Image not available
Illustrative purposes only
HY 15-P
Current Transducer, HY Series, 15A, -45A to 45A, 1 %, Voltage Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-45A to 45A; Current Measuring Range AC:-45A to 45A; Response Time:3µs; Accuracy %:1%; Prod
- SVHC: No SVHC (17-Jan-2022)
- Accuracy: 1%
- Product Range: HY Series
- Response Time: 3µs
- Primary Current: ± 15A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: ± 12V to ± 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 80°C
- Operating Temperature Min: -10°C
- Current Measuring Range AC: -45A to 45A
- Current Measuring Range DC: -45A to 45A
| Delivery and price | |
|---|---|
| Units per pack | 1000 |
| Price | 19.01 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducers HY 5..25-P**
## **I = 5 .. 25 A** PN
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
## **Electrical data**
**==> picture [336 x 205] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Primary nominal|Primary current,|Primary|Type|RoHS since|
|current rms|measuring range|conductor|date code|
|I|PN|(A)|I|PM|(A)|(mm)|
|5|± 15|∅ 0.7|HY 5-P|45260|
|10|± 30|∅|1.1|HY 10-P|45286|
|12.5|± 37.5|∅|1.4|HY 12-P|45264|
|15|± 45|∅|1.4|HY 15-P|45276|
|20|±|60|2 x ∅ 1.2|[1)]|HY 20-P|46097|
|25|± 75|2 x ∅ 1.4|[1)]|HY 25-P|45269|
|V|C|Supply voltage (± 5 %)|[6)]|± 12 .. 15|V|
|I|C|Current consumption|± 10|mA|
|Î|P|Overload capability (1 ms)|50 x|I|PN|
|V|d|Rms voltage for AC isolation test, 50 Hz, 1 min|2.5|kV|
|V|b|Rated isolation voltage rms|500|[2)]|V|
|R|IS|Isolation resistance @ 500 VDC|> 1000|MΩ|
|V|OUT|Output voltage (Analog) @ +|I|PN,|R|L = 10 kΩ,|T|A = 25°C|± 4|V|
|R|OUT|Output internal resistance|100|Ω|
|R|L|Load resistance|> 1|kΩ|
**----- End of picture text -----**<br>
## **Accuracy - Dynamic performance data**
**==> picture [336 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|X|Accuracy @|I|PN,|T|A = 25°C (excluding offset)|< ± 1|%|
|ε|L|Linearity error|[3)]|(0 .. ±|I|PN)|< ± 1|% of|I|PN|
|V|OE|Electrical offset voltage@|T|A = 25°C|< ± 40|mV|
|V|OH|Hysteresis offset voltage @|I|P = 0;|
|after an excursion of 1 x|I|PN|< ± 15|mV|
|TCV|OE|Temperature coefficient of|V|OE typ.|± 1.5|mV/K|
|max.|±|3|mV/K|
|TCV|OUT|Temperature coefficient of|V|OUT (% of reading)|< ± 0.1|%/K|
|t|r|Response time to 90% of|I|PN step|< 3|µs|
|di/dt|di/dt|accurately followed|> 50|A/µs|
|BW|Frequency bandwidth|[4)]|(- 3 dB)|DC .. 50|kHz|
|General data|
|T|A|Ambient operating temperature|- 10 .. + 80|°C|
|T|S|Ambient storage temperature|- 25 .. + 85|°C|
|m|Mass|< 14|g|
|Standards|[5)]|EN 50178: 1997|
**----- End of picture text -----**<br>
## **Features**
- Hall effect measuring principle
- Galvanic isolation between primary and secondary circuit
- Isolation voltage 2500 V~
- Compact design for PCB mounting
- Low power consumption
- Extended measuring range (3 x **I** PN)
- Insulated plastic case recognized according to UL 94-V0.
## **Advantages**
- Easy mounting
- Small size and space saving
- Only one design for wide current ratings range
- High immunity to external interference.
## **Applications**
- Static converters for DC motor drives
- Switched Mode Power Supplies (SMPS).
- AC variable speed drives
- Uninterruptible Power Supplies (UPS)
- Battery supplied applications
- General purpose inverters
## **Application domain**
- Industrial
- Notes : 1) Conductor terminals are soldered together.
- 2) Pollution class 2, overvoltage category III.
- 3) Linearity data exclude the electrical offset.
- 4) Please refer to derating curves in the technical file to avoid excessive core heating at high frequency.
- 5) Please consult characterisation report for more technical details and application advice.
- 6) Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061027/8
www.lem.com
## **Dimensions HY 5..25-P** (in mm. 1 mm = 0.0394 inch)
**==> picture [270 x 402] intentionally omitted <==**
**----- Start of picture text -----**<br>
36.0 Max.<br>32.0 Max. HY 5 to 15-P<br>JAPAN<br>18.0 12 Max.<br>12.0<br> HY 5-P<br> 45059<br>H Y 10 - P<br> 9639 JP2<br>J CAMs | | |<br>( d) (0.3)<br>(0.5)<br>3 x 2.54 10±0.3 8.5±0.3 (a)±0.3<br>3.9±0.3<br>1 2 3 4 5 6<br>HY 20 to 25-P<br>HY 20 - P PIN ARRANGEMENT<br> 9639<br>1 +15V<br>2 -- | 15V<br>3 OUTPUT<br>4 0V<br>3±0.5 ( dx2) 5 PRIMARY IN<br>3 x 2.54 10±0.3 8.5±0.3 6 PRIMARY OUT<br>PCB MOUNTING DIMENSIONS (in mm ±0.1, hole -0, +0.2)<br>2 holes dia. (e)<br>HY 5 to15-P<br>3 x 2.54 10 8.5<br>HY 20 to 25-P 4 holes dia 1 holes dia (e) mm mm mm mmType a d e g<br>HY 05-P 1.1 0.7 1.2 --<br>HY 10-P 1.4 1.1 1.6 --<br>HY 12-P 1.5 1.4 2.0 --<br>porte (g) OT (g) HY 15-P 1.5 1.4 2.0 --<br>HY 20-P 1.4 1.2 1.8 1.4<br>3 x 2.54 10 8.5 HY 25-P 1.5 1.4 2.0 1.6<br>**----- End of picture text -----**<br>
## **Safety**
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible after installation.
A protective housing or additional shield could be used. Main supply must be able to be disconnected.
Page 2/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061027/8
www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →