Image not available
Illustrative purposes only
HRPG-1000-48
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 1.008 kW, 48 VDC, 21 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:1.008kW; Output Voltage - Output 1:48V; Output Current - Output 1:21A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HRPG-1000 Series
- No. of Outputs: 1Outputs
- Output Power Max: 1.008kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 21A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 241.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HRPG - 1000 series** 1000W Single Output with PFC Function **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g **www.ID 2000000000tuv.com** @® Wi ~~4s~~ ■ Certificates ## ■ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:HRPG-1000-SPEC 2018-09-21_ **HRPG - 1000 series** 1000W Single Output with PFC Function ## **SPECIFICATION** |**HRPG-1000-12**<br>**HRPG-1000-15**<br>**HRPG-1000-24**<br>**HRPG-1000-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 7)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>12V<br>24V<br>48V<br>80A<br>42A<br>21A<br>0 ~ 80A<br>0 ~ 42A<br>0 ~ 21A<br>960W (max. 1000W for 3 sec.)<br>1008W<br>1008W<br>150mVp-p<br>200mVp-p<br>250mVp-p<br>11 ~ 14V<br>22 ~ 28V<br>46 ~ 56V<br>±2.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.99/115VAC at full load<br>14.5 ~ 16.5V<br>29 ~ 33V<br>58 ~ 65V<br>91.5%<br>93%<br>94%<br>8.5A/115VAC 5A/230VAC<br>25A/115VAC 40A/230VAC<br><1.2mA / 240VAC<br>105 ~ 135% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL62368-1, TUV EN62368-1, EAC TP TC 004 approved<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>286.6K hrs min.<br>Telcordia SR-332 (Bellcore) ; 105.8K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>218*105*63.5mm (L*W*H)<br>℃<br>℃<br>℃<br>1.53Kg;8pcs/13.3Kg/1.34CUFT<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024, EN61000-6-2<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 4, 2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>15V<br>64A<br>0 ~ 64A<br>960W (max. 1000W for 3 sec.)<br>150mVp-p<br>14 ~ 17V<br>±1.5%<br>±0.5%<br>±1.5%<br>18.2 ~ 20.6V<br>92%<br>**5V STANDBY**<br>5VSB : 5V@0.3A ; tolerance<br>5%, ripple : 50mVp-p(max.)<br>±<br>**FAN CONTROL**<br>Fan on/off by NTC(RT50) or 30% load min.<br>**CURRENT SHARING**<br>Up to 4000W or (3+1) units. Please refer to the Function Manual.<br>**DC-OK SIGNAL**<br>**REMOTE ON-OFF CONTROL**<br>Power ON : short; Power OFF : open. Please refer to the Function Manual.<br>The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the Function Manual.<br>**REMOTE SENSE**<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) open.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**HRPG-1000-12**<br>**HRPG-1000-15**<br>**HRPG-1000-24**<br>**HRPG-1000-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 7)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>12V<br>24V<br>48V<br>80A<br>42A<br>21A<br>0 ~ 80A<br>0 ~ 42A<br>0 ~ 21A<br>960W (max. 1000W for 3 sec.)<br>1008W<br>1008W<br>150mVp-p<br>200mVp-p<br>250mVp-p<br>11 ~ 14V<br>22 ~ 28V<br>46 ~ 56V<br>±2.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.99/115VAC at full load<br>14.5 ~ 16.5V<br>29 ~ 33V<br>58 ~ 65V<br>91.5%<br>93%<br>94%<br>8.5A/115VAC 5A/230VAC<br>25A/115VAC 40A/230VAC<br><1.2mA / 240VAC<br>105 ~ 135% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL62368-1, TUV EN62368-1, EAC TP TC 004 approved<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>286.6K hrs min.<br>Telcordia SR-332 (Bellcore) ; 105.8K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>218*105*63.5mm (L*W*H)<br>℃<br>℃<br>℃<br>1.53Kg;8pcs/13.3Kg/1.34CUFT<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024, EN61000-6-2<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 4, 2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>15V<br>64A<br>0 ~ 64A<br>960W (max. 1000W for 3 sec.)<br>150mVp-p<br>14 ~ 17V<br>±1.5%<br>±0.5%<br>±1.5%<br>18.2 ~ 20.6V<br>92%<br>**5V STANDBY**<br>5VSB : 5V@0.3A ; tolerance<br>5%, ripple : 50mVp-p(max.)<br>±<br>**FAN CONTROL**<br>Fan on/off by NTC(RT50) or 30% load min.<br>**CURRENT SHARING**<br>Up to 4000W or (3+1) units. Please refer to the Function Manual.<br>**DC-OK SIGNAL**<br>**REMOTE ON-OFF CONTROL**<br>Power ON : short; Power OFF : open. Please refer to the Function Manual.<br>The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the Function Manual.<br>**REMOTE SENSE**<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) open.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**HRPG-1000-12**|**HRPG-1000-15**|**HRPG-1000-15**|**HRPG-1000-24**|**HRPG-1000-24**|**HRPG-1000-48**| |---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|12V|15V||24V||48V| ||**RATED CURRENT**|80A|64A||42A||21A| ||**CURRENT RANGE**|0 ~ 80A|0 ~ 64A||0 ~ 42A||0 ~ 21A| ||**RATED POWER**|960W (max. 1000W for 3 sec.)|960W (max. 1000W for 3 sec.)||1008W||1008W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|150mVp-p||200mVp-p||250mVp-p| ||**VOLTAGE ADJ. RANGE**|11 ~ 14V|14 ~ 17V||22 ~ 28V||46 ~ 56V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.5%||±1.0%||±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%||±0.5%||±0.5%| ||**LOAD REGULATION**|±2.0%|±1.5%||±0.5%||±0.5%| ||**SETUP, RISE TIME**|1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load|||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**POWER FACTOR (Typ.)**|PF>0.95/230VAC PF>0.99/115VAC at full load|||||| ||**EFFICIENCY (Typ.)**|91.5%|92%||93%||94%| ||**AC CURRENT (Typ.)**|8.5A/115VAC 5A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|25A/115VAC 40A/230VAC|||||| ||**LEAKAGE CURRENT**|<1.2mA / 240VAC|||||| ||**OVERLOAD**|105 ~ 135% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed|||||| ||**OVER VOLTAGE**|14.5 ~ 16.5V<br>29 ~ 33V<br>58 ~ 65V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>18.2 ~ 20.6V|||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||| ||**CURRENT SHARING**|Up to 4000W or (3+1) units. Please refer to the Function Manual.|||||| ||**REMOTE ON-OFF CONTROL**|Power ON : short; Power OFF : open. Please refer to the Function Manual.|||||| ||**REMOTE SENSE**|Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.|||||| ||**DC-OK SIGNAL**|The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the Function Manual.|||||| ||**5V STANDBY**|5VSB : 5V@0.3A ; tolerance<br>5%, ripple : 50mVp-p(max.)<br>±|||||| ||**FAN CONTROL**|Fan on/off by NTC(RT50) or 30% load min.|||||| ||**WORKING TEMP.**|-40 ~ +70<br>(Refer to "Derating Curve")<br>℃|||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1, EAC TP TC 004 approved|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**||**Standard**||**Test Level / Note**|| |||Conducted||EN55032 (CISPR32) / EN55011 (CISPR11)||Class B|| |||Radiated||EN55032 (CISPR32) / EN55011 (CISPR11)||Class B|| |||Harmonic Current||EN61000-3-2||Class A|| |||Voltage Flicker||EN61000-3-3||-----|| |||EN55024, EN61000-6-2|||||| |||**Parameter**||**Standard**||**Test Level / Note**|| |||ESD||EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact|| |||Radiated||EN61000-4-3||Level 3|| |||EFT / Burst||EN61000-4-4||Level 3|| |||Surge||EN61000-4-5||Level 4, 2KV/Line-Line 4KV/Line-Earth|| |||Conducted||EN61000-4-6||Level 3|| |||Magnetic Field||EN61000-4-8||Level 4|| |||Voltage Dips and Interruptions||EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| |||286.6K hrs min.<br>Telcordia SR-332 (Bellcore) ; 105.8K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||||| ||**DIMENSION**|218*105*63.5mm (L*W*H)|||||| ||**PACKING**<br>℃<br>℃<br>℃<br>1.53Kg;8pcs/13.3Kg/1.34CUFT<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) open.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).||||||| ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating _File Name:HRPG-1000-SPEC 2018-09-21_ ## 1000W Single Output with PFC Function ## **HRPG - 1000 series** ## **Block Diagram** **==> picture [496 x 385] intentionally omitted <==** **----- Start of picture text -----**<br> PFC : 65KHz<br>PWM : 90KHz<br>AUX RECTIFIERS AUX<br>&<br>POWER AUXG<br>FILTER<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>-S<br>DETECTION<br>O.T.P. O.L.P. CIRCUIT DC OK<br>FG<br>O.T.P.<br>PFC PWM O.V.P. CURRENT CS<br>CONTROL CONTROL SHARING<br>REMOTE RC+<br>CONTROL RC-<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100 24V,48V<br>90<br>80<br>80<br>60 70<br>12V,15V<br>60<br>40<br>50<br>20<br>40<br>-40 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 200 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD(%)<br>**----- End of picture text -----**<br> _File Name:HRPG-1000-SPEC 2018-09-21_ **HRPG - 1000 series** 1000W Single Output with PFC Function ## **Function Description of CN100** **==> picture [472 x 613] intentionally omitted <==** **----- Start of picture text -----**<br> Pin No. Function Description<br>1 AUXG Auxiliary voltage output ground.<br>Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the<br>2 AUX<br>"remote ON/OFF control".<br>3 RC+ Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power ON, Open: Power OFF.<br>4 RC- Remote control ground.<br>Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance<br>5 CS<br>between units.<br>6,8 GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.<br>7 DC-OK DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on.<br>Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to<br>9 +S<br>minimize noise pick-up effect. The maximum line drop compensation is 0.5V.<br>Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to<br>10 -S<br>minimize noise pick-up effect. The maximum line drop compensation is 0.5V.<br>Function Manual<br>1.Remote Sense<br>The remote sensing compensates voltage drop on the load wiring up to 0.5V.<br>CN100<br>2 1<br>10 9<br>+V<br>LOAD<br>-V<br>Sense lines should<br>be twisted in pairs<br>Fig 1.1<br>2.DC-OK Signal<br>DC-OK signal is a TTL level signal. High when PSU turns on.<br>Between DC-OK(pin7) and GND(pin6,8) Output Status<br>3.3 ~ 5.6V ON<br>0 ~ 1V OFF<br>CN100<br>2 1<br>10 9<br>Fig 2.1<br>**----- End of picture text -----**<br> _File Name:HRPG-1000-SPEC 2018-09-21_ **HRPG - 1000 series** 1000W Single Output with PFC Function ## **3.Remote ON-OFF Control** **==> picture [395 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> The PSU can be turned ON/OFF by using the<br>"Remote Control" function.<br>Between RC+(pin3) and RC-(pin4) Output Status<br>SW ON (Short) ON SW<br>CN100<br>SW OFF (Open) OFF<br>2 1<br>10 9<br>Fig 3.1<br>**----- End of picture text -----**<br> ## **4.Current Sharing** HRPG-1000 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : - ※The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - ※ Difference of output voltages among parallel units should be less than 0.2V. - ※ The total output current must not exceed the value determined by the following equation: - Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 - ※ When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be fully balanced. **==> picture [502 x 338] intentionally omitted <==** **----- Start of picture text -----**<br> PSU1 PSU2 PSU3 PSU4<br>+V +V +V +V<br>-V -V -V -V<br>CN100 CN100 CN100 CN100<br>PSU1 PSU2 PSU3 PSU4<br>CN100 CN100 CN100 CN100<br>1 AUXG RC+ CS DC-OK +S 9 1 AUXG RC+ CS DC-OK +S 9 1 AUXG RC+ CS DC-OK +S 9 1 AUXG RC+ CS DC-OK +S 9<br>2 AUX RC- GND GND -S 10 2 AUX RC- GND GND -S 10 2 AUX RC- GND GND -S 10 2 AUX RC- GND GND -S 10<br>-V +V<br>LOAD<br>Fig 4.1<br>**----- End of picture text -----**<br> _File Name:HRPG-1000-SPEC 2018-09-21_ **HRPG - 1000 series** ## 1000W Single Output with PFC Function **==> picture [488 x 343] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 977 Unit:mm<br>152.4 32.8<br>O/P<br>1<br>4-M4 L=6<br>2<br>Air flow<br>3<br>direction<br>4<br>I/P 5<br>1 6<br>2 1 9<br>3<br>2 10<br>218<br>152.4 32.8<br>8-M4 L=4 (Both Sides) 18max.<br>12max.<br>AC Input Terminal Pin No. DC Output Terminal Pin No. Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent<br>Assignment Assignment Pin No. Assignment Pin No. Assignment Mating Housing Terminal<br>Pin No. Assignment Pin No. Assignment 1 AUXG 6,8 GND<br>1 AC/L 1~3 +V 2 AUX 7 DC-OK<br>HRS DF11-10DS HRS DF11-**SC<br>2 AC/N 4~6 -V 3 RC+ 9 +S or equivalent or equivalent<br>3 FG 4 RC- 10 -S<br>5 CS<br>CN100 LED (Vo ADJ.)SVR1<br>20.75<br>11<br>63.5 9.2 105<br>8.2<br>10<br>38.3 63.5<br>12.5<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HRPG-1000-SPEC 2018-09-21_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →