Image not available
Illustrative purposes only
HRP-300N-48
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 336 W, 48 VDC, 7 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: HRP-300N Series
- No. of Outputs: 1Outputs
- Output Power Max: 336W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 83.01 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- HRP 300N series** 300W Single Output with PFC Function BauarSicherheitbeegelodwacmat geprufto ges g www.ID 2000000000tuv.com BOW **AS/NZS 62368.1** UL62368-1 ~~E~~ **EN62368-1 TPTC004** MCB **IEC62368-1** ## ■ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ## ■ ℃. **==> picture [13 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:HRP-300N-SPEC 2020-11-03_ ## 300W Single Output with PFC Function ## **- HRP 300N series** ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**||||||| |---|---|---|---|---|---|---|---| |**HRP-300N-12**<br>**HRP-300N-24**<br>**HRP-300N-36**<br>**HRP-300N-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>12V<br>24V<br>36V<br>48V<br>27A<br>14A<br>9A<br>7A<br>0 ~ 27A<br>0 ~ 14A<br>0 ~ 9A<br>0 ~ 7A<br>324W<br>336W<br>324W<br>336W<br>120mVp-p<br>150mVp-p<br>250mVp-p<br>250mVp-p<br>10.2 ~ 13.8V<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.3%<br>±0.2%<br>±0.2%<br>±0.2%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.99/115VAC at full load<br>14.4 ~ 16.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>3.5A/115VAC 1.8A/230VAC<br>35A/115VAC 75A/230VAC<br><1.5mA / 240VAC<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL62368-1, TUV EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>/℃<br>℃<br>0.03%<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>199*105*41mm (L*W*H)<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>0.9Kg;15pcs/14.5Kg/0.84CUFT<br>88%<br>87%<br>88%<br>89%<br>**DC OK SIGNAL**<br>PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V<br>**FUNCTION**<br>**FAN CONTROL (Typ.)**<br>Load 35<br>15% or RTH2<br>50<br>Fan on<br>±<br>≧<br>℃<br>529.1K hrs min.<br>Telcordia TR/SR-332 (Bellcore) ; 201.43K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Voltage Flicker<br>**Standard**<br>EN55032<br>EN55032<br>EN61000-3-3<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55035 , EN61000-6-2(EN50082-2)<br>**Parameter**<br>ESD<br>RF field<br>EFT/ Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>Level 3, 8KV air; Level 2, 4KV contact<br>Level 3, 10V/m<br>Level 3, 2KV<br>Level 4, 4KV/Line-FG; 2KV/Line-Line<br>Level 3, 10V<br>Level 4, 30A/m<br>95% dip 0.5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>EN61000-3-2<br>Harmonic current<br>Class A<br>Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power<br>Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power<br>on to recover<br>on to recover<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>Product Liability Disclaimer<br>For detailed information, please refer to||**HRP-300N-12**|**HRP-300N-24**||**HRP-300N-36**||**HRP-300N-48**| ||**DC VOLTAGE**|12V|24V||36V||48V| ||**RATED CURRENT**|27A|14A||9A||7A| ||**CURRENT RANGE**|0 ~ 27A|0 ~ 14A||0 ~ 9A||0 ~ 7A| ||**RATED POWER**|324W|336W||324W||336W| ||**RIPPLE & NOISE (max.) Note.2**|120mVp-p|150mVp-p||250mVp-p||250mVp-p| ||**VOLTAGE ADJ. RANGE**|10.2 ~ 13.8V|21.6 ~ 28.8V||28.8 ~ 39.6V||40.8 ~ 55.2V| ||**VOLTAGE TOLERANCE Note.3**|±1.0%|±1.0%||±1.0%||±1.0%| ||**LINE REGULATION**|±0.3%|±0.2%||±0.2%||±0.2%| ||**LOAD REGULATION**|±0.5%|±0.5%||±0.5%||±0.5%| ||**SETUP, RISE TIME**|1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load|||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||||| ||**VOLTAGE RANGE**<br>**Note.4**|85 ~ 264VAC 120 ~ 370VDC|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**POWER FACTOR (Typ.)**|PF>0.95/230VAC PF>0.99/115VAC at full load|||||| ||**EFFICIENCY (Typ.)**|88%|87%||88%||89%| ||**AC CURRENT (Typ.)**|3.5A/115VAC 1.8A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|35A/115VAC 75A/230VAC|||||| ||**LEAKAGE CURRENT**|<1.5mA / 240VAC|||||| ||**OVERLOAD**|Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power<br>Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power<br>on to recover<br>on to recover|||||| ||**OVER VOLTAGE**|14.4 ~ 16.8V<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>Protection type : Shut down o/p voltage, re-power on to recover|||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||| ||**DC OK SIGNAL**|PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V|||||| ||**FAN CONTROL (Typ.)**|Load 35<br>15% or RTH2<br>50<br>Fan on<br>±<br>≧<br>℃|||||| ||**WORKING TEMP.**|-40 ~ +70<br>(Refer to "Derating Curve")<br>℃|||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃|||||| ||**TEMP. COEFFICIENT**|±<br>/℃<br>℃<br>0.03%<br>(0 ~ 50<br>)|||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**||**Standard**||**Test Level / Note**|| |||Conducted||EN55032||Class B|| |||Radiated||EN55032||Class B|| |||Harmonic current||EN61000-3-2||Class A|| |||Voltage Flicker||EN61000-3-3||-----|| |||EN55035 , EN61000-6-2(EN50082-2)|||||| |||**Parameter**||**Standard**||**Test Level / Note**|| |||ESD||EN61000-4-2||Level 3, 8KV air; Level 2, 4KV contact|| |||RF field||EN61000-4-3||Level 3, 10V/m|| |||EFT/ Burst||EN61000-4-4||Level 3, 2KV|| |||Surge||EN61000-4-5||Level 4, 4KV/Line-FG; 2KV/Line-Line|| |||Conducted||EN61000-4-6||Level 3, 10V|| |||Magnetic Field||EN61000-4-8||Level 4, 30A/m|| |||Voltage Dips and Interruptions||EN61000-4-11||95% dip 0.5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods|| |||529.1K hrs min.<br>Telcordia TR/SR-332 (Bellcore) ; 201.43K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||||| ||**DIMENSION**|199*105*41mm (L*W*H)|||||| ||**PACKING**<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>0.9Kg;15pcs/14.5Kg/0.84CUFT<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>Product Liability Disclaimer<br>For detailed information, please refer to||||||| **NOTE** perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 6. The ambient temperature derating of 3.5 ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:HRP-300N-SPEC 2020-11-03_ **- HRP 300N series** ## 300W Single Output with PFC Function **==> picture [480 x 618] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>PWM fosc : 70KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>-S<br>O.T.P. O.L.P. DETECTION DC OK<br>FG CIRCUIT<br>PFC PWM<br>O.V.P.<br>CONTROL CONTROL<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80 80<br>70<br>60<br>50 Normal load only 60<br>40<br>50<br>20 40<br>85 100 125 135 155 264<br>-40 -10 0 10 20 30 40 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>Function Manual<br>1.Remote Sense<br>The remote sensing compensates voltage drop on the<br>load wiring up to 0.5V.<br>CN100<br>1 2 3 4 5 6 7 CN100 1 NC DC-OK GND +S 7<br>1 7 2 NC NC NC -S 8<br>2 8<br>-S LOAD +S<br>(Pin8) - + (Pin7) Sense lines should<br>be twisted in pairs<br>LOAD (%)<br>LOAD(%)<br>**----- End of picture text -----**<br> Fig 1.1 _File Name:HRP-300N-SPEC 2020-11-03_ **- HRP 300N series** ## 300W Single Output with PFC Function ## **2.DC-OK Signal** **==> picture [462 x 542] intentionally omitted <==** **----- Start of picture text -----**<br> DC-OK signal is a TTL level signal. High when PSU turns on.<br>Between DC-OK(pin3) and GND(pin5) Output Status<br>3.3 ~ 5.6V ON<br>0 ~ 1V OFF<br>CN100<br>1 2 3 4 5 6 7 CN100 1 NC DC-OK GND +S 7<br>1 7 2 NC NC NC -S 8<br>2 8<br>Fig 2.1<br>Peak Power<br>Pav = P pk [x] t + PT npk x [(T-t)] ≤ Prated Pav : Average output power (W)<br>Ppk : Peak output power (W)<br>t<br>Duty T x 100% ≤ 35% Pnpk : Non-peak output power(W)<br>t ≤ 5 sec Prated : Rated output power(W)<br>t : Peak power width(sec)<br>T: Period(sec)<br>P pk<br>P av<br>P npk<br>t<br>T<br>125<br>40<br>35<br>200Vac (1s)<br>30<br>25<br>20 100Vac (5s)<br>15<br>200Vac (5s)<br>10<br>5<br>324 350 400 450 500 550 600 650 700 750<br>Peak output power (W)<br>Duty(%)<br>**----- End of picture text -----**<br> ## **3.Peak Power** **For example (12V model) :** Vin = 100V Duty_max = 35% P av= Prated = 324W P pk= 600W t ≤ 5 sec T ≧ 14.29 sec P av = P pk[x t][+ ] PTnpk[x][(T-t)] = 600x5+ P14.29npk (14.29-5) ≤324W P npk[≤] 175.4W _File Name:HRP-300N-SPEC 2020-11-03_ **- HRP 300N series** 300W Single Output with PFC Function ## **Mechanical Specification** **==> picture [372 x 359] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.980A Unit:mm<br>4-M4 L=6<br>168.5 12.25<br>199<br>168.5 12.25<br>120 42.5<br>1<br>2 4-M4 L=5<br>3<br>4<br>5 FAN Air flow<br>direction<br>6<br>7<br>LED<br>CN100<br>SVR<br>167.5 12.25<br>167.5 12.25<br>17max.<br>4-M4 L=6<br>12.5<br>18<br>11<br>9.2 75 125<br>15<br>18<br>12.5<br>105<br>41<br>2 1<br>8 7<br>**----- End of picture text -----**<br> |Terminal Pin No. Assignment<br>Pin No.<br>Pin No.<br>1<br>2<br>4,5<br>3<br>6,7<br>Assignment<br>Assignment<br>DC OUTPUT -V<br>DC OUTPUT +V<br>FG<br>AC/L<br>AC/N|HRS DF11-08DP-2DS or equivalent<br>Connector Pin No. Assignment (CN100) :|HRS DF11-08DP-2DS or equivalent<br>Connector Pin No. Assignment (CN100) :|HRS DF11-08DP-2DS or equivalent<br>Connector Pin No. Assignment (CN100) :|HRS DF11-08DP-2DS or equivalent<br>Connector Pin No. Assignment (CN100) :| |---|---|---|---|---| ||Pin No.|Assignment|Mating Housing|Terminal| ||1,2,4,6|NC|HRS DF11-8DS<br>or equivalent|HRS DF11-**SC<br>or equivalent| ||3|DC-OK||| ||5<br>|GND||| ||7|+S||| ||8|-S||| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HRP-300N-SPEC 2020-11-03_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →