IRM-20-12
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 20 W, 12 VDC, 1.8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Depth: 52.4mm
- Width: 27.2mm
- Height: 24mm
- Product Range: IRM-20 Series
- No. of Outputs: 1 Output
- Output Power Max: 20W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.8A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 10.88 € |
| Current stock | 200+ |
| Lead time | 30 days |
**-** 20W AC-DC PCB-Mount Green Power Module **IRM 20 series** **==> picture [239 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>LPS www.ID 2000000000tuv.com<br>‘AL: UL62368-1 EN62368-1 J! S TPTC004 Hl IEC62368-1 CBCE<br>■<br>**----- End of picture text -----**<br> ## ■ ℃ ## Ⅱ ## ■ Ⅱ ## ■ _File Name:IRM-20-SPEC 2020-08-21_ **- IRM 20 series** 20W AC-DC PCB-Mount Green Power Module ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**PROTECTION**<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**LEAKAGE CURRENT**<br>< 0.25mA/277VAC<br>**SETUP, RISE TIME**<br>**LEAD TEMPERATURE**<br>260 5<br>,5s (max.)<br>± ℃<br>**OPERATING ALTITUDE Note.4** 2000 meters<br>IEC62368-1, UL62368-1, TUV EN62368-1, EAC TP TC 004,<br>-1 approved<br>BSMI CNS14336<br>EN55035, EN61000-6-2<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current (Note 5)<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32), CNS13438<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 3,1KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32), CNS13438<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>℃<br>℃<br>℃<br>**EMC**<br>**(Note.5)**<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load<br>47 ~ 440Hz<br>970.3Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>52.4*27.2*24mm (L*W*H)<br>0.05Kg/240pcs/13Kg/0.94CUFT<br>40ms/230VAC 8ms/115VAC at full load<br>85 ~ 305VAC 120 ~ 430VDC<br>79%<br>76%<br>84%<br>13.8 ~ 16.2V<br>84%<br>17.25 ~ 20.25V<br>85%<br>27.6 ~ 32.4V<br>0.6A/115VAC 0.4A/230VAC 0.3A/277VAC<br>COLD START 20A/115VAC 40A/230VAC<br>115%~160% rated output power<br>5.75 ~ 6.75V<br>3.8 ~ 4.46V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>±1%<br>±1%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>200mVp-p<br>200mVp-p<br>200mVp-p<br>200mVp-p<br>200mVp-p<br>3.3V<br>12V<br>15V<br>24V<br>4A<br>4.5A<br>1.8A<br>1.4A<br>0.9A<br>0 ~ 4A<br>0 ~ 4.5A<br>0 ~ 1.8A<br>0 ~ 1.4A<br>0 ~ 0.9A<br>20W<br>14.85W<br>21.6W<br>21W<br>21.6W<br>**IRM-20-5**<br>**IRM-20-12**<br>**IRM-20-15**<br>**IRM-20-24**<br>**IRM-20-3.3**<br>5V<br>~~Qe~~<br>~~rs~~<br>~~se~~<br>~~Qe~~<br>~~Rs~~<br>~~se~~<br>~~Qe~~<br>~~se~~<br>~~se~~<br>~~Ge~~<br>~~es~~<br>~~sr~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC.<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**PROTECTION**<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**LEAKAGE CURRENT**<br>< 0.25mA/277VAC<br>**SETUP, RISE TIME**<br>**LEAD TEMPERATURE**<br>260 5<br>,5s (max.)<br>± ℃<br>**OPERATING ALTITUDE Note.4** 2000 meters<br>IEC62368-1, UL62368-1, TUV EN62368-1, EAC TP TC 004,<br>-1 approved<br>BSMI CNS14336<br>EN55035, EN61000-6-2<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current (Note 5)<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32), CNS13438<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 3,1KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32), CNS13438<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>℃<br>℃<br>℃<br>**EMC**<br>**(Note.5)**<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load<br>47 ~ 440Hz<br>970.3Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>52.4*27.2*24mm (L*W*H)<br>0.05Kg/240pcs/13Kg/0.94CUFT<br>40ms/230VAC 8ms/115VAC at full load<br>85 ~ 305VAC 120 ~ 430VDC<br>79%<br>76%<br>84%<br>13.8 ~ 16.2V<br>84%<br>17.25 ~ 20.25V<br>85%<br>27.6 ~ 32.4V<br>0.6A/115VAC 0.4A/230VAC 0.3A/277VAC<br>COLD START 20A/115VAC 40A/230VAC<br>115%~160% rated output power<br>5.75 ~ 6.75V<br>3.8 ~ 4.46V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>±1%<br>±1%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>200mVp-p<br>200mVp-p<br>200mVp-p<br>200mVp-p<br>200mVp-p<br>3.3V<br>12V<br>15V<br>24V<br>4A<br>4.5A<br>1.8A<br>1.4A<br>0.9A<br>0 ~ 4A<br>0 ~ 4.5A<br>0 ~ 1.8A<br>0 ~ 1.4A<br>0 ~ 0.9A<br>20W<br>14.85W<br>21.6W<br>21W<br>21.6W<br>**IRM-20-5**<br>**IRM-20-12**<br>**IRM-20-15**<br>**IRM-20-24**<br>**IRM-20-3.3**<br>5V<br>~~Qe~~<br>~~rs~~<br>~~se~~<br>~~Qe~~<br>~~Rs~~<br>~~se~~<br>~~Qe~~<br>~~se~~<br>~~se~~<br>~~Ge~~<br>~~es~~<br>~~sr~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC.<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**IRM-20-3.3**|**IRM-20-5**|**IRM-20-5**|**IRM-20-12**|**IRM-20-12**|**IRM-20-15**|**IRM-20-24**| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|3.3V|5V||12V||15V|24V| ||**RATED CURRENT**|4.5A|4A||1.8A||1.4A|0.9A| ||**CURRENT RANGE**|0 ~ 4.5A|0 ~ 4A||0 ~ 1.8A||0 ~ 1.4A|0 ~ 0.9A| ||**RATED POWER**|14.85W|20W||21.6W||21W|21.6W| ||**RIPPLE & NOISE (max.) Note.2**|200mVp-p|200mVp-p||200mVp-p||200mVp-p|200mVp-p| ||**VOLTAGE TOLERANCE Note.3**|±2.5%|±2.5%||±2.5%||±2.5%|±2.5%| ||**LINE REGULATION**|±0.5%|±0.5%||±0.3%||±0.3%|±0.3%| ||**LOAD REGULATION**|±1%|±1%||±0.5%||±0.5%|±0.5%| ||**SETUP, RISE TIME**|1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load||||||| ||**HOLD UP TIME (Typ.)**|40ms/230VAC 8ms/115VAC at full load||||||| ||**VOLTAGE RANGE**|85 ~ 305VAC 120 ~ 430VDC||||||| ||**FREQUENCY RANGE**|47 ~ 440Hz||||||| ||**EFFICIENCY (Typ.)**|76%|79%||84%||84%|85%| ||**AC CURRENT (Typ.)**|0.6A/115VAC 0.4A/230VAC 0.3A/277VAC||||||| ||**INRUSH CURRENT (Typ.)**|COLD START 20A/115VAC 40A/230VAC||||||| ||**LEAKAGE CURRENT**|< 0.25mA/277VAC||||||| ||**OVERLOAD**|115%~160% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||||| ||**OVER VOLTAGE**|Protection type : Shut off o/p voltage, clamping by zener diode<br>13.8 ~ 16.2V<br>17.25 ~ 20.25V<br>27.6 ~ 32.4V<br>5.75 ~ 6.75V<br>3.8 ~ 4.46V||||||| ||**WORKING TEMP.**|-30 ~ +70℃(Refer to "Derating Curve")||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)||||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes||||||| ||**LEAD TEMPERATURE**|260 5<br>,5s (max.)<br>± ℃||||||| ||**OPERATING ALTITUDE Note.4**|2000 meters||||||| ||**SAFETY STANDARDS**|IEC62368-1, UL62368-1, TUV EN62368-1, EAC TP TC 004,<br>-1 approved<br>BSMI CNS14336||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC||||||| ||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~Qe~~<br>~~rs~~<br>~~se~~<br>~~Qe~~<br>~~Rs~~<br>~~se~~<br>~~Qe~~<br>~~se~~<br>~~se~~<br>~~Ge~~<br>~~es~~<br>~~sr~~|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||| |||**Parameter**||**Standard**||**Test Level / Note**||| |||Conducted<br>~~Qe~~||EN55032(CISPR32), CNS13438<br>~~Qe~~||Class B<br>~~Qe~~||| |||Radiated<br>~~Qe~~<br>~~rs~~||EN55032(CISPR32), CNS13438<br>~~Qe~~<br>~~rs~~||Class B<br>~~Qe~~<br>~~rs~~||| |||Harmonic Current (Note 5)<br>~~se~~||EN61000-3-2<br>~~se~~||Class A<br>~~se~~||| |||Voltage Flicker<br>~~Qe~~||EN61000-3-3<br>~~Qe~~||-------<br>~~Qe~~||| |||EN55035, EN61000-6-2<br>~~Qe~~<br>~~Rs~~||||||| |||**Parameter**<br>~~se~~||**Standard**<br>~~se~~||**Test Level /Note**<br>~~se~~||| |||ESD<br>~~Qe~~||EN61000-4-2<br>~~Qe~~||Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>~~Qe~~||| |||Radiated Susceptibility<br>~~Qe~~<br>~~se~~||EN61000-4-3<br>~~Qe~~<br>~~se~~||Level 3, criteria A<br>~~Qe~~<br>~~se~~||| |||EFT/Burest<br>~~se~~||EN61000-4-4<br>~~se~~||Level 3, criteria A<br>~~se~~||| |||Surge<br>~~Ge~~||EN61000-4-5<br>~~Ge~~||Level 3,1KV/L-N, criteria A<br>~~Ge~~||| |||Conducted<br>~~Ge~~<br>~~es~~||EN61000-4-6<br>~~Ge~~<br>~~es~~||Level 3, criteria A<br>~~Ge~~<br>~~es~~||| |||Magnetic Field<br>~~sr~~||EN61000-4-8<br>~~sr~~||Level 4, criteria A<br>~~sr~~||| |||Voltage Dips and interruptions||EN61000-4-11||><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>>||| ||**MTBF**|970.3Khrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| ||**DIMENSION**|52.4*27.2*24mm (L*W*H)||||||| ||**PACKING**|0.05Kg/240pcs/13Kg/0.94CUFT||||||| ||℃<br>℃<br>℃<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC.<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|||||||| _File Name:IRM-20-SPEC 2020-08-21_ **- IRM 20 series** ## 20W AC-DC PCB-Mount Green Power Module **==> picture [481 x 620] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 65KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>PWM<br>CONTROL DETECTION<br>CIRCUIT<br>Derating Curve Output Derating VS Input Voltage<br>OTHERS 100<br>100<br>90<br>80<br>80<br>3.3V,5V<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) 85 95 100 115 120 140 160 180 200 220 240 305<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>Mechanical Specification<br>Case No.219A Unit:(mm)<br>52.4<br>3.4 45 24<br>AC/N -V<br>3.5±1mm<br>+V<br>BOTTOM<br>VIEW<br>AC/L<br>P/N diameter:1.04<br>Installation Manual<br>LOAD (%) LOAD (%)<br>3.2<br>20.8<br>1.04<br>27.2<br>3.2<br>8<br>**----- End of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html _File Name:IRM-20-SPEC 2020-08-21_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →