HWS1000-24/ME
AC/DC POWER SUPPLY, ITE, 24VDC, 46A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Power Supply Applications:ITE & Medical; No. of Outputs:1Outputs; Output Power Max:1.104kW; Output Voltage - Output 1:24VDC; Output Current - Output 1:46A; Output 41R6032
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 1260.63 € |
| Current stock | 10+ |
| Lead time | 30 days |
HWS30-1500/ME Series https://product.tdk.com/en/power/hws-me www.emea.lambda.tdk.com/hws-me 30-1500W Single Output Medical Power Supplies The ultra reliable, conservatively rated HWS/ME series of 30W to 1500W AC-DC power supplies has a limited lifetime warranty[(1)] , unique to the industry. Based on the HWS-A and HWS series, they accept a wide range 85 to 265Vac input with output voltages from 5V to 60V. The series is certified to IEC 60601-1 (basic insulation) for use in non-surgical medical equipment and analyser applications. The HWS/ME also has a peak power capability (select models) and meet conducted and radiated emission standards without additional filtering or shielding. |**Features**|**Benefits**| |---|---| |• Wide Operating Temperature Range|• Operation in Harsh Environments| |• Limited Lifetime Warranty(1)|• Low Cost of Ownership| |• Very Conservative Electrolytic Capacitor Ratings|• Long Service Life| |• Peak Power Capability (Select Models)|• Supports Capacitive and Inductive Loads| ## **Model Selector** ||Output|Adjustment|Maximum|Maximum|Load|Line|Ripple||Efficiency| |---|---|---|---|---|---|---|---|---|---| |Model|Voltage|Range|Current|Power|Reg|Reg|Noise|Overvoltage|(115/230Vac)| ||(V)|(V)|(A)|(W)|(mV)|(mV)|(mV)|(V)|(%)| |HWS30A-5/ME|5|4.0 - 6.0|6|30|40|20|120|6.25 - 7.25|80 / 82| |HWS50A-5/ME|5|4.0 - 6.0|10|50|40|20|120|6.25 - 7.25|82 / 84| |HWS100A-5/ME|5|4.0 - 6.0|20|100|40|20|120|6.25 - 7.25|84 / 86| |HWS150A-5/ME|5|4.0 - 6.0|30|150|40|20|120|6.25 - 7.25|85 / 87| |HWS600-5/ME|5|4.0 - 6.0|120|600|30|20|120|6.25 - 7.25|80 / 83| |HWS30A-12/ME|12|9.6 - 14.4|2.5|30|96|48|150|15.0 - 17.4|84 / 86| |HWS50A-12/ME|12|9.6 - 14.4|4.3|51.6|96|48|150|15.0 - 17.4|83 / 85| |HWS100A-12/ME|12|9.6 - 14.4|8.5|102|96|48|150|15.0 - 17.4|86 / 88| |HWS150A-12/ME|12|9.6 - 14.4|13|156|96|48|150|15.0 - 17.4|85 / 88| |HWS300-12/ME|12|9.6 - 14.4|27|324|72|48|150|15.0 - 17.4|80 / 83| |HWS600-12/ME|12|9.6 - 14.4|53|636|72|48|150|15.0 - 17.4|80 / 83| |HWS30A-15/ME|15|12.0 - 18.0|2|30|120|60|150|18.8 - 21.8|85 / 87| |HWS50A-15/ME|15|12.0 - 18.0|3.5|52.5|120|60|150|18.8 - 21.8|83 / 86| |HWS100A-15/ME|15|12.0 - 18.0|7|105|120|60|150|18.8 - 21.8|86 / 88| |HWS150A-15/ME|15|12.0 - 18.0|10|150|120|60|150|18.8 - 21.8|86 / 89| |HWS300-15/ME|15|12.0 - 18.0|22|330|90|60|150|18.8 - 21.8|80 / 83| |HWS600-15/ME|15|12.0 - 18.0|43|645|90|60|150|18.8 - 21.8|81 / 84| |HWS30A-24/ME|24|19.2 - 28.8|1.3|31.2|150|96|150|30.0 - 34.8|86 / 88| |HWS50A-24/ME|24|19.2 - 28.8|2.2|52.8|150|96|150|30.0 - 34.8|84 / 87| |HWS100A-24/ME|24|19.2 - 28.8|4.5|108|150|96|150|30.0 - 34.8|87 / 89| |HWS150A-24/ME|24|19.2 - 28.8|6.5|156|150|96|150|30.0 - 34.8|88 / 90| |HWS300-24/ME|24|19.2 - 28.8|14 (16.5 pk)(2)336 (396 pk)|336 (396 pk)(2)|144|96|150|30.0 - 34.8|82 / 85| |HWS600-24/ME|24|19.2 - 28.8|27 (31 pk)(2)648 (744 pk)|648 (744 pk)(2)|144|96|150|30.0 - 34.8|82 / 85| |HWS1000-24/ME|24|19.2 - 28.8<br>4.8 - 28.8(4)|46 (58.5 pk)(2)|1104<br>1404 pk(2)|150|96|150|30.0 - 34.8|85 / 87| |HWS1500-24/ME|24|19.2 - 28.8<br>4.8 - 28.8(4)|65/70(3)<br>(105 pk(2))|1560/1680(3)<br>2520 pk(2)|144|96|200|30.0 - 34.8|84 / 88| |HWS1000-36/ME|36|28.8 - 43.2<br>7.2 - 43.2(4)|30.7 (39 pk(2))|1104<br>1404 pk(2)|150|144|200|45.0 - 49.7|85 / 88| |HWS1500-36/ME<br>|36|28.8 - 43.2<br>7.2 - 43.2(4)|42/46.5(3)<br>(70 pk)(2)|1512/1674(3)<br>2520 pk(2)|150|144|200|45.0 - 49.7|84 / 88| |HWS30A-48/ME|48|38.4 - 52.8|0.65|31.2|240|192|200|55.2 - 64.8|86 / 87| HWS30-1500/ME Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**| |---|---|---|---|---|---|---|---|---|---|---|---| |Output<br>Adjustment<br>Maximum<br>Maximum<br>Load<br>Line<br>Ripple<br>Effciency<br>Model<br>Voltage<br>Range<br>Current<br>Power<br>Reg<br>Reg<br>Noise<br>Overvoltage<br>(115/230Vac)<br>(V)<br>(V)<br>(A)<br>(W)<br>(mV)<br>(mV)<br>(mV)<br>(V)<br>(%)|||||||||||| |HWS50A-48/ME<br>48<br>38.4 - 52.8<br>1.1<br>52.8<br>240<br>192<br>200<br>55.2 - 64.8<br>84 / 86|||||||||||| |HWS100A-48/ME<br>48<br>38.4 - 52.8<br>2.1<br>100.8<br>240<br>192<br>200<br>55.2 - 64.8<br>88 / 90|||||||||||| |HWS150A-48/ME<br>48<br>38.4 - 52.8<br>3.3<br>158.4<br>240<br>192<br>200<br>55.2 - 64.8<br>89 / 91|||||||||||| |HWS300-48/ME<br>48<br>38.4 - 52.8<br>7<br>336<br>288<br>192<br>350<br>55.2 - 64.8<br>82 / 85|||||||||||| |HWS600-48/ME<br>48<br>38.4 - 52.8<br>13<br>624<br>288<br>192<br>350<br>55.2 - 64.8<br>83 / 86|||||||||||| |HWS1000-48/ME<br>48<br>38.4 - 52.8<br>23 (29.2 pk(2))<br>1104<br>300<br>192<br>200<br>55.2 - 60.0<br>86 / 88<br>9.6 - 43.2(4)<br>1404 pk(2)|||||||||||| |HWS1500-48/ME<br>48<br>38.4 - 52.8<br>32<br>1536<br>288<br>192<br>200<br>55.2 - 64.8<br>86 / 90<br>9.6 - 43.2(4)|||||||||||| ||||||||||||| |**HWS**|**150A**|||**-**|**5**|||**/**|**/ME**||| |Series<br>Nominal power level<br>and product size<br>Output voltage<br>5, 12, 15, 24, 36, 48<br>/ME<br>HWS30A to 150A/ME models - cover is not<br>ftted as standard HWS300 to 1500/ME<br>models - cover is always ftted<br>/MEA<br>HWS50A-150A: Cover option<br>(special order)|||||||||||| |Preferred|||||||||||| |**Specifcations**|||||||||||| |Model<br>HWS30A/ME<br>HWS50A/ME||||||HWS100A/ME<br>HWS150A/ME||||HWS300/ME<br>HWS600/ME|HWS1000/ME<br>HWS1500/ME| |**Input**|||||||||||| |Input Voltage Range (Operating)||Vac|85 - 265<br>||||||||| |Nominal Input Voltage Range||Vac|100 - 240 (Note: Safety certifed for 90-264Vac)<br>||||||||| |Input Frequency||Hz|47 - 63 (Note: Safety certifed for 50/60Hz only)<br> <br>||||||||| |DC Input Voltage range||Vdc|120 - 370 (Note: Safety certifed for AC input only)|||||||120 - 330 (Note: Safety certifed for AC input only)|| |Input Current (100/200Vac)(5)||A|0.65 / 0.4<br>0.7 / 0.35|||1.3 / 0.65<br>1.9 / 0.95||||4.1 / 2.1<br>8.1 / 3.9|24-48V: 13.5 / 7.0<br>24-48V: 19 / 10.0| |Inrush Current (100/200Vac)||A|14 / 28 (Typical at cold start)|||||||20 / 40 (Typical at cold start)|| |Leakage Current (60Hz)||mA|<0.5||||||||| |Power Factor (100/200Vac)||-|N/A<br>0.97 / 0.91|||0.98 / 0.93||||0.99 / 0.95|0.98 / 0.95<br>0.98 / 0.94| |Harmonic Compliance||-|Meets IEC61000-3-2 Class A||||||||| |Hold Up Time (typ)<br>||ms|20||||||||| |Effciency||-|See model selector table||||||||| |Conducted & Radiated EMI||-|EN55011 / EN55032-B, FCC-B, VCCI-B. (HWS600, 1000 and 1500: Class A)||||||||| |Immunity||-|||||IEC60101-1-2 Edition 4. See reports on website||||| |Safety Certifcations and Markings||-|ES60601-1, EN60601, CSA-C22.2 No 60601-1:14 (C-UL) (basic insulation), CE Mark and UKCA Mark<br>(See clause 19.5DV.2 of UL60601 for equipment in proximity of patient)||||||||| HWS30-1500/ME Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---|---|---| |Model<br>HWS30A/ME<br>HWS50A/ME|||HWS100A/ME<br>HWS150A/ME|HWS300/ME<br>HWS600/ME|HWS1000/ME<br>HWS1500/ME| |**Output**|||||| |Switching Frequency|kHz|100|120|190|12-48V: 70| |Line Regulation|mV|See Model Selector Table|||| |Load Regulation|mV|See Model Selector Table|||| |External Load Capacitance (Maximum)|uF|5V: 10,000<br>12V, 15V: 5,000<br>24V: 2,000, 48V: 500|5V: 10,000<br>12V, 15V: 10,000<br>24V: 5,000, 48V: 1,000|5V; 10,000, 12V, 15V; up to 5,000<br>24V; up to 5,000, 48V; 1,000|| |Ripple & Noise<br>|-|See Model Selector Table|||| |Temperature Coeffcient|%/°C|0.02|||| |Minimum Load|-|No minimum load required|||| |Overcurrent Protection|%|>104 (>101 of peak current for peak current capable models)|||| |Overvoltage Protection|-|See model selector table. Latching (unit shutdown), cycle AC input to reset|||| |Remote Sense|-|No|Yes||| |Remote On/Off|-|No||Yes (Isolated from output)|| |Indicators|-|Green LED indicates DC is OK|||| |Parallel Operation|-|No||Single wire connection (up to 5 units)|| |**Environmental**|||||| |Operating Temperature|°C|-10 to +70, derate linearly to 50% load from 50 to 70(6)|||| |Storage Temperature|°C|-30 to +85|||| |Humidity (non condensing)|%RH|Operating: 30 - 90, Non operating 10 - 95||Operating: 10 - 90, Non operating 10 - 95|| |Cooling|-|Convection||Internal fan|| |Altitude|m|4,000||3,000|| |Withstand Voltage (For 1 minute)|Vac|Input to ground 2,000 (HWS300-600 2,500), 1xMOOP<br>Input to output 3,000, 2xMOOP<br>Output to ground 500|||| |Isolation Resistance|MΩ|>100 at 25°C, 70%RH & 500Vdc|||| |Vibration (Non-operating)|-|10 - 55Hz (1 min sweep), 19.6m/s2constant, X, Y, Z axis, one hour each|||| |Shock (Non-operating)|-|<196.1m/s2|||| |**Other**|||||| |Weight (Typ)|g|240<br>470<br>1,000<br>3,200<br>300<br>520<br>1,600<br>3,800|||| |Size (WxHxD)|mm|26.5 x 82 x 95<br>28 x 82 x 160<br>61 x 82 x 165<br>126.5 x 82 x 240<br>26.5 x 82 x 120<br>37 x 82 x 160<br>100 x 82 x 165<br>126.5 x 82 x 280|||| |Size (WxHxD)|Inches|1.04 x 3.23 x 3.74<br>1.1 x 3.23 x 6.3<br>2.4 x 3.23 x 6.5<br>5 x 3.25 x 9.45<br>1.04 x 3.23 x 4.72<br>1.46 x 3.23 x 6.3<br>3.94 x 3.23 x 6.5<br>5 x 3.25 x 11|||| |Connectors|-|Screw terminals|||| |Case Material|-|Aluminum|||| |MTBF - Telcordia SR-332 issue 3*|Hours|8,169,868<br>2,963,512<br>2,145,809<br>1,087,031<br>3,726,622<br>2,676,081<br>1,998,996<br>1,152,309|||| |Warranty|Years|Limited lifetime(1)or 5 years|||| Notes: See website for detailed specifications, test methods and installation manual (1) The Americas and EMEA regions: limited lifetime warranty. Other regions: 5 years. See applicable regional terms of sale. (2) 200-265Vac input, 10s maximum on time with 35% duty cycle (3) Rating at 100 / 200Vac input (4) Using voltage programming input - see installation manual for details (5) See website for input current on 5V models (6) Input and output voltage dependent. See installation manuals for derating curves * 24V output model, 25°C ambient, full load, 230Vac input HWS30-1500/ME Series 3 ## **Outline Drawing HWS30A** ## **Outline Drawing HWS50A** HWS30-1500/ME Series 4 ## **Outline Drawing HWS100A** ## **Outline Drawing HWS150A** HWS30-1500/ME Series 5 ## **Outline Drawing HWS300** ## **Outline Drawing HWS600** HWS30-1500/ME Series 6 ## **Outline Drawing HWS1000/ME** ## **Outline Drawing HWS1500/ME** HWS30-1500/ME Series 7 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **Italy Sales Office** Tel: +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Germany GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **Nordic Sales Office** ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com Tel: +45 8853 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit https://product.tdk.com/en/power/ HWS-/ME_360064 August 19th, 2023 V1 HWS30-1500/ME Series 8
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.