IDPV-65-12
LED Driver, 50.4 W, 12 VDC, 4.2 A, Constant Voltage, 180 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: IDPV-65
- Output Current: 4.2A
- LED Driver Mode: Constant Voltage
- Output Power Max: 50.4W
- Input Voltage Max: 295V
- Input Voltage Min: 180V
- Output Voltage Max: 12VDC
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 17.03 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- IDPV 65 series** 65W PWM Output LED Driver **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [99 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> S&E<br>■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ~ to the ℃ ~+40 ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [245 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> |«| A [2] [in] [1] [dimming] [and] [Auxiliary] DC [output]<br>**----- End of picture text -----**<br> _File Name:IDPV-65-SPEC 2018-01-10_ **- IDPV 65 series** 65W PWM Output LED Driver ## **SPECIFICATION** |**IDPV-65 -12**<br>**IDPV-65 -24**<br>**IDPV-65 -36**<br>**IDPV-65 -48**<br>**IDPV-65 -60**<br>**MODEL**<br>**OUTPUT**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>47 ~ 63Hz<br>105 ~ 115%<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 40<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>398.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>±10%<br>0~100%<br>85%<br>87%<br>88%<br>89%<br>90%<br><0.75mA / 277VAC<br>130*67.5*22mm (L*W*H)<br>0.15Kg;81pcs/13Kg/ 1.46CUFT<br>**SHORT CIRCUIT**<br>Shut down O/P voltage, re-power on to recovery<br>**DIMMING RANGE**<br>**DC VOLTAGE**<br>**RATED POWER**<br>**SETUP TIME Note.3**<br>**VOLTAGE TOLERANCE**<br>**VOLTAGE RANGE Note.2**<br>1KHz(<br>20%)<br>±<br>500ms / 230VAC<br>12V<br>24V<br>36V<br>48V<br>60V<br>4.2A<br>2.4A<br>1.8A<br>1.35A<br>50.4W<br>57.6W<br>64.8W<br>64.8W<br>1.08A<br>64.8W<br>**PWM FREQUENCY (Typ.)**<br>**AUXILIARY DC OUTPUT Note.4**<br>Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC 254 ~ 417VDC<br>COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>270μ<br>;Per NEMA 410<br><0.5W for Blank-Type, <1.2W for A-Type<br>**NO LOAD POWER CONSUMPTION**<br>**WORKING TEMP.**<br>Ta=-20 ~ +40<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>UL8750,CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14 approved<br>Compliance to EN55015, EN61000-3-2 Class C (<br>) ; EN61000-3-3,GB17743,GB17625.1<br>@load<br>60%<br>≧<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(<br>)<br>surge immunity:Line-Line:1KV<br>℃<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC<br>PF>0.95/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load 60%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>0.4A/230VAC 0.3A/277VAC<br>**RATED CURRENT**<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. Aux. 12V will be damaged with short circuit; It will not be available with dimming off or output no load condition.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be<br>affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.|**IDPV-65 -12**<br>**IDPV-65 -24**<br>**IDPV-65 -36**<br>**IDPV-65 -48**<br>**IDPV-65 -60**<br>**MODEL**<br>**OUTPUT**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>47 ~ 63Hz<br>105 ~ 115%<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 40<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>398.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>±10%<br>0~100%<br>85%<br>87%<br>88%<br>89%<br>90%<br><0.75mA / 277VAC<br>130*67.5*22mm (L*W*H)<br>0.15Kg;81pcs/13Kg/ 1.46CUFT<br>**SHORT CIRCUIT**<br>Shut down O/P voltage, re-power on to recovery<br>**DIMMING RANGE**<br>**DC VOLTAGE**<br>**RATED POWER**<br>**SETUP TIME Note.3**<br>**VOLTAGE TOLERANCE**<br>**VOLTAGE RANGE Note.2**<br>1KHz(<br>20%)<br>±<br>500ms / 230VAC<br>12V<br>24V<br>36V<br>48V<br>60V<br>4.2A<br>2.4A<br>1.8A<br>1.35A<br>50.4W<br>57.6W<br>64.8W<br>64.8W<br>1.08A<br>64.8W<br>**PWM FREQUENCY (Typ.)**<br>**AUXILIARY DC OUTPUT Note.4**<br>Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC 254 ~ 417VDC<br>COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>270μ<br>;Per NEMA 410<br><0.5W for Blank-Type, <1.2W for A-Type<br>**NO LOAD POWER CONSUMPTION**<br>**WORKING TEMP.**<br>Ta=-20 ~ +40<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>UL8750,CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14 approved<br>Compliance to EN55015, EN61000-3-2 Class C (<br>) ; EN61000-3-3,GB17743,GB17625.1<br>@load<br>60%<br>≧<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(<br>)<br>surge immunity:Line-Line:1KV<br>℃<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC<br>PF>0.95/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load 60%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>0.4A/230VAC 0.3A/277VAC<br>**RATED CURRENT**<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. Aux. 12V will be damaged with short circuit; It will not be available with dimming off or output no load condition.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be<br>affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.|**IDPV-65 -12**|**IDPV-65 -24**|**IDPV-65 -36**|**IDPV-65 -48**|**IDPV-65 -60**| |---|---|---|---|---|---|---| ||**DC VOLTAGE**|12V|24V|36V|48V|60V| ||**RATED CURRENT**|4.2A|2.4A|1.8A|1.35A|1.08A| ||**RATED POWER**|50.4W|57.6W|64.8W|64.8W|64.8W| ||**DIMMING RANGE**|0~100%||||| ||**VOLTAGE TOLERANCE**|±10%||||| ||**PWM FREQUENCY (Typ.)**|1KHz(<br>20%)<br>±||||| ||**SETUP TIME Note.3**|500ms / 230VAC||||| ||**AUXILIARY DC OUTPUT Note.4**|Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only||||| ||**VOLTAGE RANGE Note.2**|(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC 254 ~ 417VDC||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||| ||**POWER FACTOR (Typ.)**|PF>0.95/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load 60%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)||||| ||**EFFICIENCY (Typ.)**|85%|87%|88%|89%|90%| ||**AC CURRENT (Typ.)**|0.4A/230VAC 0.3A/277VAC||||| ||**INRUSH CURRENT(Typ.)**|COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>270μ<br>;Per NEMA 410||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC||||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC||||| ||**NO LOAD POWER CONSUMPTION**|<0.5W for Blank-Type, <1.2W for A-Type||||| ||**SHORT CIRCUIT**|Shut down O/P voltage, re-power on to recovery||||| ||**OVER CURRENT**|105 ~ 115%<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||| ||**WORKING TEMP.**|Ta=-20 ~ +40<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80<br>, 10 ~ 95% RH<br>℃||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 40<br>)||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes||||| ||**SAFETY STANDARDS**|UL8750,CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14 approved||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC||||| ||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||| ||**EMC EMISSION**|Compliance to EN55015, EN61000-3-2 Class C (<br>) ; EN61000-3-3,GB17743,GB17625.1<br>@load<br>60%<br>≧||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(<br>)<br>surge immunity:Line-Line:1KV||||| ||**MTBF**|398.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||| ||**DIMENSION**|130*67.5*22mm (L*W*H)||||| ||**PACKING**|0.15Kg;81pcs/13Kg/ 1.46CUFT||||| ||℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. Aux. 12V will be damaged with short circuit; It will not be available with dimming off or output no load condition.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be<br>affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.|||||| _File Name:IDPV-65-SPEC 2018-01-10_ **- IDPV 65 series** 65W PWM Output LED Driver ## **DIMMING OPERATION** **==> picture [162 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>ACLACLACNACN TB1 T1<br>DIM+DIM-Vo+Vo- TB2<br>-<br>FS1<br>HS2<br>HS1<br>**----- End of picture text -----**<br> - ※ **Dimming principle for PWM style output** - �Dimming is achieved by varying the duty cycle of the output current. **==> picture [436 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> ON<br>Output DC current TON<br>Duty cycle(%) = ×100%<br>T<br>OFF Output PWM frequency : 1KHz (±20%)<br>Io=0A<br>TON<br>T<br> 2 in 1 dimming function<br>Applying additive 0 ~ 10VDC 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM-DO NOT connect "DIM- to Vo-”” 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>Applying additive 10V PWM signal (frequency range 300Hz~3KHz): 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-” 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>Duty cycle of output current (%)<br>Duty cycle of output current (%)<br>**----- End of picture text -----**<br> ※ **2 in 1 dimming function** **==> picture [101 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 0 ~ 10VDC<br>**----- End of picture text -----**<br> **==> picture [224 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>Vo+ +<br>-<br>Vo- -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM-DO NOT connect "DIM- to Vo-””<br>◎ Applying additive 10V PWM signal (frequency range 300Hz~3KHz):<br>**----- End of picture text -----**<br> Note : 1. Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%. 2. The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle. 3. To ensure the dimming effect, total power must be over 45W at 100% duty cycle. _File Name:IDPV-65-SPEC 2018-01-10_ **- IDPV 65 series** 65W PWM Output LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [493 x 602] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>40<br>20<br>-20 -10 0 5 10 20 30 40 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>1.00<br>100<br>0.96<br>90<br>0.92<br>80<br>0.88 277V<br>70<br>0.84<br>60 230V<br>0.80<br>50<br>0.76<br>40<br>0.72<br>50% 60% 70% 80% 90% 100%<br>180 200 230 260 295 (65W)<br>INPUT VOLTAGE (V)<br>LOAD<br>※De-rating is needed under low input voltage.<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>IDPV-65 series possess superior working efficiency that up to 90% can<br>be reached in field applications.<br>※ 60V Model ※ 60V Model<br>18 94%<br>16 90%<br>14 86%<br>12 277VAC 82% 277V<br>10<br>8 230VAC 78% 230V<br>74%<br>6<br>70%<br>4<br>2 66%<br>0 62%<br>50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>LOAD<br>LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:IDPV-65-SPEC 2018-01-10_ **- IDPV 65 series** 65W PWM Output LED Driver **==> picture [93 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> BLOCK DIAGRAM<br>**----- End of picture text -----**<br> **==> picture [473 x 595] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 70-150KHz<br>RECTIFIERS AUX+(for A-Type)<br>AUX-(for A-Type)<br>EMI FILTER POWER RECTIFIERS Vo+<br>I/P & SWITCHING &<br>RECTIFIERS FILTER Vo-<br>CURRENT DIM+<br>LIMIT DIM-<br>O.L.P. DETECTION<br>PWM&PFC CIRCUIT<br>CONTROL<br>MECHANICAL SPECIFICATION<br>※ Blank-Type Unit:mm<br>130<br>122 4<br>+<br>ACLACLACNACN TB1 T1<br>DIM+DIM-Vo+Vo- TB2<br>Terminal Pin No. Assignment(TB1)<br>Pin No. Assignment Terminal Pin No. Assignment(TB2)<br>1 ACL Pin No. Assignment<br>2 ACL 1 DIM+<br>3 ACN 2 DIM-<br>4 ACN 3 Vo+<br>4 Vo-<br>5<br>4-ψ3.<br>-<br>FS1<br>HS2<br>HS1<br>4<br>59.5 67.5<br>22<br>3<br>**----- End of picture text -----**<br> _File Name:IDPV-65-SPEC 2018-01-10_ **- IDPV 65 series** 65W PWM Output LED Driver ## ※ **A-Type** **==> picture [422 x 307] intentionally omitted <==** **----- Start of picture text -----**<br> 130<br>122 4<br>+<br>ACLACLACNACN TB1 T1<br>DIM+DIM-Vo+Vo-AUX+AUX- TB2<br>Terminal Pin No. Assignment(TB1)<br>Pin No. Assignment<br>Terminal Pin No. Assignment(TB2)<br>1 ACL<br>Pin No. Assignment Pin No. Assignment<br>2 ACL<br>1 DIM+ 4 Vo-<br>3 ACN<br>2 DIM- 5 AUX+<br>4 ACN<br>3 Vo+ 6 AUX-<br>5<br>4-ψ3.<br>-<br>FS1<br>HS2<br>HS1<br>4<br>59.5 67.5<br>22<br>3<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:IDPV-65-SPEC 2018-01-10_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →