Image not available
Illustrative purposes only
IELR1-1-63-2.50-91-V
MAGNETIC HYDRAULIC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA / PARTNER STOCK
- Product type: Magnetic Hydraulic Circuit Breakers
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 126.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **| IAL/CEL/LEL SERIES** HYDRAULIC MAGNETIC CIRCUIT PROTECTORS ## Introduction Designed specifically for the 35mm symmetrical DIN rail, Airpax IALHR, IULHR and IELHR series Rail-Mount Magnetic circuit protectors offer the advantages of quick and easy mounting or removal which results in efficient and economical wiring, while conserving space. These circuit protectors are available in 1, 2, 3 and 4 pole models, with a choice of handle colors with on/off and international I/O markings. These protectors comply with UL and CSA standards and meet IEC and VDE spacing requirements. Typical applications include computers and peripherals, telecommunications, medical equipment, machine tools and process control instrumentation. They provide the reliable performance associated with ## magnetic circuit protection. Mounting - These circuit protectors are designed to mount on standard 35mm DIN rails, such as 35x7.5 or 35x15 per DIN EN50022. Other specialty rails are available from suppliers that provide a means of mounting non DIN mount components by means of special captive jam nuts. ## **SINGLE POLE, STANDARD STUD TERMINAL** Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. Page 1 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com Two Pole **==> picture [542 x 333] intentionally omitted <==** **----- Start of picture text -----**<br> .236 1.929 .138<br>[5.99] [49.00] [3.51]<br>DIM.ìAî<br>.689 .183<br>.689 [17.50] [4.65]<br>[17.50]<br>1.680<br>[42.67] 1.122 ON II ON<br>[28.50]<br>1.437<br>[36.50]<br>1.417<br>[35.99] 2.059<br>2.500 OFFO OFFO [52.30]<br>3.622 [63.50]<br>[92.00]<br>4 X 6-32 THREAD<br>M3 X 0.5-6H THREAD OPTIONAL<br>ALL MULTI-POLE CONFIGURATIONS 1.240 .748<br>USE TWO MOUNTING CLIPS [31.50] .142 [3.6] DEEP (TYP.) [19.00]<br>MULTI-POLE DIMENSIONS - DIM “A”<br>1 pole .750 ± .02 [19.05 ± .5] max<br>2 pole 1.515 [38.48] max<br>3 pole 2.265 [57.53] max<br>4 pole 3.015 [76.58] max<br>**----- End of picture text -----**<br> Note: Dimension “A” varies with # of poles ## **SPECIFICATIONS** ## **Series Trip** The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indicates circuit status. In addition to providing conventional overcurrent protection, it’s simultaneously used as an on-off switch. ## **Switch Only** In the event that over-current protection is not desired, the coil mechanism can be deleted, providing an excellent low cost, single or multi-pole power switch. ## **Insulation Resistance** **==> picture [106 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> Series<br>LINE<br>LOAD<br>**----- End of picture text -----**<br> 100 megohm minimum at 500Vdc between all electrically isolated terminals. **Dielectric Strength** 3750Vac (3750V~) shall withstand AC voltages 50/60Hz for 60 seconds between all electrically isolated terminals. ## **Endurance** Circuit breakers shall operate a minimum of 10,000 operations; 6,000 with rated current and voltage and 4,000 with no load. Switch Only ## **Operating Temperature** –40°C to +85°C. **IEC 144 Classification** Type handle spacings–IP40. Terminals–IP00. Page 2 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com Three Pole Schematic Diagram ## **Moisture Resistance** 10 days, 95 percent relative humidity at 40°C in accordance with IEC68-2-3, test C. ## **Salt Spray** Five percent solution at 35°C in accordance with IEC68-2-11, test K, 48 hours. ## **Shock** 50g, 11m sec, half sine with rated current, except no current with handle down. Instantaneous units use 80 percent rated current. Test in accordance with IEC68-2-27, test Ea. This assumes that adequate end stops are used to prevent longitudinal movement of the circuit protector. ## **Vibration** 4g, 5–500Hz (maximum double amplitude displacement 1.5mm) with rated current except no current with handle down. Instantaneous units use 80 percent rated current, in accordance with IEC68-2-6, test F, method A, one hour per plane. This assumes that adequate end stops will be used to prevent longitudinal movement of the circuit protector. **t= f (I)** **==> picture [104 x 137] intentionally omitted <==** ## **OPERATING CHARACTERISTICS** ||**NOMINAL DCR /IMPEDANCE**|**NOMINAL DCR /IMPEDANCE**|**NOMINAL DCR /IMPEDANCE**| |---|---|---|---| |Current Ratings<br>(Amps)|Resistance (ohms)|Impedance (ohms)|Impedance (ohms)| ||DC Delays|AC, 50/60Hz Delays|AC, 400Hz Delays| ||51, 52, 53, 59|61, 62, 63, 69|41, 42, 43, 49| |0.20|45.8|28.5|71.94| |1.0|1.38|1.10|2.85| |2.0|0.371|0.29|0.76| |5.0|0.055|0.051|0.12| |10.0|0.017|0.016|0.032| |20.0|0.006|0.006|0.010| |30.0|0.003|0.004|0.006| |50.0|0.0019|0.0018|0.0019| |60.0|0.00157|0.00134|-| |70.0|0.00147|0.00133|-| Notes: DCR and impedance based on 100% rated current applied and stabilized for a minimum of one hour. Tolerance .05-2.5 amperes ± 20%; 2.6-20 amperes ± 25%; 21-70 amperes ± 50%. Consult factory for special values and for coil impedance of delays not shown. ## **Inrush Pulse Tolerance** Pulse tolerance is defined as a single pulse of half sine wave 50/60Hz peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. **==> picture [437 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Delay Pulse Tolerance<br>**----- End of picture text -----**<br> |**Delay**|**Pulse Tolerance**| |---|---| ||| |61, 62, 63 (.1 to 70 amps)|12 times (approx.) rated current| |61F, 62F, 63F (.1 to 25 amps)|20 times (approx.) rated current| |61F, 62F, 63F (25.1 to 70 amps)|18 times (approx.) rated current| Page 3 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com |**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**| |---|---|---|---|---|---|---|---|---| |Delay|100%|125%*|150%|200%|400%|600%|800%|1000%| |41|No Trip|May trip|.5 to 8|.15 to 1.9|.02 to .4|.006 to .25|.004 to .1|.004 to .05| |42|No Trip|May trip|5 to 70|2.2 to 25|.40 to 5|.012 to 2|.006 to .2|.006 to .15| |43|No Trip|May trip|35 to 350|12 to 120|1.5 to 20|.012 to 2.2|.01 to .22|.01 to .1| |49|No Trip|May trip|.100 max.|.050 max.|.020 max.|.020 max.|.020 max|.020 max.| |51|No Trip|.5 to 6.5|.3 to 3|.1 to 1.2|.031 to .5|.011 to .25|.004 to .1|.004 to .08| |52|No Trip|2 to 60|1.8 to 30|1 to 10|.15 to 2|.04 to 1|.008 to .5|.006 to .1| |53|No Trip|80 to 700|40 to 400|15 to 150|2 to 20|.23 to 9|.015 to .55|.012 to .2| |59|No Trip|.120 max.|.100 max.|.050 max.|.022 max.|.017 max|.017 max.|.017 max.| |61|No Trip|.7 to 12|.35 to 7|.130 to 3|.030 to 1|.015 to .3|.01 to .15|.008 to .1| |62|No Trip|10 to 120|6 to 60|2 to 20|.2 to 3|.02 to 2|.015 to .8|.01 to .25| |63|No Trip|50 to 700|30 to 400|10 to 150|1.5 to 20|.4 to 10|.013 to .85|.013 to .5| |69|No Trip|.120 max|.100 max.|.050 max.|.022 max.|.017 max.|.017 max.|.017 max| |71|No Trip|.44 to 10|.3 to 7|.100 to 3|.030 to 1|.012 to .3|.004 to .15|.004 to .1| |72|No Trip|1.8 to 100|1.7 to 60|1 to 20|.15 to 3|.015 to 2|.008 to .79|.006 to .28| |73|No Trip|50 to 600|30 to 400|10 to 150|1.8 to 20|.015 to 10|.015 to .88|.011 to .5| |79|No Trip|.120 max|.100 max.|.050 max.|.023 max.|.016 max.|.015 max.|.015 max| Notes: All trip curves and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of +25° C. Protectors do not carry current prior to application of overload. A: Ratings above 30 amps may deviate from the above limits by approximately 10% (130% for delay 49). * No 53 delay on 125 amp single pole or 400 amp four pole devices * 135% for delay 71, 72, 73 & 79 ## **DELAY CURVES** ## 400Hz, DC, 50/60Hz Delay Curves (typ) A choice of delays is offered for DC, 50/60Hz, 400Hz, or combined DC/50/60Hz applications. Delays 49, 59, 69 and 79 provide fast acting, instantaneous tripping and are often used to protect sensitive electronic equipment (not recommended where a known inrush exists). Delays 41, 51, 61 and 71 have a short delay for general purpose applications. Delays 42, 52, 62 and 72 are long enough for most transformers and capacitor loads. Delays 43, 53, 63 and 73 are extra long for special motor applications. ## **50/60Hz Delay Curves (typ)** **==> picture [205 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 61<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>TIME IN SECONDS MAY TRIP<br>**----- End of picture text -----**<br> **==> picture [205 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 63<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> Page 4 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com **==> picture [205 x 557] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 62<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>DC Delay Curves (typ)<br>10000<br>1000 DELAY 51<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 52<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [206 x 558] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 69<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 53<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 59<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> Page 5 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com **DC/50/60Hz Delay Curves (typ) (Multi-Frequency)** **==> picture [205 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>DELAY 71<br>1000 DC/50/60 Hz<br>Short Delay<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>135<br>PERCENT OF RATED CURRENT<br>10000<br>DELAY 72<br>1000 DC/50/60 Hz<br>Long Delay<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>135<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [205 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>DELAY 73<br>1000 DC/50/60 Hz<br>Motor Start Delay<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>135<br>PERCENT OF RATED CURRENT<br>10000<br>DELAY 79<br>1000 DC/50/50 Hz<br>135% Instant Trip<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 7008 00 9001 000<br>135<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> Page 6 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com ## **400Hz Delay Curves (typ)** **==> picture [205 x 358] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 41<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 42<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [205 x 358] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 43<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 150200 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 49<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>01 00 1502 00 3004 00 5006 00 700 800 9001 000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> ## **ORDERING OPTIONS** ## Example: IEL1-1REC4-61-20.0-01-V The ordering code for IELR circuit protectors may be determined by following the steps in the decision tables shown here. The coding given permits a self-assigning part number, but with limitations. Using the illustrated coding system, it will automatically be assumed that all poles are identical. When all poles of a multi-pole protector are not identical, please contact an Airpax sales representative or the factory for a part number. One great virtue of magnetic circuit protectors is their adaptability to complex circuits. Thus, variations from pole to pole can become the rule rather than the exception. Descriptive drawings are recommended to avoid confusion. When specifying a protector for AC motor start or high inrush applications, it is helpful to know the peak amplitude and surge duration for proper protector selection. Notes: When poles are not identical, each pole is to be described and a special Airpax number will be assigned. Thomas & Betts (T&B) Narrow Tongue Lug P/N 54108NT is recommended for units rated above 50A. The T&B lug or an equivalent must be used on units rated 70A and above. Page 7 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com **1REC4** **IEL** **V** **61** **20.0** **01** **1** **-** **-** **-** **-** **-** ## **Type** **IALHR:** One handle per pole (multi-pole only) **IULHR:** One handle per pole(multi-pole only)UL Recognized, CSA Certiedand VDE Approved ratings **IELHR:** One handle per pole(multi-pole only) UL Recognized, CSA Certiedand VDE Approved ratings **IALR:** One handle per unit **IULR:** One handle per unitUL Recognizedand CSA Certied ratings **IELR:** One handle per unitUL Recognized, CSA Certiedand VDE Approved ratings **IMLR:** Mid-trip indication, One handle per unit **IMLHR:** Mid-trip indication, One handle per pole ## **Poles** **1:** Single pole **11:** Two pole **111:** Three pole **1111:** Four pole ## **Internal Configuration** **-0:** Switch only (Omit 4th decision) **-1:** Series ## **Frequency & Delay** **SW:** Switch only **-41:** 400Hz short delay **-42:** 400Hz long delay **-43:** 400Hz motor start **-49:** 400Hz 150% instant trip **-51:** DC short delay **-52:** DC long delay **-53:** DC motor start **-59:** DC 125% instant trip **-61:** 50/60Hz short delay **-62:** 50/60Hz long delay **-63:** 50/60Hz motor start **-69:** 50/60Hz 125% instant trip **-71:** DC/60Hz short delay **-72:** DC/60Hz long delay **-73:** DC/60Hz motor start **-79:** DC/60 Hz 135% instant trip ## **Rated Current** Standard ratings listed. For other ratings, please contact the factory. **10.0:** .100 **15.0:** .250 **20.0:** .500 **30.0:** .750 **35.0:** 1.0 **40.0:** 2.5 **50.0:** 5.0 **60.0:** 7.5 **70.0:** 7.5 Use three numbers to print required valuebetween .050 amperes minimum and 70.0 amperes maximum. ## **Optional** Standard hardware. No designation required. **-A** : Metric thread mountinginserts **-C:** 277V (50/60Hz only) **-D:** 240/415V (50/60Hz only) ## **Handle Color and Marking Selection** **Unmarked Marked (Combination On - Off / I-O) -01:** Black **-01:** Black with white markings **-10:** Yellow **-11:** Yellow with black markings **-20:** Red **-21:** Red with white markings **-30:** Blue **-31:** Blue with white markings **-40:** Green **-41:** Green with white markings **-60:** Orange **-61:** Orange with black markings **-90:** White **-91 (Std.):** White with black markings Page 8 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com **AGENCY APPROVALS & CERTIFICATIONS** |**Voltage (Volts)**<br>~~eG~~|**Voltage (Volts)**<br>~~eG~~|**Voltage (Volts)**<br>~~eG~~|**Voltage (Volts)**<br>~~eG~~|**Rated Current (Amps)**<br>~~eG~~|**Rated Current (Amps)**<br>~~eG~~|**Interrupting Capacity, Amps**<br>~~eG~~<br>~~(O~~|**Interrupting Capacity, Amps**<br>~~eG~~<br>~~(O~~| |---|---|---|---|---|---|---|---| |**Max Voltage**<br>~~eG~~<br>~~es~~|**Frequency**<br>**(Hz)**<br>~~eG~~<br>~~Ce~~|**Phase**<br>~~eG~~<br>~~Ce~~|**Min Poles**<br>~~eG~~<br>~~GC~~|**UL/CSA**<br>~~eG~~<br>~~GC~~|**TUV**<br>~~eG~~<br>~~GC~~|**UL1077 & CSA**<br>~~eG~~<br>~~(O~~|**TUV**<br>~~eG~~<br>~~(O~~| |80<br>~~es~~<br>~~a~~|DC<br>~~Ce~~<br>~~a~~|-<br>~~Ce~~<br>~~Ge~~|1<br>~~GC~~<br>~~GG~~|.05 to 50<br>~~GC~~<br>~~GG~~|.10 - 50<br>~~GC~~<br>~~GG~~|u2, 1000|4000| |80<br>~~es~~<br>~~a~~<br>~~ee~~|DC<br>~~Ce~~<br>~~a~~<br>~~Ge~~|-<br>~~Ce~~<br>~~Ge~~<br>~~Ge~~|1<br>~~GC~~<br>~~GG~~<br>~~GG~~|.05 to 100<br>~~GC~~<br>~~GG~~<br>~~GG~~|-<br>~~GC~~<br>~~GG~~<br>~~GG~~|u2, 5000|-| |250<br>~~a~~<br>~~ee~~<br>~~a~~|50/60<br>~~a~~<br>~~Ge~~<br>~~a~~|1 & 3<br>~~Ge~~<br>~~Ge~~<br>~~Ce~~|1<br>~~GG~~<br>~~GG~~<br>~~GO~~|.05 to 50<br>~~GG~~<br>~~GG~~<br>~~GO~~|.10 - 50<br>~~GG~~<br>~~GG~~<br>~~GO~~|3500|2000| |250<br>~~ee~~<br>~~a~~<br>~~pO~~|50/60<br>~~Ge~~<br>~~a~~|1 & 3<br>~~Ge~~<br>~~Ce~~|1<br>~~GG~~<br>~~GO~~<br>~~GG~~|.05 to 70<br>~~GG~~<br>~~GO~~<br>~~GG~~|-<br>~~GG~~<br>~~GO~~<br>~~GG~~|2000|-| |250<br>~~a~~<br>~~Ce~~<br>~~pO~~|50/60<br>~~a~~<br>~~Ce~~|1 & 3<br>~~Ce~~<br>~~Ce~~|1<br>~~GO~~<br>~~Ce~~<br>~~GG~~|.05 to 50<br>~~GO~~<br>~~Ce~~<br>~~GG~~|-<br>~~GO~~<br>~~Ce~~<br>~~GG~~|5000 (1)<br>~~Ce~~|-<br>~~Ce~~| |250<br>~~pO~~<br>~~pO~~|50/60|1 & 3|1<br>~~GG~~|.05 to 70<br>~~GG~~|-<br>~~GG~~|5000 (1)|-| |277<br>~~pO~~<br>~~pO~~|50/60|1|1<br>~~GG~~|.05 to 50<br>~~GG~~|-<br>~~GG~~|2000|-| |277<br>~~pO~~<br>~~Ge~~<br>~~Ge~~|50/60<br>~~Ge~~<br>~~Ge~~|1<br>~~Ge~~<br>~~Ge~~|1<br>~~GG~~<br>~~**G**~~|.05 to 50<br>~~GG~~<br>~~**G**G~~|-<br>~~GG~~<br>~~G~~|5000 (1)|-| |240/415<br>~~Ge~~<br>~~Ge~~<br>~~Ge~~|50/60<br>~~Ge~~<br>~~Ge~~<br>~~Ge~~|1 & 3<br>~~Ge~~<br>~~Ge~~<br>~~Ge~~|2<br>~~GG~~<br>~~Ge~~<br>~~**G**~~|.05 to 50<br>~~GG~~<br>~~Ge~~<br>~~**G**G~~|.10 - 30<br>~~GG~~<br>~~Ge~~<br>~~G~~|2000<br>~~Ge~~|2000<br>~~Ge~~| |240/415<br>~~Ge~~<br>~~Ge~~<br>~~a~~|50/60<br>~~Ge~~<br>~~Ge~~<br>~~a~~|1 & 3<br>~~Ge~~<br>~~Ge~~<br>~~Ge~~|2<br>~~Ge~~<br>~~**G**~~|.05 to 50<br>~~Ge~~<br>~~**G**G~~<br>~~G~~<br>~~GG~~|-<br>~~Ge~~<br>~~G~~<br>~~G~~<br>~~GG~~|5000 (1)<br>~~Ge~~|-<br>~~Ge~~| |277/480<br>~~Ge~~<br>~~a~~<br>~~a~~|50/60<br>~~Ge~~<br>~~a~~<br>~~a~~|3<br>~~Ge~~<br>~~Ge~~<br>~~Ge~~|2<br>~~**G**~~<br>~~GG~~|.05 to 30<br>~~**G**G~~<br>~~G~~<br>~~GG~~<br>~~GG~~|-<br>~~G~~<br>~~G~~<br>~~GG~~<br>~~GG~~|2000|-| |250<br>~~a~~<br>~~a~~|400<br>~~a~~<br>~~a~~|1 & 3<br>~~Ge~~<br>~~Ge~~|1<br>~~GG~~|.05 to 50<br>~~GG~~<br>~~GG~~|-<br>~~GG~~<br>~~GG~~|1750|-| Note: (1) with 125A max series fuse. ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions can result in death or serious injury.** Page 9 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** 508-236-2551 electrical-protection-sales@ sensata.com **Europe, Middle East & Africa** +31743578156 info-sse@list.sensata.com ## **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Copyright © 2018 Sensata Technologies, Inc. Revised 7/31/18 www.sensata.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →