- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HRP-450 Series
- No. of Outputs: 1Outputs
- Output Power Max: 450W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 37.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 97.68 € |
| Current stock | 10+ |
| Lead time | 30 days |
MEAN WELL 450W Single Output with PFC Function **- series** ~~a~~ ## **- HRP 450 series** ## ■ |**HRP-450-3.3**<br>**HRP-450-5**<br>**HRP-450-7.5**<br>**HRP-450-12**<br>**HRP-450-15**<br>**HRP-450-24**<br>**HRP-450-36**<br>**HRP-450-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**DC OK SIGNAL**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>3.3V<br>5V<br>7.5V<br>12V<br>15V<br>24V<br>36V<br>48V<br>90A<br>90A<br>60A<br>37.5A<br>30A<br>18.8A<br>12.5A<br>9.5A<br>0 ~ 90A<br>0 ~ 90A<br>0 ~ 60A<br>0 ~ 37.5A<br>0 ~ 30A<br>0 ~ 18.8A<br>0 ~ 12.5A<br>0 ~ 9.5A<br>297W<br>450W<br>450W<br>450W<br>450W<br>451.2W<br>450W<br>456W<br>80mVp-p<br>80mVp-p<br>100mVp-p<br>120mVp-p<br>150mVp-p<br>150mVp-p<br>240mVp-p<br>240mVp-p<br>2.8 ~ 3.8V<br>4.3 ~ 5.8V<br>6.8 ~ 9V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.3%<br>±0.3%<br>±0.2%<br>±0.2%<br>±0.2%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.99/115VAC at full load<br>80%<br>83%<br>6 ~ 7V<br>9.4 ~ 10.9V<br>14.4 ~ 16.8V<br>18.8 ~ 21.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>86.5%<br>88%<br>89%<br>88%<br>89%<br>89.5%<br>5A/115VAC 2.4A/230VAC<br>35A/115VAC 70A/230VAC<br><1.5mA / 240VAC<br>105 ~ 135% rated output power<br>3.96 ~ 4.62V<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>139.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>218*105*41mm (L*W*H)<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1.19Kg; 12pcs/15.3Kg/0.82CUFT<br>**FAN CONTROL (Typ.)**<br>Load 20<br>10% or RTH2<br>50<br>Fan on<br>±<br>≧<br>℃<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>UL62368-1,TUV EN62368-1,<br>EAC TP TC 004 approved<br>AS/NZS62368.1,<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**HRP-450-3.3**<br>**HRP-450-5**<br>**HRP-450-7.5**<br>**HRP-450-12**<br>**HRP-450-15**<br>**HRP-450-24**<br>**HRP-450-36**<br>**HRP-450-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**DC OK SIGNAL**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>3.3V<br>5V<br>7.5V<br>12V<br>15V<br>24V<br>36V<br>48V<br>90A<br>90A<br>60A<br>37.5A<br>30A<br>18.8A<br>12.5A<br>9.5A<br>0 ~ 90A<br>0 ~ 90A<br>0 ~ 60A<br>0 ~ 37.5A<br>0 ~ 30A<br>0 ~ 18.8A<br>0 ~ 12.5A<br>0 ~ 9.5A<br>297W<br>450W<br>450W<br>450W<br>450W<br>451.2W<br>450W<br>456W<br>80mVp-p<br>80mVp-p<br>100mVp-p<br>120mVp-p<br>150mVp-p<br>150mVp-p<br>240mVp-p<br>240mVp-p<br>2.8 ~ 3.8V<br>4.3 ~ 5.8V<br>6.8 ~ 9V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.3%<br>±0.3%<br>±0.2%<br>±0.2%<br>±0.2%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.99/115VAC at full load<br>80%<br>83%<br>6 ~ 7V<br>9.4 ~ 10.9V<br>14.4 ~ 16.8V<br>18.8 ~ 21.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>86.5%<br>88%<br>89%<br>88%<br>89%<br>89.5%<br>5A/115VAC 2.4A/230VAC<br>35A/115VAC 70A/230VAC<br><1.5mA / 240VAC<br>105 ~ 135% rated output power<br>3.96 ~ 4.62V<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>139.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>218*105*41mm (L*W*H)<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1.19Kg; 12pcs/15.3Kg/0.82CUFT<br>**FAN CONTROL (Typ.)**<br>Load 20<br>10% or RTH2<br>50<br>Fan on<br>±<br>≧<br>℃<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>UL62368-1,TUV EN62368-1,<br>EAC TP TC 004 approved<br>AS/NZS62368.1,<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**HRP-450-3.3**|**HRP-450-5**|**HRP-450-7.5**|**HRP-450-12**|**HRP-450-15**|**HRP-450-24**|**HRP-450-36**|**HRP-450-48**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|3.3V|5V|7.5V|12V|15V|24V|36V|48V| ||**RATED CURRENT**|90A|90A|60A|37.5A|30A|18.8A|12.5A|9.5A| ||**CURRENT RANGE**|0 ~ 90A|0 ~ 90A|0 ~ 60A|0 ~ 37.5A|0 ~ 30A|0 ~ 18.8A|0 ~ 12.5A|0 ~ 9.5A| ||**RATED POWER**|297W|450W|450W|450W|450W|451.2W|450W|456W| ||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|80mVp-p|100mVp-p|120mVp-p|150mVp-p|150mVp-p|240mVp-p|240mVp-p| ||**VOLTAGE ADJ. RANGE**|2.8 ~ 3.8V|4.3 ~ 5.8V|6.8 ~ 9V|10.2 ~ 13.8V|13.5 ~ 18V|21.6 ~ 28.8V|28.8 ~ 39.6V|40.8 ~ 55.2V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±2.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.5%|±0.3%|±0.3%|±0.2%|±0.2%|±0.2%| ||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load|||||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||||||| ||**VOLTAGE RANGE**<br>**Note.5**|85 ~ 264VAC 120 ~ 370VDC|||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||||| ||**POWER FACTOR (Typ.)**|PF>0.95/230VAC PF>0.99/115VAC at full load|||||||| ||**EFFICIENCY (Typ.)**|80%|83%|86.5%|88%|89%|88%|89%|89.5%| ||**AC CURRENT (Typ.)**|5A/115VAC 2.4A/230VAC|||||||| ||**INRUSH CURRENT (Typ.)**|35A/115VAC 70A/230VAC|||||||| ||**LEAKAGE CURRENT**|<1.5mA / 240VAC|||||||| ||**OVERLOAD**|105 ~ 135% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed|||||||| ||**OVER VOLTAGE**|6 ~ 7V<br>9.4 ~ 10.9V<br>14.4 ~ 16.8V<br>18.8 ~ 21.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>3.96 ~ 4.62V<br>Protection type : Shut down o/p voltage, re-power on to recover|||||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||||| ||**DC OK SIGNAL**|PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V|||||||| ||**FAN CONTROL (Typ.)**|Load 20<br>10% or RTH2<br>50<br>Fan on<br>±<br>≧<br>℃|||||||| ||**WORKING TEMP.**|-40 ~ +70<br>(Refer to "Derating Curve")<br>℃|||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||||| ||**SAFETY STANDARDS**|UL62368-1,TUV EN62368-1,<br>EAC TP TC 004 approved<br>AS/NZS62368.1,|||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||||| ||**EMC EMISSION**|Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020|||||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020|||||||| ||**MTBF**|139.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||||||| ||**DIMENSION**|218*105*41mm (L*W*H)|||||||| ||**PACKING**<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1.19Kg; 12pcs/15.3Kg/0.82CUFT<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to||||||||| ## **SPECIFICATION** (as available on http://www.meanwell.com) 7. The ambient temperature derating of 3.5 ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:HRP-450-SPEC 2020-10-20_ **- HRP 450 series** 450W Single Output with PFC Function **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 995A Unit:mm<br>152.4 32.8<br>O/P<br>1<br>2<br>Air flow<br>direction FAN 3<br>4<br>I/P 5<br>1 6<br>2<br>3 4-M4 L=5 1 3<br>2 4<br>218<br>152.4 32.8<br>18max.<br>12max.<br>8-M4 L=4 (Both Sides)<br>AC Input Terminal Pin No. DC Output Terminal Pin No. Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent<br>Assignment Assignment Pin No. Assignment Mating Housing Terminal<br>Pin No. Assignment Pin No. Assignment 1 DC-OK<br>1 AC/L 1~3 -V 2 GND HRS DF11-4DS HRS DF11-**SC<br>2 AC/N 4~6 +V 3 +S or equivalent or equivalent<br>3 FG 4 -S<br>Block Diagram PWM fosc : 70KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>-S<br>O.T.P. O.L.P. DETECTION<br>FG CIRCUIT DC OK<br>PFC PWM O.T.P.<br>CONTROL CONTROL O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>125 100<br>90<br>100<br>80<br>80<br>70<br>50 60<br>50<br>20 40<br>-40 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD(%)<br>20.75<br>63.5<br>8.2<br>10<br>CN100 LED (Vo ADJ.)SVR1<br>41 18<br>11<br>9.2 105<br>12.5<br>**----- End of picture text -----**<br> _File Name:HRP-450-SPEC 2020-10-20_ **- HRP 450 series** 450W Single Output with PFC Function ## **Function Description of CN100** **==> picture [454 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> Pin No. Function Description<br>1 DC-OK DC-OK Signal is a TTL level signal, referenced to pin2(DC-OK GND). High when PSU turns on.<br>2 GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.<br>Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to<br>3 +S<br>minimize noise pick-up effect. The maximum line drop compensation is 0.5V.<br>Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to<br>4 -S<br>minimize noise pick-up effect. The maximum line drop compensation is 0.5V.<br>**----- End of picture text -----**<br> ## **Function Manual** **==> picture [479 x 297] intentionally omitted <==** **----- Start of picture text -----**<br> 1.Remote Sense CN100<br>The remote sensing compensates voltage drop on<br>the load wiring up to 0.5V. 2 1 CN100<br>4 3<br>2 GND DC-OK 1<br>4 3<br>-S +S<br>+ -<br>+S -S<br>(Pin3) LOAD (Pin4)<br>Sense lines should<br>Fig 1.1 be twisted in pairs<br>2.DC-OK Signal CN100<br>DC-OK signal is a TTL level signal. High when PSU turns on.<br>CN100<br>Between DC-OK(pin5) and GND(pin6) Output Status 2 1<br>4 3 2 1<br>GND DC-OK<br>3.3 ~ 5.6V ON<br>0 ~ 1V OFF 4 -S +S 3<br>Fig 2.1<br>**----- End of picture text -----**<br> _File Name:HRP-450-SPEC 2020-10-20_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →