Image not available
Illustrative purposes only
IDLV-65A-60
LED Driver, 64.8 W, 60 VDC, 1.08 A, Constant Voltage, 180 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: IDLV-65
- Output Current: 1.08A
- LED Driver Mode: Constant Voltage
- Output Power Max: 64.8W
- Input Voltage Max: 295V
- Input Voltage Min: 180V
- Output Voltage Max: 60VDC
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 10.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
> **-** > 65W PWM Output LED Driver **IDLV 65 series** wt **IS 15885(Part 2/Sec13)** ~~9~~ TV ** ** ~~E~~ ® ** R-41027766** THOMAS SAMUEL THOMAS SAMUEL C BCE (for IDLV-65-12,24,48 only) ■ **** ■ **** ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ■ **** ~ ℃℃ ■ **** > **** O **** [E A _File Name:IDLV-65-SPEC 2019-07-25_ **- IDLV 65 series** 65W PWM Output LED Driver ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|||||| |---|---|---|---|---|---|---| |**IDLV-65 -12**<br>**IDLV-65 -24**<br>**IDLV-65 -36**<br>**IDLV-65 -48**<br>**IDLV-65 -60**<br>**MODEL**<br>**OUTPUT**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>47 ~ 63Hz<br>105 ~ 115%<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 40℃)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>398.7K hrs min. MIL-HDBK-217F (25℃)<br>±10%<br>0~100%<br>85%<br>87%<br>88%<br>89%<br>90%<br><0.75mA / 277VAC<br>130*75*25mm (L*W*H)<br>0.23Kg;54pcs/13.5Kg/ 0.96CUFT<br>**SHORT CIRCUIT**<br>Shut down O/P voltage, re-power on to recovery<br>**DIMMING RANGE**<br>**DC VOLTAGE**<br>**RATED POWER**<br>**SETUP TIMENote.3**<br>**VOLTAGE TOLERANCE**<br>**VOLTAGE RANGENote.2**<br>1KHz(±20%)<br>500ms / 230VAC<br>12V<br>24V<br>36V<br>48V<br>60V<br>4.2A<br>2.4A<br>1.8A<br>1.35A<br>50.4W<br>57.6W<br>64.8W<br>64.8W<br>1.08A<br>64.8W<br>**PWM FREQUENCY (Typ.)**<br>**AUXILIARY DC OUTPUTNote.4**<br>Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC 254 ~ 417VDC<br>COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>270μ<br>;Per NEMA 410<br><0.5W for Blank-Type, <1.2W for A-Type<br>**NO LOAD POWER CONSUMPTION**<br>**WORKING TEMP.**<br>**MAX. CASE TEMP.**<br>Tcase=-20 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>Tcase=+85℃<br>Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743,GB17625.1, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV), EAC TP TC 020<br>℃<br><br><br><br><br><br>℃℃<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC<br>PF>0.95/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>0.4A/230VAC 0.3A/277VAC<br>**RATED CURRENT**<br>UL8750,CSA C22.2 NO.250.13-12; EN/AS/NZS 61347-1 & EN/AS/NZS 61347-2-13 independent, EN62384,<br>GB19510.1,GB19510.14, BIS IS15885(for IDLV-65-12,24,48 only), EAC TP TC 004 approved||**IDLV-65 -12**|**IDLV-65 -24**|**IDLV-65 -36**|**IDLV-65 -48**|**IDLV-65 -60**| ||**DC VOLTAGE**|12V|24V|36V|48V|60V| ||**RATED CURRENT**|4.2A|2.4A|1.8A|1.35A|1.08A| ||**RATED POWER**|50.4W|57.6W|64.8W|64.8W|64.8W| ||**DIMMING RANGE**|0~100%||||| ||**VOLTAGE TOLERANCE**|±10%||||| ||**PWM FREQUENCY (Typ.)**|1KHz(±20%)||||| ||**SETUP TIMENote.3**|500ms / 230VAC||||| ||**AUXILIARY DC OUTPUTNote.4**|Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only||||| ||**VOLTAGE RANGENote.2**|(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC 254 ~ 417VDC||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||| ||**POWER FACTOR (Typ.)**|PF>0.95/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load≧60%/230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)||||| ||**EFFICIENCY (Typ.)**|85%|87%|88%|89%|90%| ||**AC CURRENT (Typ.)**|0.4A/230VAC 0.3A/277VAC||||| ||**INRUSH CURRENT(Typ.)**|COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>270μ<br>;Per NEMA 410||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC||||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC||||| ||**NO LOAD POWER CONSUMPTION**|<0.5W for Blank-Type, <1.2W for A-Type||||| ||**SHORT CIRCUIT**|Shut down O/P voltage, re-power on to recovery||||| ||**OVER CURRENT**|105 ~ 115%<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||| ||**WORKING TEMP.**|Tcase=-20 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)||||| ||**MAX. CASE TEMP.**|Tcase=+85℃||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 40℃)||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes||||| ||**SAFETY STANDARDS**|UL8750,CSA C22.2 NO.250.13-12; EN/AS/NZS 61347-1 & EN/AS/NZS 61347-2-13 independent, EN62384,<br>GB19510.1,GB19510.14, BIS IS15885(for IDLV-65-12,24,48 only), EAC TP TC 004 approved||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC||||| ||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH||||| ||**EMC EMISSION**|Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743,GB17625.1, EAC TP TC 020||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV), EAC TP TC 020||||| ||**MTBF**|398.7K hrs min. MIL-HDBK-217F (25℃)||||| ||**DIMENSION**|130*75*25mm (L*W*H)||||| ||**PACKING**<br>0.23Kg;54pcs/13.5Kg/ 0.96CUFT<br>℃<br><br><br><br><br><br>℃℃|||||| _File Name:IDLV-65-SPEC 2019-07-25_ **- IDLV 65 series** 65W PWM Output LED Driver ## **DIMMING OPERATION** **==> picture [24 x 51] intentionally omitted <==** **----- Start of picture text -----**<br> ACL<br>ACNACL TB1<br>ACN<br>DIM+<br>DIM-Vo+ TB2<br>Vo-<br>**----- End of picture text -----**<br> ※ **Dimming principle for PWM style output** - ‧Dimming is achieved by varying the duty cycle of the output current. **==> picture [387 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> ON<br>Output DC current<br>TON<br>Duty cycle(%) = ×100%<br>T<br>OFF Output PWM frequency : 1KHz(±20%)<br>Io=0A<br>TON<br>T<br>**----- End of picture text -----**<br> ※ **2 in 1 dimming function** **==> picture [101 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 0 ~ 10VDC<br>**----- End of picture text -----**<br> **==> picture [215 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>Vo+ +<br>-<br>Vo- -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to Vo-”<br>**----- End of picture text -----**<br> **==> picture [224 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 10V PWM signal (frequency range 300Hz~3KHz):<br>**----- End of picture text -----**<br> **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>Vo+ +<br>-<br>Vo- -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to Vo-”<br>**----- End of picture text -----**<br> **==> picture [163 x 302] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>Duty cycle of output current (%)<br>Duty cycle of output current (%)<br>**----- End of picture text -----**<br> Note : 1. Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%. 2. The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle. 3. To ensure the dimming effect, total power must be over 45W at 100% duty cycle. _File Name:IDLV-65-SPEC 2019-07-25_ **- IDLV 65 series** 65W PWM Output LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [493 x 609] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>-20 -10 0 5 10 20 30 40 (HORIZONTAL) -20 -10 0 15 30 45 75 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>100<br>1.00<br>90<br>0.96<br>80<br>0.92<br>70<br>0.88 277V<br>60 0.84<br>230V<br>50 0.80<br>40 0.76<br>0.72<br>180 200 230 260 295 50% 60% 70% 80% 90% 100%<br>(65W)<br>INPUT VOLTAGE (V) LOAD<br>※De-rating is needed under low input voltage.<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>IDLV-65 series possess superior working efficiency that up to 90% can<br>be reached in field applications.<br>※ 60V Model,Tcase at 75℃ ※ 60V Model,Tcase at 75℃<br>94%<br>18<br>90%<br>16<br>14 86%<br>12 82% 277V<br>277VAC<br>10 78%<br>230VAC 230V<br>8 74%<br>6<br>70%<br>4<br>66%<br>2<br>0 62%<br>50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:IDLV-65-SPEC 2019-07-25_ **- IDLV 65 series** 65W PWM Output LED Driver **==> picture [93 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> BLOCK DIAGRAM<br>**----- End of picture text -----**<br> **==> picture [486 x 628] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 70-150KHz<br>RECTIFIERS AUX+(for A-Type)<br>AUX-(for A-Type)<br>EMI FILTER POWER RECTIFIERS Vo+<br>I/P & SWITCHING &<br>RECTIFIERS FILTER Vo-<br>CURRENT DIM+<br>LIMIT DIM-<br>O.L.P. DETECTION<br>PWM&PFC CIRCUIT<br>CONTROL<br>MECHANICAL SPECIFICATION<br>※ Blank-Type Case No.IDLC-65A Unit:mm<br>130<br>6.5 ‧ : Max. Case Temperaturetc<br>1<br>2 TB1<br>3<br>4<br>1<br>2 30<br>3 [TB2] tc<br>4<br>6.5<br>NOTE: Please use wires with a cross section of 0.75~1.5mm for TB1 2<br> and wires with a cross section of 0.5~1.5mm for TB2. 2<br>Terminal Pin No. Assignment(TB1)<br>Terminal Pin No. Assignment(TB2)<br>Pin No. Assignment Pin No. Assignment<br>1 ACL<br>1 DIM+<br>2 ACL<br>2 DIM-<br>3 ACN<br>3 Vo+<br>4 ACN<br>4 Vo-<br>6.5<br>75<br>6.5<br>30<br>25 3<br>**----- End of picture text -----**<br> _File Name:IDLV-65-SPEC 2019-07-25_ **- IDLV 65 series** 65W PWM Output LED Driver **==> picture [34 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> ※ A-Type<br>**----- End of picture text -----**<br> **==> picture [395 x 229] intentionally omitted <==** **----- Start of picture text -----**<br> 130<br>6.5 ‧ : Max. Case Temperaturetc<br>1<br>32 TB1<br>4<br>1<br>324 TB2 tc 30<br>5<br>6<br>6.5<br>NOTE: Please use wires with a cross section of 0.75~1.5mm for TB1 2<br> and wires with a cross section of 0.5~1.5mm for TB2. 2<br>6.5<br>75<br>6.5<br>30<br>25 3<br>**----- End of picture text -----**<br> |Terminal Pin No. Assignment(TB1)<br>Pin No.<br>1<br>2<br>Assignment<br>ACL<br>ACL<br>Terminal Pin No. Assignment(TB2)<br>Pin No.<br>Pin No.<br>1<br>2<br>3<br>4<br>5<br>6<br>Assignment<br>Assignment<br>DIM+<br>Vo-<br>AUX+<br>AUX-<br>DIM-<br>Vo+<br>3<br>4<br>ACN<br>ACN|Terminal Pin No. Assignment(TB1)<br>Pin No.<br>1<br>2<br>Assignment<br>ACL<br>ACL<br>Terminal Pin No. Assignment(TB2)<br>Pin No.<br>Pin No.<br>1<br>2<br>3<br>4<br>5<br>6<br>Assignment<br>Assignment<br>DIM+<br>Vo-<br>AUX+<br>AUX-<br>DIM-<br>Vo+<br>3<br>4<br>ACN<br>ACN| |---|---| |Pin No.|Assignment| |1|ACL| |2|ACL| |3|ACN| |4|ACN| ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:IDLV-65-SPEC 2019-07-25_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →