IDLNK21-1REC5-38140-30-G1
MAGNETIC HYDRAULIC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA / PARTNER STOCK
- Product type: Magnetic Hydraulic Circuit Breakers
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 183.61 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **| PGFM SERIES (ELCI, MARINE)** ELCI MARINE GROUND FAULT PROTECTION SENSING MODULE ## Introduction The LineGard™ PGFM product family provides ELCI (equipment leakage) ground fault sensing and is designed and manufactured by North Shore Safety, a leader in innovative safety products. The PGFM series operates in tandem with an Airpax™ LEL series, UL 489 listed circuit breaker, with shunt trip and auxiliary switch manufactured by Sensata Technologies. The PGFM can be paired with an Airpax™ IDLNK breaker for applications requiring ignition protection. The combined assembly of the PGFM and an Airpax™ breaker meets the requirements of ABYC E-11 for ground fault protection and main shore power circuit protection. The PGFM constantly monitors the current balance of the conductors (wires / cables) supplying power to the load. When a ground fault of 27mA nominal (30 mA max) occurs, the PGFM uses the LEL’s shunt trip coil to signal the breaker to trip. ## Features - Power and fault status indicators - Provides identification of a ground fault vs. short circuit trip - Chemical and UV resistant enclosure - Trip level of sensing device < 30mA (27mA nominal) at trip time of < 100mS (60mS nominal) per E-11 - Protection range and operating voltage: 0 - 50 Amps, 120 VAC, 120/240 VAC - Unit operating temperature is -35°C to +66°C - Accommodates up to 3 wires, 6 AWG, with no twisting of the wires required ## **SPECIFICATIONS** |**SPECIFICATIONS**<br>@|| |---|---| |**Type**|E-11 GFP - UL 943 Category FTTJ2 when used in tandem with Airpax LEL series (UL 489 listed circuit<br>breaker with shunt trip)| |**Operating Voltage **|120 VAC or 120/240 VAC, 50/60 Hz| |**Interrupting Voltage**|Rating of UL 489 listed circuit breaker| |**Sensing Coil Voltage Limit**|600 VAC maximum| |**Phase Interrupt**|Single (120 VAC 3 wire), Split (120/240 VAC 4 wire) , 240VAC 3-wire (L1, L2, N)| |**Interrupting Current**|120VAC, 50A, 5kAIC<br>120/240VAC, 50A, 5kAIC| |**Trip Time of Combined Assembly**|100mS or less (60mS nominal)| |**Trip Level**|27mA +/- 3mA| |**Operating Temperature**|-35°C to +66°C| |**Reset Type**|Automatic on power up| |**ABYC E-11 Acceptability**|The LineGard™ PGFM ELCI module used in tandem with the Airpax™circuit breaker meets<br>the requirements of the ABYC (American Boat and Yacht Council) E-11 standard covering<br>AC and DC systems on boats| Note: 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 2. As per UL 943 requirements, portable devices may require breaking of neutral during ground fault detection. Please contact the factory. 3. Please contact Airpax for optional ELCI, UL 1053 compliant devices. Page 1 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## AIRPAX™ LEL & IDLNK SERIES CIRCUIT BREAKER RATINGS (PER UL489) |**Voltage**|**Current**<br>**Frequen**|**cy**<br>**Short Circuit**|**Poles**| |---|---|---|---| |125VAC|0.05 to 50 amps<br>50/60 H|z<br>5,000 amps|1 to 3| |120/240VAC|.05 to 50 amps<br>50/60 H|z<br>5,000 amps|2 to 3| ## AIRPAX™ LEL & IDLNK SERIES CIRCUIT BREAKER SPECIFICATIONS |**Moisture Resistance**|MIL-STD-202, Method 106| |---|---| |**Salt Spray (Corrosion)**|MIL-STD-202, Method 101| |**Shock**|MIL-STD-202, Method 213, Test Condition I with 100% rated current applied| |**Vibration**|MIL-STD-202, Method 204, Test Condition A with 100% rated current applied| |**LEL Agency Approvals**|UL489 Listed, CSA Certifed, VDE Approved, CCC Approved, CE Compliant| |**IDLNK Agency Approvals**|UL 1077 Recognized, C22.2 No. 235 complaint to UL 1500 or SAE J1171 ignition protection| |**Salt Fog (Corrosion)**|ASTM B117| |---|---| |**Shock**|33CFR183.534 - modifed to supply 5,000 shocks @ 25G, instead of test standard of 1,000 shock| |**Vibration**|MIL-STD-810 (random vibe 4G RMS), IEC 6945 (sine sweep 5 to 100 Hz for low frequency)| |**Ignition Protection**|SAE J1171 (UL1500)| ## **WIRING DIAGRAM** ## Wiring Diagram (120VAC APPLICATION) **==> picture [523 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL (white) to breaker line side NEUTRAL<br>HOT (black) to master pole* of breaker<br>SHUNT (yellow) to breaker auxiliary switch (NO terminal)<br>NEUTRAL (white) from power supply (source) NEUTRAL (white) to breaker line input<br>HOT (black) from power supply (source) HOT (black) to master pole* of breaker<br>**----- End of picture text -----**<br> ## Wiring Diagram (240 VAC APPLICATION) **==> picture [505 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> L1 (black) to master pole* of breaker<br>L2 (red) to breaker line side L2<br>SHUNT (yellow) to breaker auxiliary switch (NO terminal)<br>L1 (black) from power supply (source) L1 (black) to master pole* of breaker<br>L2 (red) from power supply (source) L2 (red) to circuit breaker line input<br>**----- End of picture text -----**<br> Page 2 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com Wiring Diagram (120/240 VAC APPLICATION) **==> picture [110 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> L1 (black) from power supply (source)<br>L2 (red) from power supply (source)<br>NEUTRAL (white) from power supply (source)<br>**----- End of picture text -----**<br> **==> picture [413 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> L1 (black) to master pole* of breaker<br>NEUTRAL (white) to breaker line side NEUTRAL<br>SHUNT (yellow) to breaker auxiliary switch (NO terminal)<br>L1 (black) to master pole* of breaker<br>L2 (red) to circuit breaker line input<br>NEUTRAL (white) to circuit breaker line input<br>*Master pole is the pole that houses the toggle handle on the breaker<br>**----- End of picture text -----**<br> ## Wiring Diagram (Orange Jumper Wire For Circuit Breaker) **==> picture [136 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> LINE<br>C<br>NO<br>LOAD<br>**----- End of picture text -----**<br> ## **DANGER!** Hazard of electrical shock, burn or explosion. Disconnect power at main power feed before you start installation. Failure to do so may cause severe shock, personal injury, or death. ## Installation Instructions ## Testing And Troubleshooting In the normal operating state, the PGFM green LED is “ON” and circuit breaker is in the “ON” position. 1. Read and follow all instructions 2. Identify all the features and wires (see drawings) 1. Press “TEST” button: Green LED should go “OFF” and red LED should come “ON” and circuit breaker should trigger to “OFF” position 3. Identify line wires and load wires 4. Verify that the ratings on the device, including the circuit breaker, match your field line ratings 2. If sensing device red LED does not illuminate or breaker does not trip or change state, DO NOT USE and consult an electrician for assistance 5. Strip wires to 5/8”, or as recommended for your connections (module may include field terminations) 6. Choose the right wiring application (120VAC or 120/240VAC split phase) and connect wires according to diagrams 3. Press “RESET” button: Red LED should turn “OFF” and green LED should turn “ON” 4. Manually reset (switch) the circuit breaker to the “ON” position to restore circuit power 7. Place supplied test instruction label in close proximity to the ground fault sensing module mounting location. WARNING: If the test fails, do not use this ELCI. Consult a qualified electrician for repair or replacement NOTE: The ground wire should be connected externally. The Ground wire does not enter or exit the ground fault sensing module. Although the PGFM does not monitor ground leads or require ground to operate, ground connection is recommended and should be made at junction box. Page 3 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **DIMENSIONAL DRAWINGS** ## Dimensional Drawings (Pgfm Marine) **==> picture [536 x 396] intentionally omitted <==** **----- Start of picture text -----**<br> .710 [18.03] DIAMETER<br>(LARGE ENOUGH FOR THREE 6GA. WIRES)<br>0.007 [0.18]<br>1.320 [33.53]<br>0.657 [16.68]<br>16 GA. WIRE 105 DEGREES C<br>UL STYLE 1015 / 1230 600V<br>2.353 [59.77] CSA TEW 10 IN LONG +/- 1 IN 2.655 [67.44] DIAMETER<br>1.850 [46.99] COLOR WIRE 1: WHITE 120V, RED 240V<br>COLOR WIRE 2: BLACK 120V, BLACK 240V 2.788 [70.82] DIAMETER<br>M3.0 x .5 THREADED BRASS COLOR WIRE 3: YELLOW 120V, YELLOW 240V<br>INSERTS FOR MOUNTING (2) PLACES WIRE 3 WITH QUICK DISCONNECT MOLEX PN<br>19006-0015 OR EQUIVALENT<br>3.41<br>[86.6]<br>2.52<br>[64.0]<br>2.62<br>[66.5]<br>1.30 3.67<br>[33.0] [93.2]<br>2.18<br>[55.4]<br>M3 inserts<br>Recommended torque 4 - 5<br>inch pounds<br>3.28<br>[83.3]<br>**----- End of picture text -----**<br> ## Dimensional Drawings (Example Of Lel, Typical 2-Pole Configuration) **==> picture [525 x 247] intentionally omitted <==** **----- Start of picture text -----**<br> .356<br>.721 .250 [9.03]<br>.187 [18.31] [6.35]<br>[4.75]<br>.250<br>[6.35]<br>1REC5<br>C & NO<br>1.147<br>[29.13]<br>4X M3 ISO THD.<br>.281 2.438 MAX. .140 .140 [3.56] DEEP<br>[0.76].030 [7.14] [61.93] [3.56] [10.21].402 [5.59].220<br>.648 ON<br>[65.02]2.560 [26.80]1.055 [16.46] 32˚ [63.25]2.490<br>1.438 2.060<br>1.940 32˚ [36.53] [52.32]<br>[49.28]<br>OFF<br>4X M5 SCREW .955 1.515 MAX. [19.05].750<br>[24.25] [38.48]<br>[3.61].142 [47.22]1.859 [17.53].690 Panel MountingDetail<br>Tolerance ±.005[.13]unless noted.<br>Page 4<br>20<br>C<br>NO<br>NC<br>**----- End of picture text -----**<br> **==> picture [149 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Copyright © 2024 Sensata Technologies, Inc.<br>**----- End of picture text -----**<br> www.sensata.com ## Compatible Airpax™ Circuit Breakers - UL 489 Listed; Vde Per En 60934 (Non-Ignition Protected) |**Amps**|**Poles**|**Part Number**|**Voltage**|**Trip Coil**|**Short Circuit**||**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |30|2|LEL12-1REC5-37583-30-G1-V|120V|120V|5000A|TIME IN SECONDS<br>10<br>1<br>.1<br>1000<br>100<br>.01<br>10000<br>.001|||||||||||00<br>1000<br>900<br>**63**|| |||||||||Y TRIP|||||||**DELAY**||**63**|| |30|2|LEL12-1REC5-37583-30-G2-V|240V|240V|5000A|||MA||||||||||| |30|3|LEL121-1REC5-37275-30-G1-V|120/240V|120V|5000A|||||||||||||| |||||||||||||||||||| |||||||||||||||||||| |50|2|LELK12-1REC5-37583-50-G1-V|120V|120V|5000A|||||||||||||| |||||||||||||||||||| |||||||||||||||||||| |50|2|LELK12-1REC5-37583-50-G2-V|240V|240V|5000A|||||||||||||| |||||||||||||||||||| |50|3|LELK121-1REC5-37275-50-G1-V|120/240V|120V|5000A|||||||||||||| ||||||||6<br>500<br>400<br>300<br>200<br>150<br>125<br>100<br>0<br><br>PERCENT OF RATED||||||||8<br>700<br>00<br>CURRENT|||| ## Dimensional Drawings (Example Of Idlnk, Typical 2-Pole Configuration) **==> picture [464 x 177] intentionally omitted <==** **----- Start of picture text -----**<br> KEYWAY<br>.0625 ± 0.0025 [1.59 ± 0.064] WIDE<br>.0325 ± 0.0025 [0.83 ± 0.064] DEEP<br>.625 .750<br>[15.88] [19.05] 1.515 MAX<br>.130 [38.48]<br>[3.30] 6-32 Mtg Screw<br>for High Shock<br>Mtg 1.375 .750<br>ON 13 ˚ ± 3˚ [34.92] .656 2.490 [19.05] .656<br>[16.66] [63.25] [16.66]<br>.515<br>OFF [13.08]<br>13 ˚ ± 3˚<br>1/2-32 Hex Nut<br>Lockwasher<br>.142<br>.955 Rubber “O” Ring<br>[3.61]<br>[24.25]<br>2.040 Panel MountingDetail<br>[51.82] Tolerance ±.005[.13]unless noted.<br>**----- End of picture text -----**<br> ## Compatible Airpax™ Circuit Breakers - UL 1077 Recognized; Ignition Protected Per Sae J1171 (UL 1500) |**Amps**|**Poles**|**Part Number**|**Voltage**|**Trip Coil**|**Short Circuit**||**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**|**Delay Curve**||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |30|2|IDLNK21-1REC5-38140-30-G1|120V|120V|5000A|TIME IN SECONDS<br>10<br>1<br>.1<br>1000<br>100<br>.01<br>10000<br>.001|||||||||||00<br>1000<br>900<br>**63**|| |||||||||Y TRIP|||||||**DELAY**||**63**|| |30|2|IDLNK21-1REC5-38140-30-G2|240V|240V|5000A|||MA||||||||||| |30|3|IDLNK121-1REC5-39945-30-G1|120/240V|120V|5000A|||||||||||||| |||||||||||||||||||| |||||||||||||||||||| |50|2|IDLNK21-1REC5-38140-50-G1|120V|120V|5000A|||||||||||||| |||||||||||||||||||| |||||||||||||||||||| |50|2|IDLNK21-1REC5-38140-50-G2|240V|240V|5000A|||||||||||||| |||||||||||||||||||| |50|3|IDLNK121-1REC5-39945-50-G1|120/240V|120V|5000A|||||||||||||| ||||||||6<br>500<br>400<br>300<br>200<br>150<br>125<br>100<br>0<br><br>PERCENT OF RATED||||||||8<br>700<br>00<br>CURRENT|||| Page 5 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **ORDERING OPTIONS** ## ELCI Marine (Round) Modules **PGFM-111-B-A1-188** UP TO 50A 120V AUTO ROUND MARINE 27mA +/- 3mA ELCI **PGFM-111-B-A1-188A** UP TO 50A 120V AUTO ROUND MARINE 27mA +/- 3mA (Turned 90 Degrees) ELCI **PGFM-211-B-A1-188** UP TO 50A 240V AUTO ROUND MARINE 27mA +/- 3mA ELCI **PGFM-211-B-A1-188A** UP TO 50A 240V AUTO ROUND MARINE 27mA +/- 3mA (Turned 90 Degrees) ELCI ## Elevated Trip Mod’s **PGFM-111-B-A1-187** UP TO 50A 120V AUTO RECT. MOD (POTTED) 27mA +/- 3mA ELwCI **PGFM-211-B-A1-187** UP TO 50A 240V AUTO RECT. MOD (POTTED) 27mA +/- 3mA ELCI **PGFM-211-B-A1-291** UP TO 50A 240V AUTO RECT. MOD 18mA +/- 2mA ELCI ## Class A Mod’s **PGFM-111-B-A1** UP TO 50A 120V AUTO RECT. MOD (W/ SHUNT TRIP) 5mA +/- 1mA GFCI ~~——E~~ ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions can result in death or serious injury.** Page 6 Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS- RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** 508-236-2551 electrical-protection-sales@ sensata.com **Europe, Middle East & Africa** +31743578156 info-sse@list.sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Copyright © 2024 Sensata Technologies, Inc. Revised 09/18/24 www.sensata.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →