HWS150A-3/A
POWER SUPPLY, AC-DC, 3.3V, 30A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: HWS Series
- No. of Outputs: 1Outputs
- Output Power Max: 150W
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 30A
- Output Voltage - Output 1: 3.3V
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 185.89 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HWS15A-150A Series** **www.** emea.tdk-lambda.com/hws-a co ~~e~~ **Single OutputIndustrial Power Supplies** LED Industrial 19Test Comm __ Broadcast **Features Benefits** • Limited Lifetime Warranty • Lower Cost of Ownership • High Efficiency (up to 91%) • Easier System Cooling • Wide Range AC Input • Supports Global Use ~~DI~~ E **Specification Model HWS15A/A HWS30A/A HWS50A/A HWS100A/A HWS150A/A** Input Voltage Range - 85 - 265VAC (47 - 63Hz) Withstands 300VAC for 5s or 120 - 370VDC* Input Current (Typ) **(1)** A 0.35 / 0.2 0.65 / 0.4 0.65 / 0.35 1.3 / 0.65 1.9 / 0.95 Inrush Current **(1)** A 14 / 28 Meets EN61000-3-2 Power Factor - - - 0.97/0.91 0.98/0.93 0.98/0.93 Temperature Coefficient %/°C <0.02%/°C Overcurrent Protection % >105% Overvoltage Protection V Yes (see table) Hold Up Time (Typ) ms 20 Leakage Current (max) mA <0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC) Remote Sense - No Yes Indicator - Green LED = ON Operating Temperature (with cover) °C -10°C to +70°C, derate from 50°C to 70°C[(2)] Storage Temperature °C -30 to +85°C Humidity (non condensing) %RH Operating: 30 - 90%RH, Non operating 10 - 95%RH Cooling - Convection Withstand Voltage VAC Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance M Ω >100M at 25°C & 70%RH, Output to Ground 500VDC Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s[2] constant X, Y, Z 1 hour Shock m/s[2] < 196.1 m/s[2] Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark Line Dip - Complies with SEMI F47 (200VAC line only) Conducted & Radiated EMI - EN55011 / EN55022-B, FCC-B, VCCI-B Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2 Weight (Typ) g 190 240 300 470 520 Size (HxWxD) (with cover) mm 31.5 x 82 x 80 31.5 x 82 x 95 31.5 x 82 x 120 33 x 82 x 160 42 x 82 x 160 MTBF **(3)** hours 12,116,851 8,169,868 3,726,622 2,963,512 2,676,081 Warranty - Limited Lifetime Warranty (See TDK-Lambda’s terms and conditions) ~~=~~ **Notes** : * Safety certified for AC input only **(1)** 100/200VAC. **(2)** Derating varies with model. Please refer to individual model specification for derating graphs. **(3)** According to Telcordia document SR-332, issue 3, “Reliability Prediction Procedure for Electronic Equipment” Conditions: ambient temp. 25deg C, 230Vac input, full load (figures shown for 24V models) HWS15A-150A Series 1 **==> picture [517 x 34] intentionally omitted <==** ## **Model Selector** |**Model**|**Voltage**|**Adjust**<br>**Range**|**Max**<br>**Current**|**Load**<br>**Reg**|**Line**<br>**Reg**|**Ripple**<br>**Noise**|**Over**<br>**Voltage**|**Effciency**| |---|---|---|---|---|---|---|---|---| ||**(V)**|**(V)**|**(A)**|**(mV)**|**(mV)**|**(mV)**|**(V)**|**(typ) %**| |HWS15A-3/A|3.3V|2.97 - 3.96|3|40|20|120|4.13-4.95|70/71| |HWS30A-3/A|3.3V|2.97 - 3.96|6|40|20|120|4.13-4.95|75/77| |HWS50A-3/A|3.3V|2.97 - 3.96|10|40|20|120|4.13-4.95|76/78| |HWS100A-3/A|3.3V|2.97 - 3.96|20|40|20|120|4.13-4.95|82/84| |HWS150A-3/A|3.3V|2.97 - 3.96|30|40|20|120|4.13-4.95|82/84| |HWS15A-5/A|5V|4.0 - 6.0|3|40|20|120|6.25-7.25|77/79| |HWS30A-5/A|5V|4.0 - 6.0|6|40|20|120|6.25-7.25|80/82| |HWS50A-5/A|5V|4.0 - 6.0|10|40|20|120|6.25-7.25|82/84| |HWS100A-5/A|5V|4.0 - 6.0|20|40|20|120|6.25-7.25|84/86| |HWS150A-5/A|5V|4.0 - 6.0|30|40|20|120|6.25-7.25|85/87| |HWS15A-12/A|12V|9.6 - 14.4|1.3|96|48|150|15-17.4|80/83| |HWS30A-12/A|12V|9.6 - 14.4|2.5|96|48|150|15-17.4|84/86| |HWS50A-12/A|12V|9.6 - 14.4|4.3|96|48|150|15-17.4|83/85| |HWS100A-12/A|12V|9.6 - 14.4|8.5|96|48|150|15-17.4|86/88| |HWS150A-12/A|12V|9.6 - 14.4|13|96|48|150|15-17.4|85/88| |HWS15A-15/A|15V|12.0 - 18.0|1|120|60|150|18.8-21.8|81/84| |HWS30A-15/A|15V|12.0 - 18.0|2|120|60|150|18.8-21.8|85/87| |HWS50A-15/A|15V|12.0 - 18.0|3.5|120|60|150|18.8-21.8|83/86| |HWS100A-15/A|15V|12.0 - 18.0|7|120|60|150|18.8-21.8|86/88| |HWS150A-15/A|15V|12.0 - 18.0|10|120|60|150|18.8-21.8|86/89| |HWS15A-24/A|24V|19.2 - 28.8|0.65|150|96|150|30-34.8|82/85| |HWS30A-24/A|24V|19.2 - 28.8|1.3|150|96|150|30-34.8|86/88| |HWS50A-24/A|24V|19.2 - 28.8|2.2|150|96|150|30-34.8|84/87| |HWS100A-24/A|24V|19.2 - 28.8|4.5|150|96|150|30-34.8|87/89| |HWS150A-24/A|24V|19.2 - 28.8|6.5|150|96|150|30-34.8|88/90| |HWS15A-48/A|48V|38.4 - 52.8|0.33|240|192|200|55.2-64.8|80/80| |HWS30A-48/A|48V|38.4 - 52.8|0.65|240|192|200|55.2-64.8|82/83| |HWS50A-48/A|48V|38.4 - 52.8|1.1|240|192|200|55.2-64.8|84/86| |HWS100A-48/A|48V|38.4 - 52.8|2.1|240|192|200|55.2-64.8|88/90| |HWS150A-48/A|48V|38.4 - 52.8|3.3|240|192|200|55.2-64.8|89/91| |**Options**|| |---|---| |**Suffx**|**Description**| |**Blank**|No Cover| |**/ A**|Cover| |**/ R**|Remote on/off| ||(available 50W, 100W &150W models)| |**/ HD**|See HWS/HD datasheet for details.| ||-40˚C start up and PCB coating**(not available on HWS15A)**| |**/ ME**|See HWS/ME datasheet for details of available models| ||IEC/EN60601-1 medical approval**(not available on HWS15A**)| HWS15A-150A Series 2 ## **HWS15A/A Outline Drawing** ## **HWS30A/A Outline Drawing** HWS15A-150A Series 3 ## **HWS50A/A Outline Drawing** ## **HWS100A/A Outline Drawing** HWS15A-150A Series 4 **HWS150A/A Outline Drawing** HWS15A-150A Series 5 ## **TDK-Lambda France SAS** ZAC des Delaches CS 41077 9 rue Thuillere 91978 Villebon Courtaboeuf France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com ## **Italy Sales Office** Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com ## **TDK-Lambda UK Ltd.** Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com ## **TDK-Lambda Ltd.** Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il ## **Netherlands** info@nl.tdk-lambda.com www.nl.tdk-lambda.com ## **C.I.S.** ## **Commercial Support:** Tel: +7 (495) 665 2627 **Technical Support:** ## **TDK-Lambda Germany GmbH** Tel: +7 (812) 658 0463 info@tdk-lambda.ru Karl-Bold-Strasse 40 info@tdk-lambda.ru 77855 Achern www.tdk-lambda.ru Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com **Local Distribution** CO ## **Austria Sales Office** Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com ## **Switzerland Sales Office** Bahnhofstrasse 50 8305 Dietlikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@de.tdk-lambda.com www.de.tdk-lambda.com **www.emea.tdk-lambda.com** HWS-A Aug16 v9 HWS15A-150A Series 6
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →