Image not available
Illustrative purposes only
IRM-30-48ST
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 30.2 W, 48 VDC, 630 mA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: IRM-30 Series
- No. of Outputs: 1Outputs
- Output Power Max: 30.2W
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 630mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 15.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
**-** 30W AC-DC PCB-Mount Green Power Module **IRM 30 series**
BauarSicherheitbeegelodwacmat geprufto ges g **LPS www.ID 2000000000tuv.com** ‘AL: **UL62368-1 EN62368-1** ~~J! S~~ **TPTC004** Hl **IEC62368-1** CBCE ■
## ■
## ℃
## Ⅱ
Ⅲ
## ■
Ⅱ
## ■
{
_File Name:IRM-30-SPEC 2019-08-30_
**- IRM 30 series**
30W AC-DC PCB-Mount Green Power Module
## **SPECIFICATION**
|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load<br>40ms/230VAC 12ms/115VAC at full load<br>47 ~ 440Hz<br>8 %<br>8<br>8 %<br>3<br>88%<br>12.6 ~ 16.2V<br>88.5%<br>15.75 ~ 20.25V<br>90%<br>25.2 ~ 32.4V<br>50.4 ~ 64V<br>0.75A/115VAC 0.5A/230VAC 0.375A/277VAC<br>COLD START 2 A/115VAC 4 A/230VAC<br>5<br>5<br>105% ~ 160% rated output power<br>5.25 ~ 6.75V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>593.3<br>℃<br>Khrs min. MIL-HDBK-217F (25<br>)<br>PCB mounting style : 69.5*39*24mm (L*W*H) Screw terminal style : 91*39.5*28.5mm (L*W*H)<br>PCB mounting style : 0.094Kg;144pcs/14.5Kg/0.97CUFT<br>Screw terminal style :0.113Kg;120pcs/14.6Kg/0.74CUFT<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>120mVp-p<br>150mVp-p<br>200mVp-p<br>240mVp-p<br>300mVp-p<br>12V<br>15V<br>24V<br>48V<br>6A<br>2.5A<br>2A<br>1.3A<br>0.63A<br>0 ~ 6A<br>0 ~ 2.5A<br>0 ~ 2A<br>0 ~ 1.3A<br>0 ~ 0.63A<br>30W<br>30W<br>30W<br>31.2W<br>30.2W<br>**IRM-30-5**<br>**IRM-30-12**<br>**IRM-30-15**<br>**IRM-30-24**<br>**IRM-30-48**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**PROTECTION**<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>5V<br>**LEAKAGE CURRENT**<br>< 0. 5mA/2<br>VAC<br>2<br>77<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**LEAD TEMPERATURE**<br>260 5<br>,5s (max.)<br>± ℃<br>**OVER VOLTAGE GATEGORY** Ⅲ; According to EN62368-1;altitude up to 2000 meters<br>**OPERATING ALTITUDE Note.4** 2000 meters<br>IEC62368-1, UL62368-1, TUV EN62368-1,<br>,<br>-1 approved; Design refer to EN60335-1 (By request)<br>EAC TP TC 004 BSMI CNS14336<br>EN55035, EN61000-6-2<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current (Note 5)<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32), CNS13438<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32), CNS13438<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>℃<br>℃<br>℃<br>**EMC**<br>**(Note.5)**<br>85 ~ 305VAC 120 ~ 430VDC<br>~~Ce~~<br>~~rs~~<br>~~se~~<br>~~Qe~~<br>~~Rs~~<br>~~Qe~~<br>~~Ge~~<br>~~se~~<br>~~se~~<br>Ce~~ee~~<br>~~se~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC.<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load<br>40ms/230VAC 12ms/115VAC at full load<br>47 ~ 440Hz<br>8 %<br>8<br>8 %<br>3<br>88%<br>12.6 ~ 16.2V<br>88.5%<br>15.75 ~ 20.25V<br>90%<br>25.2 ~ 32.4V<br>50.4 ~ 64V<br>0.75A/115VAC 0.5A/230VAC 0.375A/277VAC<br>COLD START 2 A/115VAC 4 A/230VAC<br>5<br>5<br>105% ~ 160% rated output power<br>5.25 ~ 6.75V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>593.3<br>℃<br>Khrs min. MIL-HDBK-217F (25<br>)<br>PCB mounting style : 69.5*39*24mm (L*W*H) Screw terminal style : 91*39.5*28.5mm (L*W*H)<br>PCB mounting style : 0.094Kg;144pcs/14.5Kg/0.97CUFT<br>Screw terminal style :0.113Kg;120pcs/14.6Kg/0.74CUFT<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>120mVp-p<br>150mVp-p<br>200mVp-p<br>240mVp-p<br>300mVp-p<br>12V<br>15V<br>24V<br>48V<br>6A<br>2.5A<br>2A<br>1.3A<br>0.63A<br>0 ~ 6A<br>0 ~ 2.5A<br>0 ~ 2A<br>0 ~ 1.3A<br>0 ~ 0.63A<br>30W<br>30W<br>30W<br>31.2W<br>30.2W<br>**IRM-30-5**<br>**IRM-30-12**<br>**IRM-30-15**<br>**IRM-30-24**<br>**IRM-30-48**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**PROTECTION**<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>5V<br>**LEAKAGE CURRENT**<br>< 0. 5mA/2<br>VAC<br>2<br>77<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**LEAD TEMPERATURE**<br>260 5<br>,5s (max.)<br>± ℃<br>**OVER VOLTAGE GATEGORY** Ⅲ; According to EN62368-1;altitude up to 2000 meters<br>**OPERATING ALTITUDE Note.4** 2000 meters<br>IEC62368-1, UL62368-1, TUV EN62368-1,<br>,<br>-1 approved; Design refer to EN60335-1 (By request)<br>EAC TP TC 004 BSMI CNS14336<br>EN55035, EN61000-6-2<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current (Note 5)<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32), CNS13438<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32), CNS13438<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>℃<br>℃<br>℃<br>**EMC**<br>**(Note.5)**<br>85 ~ 305VAC 120 ~ 430VDC<br>~~Ce~~<br>~~rs~~<br>~~se~~<br>~~Qe~~<br>~~Rs~~<br>~~Qe~~<br>~~Ge~~<br>~~se~~<br>~~se~~<br>Ce~~ee~~<br>~~se~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC.<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**IRM-30-5**|**IRM-30-12**|**IRM-30-12**|**IRM-30-15**|**IRM-30-15**|**IRM-30-24**|**IRM-30-48**|
|---|---|---|---|---|---|---|---|---|
||**DC VOLTAGE**|5V|12V||15V||24V|48V|
||**RATED CURRENT**|6A|2.5A||2A||1.3A|0.63A|
||**CURRENT RANGE**|0 ~ 6A|0 ~ 2.5A||0 ~ 2A||0 ~ 1.3A|0 ~ 0.63A|
||**RATED POWER**|30W|30W||30W||31.2W|30.2W|
||**RIPPLE & NOISE (max.) Note.2**|120mVp-p|150mVp-p||200mVp-p||240mVp-p|300mVp-p|
||**VOLTAGE TOLERANCE Note.3**|±2.5%|±2.5%||±2.5%||±2.5%|±2.5%|
||**LINE REGULATION**|±0.5%|±0.5%||±0.5%||±0.5%|±0.5%|
||**LOAD REGULATION**|±1.0%|±0.5%||±0.5%||±0.5%|±0.5%|
||**SETUP, RISE TIME**|1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load|||||||
||**HOLD UP TIME (Typ.)**|40ms/230VAC 12ms/115VAC at full load|||||||
||**VOLTAGE RANGE**|85 ~ 305VAC 120 ~ 430VDC|||||||
||**FREQUENCY RANGE**|47 ~ 440Hz|||||||
||**EFFICIENCY (Typ.)**|8 %<br>3|8 %<br>8||88%||88.5%|90%|
||**AC CURRENT (Typ.)**|0.75A/115VAC 0.5A/230VAC 0.375A/277VAC|||||||
||**INRUSH CURRENT (Typ.)**|COLD START 2 A/115VAC 4 A/230VAC<br>5<br>5|||||||
||**LEAKAGE CURRENT**|< 0. 5mA/2<br>VAC<br>2<br>77|||||||
||**OVERLOAD**|105% ~ 160% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||||
||**OVER VOLTAGE**|12.6 ~ 16.2V<br>15.75 ~ 20.25V<br>25.2 ~ 32.4V<br>50.4 ~ 64V<br>5.25 ~ 6.75V<br>Protection type : Shut off o/p voltage, clamping by zener diode|||||||
||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃|||||||
||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||||
||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃|||||||
||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||||
||**VIBRATION**|Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes|||||||
||**LEAD TEMPERATURE**|260 5<br>,5s (max.)<br>± ℃|||||||
||**OVER VOLTAGE GATEGORY**|Ⅲ; According to EN62368-1;altitude up to 2000 meters|||||||
||**SAFETY STANDARDS**<br>**OPERATING ALTITUDE Note.4**|2000 meters<br>IEC62368-1, UL62368-1, TUV EN62368-1,<br>,<br>-1 approved; Design refer to EN60335-1 (By request)<br>EAC TP TC 004 BSMI CNS14336|||||||
||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC|||||||
||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~Ce~~<br>~~rs~~<br>~~se~~<br>~~Qe~~<br>~~Rs~~<br>~~Qe~~<br>~~Ge~~<br>~~se~~<br>~~se~~<br>Ce~~ee~~<br>~~se~~|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||||
|||**Parameter**||**Standard**||**Test Level / Note**|||
|||Conducted<br>~~Ce~~||EN55032(CISPR32), CNS13438<br>~~Ce~~||Class B<br>~~Ce~~|||
|||Radiated<br>~~Ce~~<br>~~rs~~||EN55032(CISPR32), CNS13438<br>~~Ce~~<br>~~rs~~||Class B<br>~~Ce~~<br>~~rs~~|||
|||Harmonic Current (Note 5)<br>~~se~~||EN61000-3-2<br>~~se~~||Class A<br>~~se~~|||
|||Voltage Flicker<br>~~Qe~~||EN61000-3-3<br>~~Qe~~||-------<br>~~Qe~~|||
|||EN55035, EN61000-6-2<br>~~Qe~~<br>~~Rs~~|||||||
|||**Parameter**<br>~~Qe~~||**Standard**<br>~~Qe~~||**Test Level /Note**<br>~~Qe~~|||
|||ESD<br>~~Ge~~||EN61000-4-2<br>~~Ge~~||Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>~~Ge~~|||
|||Radiated Susceptibility<br>~~Ge~~<br>~~se~~||EN61000-4-3<br>~~Ge~~<br>~~se~~||Level 3, criteria A<br>~~Ge~~<br>~~se~~|||
|||EFT/Burest<br>~~se~~<br>Ce||EN61000-4-4<br>~~se~~<br>||Level 3, criteria A<br>~~se~~<br>|||
|||Surge<br>Ce||EN61000-4-5<br>||Level 4,2KV/L-N, criteria A<br>|||
|||Conducted<br>Ce~~ee~~||EN61000-4-6<br>~~ee~~||Level 3, criteria A<br>~~ee~~|||
|||Magnetic Field<br>~~se~~||EN61000-4-8<br>~~se~~||Level 4, criteria A<br>~~se~~|||
|||Voltage Dips and interruptions||EN61000-4-11||><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>>|||
||**MTBF**|593.3<br>℃<br>Khrs min. MIL-HDBK-217F (25<br>)|||||||
||**DIMENSION**|PCB mounting style : 69.5*39*24mm (L*W*H) Screw terminal style : 91*39.5*28.5mm (L*W*H)|||||||
||**PACKING**|PCB mounting style : 0.094Kg;144pcs/14.5Kg/0.97CUFT<br>Screw terminal style :0.113Kg;120pcs/14.6Kg/0.74CUFT|||||||
||℃<br>℃<br>℃<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC.<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)||||||||
_File Name:IRM-30-SPEC 2019-08-30_
**- IRM 30 series**
30W AC-DC PCB-Mount Green Power Module
## **Block Diagram**
**==> picture [469 x 346] intentionally omitted <==**
**----- Start of picture text -----**<br>
fosc : 65KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>PWM<br>CONTROL DETECTION<br>CIRCUIT<br>Derating Curve<br>100VAC & 230VAC<br>100 for others<br>80<br>230VAC for 5V<br>60<br>100VAC for 5V<br>50<br>40<br>20<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br>
**==> picture [152 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output Derating VS Input Voltage<br>**----- End of picture text -----**<br>
**==> picture [215 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>90<br>80<br>70<br>60<br>50<br>40<br>85 95 100 115 120 140 160 180 200 220 240 264 305<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br>
_File Name:IRM-30-SPEC 2019-08-30_
**- IRM 30 series**
## 30W AC-DC PCB-Mount Green Power Module
**==> picture [481 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mechanical Specification Case No. Unit:mm<br>� PCB mounting style<br>(IRM-30)<br>69.5<br>4 61.5 24<br>-V AC/L 3.5±1mm<br>AC/N<br>+V<br>BOTTOM<br>VIEW<br>P/N diameter:1.04<br>39<br>4.5 4.5<br>5.5<br>9<br>1.04<br>**----- End of picture text -----**<br>
**==> picture [366 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
� Screw terminal style<br>(IRM-30-xxST)<br>39.5 28.5<br>23 6.4<br>4-ψ3.4 AC/L AC/N<br>+V -V<br>5<br>80 91<br>**----- End of picture text -----**<br>
## **Installation Manual**
Please refer to : http://www.meanwell.com/manual.html
_File Name:IRM-30-SPEC 2019-08-30_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →