IAG/IUG/IEG/CEG DECISION TABLES** The ordering code for IAG/IUG/IEG/CEG/IDG circuit protectors may be determined by following the decision steps in the tables shown here. The coding given permits a self-assigning part number but with certain limitations. Special applications may require a factory-assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table. With these, it is suggested that order entry be by description and/or drawings and a part number will be established. Additionally, it is standard policy to establish a factory-assigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control. When specifying a circuit protector for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection. For example, the following is the code for a single pole, IEG quick-connect type terminal, series unit with auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, a rating of 20 amperes, a black marked handle and is VDE approved. To determine the ordering number for your particular IAG/IUG/IEG/CEG unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have. Notes: - A. It is recommended that power leads be soldered to circuit protectors having push-on type terminals for current trip ratings above 20 amperes. - B. When “A” (metric thread mounting) is specified in the sixth decision in combination with screw terminal option in the second decision, metric screw terminals are supplied. - C. IEG, IEGH, IEGS, IEGHS, IEGX and IEGZX circuit protectors are designed to meet 8mm creepage and clearance requirements for installation Category III, Pollution Degree 3, Case A as measured in IEC 664. Intended for use in equipment designed to comply with IEC 601 and 950 and VDE 0804 and 0805. **==> picture [260 x 289] intentionally omitted <==** **----- Start of picture text -----**<br> 1 First Decision<br>Select Type and Terminal<br>Type Description Handle and Mounting Options<br>IAGIUG*IUG* Standard toggle/mounting,<br>IEG** One toggle handle per unit no designation required<br>CUG+ S Toggle w/ snap-in mounting<br>CEG++<br>IAGH X Rocker w/ standard mounting*g**<br>IUGH*IEGH**IEGH** One toggle handle per pole ZX ZX Rocker w/ integral mounting*<br>CUGH+ BX BX Rocker w/ integral mounting<br>CEGH++<br>IDG*** One toggle handle per unit,marine ignition protectionmarine ignition protection Note: Add "F" for flat screw terminals N Sealed toggle w/bushing mounting**<br>IDGH*** One toggle handle per pole * Not available on mid-trip units** Available only on IAG, IUG units** Available only on IAG, IUG units<br>marine ignition protectiongnition protectionnition protectionprotectionrotection<br>IMG** One toggle handle per unit<br>CMG++ mid-trip indication<br>IMGH** One toggle handle per pole 2 Second Decision<br>CMGH++ mid-trip indication Poles and Terminals<br>*UL Recognized, CSA Certified<br>**UL Recognized, CSA Certified, VDE Approved Push-on Screw<br>*** UL Recognized UL1500 Terminals Terminals<br>+ UL489A Listed CSA Certified<br>++ UL489AListed CSA Certified VDE Approved 1 6 Single pole<br>11 66 Two pole<br>111 666 Three pole<br>1111 6666 Four pole<br>*Not available in toggle seal handle type.<br>Example:<br>**----- End of picture text -----**<br> **==> picture [343 x 581] intentionally omitted <==** **----- Start of picture text -----**<br> 1 First Decision<br>Select Type and Terminal<br>Type Description Handle and Mounting Options<br>IAGIUG*IUG* Standard toggle/mounting,<br>IEG** One toggle handle per unit no designation required<br>CUG+ S Toggle w/ snap-in mounting<br>CEG++<br>IAGH X Rocker w/ standard mounting*g**<br>IUGH*IEGH**IEGH** One toggle handle per pole ZX ZX Rocker w/ integral mounting*<br>CUGH+ BX BX Rocker w/ integral mounting<br>CEGH++<br>N Sealed toggle w/bushing mounting**<br>IDG*** One toggle handle per unit,marine ignition protectionmarine ignition protection Note: Add "F" for flat screw terminals<br>IDGH*** One toggle handle per pole * Not available on mid-trip units** Available only on IAG, IUG units** Available only on IAG, IUG units<br>marine ignition protectiongnition protectionnition protectionprotectionrotection<br>IMG** One toggle handle per unit<br>CMG++ mid-trip indication<br>IMGH** One toggle handle per pole 2 Second Decision<br>CMGH++ mid-trip indication Poles and Terminals<br>*UL Recognized, CSA Certified<br>**UL Recognized, CSA Certified, VDE Approved Push-on Screw<br>*** UL Recognized UL1500 Terminals Terminals<br>+ UL489A Listed CSA Certified<br>++ UL489AListed CSA Certified VDE Approved 1 6 Single pole<br>11 66 Two pole<br>111 666 Three pole<br>1111 6666 Four pole<br>*Not available in toggle seal handle type.<br>Example:<br>IEG 1 - 1REC4 - 61 - 20.0 - 01 - V<br>1 2 3 4 5 6 7<br>3 Third Decision 4 Fourth Decision<br>Internal Configuration Frequency and Delay<br>-0 Switch only SW Switch only<br>-1 Series -41 400Hz short delay<br>-1REC4 Series w/ auxiliary switch * -42 400Hz long delay<br>.110 quick connect -43 400Hz motor start<br>-1REC5 Series w/ auxiliary switch * -49 400Hz 150% instant trip<br>.187 quick connect<br>-51 DC short delay*<br>-1REG4 Series w/ auxiliary switch (gold contacts)* -52 DC long delay*<br>.110 quick connect -53 DC motor start*<br>-1RS4 Series w/ alarm switch, -59 DC 125% instant trip*<br>electrical trip,<br>.110 Q.C. terminals -61 50/60Hz short delay<br>-1RLS4 Series w/ alarm switch, -62 50/60Hz long delay<br>electrical trip, -63 50/60Hz motor start<br>.110 Q.C. terminals (mid-trip only)<br>-64 50/60Hz short delay<br>-3 Shunt<br>-65 50/60Hz long delay<br>-4 Relay -66 50/60Hz motor start<br> * Only one auxiliary switch is normally supplied on two or three pole units. Switch is located in the right-hand pole -69 50/60Hz 125% instant trip<br> (viewed from terminal end) unless otherwise specified.<br>-71 DC/60Hz short delay<br>-72 DC/60Hz long delay<br>-73 DC/60Hz motor start<br>-79 DC/60 Hz 135% instant trip<br>For addition of inertial delay, add an ìFî to any<br>delay numeral.<br>* CEG types are only available with DC ratings<br>**----- End of picture text -----**<br> **V** = VDE and CCC Approved ## **C** = CCC Approved The shaded areas denote VDE and CCC (if applicable) approval options. This approval requires the addition of a V at the end of the part number. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be VDE or CCC Approved, but other approvals still apply. This approval requires the addition of a C at the end of the part number. The unit will not be VDE Approved. **117** _IAG Series - Decision Tables_ http://airpax.sensata.com **==> picture [568 x 339] intentionally omitted <==** **----- Start of picture text -----**<br> 5 Fifth Decision 6 Sixth Decision ROCKER HANDLE COLOR INDICATING COLOR<br>ON<br>Rated Current Optional ON<br>ROCKER HANDLE COLOR<br>Standard ratings listed. For other ratings, Standard hardware. No designation required. OFF<br>please contact the factory. -A Metric thread mounting inserts and terminals INDICATING COLOR<br> .100 10.0<br> .250 .500 15.0 20.0 -B-C Barriers*277V (50/60Hz only) (See note 3) LINE MOUNTING/INDICATOR CODE:INDICATION “ON”A, B, C LINE MOUNTING/INDICATOR CODE:INDICATION “OFF”F, G, H<br> .750 1.00 30.0 35.0* -G Handle guard, (available in ZX, BX and snap-in versions only) LINELOAD OFFON O OFFONO LINEOFF LOADON LINE LOAD LINEOFF LOADON<br> 2.50 40.0* -L Handle lock FIG. 1 FIG. 2MARKING DETAIL “A” (SEE TABLE)FIG. 3 FIG. 4 FIG. 5 FIG. 6<br> 5.00 50.0* -M Handle in opposite pole (2 pole only)<br> 7.50 -Q APG style “FAT” handle INDICATING COLOR<br>* IDG/IDGH is rated for 30 amps max. -S Face plate sides flush with protector (see note 4) OFF<br>LINE<br>-X Handle guard with no actuation feature (BX rocker only) (Not available with mid-trip ON ROCKER HANDLE COLOR<br>indication)<br>7 Handle Color and Marking SelectionSeventh Decision Notes: 1. One or more descriptions may be used as required.2. When this is not used, table one may be substituted and U.S. thread MOUNTING/INDICATOR CODE:INDICATION “ON”J, K, L<br>will be supplied. Unit will be rated at 250V (50/60Hz only.)<br>Toggle Handle 3. VDE approved at 250VAC4. IEGS standard face plate has beveled sides(see pg.90) LINE OFF O OFFO LOAD LINE LOAD LINE LOAD LINE<br>Marked * Not available on snap-in units LOAD ON ON ON OFF ON OFF<br>ON-OFF FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6<br>Color Unmarked I-O<br>MARKING DETAIL “B” (SEE TABLE)<br>Black -00 -01 (STD)<br>Yellow -10 -11<br>Red -20 -21<br>Blue -30 -31<br>LINE<br>Green -40 -41<br>Orange -60 -61 INDICATION “OFF”<br>MOUNTING/INDICATOR CODE: M, N, P, R<br>White -90 -91<br>LOAD ON LINE LOAD<br>Handle marking color is white on black, red, blue & green LINE O OFFO OFFO ON<br>handles and black on white, yellow and orange handles.See alternate 7th decision below for X, ZX & BZ rocker handles. FIG. 2 FIG. 3 FIG. 6<br>MARKING DETAIL “C” (SEE TABLE)<br>ONI<br>OFFO<br>OFF<br>O O<br>O O<br>**----- End of picture text -----**<br> **==> picture [404 x 281] intentionally omitted <==** **----- Start of picture text -----**<br> 7 Seventh Decision<br>Rocker Handle Color, Indicator Color and Marking Selection (See Notes)<br>IAGX, IUGX, IEGX, IAGZX, IUGZX, IEGZX, CUGZX, CEGZX Rocker Handle (Single Rocker Color)<br>Vertical Mounting Horizontal Mounting<br>Rocker On-Off On-Off<br>Handle Indicating Marking On-Off I-O I-O On-Off I-O I-O Marking<br>Color Color Color Indicates: Unmarked Fig.1 Fig.2 Fig.3 Fig.4 Fig.5 Fig.6 Detail<br>Black N/A White N/A -00 -01 -02 -03 -04 -05 -06<br>Red N/A White N/A -20 -21 -22 -23 -24 -25 -26<br>Grey N/A Black N/A -40 -41 -42 -43 -44 -45 -46 A<br>Orange N/A Black N/A -50 -51 -52 -53 -54 -55 -56<br>White N/A Black N/A -90 -91 -92 -93 -94 -95 -96<br>IAGZX, IUGZX, IEGZX, CUGZX, CEGZX Rocker Handle (Dual Rocker Color)<br>Black White White On -A0 -A1 -A2 -A3 -A4 -A5 -A6<br>Black Red White On -B0 -B1 -B2 -B3 -B4 -B5 -B6<br>Black Green White On -C0 -C1 -C2 -C3 -C4 -C5 -C6 A<br>Black White White Off -F0 -F1 -F2 -F3 -F4 -F5 -F6<br>Black Red White Off -G0 -G1 -G2 -G3 -G4 -G5 -G6<br>Black Green White Off -H0 -H1 -H2 -H3 -H4 -H5 -H6<br>Black White White On -J0 -J1 -J2 -J3 -J4 -J5 -J6<br>Black Red White On -K0 -K1 -K2 -K3 -K4 -K5 -K6 B<br>Black Green White On -L0 -L1 -L2 -L3 -L4 -L5 -L6<br>IAGBX, IUGBX, IEGBX, CUGBX, CEGBX Rocker Handle (Dual Rocker Color)<br>Black White White Off -M0 N/A -M2 -M3 N/A -M5 -M6<br>Black Red Red Off -N0 N/A -N2 -N3 N/A -N5 -N6<br>C<br>Black Green Green Off -P0 N/A -P2 -P3 N/A -P5 -P6<br>Black Yellow Yellow Off -R0 N/A -R2 -R3 N/A -R5 -R6<br>Notes: A. Bezels of IAGBX, IUGBX, IEGBX, CUGBX, CEGBX are black.<br>B. Consult factory for other marking options.<br>**----- End of picture text -----**<br> _IAG Series - Decision Tables_ **118** **==> picture [612 x 61] intentionally omitted <==** ## **LEG DECISION TABLES** The ordering code for LEG circuit breakers may be determined by following the decision steps in the tables shown here. The coding given permits a self-assigning part number but with certain limitations. Special applications may require a factory-assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table. With these, it is suggested that order entry be by description and/or drawings and a part number will be established. Additionally, it is standard policy to establish a factoryassigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control. When specifying a circuit breaker for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection. For example, the following is the code for a single pole, LEG screw type terminal, series unit with auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, a rating of 20 amperes, a black marked handle and is VDE approved. To determine the ordering number for your particular LEG unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have. Notes: - A. When “A” (metric thread mounting) is specified in the sixth decision in combination with screw terminal option in the second decision, metric screw terminals are supplied. **==> picture [326 x 551] intentionally omitted <==** **----- Start of picture text -----**<br> 1 First Decision<br>Select Type and Terminal<br>Type Description Handle and Mounting Options<br>LEG One toggle handle per unit Standard toggle/mounting,<br>One toggle handle per unit no designation required<br>LMG mid-trip indication S Toggle w/ snap-in mounting<br>LEGH One toggle handle per pole ZX ZX Rocker w/ integral mounting*<br>LMGH One toggle handle per pole mid-trip indication BX BX Rocker w/ integral mounting<br>Note: All types are UL489 listed, CUL certified Note: Add "F" for flat screw terminals<br>* Not available on mid-trip units<br>2 Second Decision<br>Poles and Terminals<br>Push-on Screw<br>Terminals Terminals<br>1 6 Single pole<br>11 66 Two pole<br>*Not available in toggle seal handle type.<br>Example:<br>LEG 6 - 1REC4 - 61 - 20.0 - 01 - V<br>1 2 3 4 5 6 7<br>3 Third Decision 4 Fourth Decision<br>Internal Configuration Frequency and Delay<br>-1 Series -61 50/60Hz short delay<br>-1REC4 Series w/ auxiliary switch * -62 50/60Hz long delay<br>.110 quick connect<br>-63 50/60Hz motor start<br>-1REC5 Series w/ auxiliary switch * -69 50/60Hz 125% instant trip<br>.187 quick connect<br>For addition of inertial delay, add an “F” to any<br>-1REG4 Series w/ auxiliary switch* (gold contacts) delay numeral. (Not available on units rated at 125VAC).* CEG types are only available with DC ratings<br>.110 quick connect<br>-1RS4 Series w/ alarm switch*,<br>electrical trip,<br>.110 Q.C. terminals V = VDE Approved<br>-1RLS4 Series w/ alarm switch*, The shaded areas denote VDE approval<br>electrical trip, mid-trip only, options. This approval requires the addition<br>.110 Q.C. terminals of a V at the end of the part number. The V<br>will be added to any part number formed<br>entirely from shaded decisions. If<br>-3 Shunt non-shaded areas are selected, the unit will<br>not be VDE Approved, but other<br> * Only one auxiliary switch is normally supplied on two pole units. Switch is located in the right-hand pole (viewed from approvals still apply.<br> terminal end) unless otherwise specified.<br>C = CCC Approved<br>**----- End of picture text -----**<br> This approval requires the addition of a C at the end of the part number. The unit will not be VDE Approved. - B. LEG, LEGH, LEGS, LEGHS, LEGZX and LEGBX circuit breakers are designed to meet 8mm creepage and clearance requirements for installation Category III, Pollution Degree 3, Case A as measured in IEC 664. Intended for use in equipment designed to comply with IEC 601 and 950 and VDE 0804 and 0805. _LEG Series - Decision Tables_ http://airpax.sensata.com **119** **==> picture [380 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> 5 Fifth Decision 6 Sixth Decision<br>Rated Current Optional<br>Use three numbers to print required current value Standard hardware. No designation required.Metric thread mounting inserts and terminals<br>between .100 amps minimum and 30.0 amps maximum.<br>For example, use: -A Metric thread mounting inserts and terminals<br>.100 or 2.00 or 10.0 -G Handle guard, (available in ZX, BX and snap-in versions only)<br>versions only)<br>**----- End of picture text -----**<br> **==> picture [339 x 215] intentionally omitted <==** **----- Start of picture text -----**<br> 6 Sixth Decision ROCKER HANDLE COLOR INDICATING COLOR<br>ON<br>Optional ON<br>ROCKER HANDLE COLOR<br>-A Standard hardware. No designation required.Metric thread mounting inserts and terminals INDICATING COLOR OFF<br>-G Handle guard, (available in ZX, BX and snap-in versions only) LINE MOUNTING/INDICATOR CODE:INDICATION “ON”A, B, C LINE MOUNTING/INDICATOR CODE:INDICATION “OFF”F, G, H<br>-L Handle lock LOAD ON ON LINE LOAD LINE LOAD LINE LOAD<br>-S Face plate sides flush with breaker LINE FIG. 1OFF FIG. 2O FIG. 3OFFO OFFFIG. 4ON FIG. 5 OFFFIG. 6ON<br>-X* Handle guard with no actuation feature<br>(BX rocker only) MARKING DETAIL “A”<br>-Z "Z" Barriers<br>Notes: INDICATING COLOR<br>1. One or more descriptions may be used as required.2. When this is not used, table one may be substituted and U.S. thread OFF<br> will be supplied. Unit will be rated at 250V (50/60Hz only.)3. LEGS standard face plate has beveled sides(see pg. 90)* Not available on mid-trip units LINE ON ROCKER HANDLE COLOR<br>MOUNTING/INDICATOR CODE:INDICATION “ON”J, K, L<br>LINE OFF O OFFO LOAD LINE LOAD LINE LOAD LINE<br>LOAD ON ON ON OFF ON OFF<br>FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6<br>OFF<br>O O<br>O O<br>**----- End of picture text -----**<br> **==> picture [134 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 7 Seventh Decision<br>Handle Color and Marking Selection<br>Toggle Handle<br>Marked<br>ON-OFF<br>Color Unmarked I-O<br>Black -00 -01 (STD)<br>Yellow -10 -11<br>Red -20 -21<br>Blue -30 -31<br>Green -40 -41<br>Orange -60 -61<br>White -90 -91<br>Handle marking color is white on black, red, blue & green<br>handles and black on white, yellow and orange handles.<br>See alternate 7th decision below for ZX & BZ rocker handles.<br>**----- End of picture text -----**<br> **==> picture [68 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> MARKING DETAIL “B”<br>LINE<br>INDICATION “OFF”<br>MOUNTING/INDICATOR CODE: M, N, P, R<br>LOAD ON LINE LOAD<br>LINE O OFFO OFFO ON<br>FIG. 2 FIG. 3 FIG. 6<br>ONI<br>OFFO<br>**----- End of picture text -----**<br> **==> picture [64 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> MARKING DETAIL “C”<br>**----- End of picture text -----**<br> **==> picture [422 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> 7 Seventh Decision<br>Rocker Handle Color, Indicator Color and Marking Selection (See Note)<br>LEGZX Rocker Handle (Single Rocker Color)<br>Vertical Mounting Horizontal Mounting<br>Rocker On-Off On-Off<br>Handle Indicating Marking On-Off I-O I-O On-Off I-O I-O Marking<br>Color Color Color Indicates: Unmarked Fig.1 Fig.2 Fig.3 Fig.4 Fig.5 Fig.6 Detail<br>Black N/A White N/A -00 -01 -02 -03 -04 -05 -06<br>Red N/A White N/A -20 -21 -22 -23 -24 -25 -26<br>Grey N/A Black N/A -40 -41 -42 -43 -44 -45 -46 A<br>Orange N/A Black N/A -50 -51 -52 -53 -54 -55 -56<br>White [N/A] Black [N/A] -90 -91 -92 -93 -94 -95 -96<br>LEGZX Rocker Handle (Dual Rocker Color)<br>Black White White On -A0 -A1 -A2 -A3 -A4 -A5 -A6<br>Black Red White On -B0 -B1 -B2 -B3 -B4 -B5 -B6<br>Black Green White On -C0 -C1 -C2 -C3 -C4 -C5 -C6 A<br>Black White White Off -F0 -F1 -F2 -F3 -F4 -F5 -F6<br>Black Red White [Off] -G0 -G1 -G2 -G3 -G4 -G5 -G6<br>Black Green White Off -H0 -H1 -H2 -H3 -H4 -H5 -H6<br>Black White White On -J0 -J1 -J2 -J3 -J4 -J5 -J6<br>Black Red White On -K0 -K1 -K2 -K3 -K4 -K5 -K6 B<br>Black Green White On -L0 -L1 -L2 -L3 -L4 -L5 -L6<br>LEGBX Rocker Handle (Dual Rocker Color)<br>Black White White Off -M0 N/A -M2 -M3 N/A N/A -M6<br>Black Red Red Off -N0 N/A -N2 -N3 N/A N/A -N6<br>C<br>Black Green Green Off -P0 N/A -P2 -P3 N/A N/A -P6<br>Black Yellow Yellow Off -R0 N/A -R2 -R3 N/A N/A -R6<br>Notes: A. Bezels of LEGBX are black.<br> B. Consult factory for other marking options.<br>**----- End of picture text -----**<br> _LEG Series - Decision Tables_ **120**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →