IS.AC12VDC2.5ADIN
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 30 W, 12 VDC, 2.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: INDUSTRIAL SHIELDS
- Product type:
- Available until stocks are exhausted Alternative available
- SVHC: To Be Advised
- Product Range: -
- No. of Outputs: 1 Output
- Output Power Max: 30W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 66.05 € |
| Current stock | 10+ |
| Lead time | 30 days |
- Universal Input 90 - 264 Vac - 100% Full Load Burn-in test - Cooling by Free Air convection - Led Indicators for DC Power ON and for DC Low - Protections against: Short Circuit, Over Voltage, Over Current and Over Temperature. 0 DIN Rail Power Supply 30W, 12Vdc ## Power Supply Unit **Revised January 2020** Preface This User Guide is been implemented by Boot & Work, S.L. working under the name Industrial Shields. ## **Purpose of the manual** The information contained in this manual can be used as a reference to operating, to functions, and to the technical data of the signal modules, power supply modules and interface modules. ## **Intended Audience** This User Guide is intended for the following audience: - Persons in charge of introducing automation devices. - Persons who design automation systems. - Persons who install or connect automation devices. - Persons who manage working automation installation. **Ref.** IS.AC12VDC2.5ADIN **1** Intended use or of Industrial Shields products ## Consider the following: Industrial Shields products should only be used for the cases of application foreseen in the catalogue and the associated technical documentation. If third-party products and components are used, they must have been recommended or approved by Industrial Shields. The correct and safe operation of the products requires that your transport, storage, installation, assembly, operation and maintenance have been carried out in a correct must respect the permissible ambient conditions. You should also follow the indications and warnings that appear in the associated documentation. The product / system dealt with in this documentation should only be handled manipulated by qualified personnel for the task entrusted and observing what is indicated in the documentation corresponding to it, particularly the safety instructions and warnings included in it. Due to their training and experience, qualified personnel are in a position recognize risks resulting from the handling or manipulation of such products / systems and to avoid possible hazards. Disclaimers ## Weights and Dimensions Dimensions and weights are nominal and they are not used for manufacturing purposes, even when tolerances are shown. ## Performance Data The performance data given in this manual is provided as a guide for the user determining suitability and does not constitute a warranty. It may represent the result INDUSTRIAL SHIELDS’s test conditions, and the users most correlate it to actual application requirements. Actual performance is subject to the INDUSTRIAL SHIELDS Warranty and Limitations of Liability. ## Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when features are changed, or published ratings or when significant construction changes are made. However, some specifications of the **Ref.** IS.AC12VDC2.5ADIN **2** products may be changed without any notice. When in doubt, special numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your INDUSTRIAL SHIELDS representative at any time to confirm actual specifications of purchased products. ## Errors and Omissions The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. These components may only be operated in closed housings or in higher-level control cabinets with protective covers that are closed, and when all of the protective devices are used. These components may only be handled by qualified and trained technical personnel who are knowledgeable and observe all of the safety information and instructions on the components and in the associated technical user documentation. When carrying out a risk assessment of a machine in accordance with the EU Machinery Directive, the machine manufacturer must consider the following residual risks associated with the control and drive components of a PDS. **Ref.** IS.AC12VDC2.5ADIN **3** ## **Table of Contents** |**General Description**|**5**| |---|---| |1.1. Electrical|5| |1.2. Input Parameters|5| |1.3. Output Parameters|6| |1.4. Protection|6| |1.5. Mechanical dimension|7| |1.6. Serigraphy|7| |**Operating Specifications:**|**8**| |2.1. Environment|8| |2.2. Safety/EMC|8| |**Applications and Maintenance**|**9**| |3.1. Series Operation|9| |3.2. Parallel Operation|10| |3.3. Din Rail Mounting|11| **Ref.** IS.AC12VDC2.5ADIN **4** ## 1 **General Description** ## 1.1. Electrical |**Nominal Input**<br>**Voltage**|**Output**<br>**Voltage**|**Output**<br>**Current**|**Ripple (Typ.)**|**Efficiency**<br>**(Typ.)**|**Certificate**| |---|---|---|---|---|---| |100-240 Vac|12 Vdc|2.5 A|42 mV|83%|CE, FCC, CB,<br>UL, CUL| ## 1.2. Input Parameters |**PARAMETER**|**CONDITIONS**|**MIN TYP MAX**|**MIN TYP MAX**|**MIN TYP MAX**|**UNITS**| |---|---|---|---|---|---| |Input Voltage||90||264|Vac| |Input<br>Frequency||47||63|Hz| |Input Current|Full load, Vin=115Vac<br>Full load, Vin = 230Vac||0,635<br>0,35||A<br>A| |Inrush Current|Cold start, Vin = 115Vac<br>Cold start, Vin = 230Vac|||30<br>60|A<br>A| ||1. This product is built inrush limiting circuit to protect the circuit from surge current damages<br>when the power is turned on. Malfunction can occur by repeating the input voltage on and off<br>rapidly. Therefore, sufficient interval should be given between turning on and off the power;<br>2. To avoid connecting the switch or fuse to input terminal (outside of the power supply), more<br>consideration should be given when selecting the parts that can endure the inrush current.||||| |Stand-by<br>power<br>consumption|Vin = 230Vac||1||W| |Surge voltage|L-N||2||KV| ||2. To avoid connecting the switch or fuse to input terminal (outside of the power supply), more|2. To avoid connecting the switch or fuse to input terminal (outside of the power supply), more|2. To avoid connecting the switch or fuse to input terminal (outside of the power supply), more|fuse to input terminal (outside of the power supply), more|fuse to input terminal (outside of the power supply), more| |---|---|---|---|---|---| ||consideration should be given when selecting the parts that can endure the inrush current.||||| |Stand-by|||||| |power|Vin = 230Vac||1||W| |consumption|||||| |Surge voltage|L-N||2||KV| **Ref.** IS.AC12VDC2.5ADIN **5** ## 1.3. Output Parameters |**PARAMETER**|**CONDITIONS**|**MIN**|**TYP**|**MAX**|**UNITS**| |---|---|---|---|---|---| |Output Voltage<br>accuracy|||±1||%| |Output Voltage<br>adjustment<br>range|||11.6-12.3||Vdc| ||Output voltage can be adjusted within above range by V-ADJ. variable resistance<br>inside of the power supply. When output voltage exceeds the range, the power supply<br>will be in failure or get into over voltage protection mode. To avoid the case that the<br>output voltage is higher than rated voltage, output current should be used under<br>rated current.||||| |Minimum Load||0|||A| |Line regulation|Vin from 100 Vac to<br>240 Vac||1||%| |Stand-by power<br>consumption|<br>Vout from min. to max.||1||%| |Turn-on delay<br>time|Full load, Vin = 115<br>Vac||100||ms| |Hold up time|Full load, Vin = 115<br>Vac||20||ms| ## 1.4. Protection |**Short Circuit**|Hiccup mode, it will recover automatically after fault condition is removed| |---|---| |**Over Voltage**|Over Voltage protection value 16V| ||(1) When output voltage exceeds above over voltage protection value or reversal<br>voltage occurs, the protection will be started and the output voltage will be cut off in<br>order to protect the power supply;<br>(2) The power supply will recover after the power is turned on again| |**Over Current**|Over Current protection value 4A| ||(1) When output voltage exceeds above over current protection value, the protection<br>will be started and the output voltage will be cut off in order to protect the power<br>supply;<br>(2) The power supply unit will recover automatically after the fault condition is<br>removed.| |**Over**<br>**Temperature**|Over Temp. protection value: 100 ± 10ºC| ||(1) When the ambient temperature exceeds above our temperature protection value,<br>the protection will be started and the output voltage will be cut off in order to protect<br>the power supply;<br>(2) The power supply unit will recover after the power is turned on again.| **6 Ref.** IS.AC12VDC2.5ADIN ## 1.5. Mechanical dimension Unit: mm Tolerance ± 1.0 ## 1.6. Serigraphy **Ref.** IS.AC12VDC2.5ADIN **7** ## 2 **Operating Specifications:** ## 2.1. Environment |**PARAMETER**|**CONDITIONS**|**MIN**|**TYP**|**MAX**|**UNITS**| |---|---|---|---|---|---| |Ambient<br>Operating<br>temperature|Startup at rated voltage|-35||70|ºC| |Operating<br>Relative<br>humidity|Non Condensing|20||95|%| |Storage<br>Temperature|Humidity 5 - 95% RH|-40||85|ºC| |MTBF|Full load, 220Vac input,<br>25ºC ambient temperature|200|||Khrs| |DC-OK led|LED (Green)<br>DC OK LED light will be ON when the power supply is properly operated||||| |DC-Lowled|LED (Red)<br>DC Low LED Light will be ON:<br>(1) When output voltage is below 85%(±2.5%) from the rated output voltage;<br>(2) When get over voltage, over current, over temperature and short circuit fault||||| |Cooling|Free air convection||||| |Mounting<br>Method|Vertical||||| |Dimensions<br>(WxHxD)|36.0 x 95.0 x 108.0 mm<br>(1.42 x 3.74 x 4.25 inch)||||| |Weight|250 g||||| |Packing|22pcs / 7.5Kg / 0.7cuft / carton<br>Carton size 620x260x175 mm (L x W x H)||||| ## 2.2. Safety/EMC |**Isolation Voltage**|I/P-O/P: 3KVac ,I/P-FG: 1.5 KVac, O/P-FG: 1.5 KVac| |---|---| |**Insulation**<br>**Resistance**|100MΩMax. / 500Vdc| |**Safety**|Design refer to UL60950-1, EN60950-1| **Ref.** IS.AC12VDC2.5ADIN **8** EN 55032:2015 EN 61000-3-2:2014 (IEC 61000-3-2:2014) **EMC** EN 61000-3-3:2013(IEC 61000-3-3:2013) EN 55024:2010+A1:2015 ## 3 **Applications and Maintenance** - 3.1. Series Operation Series Operation can be connected as shown: Load current should be less than the current value of the product with the lowest output current specified at the product specification with the Power Supply at series connection. **Ref.** IS.AC12VDC2.5ADIN **9** 3.2. Parallel Operation Do not connect the power supplies as follows: Parallel operation should be composed with the same products, while the connection shoud be as shown as “Parallel operation C”; 2. In Parallel operation C, current capacity cannot be increased, while it should be used for backup only. Moreover, diode that is to be added during parallel operation should be selected after considering it’s voltage drop, output voltage and current capacity. **Ref.** IS.AC12VDC2.5ADIN **10** 3.3. Din Rail Mounting Hang part A on the top of the Rail as shown below, then push into B direction to fix it on the DIN Rail. Remember to leave a minimum of 25mm between both PSU or between the PSU and another device located inside the cabinet. Forced air cooling makes protection against heat better. **Ref.** IS.AC12VDC2.5ADIN **11** About Industrial Shields: Direction: Fàbrica del Pont, 1-11 Zip/Postal Code: 08272 City: Sant Fruitós de Bages (Barcelona) Country: Spain Telephone: (+34) 938 760 191 / (+34) 635 693 611 Mail: industrialshields@industrialshields.com **Ref.** IS.AC12VDC2.5ADIN **12**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →