Image not available
Illustrative purposes only
HTFS 800-P
Current Transducer, HTFS Series, PCB, 800A, -1.2kA to 1.2kA, 1 %, Voltage Output, 5 Vdc, M3
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:4.75V; Supply Voltage DC Max:5.25V; Current Measuring Range DC:-1.2kA to 1.2kA; Current Measuring Range AC:-1.2kA to 1.2kA; Response Time:7µs; Accuracy %:1
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 1%
- Accuracy %: 1%
- Product Range: HTFS Series
- Response Time: 7µs
- Primary Current: 800A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: 5V
- Supply Voltage DC Max: 5.25V
- Supply Voltage DC Min: 4.75V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 105°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -1.2kA to 1.2kA
- Current Measuring Range DC: -1.2kA to 1.2kA
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 22.52 € |
| Current stock | 50+ |
| Lead time | 30 days |
**I = 200-400-600-800 A PN** ## **Current Transducer HTFS 200..800-P** For the electronic measurement of currents : DC, AC, pulsed, mixed, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). All Data are given with a R ~~L~~ = 10 kΩ Sces **Electrical data** ~~Be Ad.~~ SSS ~~SSS~~ Primary nominal Primary current **Type** current rms measuring range **I** PN (A) **I** PM (A) 200 ± 300 **HTFS 200-P** 400 ± 600 **HTFS 400-P** 600 ± 900 **HTFS 600-P** 800 ± 1200 **HTFS 800-P** **V** OUT Output voltage (Analog) @ **I** P **V** REF ± (1.25 ・ **I** P/ **I** PN) V **I** P = 0 **V** REF ± 0.025 V **V** REF Reference voltage[1)] - Output voltage 1/2 **V** C ± 0.025 V **V** REF Output impedance typ. 200 Ω **V** REF Load impedance ≥ 200 kΩ **R** L Load resistance ≥ 2 kΩ **R** OUT Output internal resistance < 10 Ω **C** L Capacitive loading < 1 µF **V** C Supply voltage (± 5 %) 5 V **I** C Current consumption @ **V** C = 5 V 22 mA ## **Accuracy - Dynamic performance data** ~~Lo~~ **X** Accuracy[2) ] @ **I** PN, **T** A = 25 ° C ≤ ± 1 % of **I** PN εL Linearity error (0 .. 1.5 x **I** PN) ≤ ± 0.5 % of **I** PN **TCV** OE Temperature coefficient of **V** OE @ **I** P = 0 ≤ ± 0.3 mV/K **T** C **V** REF Temperature coefficient of **V** REF ≤ ± 0.01 %/K **TCV** OUT/ **V** REF Temperature coefficient of **V** OUT / **V** REF @ **I** P = 0 ≤ ± 0.2 mV/K **TCV** OUT Temperature coefficient of **V** OUT ≤ ± 0.05 % of reading/K **V** OM Magnetic offset voltage @ **I** P = 0, after an overload of 3 x **I** PN DC < ± 0.5 % of **I** PN t ra Reaction time @ 10 % of I PN < 3 µs **t** r Response time to 90 % of **I** PN step < 7 µs **di/dt** di/dt accurately followed > 100 A/µs **V** no Output voltage noise (DC ..10 kHz) < 15 mVpp (DC .. 1 MHz) < 40 mVpp **BW** Frequency bandwidth (- 3 dB) 3) DC .. 50 kHz **General data T** A Ambient operating temperature - 40 .. + 105 °C **T** S Ambient storage temperature - 40 .. + 105 °C _**m**_ Mass 60 g Standard EN 50178: 1997 Notes : 1) It is possible to overdrive **V** REF with an external reference voltage ## **Features** - Hall effect measuring principle - Galvanic isolation between primary and secondary circuit - Low power consumption - Single power supply +5V - Ratiometric offset - **T** A = -40..+105 °C - Fixation by M3 nuts and screws - Isolated plastic case recognized - according to UL 94-V0. ## **Advantages** - Small size and space saving - Only one design for wide current - ratings range - High immunity to external - interference. - **V** REF. IN/OUT. ## **Applications** - Forklift drives - AC variable speed drives - Static converters for DC motor - drives - Battery supplied applications - Uninterruptible Power Supplies - (UPS) - Switched Mode Power Supplies - (SMPS) - Power supplies for welding - applications. ## **Application domain** - Industrial. between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA. - 2) Excluding offset and Magnetic offset voltage. - 3) Small signal only to avoid excessive heatings of the magnetic core. Page 1/3 120201/9 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com ## **Current Transducer HTFS 200..800-P** ## **Isolation characteristics** **V** b Rated isolation voltage rms with following conditions - Over voltage category III - Pollution degree 2 - Non-uniform field |**V**d|Rms voltage for AC isolation test, 50 Hz, 1 min|2.5|kV| |---|---|---|---| |**V**e|Partial discharge extinction voltage rms @ 10pC|> 1|kV| |**V**w|Impulse withstand voltage 1.2/50 µs|4|kV| |**dCp**|Creepage distance|> 4|mm| |**dCl**|Clearance distance|> 4|mm| |**CTI**|Comparative tracking index (Group IIIa)|> 220|| |If insulated cable is used for the primary circuit, the|If insulated cable is used for the primary circuit, the| |---|---| |voltage category could be improved with the following table :|| |Cable insulation (primary)|Category| |HAR 03|300V CAT III| |HAR 05|400V CAT III| |HAR 07|500V CAT III| ## **Safety** This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 120201/9 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com ## **Dimensions HTFS 200..800-P** (in mm. 1 mm = 0.0394 inch) **==> picture [315 x 334] intentionally omitted <==** **----- Start of picture text -----**<br> Ip<br>40<br>0.5<br>16.5 33<br>1 4-d3.5<br>d22<br>5<br>4<br>1<br>4-0.25x0.5 3.5+/-1 4.5<br>7<br>Terminal Pin<br>1...+5V<br>2...0V<br>HTFS 3...Output<br>4...Vref<br>4 Vref(IN/OUT) Vref(IN/OUT)<br>3 Output Output<br>47nF 4.7nF<br>0V<br>2 0V<br>1 +5V 47nF +5V<br>d6 d5<br>20<br>33<br>16<br>26<br>3-P=2.54<br>**----- End of picture text -----**<br> ## **Required Connection Circuit** ## **Operation Principle** **==> picture [224 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> +Vc<br>Vout<br>Vref.(IN/OUT)<br>0V<br>Ip<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** ## **Remarks** - **V** OUT is positive when is positive when **I** P flows in the direction of the arrow. - General tolerance - General tolerance ± 0.2 mm **V** OUT is positive when is positive when **I** - • Fastening by 4 x M3 • Temperature of the primary conductor should not exceed (not supplied) 120°C. - • Recommended fastening torque < 2.5 Nm • Fastening & connection of secondary 4 pins 0.5 x 0.25 • Recommended PCB hole Ø 0.7 mm Page 3/3 120201/9 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →