HTB 100-TP
Current Transducer, HTB Series, PCB, 100A, -300A to 300A, 1 %, Voltage Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-300A to 300A; Current Measuring Range AC:-300A to 300A; Response Time:3µs; Accuracy
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 1%
- Accuracy %: 1%
- Product Range: HTB Series
- Response Time: 3µs
- Primary Current: 100A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: ± 12V to ± 15V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 80°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -300A to 300A
- Current Measuring Range DC: -300A to 300A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 14.96 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **Current Transducer HTB 50 .. 400 - P and HTB 50 .. 100 - TP** ## **I = 50 .. 400 A** PN For the electronic measurement of currents: DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). |**Electrical data**<br>Primary nominal Primary current Type<br>ah<br>C€<br>COMPLIANT<br>“ARRAN.<br>2002/95/EC|Primary nominal Primary current Type|||| |---|---|---|---|---| |current rms<br>measuring range||||| |**I**PN(A)<br>**I**PM(A)||||| |± 50<br>± 150<br>± 100<br>± 300|**HTB 50-P, HTB 50-TP**<br>1)<br>**HTB 100-P, HTB 100-TP**<br>1)|||| |± 150<br>± 450|**HTB 150-P**|||| |± 200<br>± 500|**HTB 200-P**|||| |± 300<br>± 600|**HTB 300-P**|||| |± 400<br>± 600|**HTB 400-P**|||| |**V**C<br>Supply voltage (± 5 %)2)||± 12 ..15|± 12 ..15|V| |**I**C<br>Current consumption||± 15|± 15|mA| |**Vd **<br>Rms voltage for AC isolation test, 50 Hz, 1 min||2.5||kV| |**R**IS<br>Isolation resistance @ 500 VDC||> 500|> 500|MW| |**V**OUT<br>Output voltage (Analog)@ ±**I**PN,**R**L<br>**R**OUT<br>Output internal resistance|L= 10kW,**T**A= 25°C|± 4<br>100||V<br>W| |**R**L<br>Load resistance||> 10|> 10|kW| |**Accuracy - Dynamic performance data**||||| |**X**<br>Accuracy @**I**PN,**T**A= 25°C (excluding offset)||< ± 1|< ± 1|% of**I**PN| |eL<br>Linearity error (0 .. ±**I**PN)<br>**V**OE<br>Electrical offset voltage @**T**A= 25°C||< ± 1<br>< ± 30|< ± 1<br>< ± 30|% of**I**PN<br>mV| |**V**OH<br>Hysteresis offset voltage @**I**P= 0;<br> after an excursion of 1 x**I**PN<br>**TCV**OETemperature coefficient of**V**OE HTB 50-(T)P||< ± 1<br>< ± 2.0|< ± 1<br>< ± 2.0|% of**I**PN<br>mV/K| |HTB 100-(T)P .. 400-P<br>**TCV**OUTTemperature coefficient of**V**OUT(% of reading)<br>**t**r<br>Response time to 90% of**I**PNstep<br>**BW**<br>Frequency bandwidth (- 3 dB)3)||< ± 1.0<br>< ± 0.1<br>< 3<br>DC .. 50||mV/K<br>%/K<br>µs<br>kHz| |**General data**||||| |**T**A<br>Ambient operating temperature<br>**T**S<br>Ambient storage temperature||- 40 .. + 80<br>- 40 .. + 85|- 40 .. + 80<br>- 40 .. + 85|°C<br>°C| |**_m_**<br>Mass<br>Standards||< 30 ( < 36)<br>EN 50178 :||g<br>EN 50178 :<br>1997| |2 pins of Ø2mm diameter are available on transducer||||| |for PCB soldering||||| ## **Features** - ●Hall effect measuring principle - ●Galvanic isolation between primary and secondary circuit - ●Isolation voltage 2500 V - ●Low power consumption - ●Wide power supply: ± 12 ..15 V - ●Primary bus bar option for 50 A and 100 A version for ease of connection ## **Advantages** - ●Small size and space saving - ●Only one design for wide current ratings range - ●High immunity to external interference. ## **Applications** - ●AC variable speed drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications ## **Application domain** - ●Industrial Notes :[1)] -TP version is equipped with a primary bus bar. - [2)] Operating at ±12V ≤ Vc < ±15V will reduce the measuring range. - [3)] Derating is needed to avoid excessive core heating at high frequency. Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 120425/12 www.lem.com ## **Current Transducer HTB 50 .. 400-P and HTB 50 .. 100-TP** ## **Isolation characteristics** |**V**d|Rms voltage for AC isolation test, 50 Hz, 1 min|2.5|kV| |---|---|---|---| |**V**e|Partial discharge extinction voltage rms @ 10pC|> 500|V| |**V**w|Impulse withstand voltage 1.2/50 µs|4|kV| |**dCp**|Creepage distance|> 4.5|mm| |**dCl**|Clearance distance|> 4.5|mm| |**CTI**|Comparative tracking index (Group IIIa)|275|| ## **Application examples** **According to EN 50178 and CEI 61010-1 standards** and following conditions : - Over voltage category III - Pollution degree 2 - Heterogeneous field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |Single isolation|300 V|300 V| |Reinforced isolation|150 V|150 V| ## **Safety** This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 120425/12 www.lem.com ## **Dimensions HTB 50 .. 400-P and HTB 50 .. 100-TP** (in mm. 1 mm = 0.0394 inch) LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 3/3 120425/12 www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →