HRC0524S1K0N
Non Isolated POL DC/DC Converter, ITE & Laboratory Equipment, 5 W, 0 V, -1 kV, 5 mA, Adjustable
- Manufacturer: XP POWER
- Product type: DC / DC Non Isolated Board Mount Converters - Adjustable Output
- SVHC: No SVHC (27-Jun-2024)
- Depth: 64.8mm
- Width: 33mm
- Height: 15.2mm
- Product Range: HRC05 Series
- Output Power Max: 5W
- Output Current Max: 5mA
- Output Voltage Max: -1kV
- Output Voltage Min: -
- Input Voltage DC Max: 30V
- Input Voltage DC Min: 22VDC
- DC / DC Converter Type: DIP-10, Module
- Power Supply Applications: ITE & Laboratory Equipment
- DC / DC Converter Output Type: Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 224.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
DC-HVDC CONVERTER ## **HRC05** Series ## 5W The HRC05 Series, is a miniature 5W regulated high voltage DC-DC converter product line providing voltages up to 6kV. HRC05 provides a well regulated and fully adjustable output voltage with built in short circuit and overload protection. The adjustable output voltage can be controlled from 0 to 100% with a 0 to +5VDC input. Voltage and current monitor outputs and a +5VDC reference output are included in the standard package for easier high voltage integration. The input control and output monitor signals are digital compatible making these modules an ideal solution for a wide range of high voltage applications. ## **Features** ## **Typical Applications** - +24VDC input (22 to 30V) - Output voltages up to 6kV - 0 to 100% programmable output voltage - Mass Spectrometry - Voltage and current monitor output - On-board +5V reference - Load and line regulation <0.01% - Electrophoresis - Electrostatic Chuck - High Voltage Bias - Detectors - Low ripple <0.01% - Scanning Electron Microscopy - Short circuit, arc and overload protections - UL62368 and UL61010 approvals - Operating temperature: -40°C to +70°C ## **Dimensions** - 3 year warranty 64.8 x 33.0 x 15.2mm (2.55” x 1.30” x 0.60”) ## **Models & Ratings** |Model Number(1)<br>HRC0524S600P|Output Voltage(1)<br>0 to +600V|Model Number(1)<br>HRC0524S600N|Output Voltage(1)<br>0 to -600V|Output Current<br>8.33mA| |---|---|---|---|---| |HRC0524S1K0P|0 to +1000V|HRC0524S1K0N|0 to -1000V|5.00mA| |HRC0524S1K5P|0 to +1500V|HRC0524S1K5N|0 to -1500V|3.33mA| |HRC0524S4K0P|0 to +4000V|HRC0524S4K0N|0 to -4000V|1.25mA| |HRC0524S6K0P|0 to +6000V|HRC0524S6K0N|0 to -6000V|0.83mA| Notes: 1. Other variants are available upon request. DC-HVDC CONVERTER ## **HRC05** Series ## **Input** **==> picture [540 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage Range|22|24|30|VDC|24V nominal| |Input Current, Full Load|||350|mA|@ 22VDC input| |Input Current, No Load|||85|mA|@ 22VDC input| |Input Undervoltage Lockout|OFF/Shutdown @ <20.5V, ON/Restart @ >21.5V||||| |Input Overvoltage Protection|OFF/Shutdown @ >33V, ON/Restart @ <30V||||| |Voltage Programming Input|0||5|VDC|Controls output voltage 0 to 100%, see Signals.| |Overprogramming Protection||5.5||VDC|110% maximum Voltage Programming| ## **Output** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|||6000|VDC|See Models & Ratings table| |Output Current(6)|||14.3|mA|See Models & Ratings table| |Output Programming|0||100|%|Output Voltage is programmable via Analog DC Voltage Programming<br>Input (Vpgm)| |Gain Adjust(4)||±5||%|Potentiometer, see Mechanical Details| |Setpoint Accuracy(3)||±1||%|At maximum Vpgm, No Load| |Linearity(5): Output vs Program|||1.5|%|| |Minimum Load|No minimum load required||||| |Start Up Response|See application notes||||| |Line Regulation|||0.01|%|At full load, maximum output voltage (22V to 30V input)| |Load Regulation|||0.01|%|24Vin, maximum output voltage (0 to 100% load)| |Transient Response|Overshoot <5%, (For 50% - 100% - 50% load change). Load transient duration <25msec (Vout returns to within 1%)||||| |Ripple and Noise|||0.01|%|1MHz bandwidth| |Temperature Coeffcient||100||ppm/°C|| |Stability|||100|ppm/8hrs|At 25°C| |Short Circuit, Overload|||100|%|110% overcurrent protection| |Overtemperature Protection||85||°C|Shutdown @ 85°C typical, ±5%, case temperature| Notes: 1. Specifications after 30 minute warm-up, full load, 25°C, unless otherwise noted. 2. Proper thermal management techniques are required to maintain safe case temperature. 3. Refers to the ability of the unit to accurately deliver the programmed voltage. 4. Refers to the ability to alter the gain of the circuit to allow for setpoint accuracy error. 5. Refers to how much the transfer function can deviate from a straight line in the absence of any setpoint error. 6. No current derating over temperature range. 2 DC-HVDC CONVERTER ## **HRC05** Series ## **General** **==> picture [539 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditons|Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditons|Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditons|Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditons|Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditons| |---|---|---|---|---|---| |Isolation: Input to Output|N/A – Input ground is internally connected to output ground||||| |Construction|5-sided metal case, internally grounded, RTV vacuum encapsulation, UL94V-0 rated||||| |Switching Frequency||100||kHz|At maximum output voltage, full load| |Mean Time Between Failure||1.2||Mhrs|MIL-HDBK-217F, +25°C GB| |Weight||0.1625 (74)||lb (g)|| ## **Environmental** **==> picture [539 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Operating Temperature (Case)(1)|-40||+70|°C|| |Storage Temperature|-55||+105|°C|| |Cooling|Natural convection||||| |Humidity|||95|%RH|Non-condensing| ## **Safety Approvals** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & Conditions<br>**----- End of picture text -----**<br> |Certfcaton|Standard|Notes & Conditons| |---|---|---| |UL|UL/CSA/IEC/EN62368-1, UL/CSA/IEC/EN61010-1|| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| ## **Signals** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Pin Function Description<br>**----- End of picture text -----**<br> |Characteristc|Pin|Functon|Descripton| |---|---|---|---| |+Vin|1|Input: 24VDC|Power Input| |Imon|2|Output: Current Monitor|0V to +5V output measure 0 to 100% Iout, 3% accuracy, Zout = 10kΩ| |Vmon|3|Output: Voltage Monitor|0V to +5V output measure 0 to 100% Vout, 1.5% accuracy,<br>Zout = 10kΩ| |Vpgm|4|Input: Voltage Programming|0V to +5V input programs Vout from 0 to 100%, Z=100kΩ| |Sgnd|5|Signal Ground|Signal Ground| |Vref|6|Output: Voltage Reference|+5V ±2%, Current <10mA| |Disable|7|Input: Remote Disable|Open or No Connect turns unit ON. Ground connection turns unit<br>OFF| |-Vin|8|Input Ground|Power Input Ground| |HVrtn|9|HV Return|High Voltage Return| |HVout|10|HV Output|High Voltage Output| Notes: 1. No current derating over temperature range. Specifications subject to change without notice. 3 DC-HVDC CONVERTER ## **HRC05** Series ## **Mechanical Details** **==> picture [451 x 508] intentionally omitted <==** **----- Start of picture text -----**<br> Ø2.5 (0.10)<br>min pot access<br>for calibra�on<br>15.2 (0.60)<br>7.6 (0.30)<br>64.8 (2.55)<br>3.8 (0.15) 52.07 (2.050)<br>4.6 (0.18) 1 10 8.4 (0.33)<br>6.35 (0.250)<br>2<br>25.4 = 12.7 (0.500)2.54 (0.100)5 EQ SP@ 3564 (1.30)33.0<br>(1.000) 7<br>8 9 0.64 (0.25)<br>6 sq pins<br>55.88 (2.200)<br>4X Ø 1.02<br>(0.40) pins BOTTOM VIEW<br>RECOMMENDED<br>PCB LAYOUT<br>TOP VIEW<br>3.8 3.1<br>(0.15) (0.12)<br>0<br>6.35 (0.250)<br>8.89 (0.350)<br>11.43 (0.450)<br>13.97 (0.550)<br>16.51 (0.650) 21.59<br>19.05 (0.750) (0.850)<br>25.4 (1.000)<br>HIGH VOLTAGE WARNING<br>0<br>55.88 (2.200)<br>0 52.07 (2.050)<br>**----- End of picture text -----**<br> Notes: > 1. Dimensions are in inches (mm). > 2. Weight: 0.1625lb (74g) approx. > 3. Tolerance: X.XX±0.02 (0.51). 4. Pin Tolerance: ±0.005 (0.127). 4 DC-HVDC CONVERTER ## **HRC05** Series ## **Application Notes** ## Vref programming **==> picture [201 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> 1 (+Vin) (HVout) 10<br>Vin R2 32 (Imon)(Vmon)<br>24VDC 45 (Vpgm)(Sgnd) BOTTOM VIEW Rload<br>6 (Vref)<br>7 (Disable)<br>8 (-Vin) (HVrtn) 9<br>**----- End of picture text -----**<br> ## Startup rise time Vout vs Vpgm ## Example 600V model **==> picture [76 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> Vout, Max<br>trise<br>Vout<br>Max<br>Vout 0<br>**----- End of picture text -----**<br> |Load|trise| |---|---| |0.3|54ms| |0.375|200ms| |0.75|400ms| |1.5|1s| V/I rectangular characteristics V programming linearity **==> picture [202 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> Vout<br>Vout, Max<br>Iout, Max Iout<br>**----- End of picture text -----**<br> **==> picture [177 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> Vout<br>100%<br>V al<br>100% Vpgm<br>**----- End of picture text -----**<br> 5 10 Jan 2024
Updated at April 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →