IC70-16P-K
In Cabinet IO-Link Hub, Converter, 16 PNP Input/Output, IP20, IC70 Series
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (21-Jan-2025)
- Accuracy %: -
- Product Range: IC70 Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 16 Channel
- Output Accuracy: -
- No. of Output Channels: 16Channels
- Signal Conditioner Input: PNP
- Signal Conditioner Output: PNP
- Signal Conditioner Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 145.78 € |
| Current stock | 10+ |
| Lead time | 30 days |
IC70-16P-K IO-Link Data Reference Guide ## IO-Link Data Reference Guide This document refers to the following IODD file: Banner_Engineering-IC70-16P-K-20241101-IODD1.1.xml. The IODD file and support files can be found on www.bannerengineering.com under the download section of the product family page. ## Communication Parameters **==> picture [500 x 565] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Value Parameter Value<br>IO-Link revision V1.1 Port class A<br>Process data in length 16-bits SIO mode Yes<br>Process data out length 16-bits Smart sensor profile No<br>Bit rate 38400 bps Block parameterization Yes<br>Minimum cycle time 3.3 ms Data storage Yes<br>Device ID 659478<br>Process Data In (Device to Master)<br>Subindex Name Number of Bits Data Values<br>1 Channel 1 Input State 1 false=inactive, true=active<br>2 Channel 2 Input State 1 false=inactive, true=active<br>3 Channel 3 Input State 1 false=inactive, true=active<br>4 Channel 4 Input State 1 false=inactive, true=active<br>5 Channel 5 Input State 1 false=inactive, true=active<br>6 Channel 6 Input State 1 false=inactive, true=active<br>7 Channel 7 Input State 1 false=inactive, true=active<br>8 Channel 8 Input State 1 false=inactive, true=active<br>9 Channel 9 Input State 1 false=inactive, true=active<br>10 Channel 10 Input State 1 false=inactive, true=active<br>11 Channel 11 Input State 1 false=inactive, true=active<br>12 Channel 12 Input State 1 false=inactive, true=active<br>13 Channel 13 Input State 1 false=inactive, true=active<br>14 Channel 14 Input State 1 false=inactive, true=active<br>15 Channel 15 Input State 1 false=inactive, true=active<br>16 Channel 16 Input State 1 false=inactive, true=active<br>Octet 0<br>Subindex 8 7 6 5 4 3 2 1<br>Bit offset 15 14 13 12 11 10 9 8<br>Value 1 1 1 1 1 1 0 1<br>Octet 1<br>Subindex 16 15 14 13 12 11 10 9<br>Bit offset 7 6 5 4 3 2 1 0<br>Value 1 1 1 0 1 1 1 0<br>Example based on the listed values<br>1 Channel 1 input state active 9 Channel 9 input state inactive<br>2 Channel 2 input state inactive 10 Channel 10 input state active<br>Continued on page 2<br>**----- End of picture text -----**<br> Original Instructions 05-Feb-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com p/n: 247609 Rev. A IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 1<br>3 Channel 3 input state active 11 Channel 11 input state active<br>4 Channel 4 input state active 12 Channel 12 input state active<br>5 Channel 5 input state active 13 Channel 13 input state inactive<br>6 Channel 6 input state active 14 Channel 14 input state active<br>7 Channel 7 input state active 15 Channel 15 input state active<br>8 Channel 8 input state active 16 Channel 16 input state active<br>**----- End of picture text -----**<br> ## Process Data Out (Master to Device) **==> picture [500 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> Subindex Name Number of Bits Data Values<br>1 Channel 1 Output State 1 false=Off/InActive, true=On/Active<br>2 Channel 2 Output State 1 false=Off/InActive, true=On/Active<br>3 Channel 3 Output State 1 false=Off/InActive, true=On/Active<br>4 Channel 4 Output State 1 false=Off/InActive, true=On/Active<br>5 Channel 5 Output State 1 false=Off/InActive, true=On/Active<br>6 Channel 6 Output State 1 false=Off/InActive, true=On/Active<br>7 Channel 7 Output State 1 false=Off/InActive, true=On/Active<br>8 Channel 8 Output State 1 false=Off/InActive, true=On/Active<br>1 Channel 9 Output State 1 false=Off/InActive, true=On/Active<br>2 Channel 10 Output State 1 false=Off/InActive, true=On/Active<br>3 Channel 11 Output State 1 false=Off/InActive, true=On/Active<br>4 Channel 12 Output State 1 false=Off/InActive, true=On/Active<br>5 Channel 13 Output State 1 false=Off/InActive, true=On/Active<br>6 Channel 14 Output State 1 false=Off/InActive, true=On/Active<br>7 Channel 15 Output State 1 false=Off/InActive, true=On/Active<br>8 Channel 16 Output State 1 false=Off/InActive, true=On/Active<br>Octet 0<br>Subindex 8 7 6 5 4 3 2 1<br>Bit offset 15 14 13 12 11 10 9 8<br>Octet 1<br>Subindex 16 15 14 13 12 11 10 9<br>Bit offset 7 6 5 4 3 2 1 0<br>**----- End of picture text -----**<br> ## Parameters Set Using IO-Link These parameters can be read from and/or written to an IC70-16P-K IO-Link Hub. Also included is information about whether the variable in question is saved during data storage and whether the variable came from the IO-Link Smart Sensor Profile. Unlike process data in, which is transmitted from the IO-Link device to the IO-Link master cyclically, these parameters are read or written acyclically as needed. **==> picture [500 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>0 1-16 Direct Parameter Page 1 (incl. ro<br>Vendor ID & Device ID)<br>1 1-16 Direct Parameters Page 2 rw<br>130 = Restore Factory Settings 162 = Start<br>2 System Command discovery 163 = Stop discovery 164 = Reset All wo<br>Metrics<br>Data Storage Index (device-<br>3 specific list of parameters to be rw<br>stored)<br>4-11 reserved by IO-Link Specification<br>Continued on page 3<br>**----- End of picture text -----**<br> page 2 of 10 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 666] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 2<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>12 Device Access Locks<br>12 1 Parameter Write Access Lock 0 = off 1 = on 0 rw y<br>12 2 Data Storage Lock 0 = off, 1 = on 0 rw y<br>12 3 Local Parameterization Lock 0 = off, 1 = on 0 rw y<br>12 4 Local User Interface Lock 0 = off, 1 = on 0 rw y<br>16 Vendor Name string Banner Engineering Corporation ro<br>17 Vendor Text string More Sensors. More Solutions. ro<br>18 Product Name string IC70-16P-K ro<br>19 Product ID string IC70-16P-K ro<br>20 Product Text string ro<br>21 Serial Number ro<br>23 Firmware Version ro<br>24 App Specific Tag (user-defined) rw y<br>0=Device is OK, 1=Maintainance required, 2=Out of<br>36 Device Status 8-bit integer specification, 3=Functional check, 4=Failure, 5..255 ro<br>Reserved<br>37 Detailed Device Status Array[6] of 3- ro<br>octet<br>38-39 reserved<br>40 Process Data Input see Process Data In ro<br>41 Process Data Output see Process Data Out ro<br>42-57 unused/reserved<br>69 All-Time Run Time<br>69 1 Run counter 32-bit Uinteger 0..2147483647 ro y<br>70 Resettable Run Time<br>70 1 Run counter 32-bit Uinteger 0..2147483647 0 rw<br>78 All-Time Run Time Event Time<br>78 1 Event Time 32-bit Uinteger 0..2147483647 0 rw y<br>79 Resettable Run Time Event Time<br>79 1 Event Time 32-bit Uinteger 0..2147483647 0 rw y<br>80 IO Metrics Channels 1 to 8<br>80 1 Channel 1 Count 32-bit Uinteger 0..2147483647 ro<br>80 2 Channel 1 Count Duration - 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 3 Channel 1 Count Events per Minute 32-bit Uinteger 1..300000 ro<br>Channel 1 CountTotalizer<br>80 4 Counter 32-bit Uinteger 0..2147483647 ro<br>80 5 Channel 2 Count 32-bit Uinteger 0..2147483647 ro<br>80 6 Channel 2 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 7 Channel 2 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 8 Channel 2 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>80 9 Channel 3 Count 32-bit Uinteger 0..2147483647 ro<br>80 10 Channel 3 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 11 Channel 3 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 12 Channel 3 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>80 13 Channel 4 Count 32-bit Uinteger 0..2147483647 ro<br>80 14 Channel 4 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 15 Channel 4 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 16 Channel 4 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>80 17 Channel 5 Count 32-bit Uinteger 0..2147483647 ro<br>80 18 Channel 5 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>Continued on page 4<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 10 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 673] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 3<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>80 19 Channel 5 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 20 Channel 5 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>80 21 Channel 6 Count 32-bit Uinteger 0..2147483647 ro<br>80 22 Channel 6 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 23 Channel 6 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 24 Channel 6 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>80 25 Channel 7 Count 32-bit Uinteger 0..2147483647 ro<br>80 26 Channel 7 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 27 Channel 7 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 28 Channel 7 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>80 29 Channel 8 Count 32-bit Uinteger 0..2147483647 ro<br>80 30 Channel 8 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>80 31 Channel 8 Events per Minute 32-bit Uinteger 1..300000 ro<br>80 32 Channel 8 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 IO Metrics Channels 9 to 16<br>81 1 Channel 9 Count 32-bit Uinteger 0..2147483647 ro<br>81 2 Channel 9 Duration - 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 3 Channel 9 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 4 Channel 9 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 5 Channel 10 Count 32-bit Uinteger 0..2147483647 ro<br>81 6 Channel 10 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 7 Channel 10 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 8 Channel 10 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 9 Channel 11 Count 32-bit Uinteger 0..2147483647 ro<br>81 10 Channel 11 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 11 Channel 11 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 12 Channel 11 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 13 Channel 12 Count 32-bit Uinteger 0..2147483647 ro<br>81 14 Channel 12 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 15 Channel 12 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 16 Channel 12 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 17 Channel 13 Count 32-bit Uinteger 0..2147483647 ro<br>81 18 Channel 13 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 19 Channel 13 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 20 Channel 13 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 21 Channel 14 Count 32-bit Uinteger 0..2147483647 ro<br>81 22 Channel 14 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 23 Channel 14 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 24 Channel 14 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 25 Channel 15 Count 32-bit Uinteger 0..2147483647 ro<br>81 26 Channel 15 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 27 Channel 15 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 28 Channel 15 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>81 29 Channel 16 Count 32-bit Uinteger 0..2147483647 ro<br>81 30 Channel 16 Duration 32-bit Uinteger 0..2147483647, 50µS resolution ro<br>81 31 Channel 16 Events per Minute 32-bit Uinteger 1..300000 ro<br>81 32 Channel 16 Totalizer Counter 32-bit Uinteger 0..2147483647 ro<br>82 Selectable Metric Reset<br>82 1 Channel 1 Boolean false=Do Not Reset, true=Reset false rw<br>Continued on page 5<br>**----- End of picture text -----**<br> page 4 of 10 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 665] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 4<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>82 2 Channel 2 Boolean false=Do Not Reset, true=Reset false rw<br>82 3 Channel 3 Boolean false=Do Not Reset, true=Reset false rw<br>82 4 Channel 4 Boolean false=Do Not Reset, true=Reset false rw<br>82 5 Channel 5 Boolean false=Do Not Reset, true=Reset false rw<br>82 6 Channel 6 Boolean false=Do Not Reset, true=Reset false rw<br>82 7 Channel 7 Boolean false=Do Not Reset, true=Reset false rw<br>82 8 Channel 8 Boolean false=Do Not Reset, true=Reset false rw<br>82 9 Channel 9 Boolean false=Do Not Reset, true=Reset false rw<br>82 10 Channel 10 Boolean false=Do Not Reset, true=Reset false rw<br>82 11 Channel 11 Boolean false=Do Not Reset, true=Reset false rw<br>82 12 Channel 12 Boolean false=Do Not Reset, true=Reset false rw<br>82 13 Channel 13 Boolean false=Do Not Reset, true=Reset false rw<br>82 14 Channel 14 Boolean false=Do Not Reset, true=Reset false rw<br>82 15 Channel 15 Boolean false=Do Not Reset, true=Reset false rw<br>82 16 Channel 16 Boolean false=Do Not Reset, true=Reset false rw<br>82 17 Channel 1 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 18 Channel 1 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 19 Channel 3 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 20 Channel 4 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 21 Channel 5 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 22 Channel 6 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 23 Channel 7 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 24 Channel 8 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 25 Channel 9 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 26 Channel 10 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 27 Channel 11 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 28 Channel 12 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 29 Channel 13 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 30 Channel 14 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 31 Channel 15 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>82 32 Channel 16 Reset Count 32-bit Uinteger 0..2147483647 0 rw<br>87 Channel 1 Configuration<br>87 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>87 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>87 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>87 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>87 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>87 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>87 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>88 Channel 2 Configuration<br>88 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>88 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>Continued on page 6<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 10 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 674] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 5<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>88 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>88 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>88 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>88 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>88 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>89 Channel 3 Configuration<br>89 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>89 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>89 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>89 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>89 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>89 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>89 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>90 Channel 4 Configuration<br>90 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>90 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>90 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>90 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>90 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>90 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>90 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>91 Channel 5 Configuration<br>91 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>91 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>91 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>91 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>91 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>91 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>91 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>92 Channel 6 Configuration<br>92 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>Continued on page 7<br>**----- End of picture text -----**<br> page 6 of 10 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 667] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 6<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>92 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>92 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>92 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>92 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>92 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>92 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>93 Channel 7 Configuration<br>93 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>93 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>93 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>93 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>93 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>93 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>93 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>94 Channel 8 Configuration<br>94 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>94 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>94 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>94 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>94 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>94 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>94 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>95 Channel 9 Configuration<br>95 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>95 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>95 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>95 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>95 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>95 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>Continued on page 8<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 10 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 661] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 7<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>95 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>96 Channel 10 Configuration<br>96 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>96 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>96 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>96 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>96 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>96 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>96 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>97 Channel 11 Configuration<br>97 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>97 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>97 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>97 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>97 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>97 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>97 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>98 Channel 12 Configuration<br>98 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>98 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>98 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>98 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>98 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>98 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>98 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>99 Channel 13 Configuration<br>99 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>99 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>99 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>99 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>99 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>Continued on page 9<br>**----- End of picture text -----**<br> page 8 of 10 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide **==> picture [500 x 589] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 8<br>Index Subindex Name Length Value Range Default Access Rights Data Storage?<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>99 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>99 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>100 Channel 14 Configuration<br>100 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>100 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>100 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>100 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>100 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>100 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>100 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>101 Channel 15 Configuration<br>101 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>101 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>101 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>101 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>101 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>101 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>101 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>102 Channel 16 Configuration<br>102 1 IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 3 rw y<br>0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3<br>102 2 Delay Mode 8-bit Uinteger = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On 0 rw y<br>One-shot, 8 = Retriggerable Off One-Shot<br>102 3 Delay Timer 1 32-bit Uinteger 0..2147483647 [Channel On Delay, One-shot, Pulse-stretcher time(ms) or Totalizer Count] 0 rw y<br>102 4 Delay Timer 2 32-bit Uinteger 0..2147483647 (Channel Off Delay or Totalizer time)ms 0 rw y<br>102 5 Mirroring Enable 8-bit Uinteger 0=Disabled, 1=Enabled 0 rw y<br>0=Channel 1, 1=Channel 2, 2=Channel 3,<br>3=Channel 4, 4=Channel 5, 5=Channel 6,<br>102 6 Mirroring Channel Selection 8-bit Uinteger 6=Channel 7, 7=Channel 8, 8=Channel 9, 9=Channel 10, 10=Channel 11, 11=Channel 12, 0 rw y<br>12=Channel 13, 13=Channel 14, 14=Channel 15,<br>15=Channel 16<br>102 7 Mirroring Inversion 8-bit Uinteger 0=Not Inverted, 1=Inverted 0 rw y<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 9 of 10 05-Feb-25 IC70-16P-K IO-Link Data Reference Guide ## IO-Link Events Events are acyclic transmissions from the IO-Link device to the IO-Link master. Events can be error messages and/or warning or maintenance data. **==> picture [500 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> Code Type Name Description<br>25376 (0x6320) Error Parameter error Check datasheet and values<br>36000 (0x8CA0) Warning All-time Run Time Event Event indicating the corresponding configured running time has<br>elapsed.<br>36001 (0x8CA1) Warning Resettable Run Time Event Event indicating the corresponding configured running time has<br>elapsed.<br>**----- End of picture text -----**<br> page 10 of 10 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 05-Feb-25
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →