HTA 100-S
Current Transducer, Open Loop Hall Effect, AC/DC/Pulsed, 100A, Analogue - ± 4V, ± 15V Supply
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 1%
- Product Range: HTA Series
- Primary Current: 100A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Analogue
- Supply Voltage Range: ± 15V
- Secondary Signal Type: -4V to 4V
- Current Sensor Technology: Open Loop Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -25°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 60.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer HTA 100 ... 1000-S** ## _I_ **= 100 ... 1000 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data** DC~~ ||Type|Primary nominal<br>RMS current|Primary nominal<br>RMS current|Primary current,<br>measuring range|Primary current,<br>measuring range|RoHS since<br>date code| |---|---|---|---|---|---|---| ||||_I_P N(A)||_I_P M(A)|| ||HTA 100-S||100||±300|46179| ||HTA 200-S||200||±600|46170| ||HTA 300-S||300||±900|46097| ||HTA 400-S||400||±1000|46100| ||HTA 500-S||500||±1000|46083| ||HTA 600-S||600||±1000|46222| ||HTA 1000-S||1000||±1000|46118| |_V_out<br>_R_L<br>_U_C<br>_I_C<br>_R_INS|Output voltage (Analog) @_I_P N<br>Load resistance<br>@_T_A= 0 ... +70 °C<br>@_T_A= −25 ... +85 °C<br>Supply voltage (±5 %)<br>Current consumption<br>Insulation resistance @ 500 V DC||||±4<br>> 1<br>= −25 ... +85 °C<br>> 3<br>±15<br>< 25<br>> 500|V<br>kΩ<br>kΩ<br>V<br>mA<br>> 500<br>MΩ| ## ~~**Accuracy - Dynamic performance data** DC~~ _X_ Accuracy[1)] @ _I_ P N, _T_ A = 25 °C, @±15 V ±1 % of _I_ P N _ε_ L Linearity error (0 ... ± _I_ P N) ±0.5 % _V_ O E Electrical offset voltage, @ _I_ P N = 0, _T_ A = 25 °C < ±10 mV _V_ O M Magnetic offset voltage, @ _I_ P = 0, after an overload of 3 × _I_ P N < ±10 mV _TCV_ O E Temperature coefficient of _V_ O E @ _T_ A = −25 ... +85 °C < ±1 mV/K _TCV_ out Temperature coefficient of _V_ out @ _T_ A = −25 ... +85 °C < ±0.05 %/K _t_ r Response time to 90 % of _I_ P N step[2)] < 3 µs _BW_ Frequency bandwidth (−3 dB)[3) ] DC ... 50 kHz ~~**General data** |~~ _T_ A Ambient operating temperature −25 ... +85 °C _T_ S Ambient storage temperature −25 ... +85 °C _m_ Mass 230 g Standard EN 50178: 1997[4)] ## **Features** - ●Open loop transducer using Hall effect - ●Panel mounting-Horizontal or Vertical - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Very good linearity - ●Very good accuracy - ●Low temperature drift - ●Wide frequency bandwidth - ●Very low insertion losses - ●High immunity to external interference - ●Current overload capability - ●Low power consumption. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. Notes:[1)] Excludes the electrical offset - 2) For a d _i_ /d _t_ = 50 A/µs - 3) Refer to derating curves in the technical file to avoid excessive core heating at high frequency - 4) Regarding compliance towards IEC 61000-4-3 (EN 61000-6-2 (2005)): variation of the offset between 80 MHz and 1 GHz with a field intensity of 10 [V/m]. N°74.63.34.000.4, N°74.63.44.000.4, N°74.63.46.000.4, N°74.63.48.000.4, N°74.63.50.000.4, N°74.63.52.000.4, N°74.63.60.000.4 15December2017/version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 1/3 www.lem.com ## **Current Transducer HTA 100 ... 1000-S** ||~~**Insulation characteristics**~~||| |---|---|---|---| |_U_d|RMS voltage for AC insulation test1), 50 Hz, 1 min|4.0|kV| |_Û_W|Impulse withstand voltage 1.2/50 µs|> 7.3|kV| |||Min|| |_d_Cp|Creepage distance|7.2|mm| |_d_CI|Clearance|7.2|mm| |_CTI_|Comparative Tracking Index (group IIIa)|600|| Note: 1) With the primary conductor located in the upper half of the aperture. ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category III - ●Pollution degree PD2 - ●Non-uniform field |Over voltage category III<br>Pollution degree PD2<br>Non-uniform feld||| |---|---|---| ||**EN 50178**|**IEC 61010-1**| |_d_Cp,_d_CI,_Û_W|Rated insulation voltage|Nominal voltage| |Basic insulation|600 V|600 V| |Reinforced insulation|300 V|300 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 15December2017/version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com ## **Dimensions HTA 100 ... 1000-S** (in mm) **==> picture [511 x 372] intentionally omitted <==** **----- Start of picture text -----**<br> d CI d Cp<br>I P U C<br>R M<br>U C<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance - ●Primary through-hole - ●Connection of secondary - ●Transducer fastening Vertical position Recommended fastening torque - ●Transducer fasterning Horizontal position Recommended fastening torque ±1 mm - ⌀ 32 mm Molex 5045-04A 1 hole and 1 notche ⌀ 4.6 mm 2 steel screws M4 0.75 N·m (±10 %) 2 holes ⌀ 4.6 mm 2 steel screws M4 0.75 N·m (±10 %) ## **Remarks** - _V_ out is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 90 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **Products/Product Documentation** . - ●Dynamic performances ( d _i_ /d _t_ and response time) are best with a single bar completely filling the primary hole. - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurement ...), please contact us. Page 3/3 15December2017/version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →