- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- Available until stocks are exhausted
- SVHC: No SVHC (12-Jan-2017)
- Product Range: HRP-150N Series
- No. of Outputs: 1Outputs
- Output Power Max: 156W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 13A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 56.13 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- HRP 150N series** 150W Single Output with PFC Function Ceaenneererreereeeeeeeeee rer reer er rere **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [185 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>& Ws www.ID 2000000000tuv.com Hl<br>AS/NZS 62368.1 BS EN/EN62368-1 TPTC004 IEC62368-1<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - - ‧ - ‧ - ‧ - ‧ ## ■ **** ## ■ ℃ ■ **** ~~T~~ **** ~~L~~ **** _File Name:HRP-150N-SPEC 2022-03-18_ ## 150W Single Output with PFC Function ## **- HRP 150N series** ## **SPECIFICATION** ||**HRP-150N-24**<br>**HRP-150N-36**<br>**HRP-150N-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.)Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCENote.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>24V<br>36V<br>48V<br>6.5A<br>4.3A<br>3.3A<br>0 ~ 6.5A<br>0 ~ 4.3A<br>0 ~ 3.3A<br>156W<br>154.8W<br>158.4W<br>150mVp-p<br>200mVp-p<br>240mVp-p<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±1.5%<br>±1.5%<br>±1.5%<br>±0.2%<br>±0.2%<br>±0.2%<br>±0.5%<br>±0.5%<br>±0.5%<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.98/115VAC at full load<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>88%<br>89%<br>89%<br>1.7A/115VAC 0.9A/230VAC<br>35A/115VAC 70A/230VAC<br><1mA / 240VAC<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-50 ~ +85℃, 10 ~ 95% RH<br>±0.04%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>159*97*38mm (L*W*H)<br>0.54Kg; 24pcs/12.96Kg/0.9CUFT<br>℃<br><br><br><br><br><br> <br><br><br><br><br><br>(as available on http://www.meanwell.com)<br>℃℃<br>※:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**HRP-150N-12**<br>12V<br>13A<br>0 ~ 13A<br>156W<br>120mVp-p<br>10.2 ~ 13.8V<br>±1.5%<br>±0.3%<br>±0.5%<br>14.4 ~ 16.8V<br>88%<br>3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>5000 meters<br>**OPERATING ALTITUDE Note.6**<br>UL62368-1, TUV BS EN/EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004<br>**Parameter**<br>Conducted<br>Radiated<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032<br>BS EN/EN55032<br>BS EN/EN61000-3-3<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Parameter**<br>ESD<br>RF field<br>EFT/ Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>Level 3, 8KV air; Level 2, 4KV contact<br>Level 3, 10V/m<br>Level 3, 2KV<br>Level 4, 4KV/Line-FG; 2KV/Line-Line<br>Level 3, 10V<br>Level 4, 30A/m<br>95% dip 0.5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>BS EN/EN61000-3-2<br>Harmonic current<br>Class A<br>Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power<br>Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power<br>on to recover<br>on to recover<br>1740.3K hrs min. Telcordia SR-332 (Bellcore) ; 221.7K hrs min. MIL-HDBK-217F (25℃)|**HRP-150N-24**<br>**HRP-150N-36**<br>**HRP-150N-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.)Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCENote.3**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>24V<br>36V<br>48V<br>6.5A<br>4.3A<br>3.3A<br>0 ~ 6.5A<br>0 ~ 4.3A<br>0 ~ 3.3A<br>156W<br>154.8W<br>158.4W<br>150mVp-p<br>200mVp-p<br>240mVp-p<br>21.6 ~ 28.8V<br>28.8 ~ 39.6V<br>40.8 ~ 55.2V<br>±1.5%<br>±1.5%<br>±1.5%<br>±0.2%<br>±0.2%<br>±0.2%<br>±0.5%<br>±0.5%<br>±0.5%<br>16ms/230VAC 16ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.95/230VAC PF>0.98/115VAC at full load<br>30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>88%<br>89%<br>89%<br>1.7A/115VAC 0.9A/230VAC<br>35A/115VAC 70A/230VAC<br><1mA / 240VAC<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-50 ~ +85℃, 10 ~ 95% RH<br>±0.04%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>159*97*38mm (L*W*H)<br>0.54Kg; 24pcs/12.96Kg/0.9CUFT<br>℃<br><br><br><br><br><br> <br><br><br><br><br><br>(as available on http://www.meanwell.com)<br>℃℃<br>※:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**HRP-150N-12**<br>12V<br>13A<br>0 ~ 13A<br>156W<br>120mVp-p<br>10.2 ~ 13.8V<br>±1.5%<br>±0.3%<br>±0.5%<br>14.4 ~ 16.8V<br>88%<br>3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>5000 meters<br>**OPERATING ALTITUDE Note.6**<br>UL62368-1, TUV BS EN/EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004<br>**Parameter**<br>Conducted<br>Radiated<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032<br>BS EN/EN55032<br>BS EN/EN61000-3-3<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Parameter**<br>ESD<br>RF field<br>EFT/ Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>Level 3, 8KV air; Level 2, 4KV contact<br>Level 3, 10V/m<br>Level 3, 2KV<br>Level 4, 4KV/Line-FG; 2KV/Line-Line<br>Level 3, 10V<br>Level 4, 30A/m<br>95% dip 0.5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>BS EN/EN61000-3-2<br>Harmonic current<br>Class A<br>Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power<br>Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power<br>on to recover<br>on to recover<br>1740.3K hrs min. Telcordia SR-332 (Bellcore) ; 221.7K hrs min. MIL-HDBK-217F (25℃)|**HRP-150N-12**|**HRP-150N-24**|**HRP-150N-24**|**HRP-150N-36**|**HRP-150N-36**|**HRP-150N-48**| |---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|12V|24V||36V||48V| |||**RATED CURRENT**|13A|6.5A||4.3A||3.3A| |||**CURRENT RANGE**|0 ~ 13A|0 ~ 6.5A||0 ~ 4.3A||0 ~ 3.3A| |||**RATED POWER**|156W|156W||154.8W||158.4W| |||**RIPPLE & NOISE (max.)Note.2**|120mVp-p|150mVp-p||200mVp-p||240mVp-p| |||**VOLTAGE ADJ. RANGE**|10.2 ~ 13.8V|21.6 ~ 28.8V||28.8 ~ 39.6V||40.8 ~ 55.2V| |||**VOLTAGE TOLERANCENote.3**|±1.5%|±1.5%||±1.5%||±1.5%| |||**LINE REGULATION**|±0.3%|±0.2%||±0.2%||±0.2%| |||**LOAD REGULATION**|±0.5%|±0.5%||±0.5%||±0.5%| |||**SETUP, RISE TIME**|3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load|||||| |||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||||| |||**VOLTAGE RANGENote.4**|85 ~ 264VAC 120 ~ 370VDC|||||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||||| |||**POWER FACTOR (Typ.)**|PF>0.95/230VAC PF>0.98/115VAC at full load|||||| |||**EFFICIENCY (Typ.)**|88%|88%||89%||89%| |||**AC CURRENT (Typ.)**|1.7A/115VAC 0.9A/230VAC|||||| |||**INRUSH CURRENT (Typ.)**|35A/115VAC 70A/230VAC|||||| |||**LEAKAGE CURRENT**|<1mA / 240VAC|||||| |||**OVERLOAD**|Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power<br>Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power<br>on to recover<br>on to recover|||||| |||**OVER VOLTAGE**|30 ~ 34.8V<br>41.4 ~ 48.6V<br>57.6 ~ 67.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14.4 ~ 16.8V|||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||| |||**WORKING TEMP.**|-40 ~ +70℃(Refer to "Derating Curve")|||||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| |||**STORAGE TEMP., HUMIDITY**|-50 ~ +85℃, 10 ~ 95% RH|||||| |||**TEMP. COEFFICIENT**|±0.04%/℃(0 ~ 50℃)|||||| |||**VIBRATION**<br>**OPERATING ALTITUDE Note.6**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>5000 meters|||||| |||**SAFETY STANDARDS**|UL62368-1, TUV BS EN/EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004|||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|||||| |||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**||**Standard**||**Test Level / Note**|| ||||Conducted<br>Radiated||BS EN/EN55032<br>BS EN/EN55032||Class B<br>Class B|| ||||Harmonic current||BS EN/EN61000-3-2||Class A|| ||||Voltage Flicker||BS EN/EN61000-3-3||-----|| ||||BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)|||||| ||||**Parameter**||**Standard**||**Test Level / Note**|| ||||ESD||BS EN/EN61000-4-2||Level 3, 8KV air; Level 2, 4KV contact|| ||||RF field||BS EN/EN61000-4-3||Level 3, 10V/m|| ||||EFT/ Burst||BS EN/EN61000-4-4||Level 3, 2KV|| ||||Surge||BS EN/EN61000-4-5||Level 4, 4KV/Line-FG; 2KV/Line-Line|| ||||Conducted||BS EN/EN61000-4-6||Level 3, 10V|| ||||Magnetic Field||BS EN/EN61000-4-8||Level 4, 30A/m|| ||||Voltage Dips and Interruptions||BS EN/EN61000-4-11||95% dip 0.5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods|| ||||1740.3K hrs min. Telcordia SR-332 (Bellcore) ; 221.7K hrs min. MIL-HDBK-217F (25℃)|||||| |||**DIMENSION**|159*97*38mm (L*W*H)|||||| |||**PACKING**<br>0.54Kg; 24pcs/12.96Kg/0.9CUFT<br>℃<br><br><br><br><br><br> <br><br><br><br><br><br>(as available on http://www.meanwell.com)<br>℃℃<br>※:<br>https://www.meanwell.com/serviceDisclaimer.aspx||||||| _File Name:HRP-150N-SPEC 2022-03-18_ **- HRP 150N series** ## 150W Single Output with PFC Function **==> picture [477 x 615] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>PWM fosc :90KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>-S<br>O.T.P. O.L.P. DETECTION<br>CIRCUIT<br>FG<br>O.T.P.<br>PFC PWM<br>CONTROL CONTROL O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100 Without Cover<br>90<br>80<br>80<br>60 70<br>With Cover<br>Normal load only<br>60<br>40<br>50<br>20<br>40<br>-40 -10 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>Function Manual<br>1.Remote Sense<br>The remote sensing compensates voltage drop on the<br> load wiring up to 0.5V.<br>-V -V +V +V<br>CN100<br>6 4 2<br>5 3 1 CN100<br>6 NC NC +S 2<br>Sense lines should 5 NC NC -S 1<br>-S LOAD +S be twisted in pairs<br>(Pin1) - + (Pin2)<br>LOAD (%)<br>LOAD(%)<br>**----- End of picture text -----**<br> Fig 1.1 _File Name:HRP-150N-SPEC 2022-03-18_ **- HRP 150N series** 150W Single Output with PFC Function ## **2.Peak Power** **==> picture [350 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> P =av P pk [x] t + P T npk x [(T-t)] ≤ P rated P av : Average output power�(W)<br>P pk : Peak output power��(W)<br>t<br>Duty T x 100% ≤ 35% P npk : Non-peak output power(W)<br>t ≤ 5 sec P rated : Rated output power(W)<br>t : Peak power width(sec)<br>T : Period(sec)<br>P pk<br>P av<br>P npk<br>t<br>T<br>125<br>40<br>35<br>200Vac (1s)<br>30<br>25<br>100Vac (5s)<br>20<br>200Vac (5s)<br>15<br>10<br>5<br>154.8 175 200 225 250 275 300 325 350 375<br>Peak output power (W)<br>Duty(%)<br>**----- End of picture text -----**<br> **For example (12V model) :** Vin = 100V Duty_max = 25% P av= Prated = 156W P pk= 300W t�≤ 5 sec T ≧ 20 sec P av = P pk[x t][+ P] T npk[x][(T-t)] = 300x5+ P20 npk (20-5) ≤156W P npk�≤ 108W _File Name:HRP-150N-SPEC 2022-03-18_ **- HRP 150N series** ## 150W Single Output with PFC Function ## **Mechanical Specification** **==> picture [451 x 419] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.901I Unit:mm<br>152.5<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>CN100<br>SVR1<br>4.5<br>24 78<br>159<br>6.5 150<br>6-M3(Both Sides) L=6<br>10 max.<br>22 117<br>Connector Pin No. Assignment (CN100) :<br>Terminal Pin No. Assignment : HRS DF11-6DP-2DSA or equivalent<br>Pin No. Assignment Pin No. Assignment Pin No. Assignment Mating Housing Terminal<br>1 AC/L 4,5 DC OUTPUT -V 1 -S<br>2 AC/N 6,7 DC OUTPUT +V 2 +S HRS DF11-6DS HRS DF11-**SC<br>or equivalent or equivalent<br>3 FG 3~6 NC<br>3.5<br>ψ<br>2-M3 L=4<br>ψ<br>3.5<br>7<br>3.5<br>9.5<br>65<br>84.5 97<br>8.2<br>5 3 1 6 4 2<br>9 18.5 9<br>18 3.5 38<br>28.5<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HRP-150N-SPEC 2022-03-18_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →