Image not available
Illustrative purposes only
HRP-600-36
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 630 W, 36 VDC, 17.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HRP-600 Series
- No. of Outputs: 1Outputs
- Output Power Max: 630W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 17.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 104.76 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **- HRP 600 series** ## MEAN WELL 600W Single Output with PFC Function **- series** ~~a~~ ## ■ ° Allusing 105 ℃ — long life electrolytic capacitors |**HRP-600-3.3**<br>**HRP-600-5**<br>**HRP-600-7.5**<br>**HRP-600-12**<br>**HRP-600-15**<br>**HRP-600-24**<br>**HRP-600-36**<br>**HRP-600-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>3.3V<br>5V<br>7.5V<br>12V<br>15V<br>24V<br>36V<br>48V<br>120A<br>120A<br>80A<br>53A<br>43A<br>27A<br>17.5A<br>13A<br>0 ~ 120A<br>0 ~ 120A<br>0 ~ 80A<br>0 ~ 53A<br>0 ~ 43A<br>0 ~ 27A<br>0 ~ 17.5A<br>0 ~ 13A<br>396W<br>600W<br>600W<br>636W<br>645W<br>648W<br>630W<br>624W<br>120mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>240mVp-p<br>2.8 ~ 3.8V<br>4.3 ~ 5.8V<br>6.8 ~ 9V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.3%<br>±0.3%<br>±0.2%<br>±0.2%<br>±0.2%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>1800ms, 50ms/230VAC 3600ms, 50ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.93/230VAC PF>0.99/115VAC at full load<br>78.5%<br>82%<br>6 ~ 7V<br>9.4 ~ 10.9V<br>14.4 ~ 16.8V<br>18.8 ~ 21.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>87%<br>88%<br>88%<br>88%<br>89%<br>89%<br>7.6A/115VAC 3.6A/230VAC<br>35A/115VAC 70A/230VAC<br><1.2mA / 240VAC<br>105 ~ 135% rated output power<br>3.96 ~ 4.62V<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>140.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>218*105*63.5mm (L*W*H)<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1.5Kg;8pcs/13Kg/1.34CUFT<br>**FUNCTION DC OK SIGNAL**<br>**FAN CONTROL (Typ.)**<br>PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V<br>Load 35<br>15% or RTH2<br>50<br>Fan on<br>≧<br>℃<br>±<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>UL62368-1, TUV EN62368-1,<br>EAC TP TC 004 approved<br>AS/NZS62368.1,<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**HRP-600-3.3**<br>**HRP-600-5**<br>**HRP-600-7.5**<br>**HRP-600-12**<br>**HRP-600-15**<br>**HRP-600-24**<br>**HRP-600-36**<br>**HRP-600-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>3.3V<br>5V<br>7.5V<br>12V<br>15V<br>24V<br>36V<br>48V<br>120A<br>120A<br>80A<br>53A<br>43A<br>27A<br>17.5A<br>13A<br>0 ~ 120A<br>0 ~ 120A<br>0 ~ 80A<br>0 ~ 53A<br>0 ~ 43A<br>0 ~ 27A<br>0 ~ 17.5A<br>0 ~ 13A<br>396W<br>600W<br>600W<br>636W<br>645W<br>648W<br>630W<br>624W<br>120mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>240mVp-p<br>2.8 ~ 3.8V<br>4.3 ~ 5.8V<br>6.8 ~ 9V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.3%<br>±0.3%<br>±0.2%<br>±0.2%<br>±0.2%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>1800ms, 50ms/230VAC 3600ms, 50ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.93/230VAC PF>0.99/115VAC at full load<br>78.5%<br>82%<br>6 ~ 7V<br>9.4 ~ 10.9V<br>14.4 ~ 16.8V<br>18.8 ~ 21.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>87%<br>88%<br>88%<br>88%<br>89%<br>89%<br>7.6A/115VAC 3.6A/230VAC<br>35A/115VAC 70A/230VAC<br><1.2mA / 240VAC<br>105 ~ 135% rated output power<br>3.96 ~ 4.62V<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>140.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>218*105*63.5mm (L*W*H)<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1.5Kg;8pcs/13Kg/1.34CUFT<br>**FUNCTION DC OK SIGNAL**<br>**FAN CONTROL (Typ.)**<br>PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V<br>Load 35<br>15% or RTH2<br>50<br>Fan on<br>≧<br>℃<br>±<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>UL62368-1, TUV EN62368-1,<br>EAC TP TC 004 approved<br>AS/NZS62368.1,<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**HRP-600-3.3**|**HRP-600-5**|**HRP-600-7.5**|**HRP-600-12**|**HRP-600-15**|**HRP-600-24**|**HRP-600-36**|**HRP-600-48**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|3.3V|5V|7.5V|12V|15V|24V|36V|48V| ||**RATED CURRENT**|120A|120A|80A|53A|43A|27A|17.5A|13A| ||**CURRENT RANGE**|0 ~ 120A|0 ~ 120A|0 ~ 80A|0 ~ 53A|0 ~ 43A|0 ~ 27A|0 ~ 17.5A|0 ~ 13A| ||**RATED POWER**|396W|600W|600W|636W|645W|648W|630W|624W| ||**RIPPLE & NOISE (max.) Note.2**|120mVp-p|150mVp-p|150mVp-p|150mVp-p|150mVp-p|150mVp-p|200mVp-p|240mVp-p| ||**VOLTAGE ADJ. RANGE**|2.8 ~ 3.8V|4.3 ~ 5.8V|6.8 ~ 9V|10.2 ~ 13.8V|13.5 ~ 18V|21.6 ~ 28.8V|28.8 ~ 39.6V|40.8 ~ 55.2V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±2.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.5%|±0.3%|±0.3%|±0.2%|±0.2%|±0.2%| ||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1800ms, 50ms/230VAC 3600ms, 50ms/115VAC at full load|||||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||||||| ||**VOLTAGE RANGE**<br>**Note.5**|85 ~ 264VAC 120 ~ 370VDC|||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||||| ||**POWER FACTOR (Typ.)**|PF>0.93/230VAC PF>0.99/115VAC at full load|||||||| ||**EFFICIENCY (Typ.)**|78.5%|82%|87%|88%|88%|88%|89%|89%| ||**AC CURRENT (Typ.)**|7.6A/115VAC 3.6A/230VAC|||||||| ||**INRUSH CURRENT (Typ.)**|35A/115VAC 70A/230VAC|||||||| ||**LEAKAGE CURRENT**|<1.2mA / 240VAC|||||||| ||**OVERLOAD**|105 ~ 135% rated output power<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed|||||||| ||**OVER VOLTAGE**|6 ~ 7V<br>9.4 ~ 10.9V<br>14.4 ~ 16.8V<br>18.8 ~ 21.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>3.96 ~ 4.62V<br>Protection type : Shut down o/p voltage, re-power on to recover|||||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||||| ||**DC OK SIGNAL**|PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V|||||||| ||<br>**FAN CONTROL (Typ.)**|Load 35<br>15% or RTH2<br>50<br>Fan on<br>≧<br>℃<br>±|||||||| ||**WORKING TEMP.**|-40 ~ +70<br>(Refer to "Derating Curve")<br>℃|||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1,<br>EAC TP TC 004 approved<br>AS/NZS62368.1,|||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||||| ||**EMC EMISSION**|Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020|||||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020|||||||| ||**MTBF**|140.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||||||| ||**DIMENSION**|218*105*63.5mm (L*W*H)|||||||| ||**PACKING**<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1.5Kg;8pcs/13Kg/1.34CUFT<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to||||||||| ## **SPECIFICATION** _File Name:HRP-600-SPEC 2020-10-20_ **- HRP 600 series** 600W Single Output with PFC Function **==> picture [484 x 637] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 977A Unit:mm<br>152.4 32.8<br>O/P<br>1<br>4-M4 L=6<br>2<br>Air flow<br>3<br>direction<br>4<br>I/P 5<br>1 6<br>2<br>3 12 34<br>218<br>152.4 32.8<br>8-M4 L=4 (Both Sides) 18max.<br>12max.<br>AC Input Terminal Pin No. DC Output Terminal Pin No. Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent<br>Assignment Assignment Pin No. Assignment Mating Housing Terminal<br>Pin No. Assignment Pin No. Assignment 1 DC-OK<br>1 AC/L 1~3 -V 2 GND HRS DF11-4DS HRS DF11-**SC<br>2 AC/N 4~6 +V 3 +S or equivalent or equivalent<br>3 FG 4 -S<br>Block Diagram<br>PWM fosc : 70KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>-S<br>O.T.P. O.L.P.<br>FG DETECTION<br>CIRCUIT DC OK<br>O.T.P.<br>PFC PWM<br>CONTROL CONTROL O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>125 100<br>90<br>100<br>80<br>80<br>70<br>50 60<br>50<br>20 40<br>-40 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD(%)<br>CN100 LED SVR1 (Vo ADJ.)<br>20.75<br>11<br>63.5 9.2 105<br>8.2<br>10<br>38.3 63.5<br>12.5<br>**----- End of picture text -----**<br> _File Name:HRP-600-SPEC 2020-10-20_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →