HWS600P-24
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 600 W, 24 VDC, 25 A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:600W; Output Voltage - Output 1:24V; Output Current - Output 1:25A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output
- SVHC: No SVHC (15-Jan-2018)
- Product Range: HWS-P Series
- No. of Outputs: 1Outputs
- Output Power Max: 600W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 265V AC
- Input Voltage AC Max: 265V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable
- Output Current - Output 1: 25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 598.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
- Limited Lifetime Warranty - 300% Peak Power Capability - Small Package Size - Universal Input (85 - 265VAC) - High Efficiency ## **Key Market Segments & Applications** ## HWS300P & 600P Series Peak Power Industrial Power Supplies Factory Automation Process Control Semiconductor Fabrication Motor and Pump Drives ## HWS300P & 600P Features and Benefits - Features Benefits - • Limited Lifetime Warranty • Lower Cost of Ownership • Peak Power Capability • Lower cost, smaller size • High Efficiency • Easier system cooling, less power used ## **Specifications** |ITEMS|**MODEL**|**MODEL**||**HWS300P**|**HWS300P**|||**HWS600P**|**HWS600P**| |---|---|---|---|---|---|---|---|---|---| |Input Voltage range|||-|||85 - 265VAC (47 - 63Hz) or 120 - 330VDC|||| |Input Current (Typ)|(1)||A|3.6/1.9||||7.2/3.7|| |Inrush Current|(1)||A|||20 / 40|||| |Power Factor|||-|||Meets EN61000-3-2|||| |Temperature Coefficient|||-|||<0.02%/°C|||| |Overcurrent Protection|||-|See table on page 2 (Recycle AC or remote on/off to reset)||||See table on page 2 (Recycle AC or remote on/off to reset)|| |Overvoltage Protection|||V|See table on page 2 (Recycle AC or remote on/off to reset)||||See table on page 2 (Recycle AC or remote on/off to reset)|| |Hold Up Time (Typ)|||ms|||20|||| |Efficiency|(1)||%|||84 / 87|||| |Leakage Curr. (@240VAC, 60Hz)|||mA|||<0.75mA (Typically 0.2mA at 100VAC)|<0.75mA (Typically 0.2mA at 100VAC)||| |Remote Sense|||-|||No|||| |Indicator|||-|||Green LED = ON|||| |Remote on/off|||-|||Yes|||| |Line Regulation|||mV|||24V: 96mV, 36V: 144mV, 48V: 192mV|||| |Load Regulation|||mV|||24V: 144mV, 36V: 216mV, 48V: 288mV|||| |Ripple & Noise|||mV|||24V: 150mV, 36V: 200mV, 48V: 350mV|||| |Parallel operation|||-|No||||Yes, up to 2 units|| |DC Good|||-|||Yes|||| |Operating Temperature|||-|-10°C to +70°C, derate linearly to 50% load from 50°C to 70°C|||-10°C to +70°C, derate linearly to 50% load from 50°C to 70°C||-10°C to +70°C, derate linearly to 50% load from 50°C to 70°C| |Storage Temperature|||-|||-30°C to +85°C|||| |Humidity (non condensing)|||-|||Operating: 10 - 90%RH, Non operating 10 - 95%RH|||| |Cooling|||-|||Internal fan|||| |Withstand Voltage|||-|Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.|Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.||||| |Isolation Resistance|||-|>100MΩat 25°C & 70%RH, Output to Ground 500VDC|||||| |Vibration (non operating)|||-|10 - 55Hz (1 minute sweep), 19.6m/s||10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour|||constant X, Y, Z 1 hour| |Shock|||-|||< 196.1 m/s2|||| |Safety Agency Certification|||-|IEC/EN/UL/CSA 60950-1 and 62368-1, EN50178, CE Mark|||IEC/EN/UL/CSA 60950-1 and 62368-1, EN50178, CE Mark|IEC/EN/UL/CSA 60950-1 and 62368-1, EN50178, CE Mark|| |Line Dip|||-|||Complies with SEMI F47 (200VAC line only)|||| |Conducted & Radiated EMI|||-|||EN55011 / EN55022, FCC VCCI Class B|||| |Immunity|||-||IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11|||IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11|| |Weight (Typ)|||g|1,000|||||1,600| |Size (WxHxD)|||mm|61 x 82 x 165||||100 x 82 x 165|| |Warranty|||-|||LimitedLifetime Warranty|||| **Notes:** (1) 100/200VAC HWS300P & 600P Series **1** ## **Model Selector** |**Model**|**Voltage**|**Adjust**<br>**Range**|**Max Avg.**<br>**Current**|**Max Avg.**<br>**Power**|**Peak**<br>**Current A**|**Max Peak**<br>**Power W**|**Overcurrent**<br>**Minimum**|**Overvoltage**| |---|---|---|---|---|---|---|---|---| ||**V**|**V**|**A**|**W**|**(1,2)**|**(1)**|**A**|**V**| |HWS300P-24|24V|19.2 - 26.4|12.5|300|21 / 42|504 / 1008|21.4 / 42.8|27.6 - 32.4| |HWS600P-24|24V|19.2 - 26.4|25|600|40.5 / 83|972 / 1992|41.3 / 84.6|27.6 - 32.4| |HWS300P-36|36V|28.8 - 39.6|8.4|302.4|14 / 28|504 / 1008|14.3 / 28.6|41.4 - 48.6| |HWS600P-36|36V|28.8 - 39.6|16.7|601.2|27 / 55.5|972 / 1998|27.5 / 56.6|41.4 - 48.6| |HWS300P-48|48V|38.4 - 52.8|6.3|302.4|10.5 / 21|504 / 1008|10.7 / 21.4|55.2 - 64.8| |HWS600P-48|48V|38.4 - 52.8|12.5|600|20 / 41.5|960 / 1992|20.4 / 42.3|55.2 - 64.8| **Notes** (1) 100/200VAC (2) 200-265VAC Input, 5s maximum on time up to 35% duty cycle (see instruction manual) ## Outline Drawing HWS300P ## Outline Drawing HWS600P **==> picture [299 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> i l ls= ‘gf - K 1 °, SS O c n o<br>wo e Bute<br>ai e nies el 7 .7) ( 83 Amax Peak Power)OUTPUT : 24 V 25 A@ SENAMEPLATNOE EA ‘SEE NOTESEEANOTE 8 AIR F LOW > NAME PLATE DETAILS<br>| + ff }<br>v texo0 TOO.loro = _ - — 2 (15 Amax@Peak Power) 50 / 60Hz ‘HWS60OP ( 83 Amax@Peak Power)OUTPUT : 24 V 25 AINPUT : 100-240VAC 8.7 A a -(28)<br>PUTES UBryiF PREXORSsseseseseseseORORO RCS eeTOTO. l S “|Ie] = @ jf 2a Ee] pg ~ = PCNCTOGTOG28 CN1COMNCCNTPF17 A. ToikLamice |<br>Sn esecece)iainin t i | a MOENHEAEL<br>lidlio]10 H cio 18 MAX | —S—ee as 4 ( 83 Amax Peak Power)OUTPUT : 24 V 25 A@ -<br>(88.8) vol_ \ \ M 4 testi (Fees |<br>T w | 20 L0#08<br>ir [ ti“‘CSOCSCSCSC‘*<br>C d ——=7—r— = 7 J}<br>Fr| _Il e ¢| |<br>T mn<br>4 dl 3i<br>(lj<br>— o S<br>5 MAK<br>HWS300P & 600P Series<br>87 TOGPF TOGCNT NCNC PCCOM 21 CN1 ( 83 Amax@Peak Power) OUTPUT : 24 V 25 A ( 15 Amax@Peak Power) 50 / 60Hz INPUT : 100-240VAC 8.7 A<br>**----- End of picture text -----**<br> **2** ## HWS300P Peak Output Power vs. Duty Cycle **==> picture [324 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> AC100V<br>Peak output power v.s. Duty AC200V<br>50<br>45 COC<br>40<br>Se<br>35<br>30 CEEEEREEEEEEEEEE<br>HWS300P<br>25 PT dE PT PAT TT ET TT<br>20 Pi ty TP INT TE ET tT<br>15<br>10<br>SR<br>5<br>0 FEREEE<br>300 400 500 600 EE 700 EEE 800 EEE 900 1000 1100<br>Peak output power [W]<br>Duty [ % ]<br>**----- End of picture text -----**<br> ## HWS600P Peak Output Power vs. Duty Cycle **==> picture [320 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> AC100V<br>Peak output power v.s. Duty AC200V<br>50<br>45 Pt TT dP dP TdT PP TT | yt<br>40 Pi} TT tt EE TT | yt<br>35 Pi Tt TT TT PP | EE<br>30 PP RUT LT ENT eT<br>HWS600P<br>25 Pt det TP | P| NET ET TT<br>ee ee<br>20<br>15<br>10 CEPR<br>EEEER SEE<br>5<br>0 EEREEEEEEE<br>600 800 1000 1200 1400 1600 EE 1800 ER 2000<br>Peak output power [W]<br>Duty [ % ]<br>**----- End of picture text -----**<br> ## **Options** Suffix Description Blank HWS300-1500 cover is fitted as standard /A Not applicable HWS300P & 600P Series **3** ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr.powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **Italy Sales Office** Tel: +39 02 61 29 38 63 tlf.it.powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en tlf.nl.powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Germany GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at.powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch.powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **Nordic Sales Office** ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com Tel: +45 8853 8086 tlg.dk.powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit https://product.tdk.com/en/power/ HWS300P&600P Mar20 v6 HWS300P & 600P Series **4**
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →