HPL5K0TS100
AC/DC Enclosed Power Supply (PSU), ITE & Medical, 1 Outputs, 5 kW, 100 VDC, 50 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: HPL5K0 Series
- No. of Outputs: 1Outputs
- Output Power Max: 5kW
- Input Voltage VAC: 180V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 50A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 100VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1961.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
HPL5K0 series ## 5kW ## **Fan cooled** **AC-DC power supplies** The HPL5K0 series offers ultimate flexibility with both output voltage and output current programming and user defined signals, warnings and alarms. Programming is via voltage, I²C PMBus, RS485 and CANopen in a very high efficiency, high power density 5kW chassis mount package. The HPL5K0 can be used in both constant voltage and constant current operation. Measuring just 13.0” x 5.0” x 5.0”, the HPL5K0 also features active current sharing, remote on/off, remote sense and a power OK signal. The 5V/2A standby output is available whenever the mains supply is present. **==> picture [293 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> Features Applications<br>oNa R 7<br>Healthcare Industrial Semiconductor<br>Electronics Manufacturing<br>Technology<br>**----- End of picture text -----**<br> - f 3 Phase 180 to 264VAC input - 3 wire & earth - f High efficiency - up to 93% - f Programmable output voltage (0-105%) - f Programmable output current (0-110%) - f Parallel operation - f Analog and digital interfaces - f Multiple digital protocols - PMBus, CANopen, MODBUS & SCPI - f Fully featured signals & controls **==> picture [56 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>**----- End of picture text -----**<br> 330.2 x 127.0 x 127.0mm (13.00 x 5.00 x 5.00”) **==> picture [152 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> Documentation<br>Po<br>For further information click the link or scan<br>the code<br>xppower.com<br>**----- End of picture text -----**<br> - f 5V/2A standby output - f Graphical user interface (GUI) - f SEMI F47 compliant - f 3 year warranty ## **Models & ratings** |Model number(1)|Max<br>output power|Output voltage V1|Output voltage V1|Output voltage V1|Output current|Output current|Efficiency(2)| |---|---|---|---|---|---|---|---| |||Minimum|Nominal|Maximum|Minimum|Maximum|| |HPL5K0TS048|5kW|0 VDC|48 VDC|50.4 VDC|0.0A|104.0 A|92%| |HPL5K0TS060|5kW|0 VDC|60 VDC|63.0 VDC|0.0A|83.3 A|92%| |HPL5K0TS100|5kW|0 VDC|100 VDC|105.0 VDC|0.0A|50.0 A|92%| |HPL5K0TS200|5kW|0 VDC|200 VDC|210.0 VDC|0.0A|25.0 A|92%| Notes: 1. Standard models include PMBus, CANopen and RS485 interfaces. RS485 default is full duplex. RS485 half duplex can be configured via I2C or factory configured on request. 2. Measured with 180 VAC input and full load. 3. USB host adaptor available, converting to I²C, CANbus and RS485. Works with application download: XP PS Manager. Contact sales for kit: I²C-USB 4. Standard models include PMBus, CANopen and RS485 interfaces. RS485 default is full duplex. RS485 half duplex can be configured via I[2] C or factory configured on request. To replace RS485 with RS232 or UART, contact sales. 1 . **AC-DC power supplies** ## HPL5K0 series ## **Input** **==> picture [554 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage|180||264|VAC|5kW output power max, 3 wire & earth| |Input frequency|47||63|Hz|| |Power factor||0.98|||Complies with EN61000-3-2 for Class A| |Input current|||18|A|Per phase, 180VAC (5 kW)| |Inrush current|||60|A|Per phase, 264VAC (5 kW), cold start 25°C| |Earth leakage current|||1.0|mA|264VAC/60Hz| ||||3.3||264VAC/60Hz, single fault| |Input protection|F25A / 250V fuse ftted in each phase||||| |Loss of phase|Shut down after 0.5s, auto-recovery||||| ## **Output** **==> picture [554 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Output voltage|0||210|VDC|See Models and ratings table| |Output set tolerance||±0.5||%|Nominal voltage irrespective of set voltage.| |+5 V standby tolerance||±3||%|5V/2A Standby| |Output voltage program|0||105|%|Of nominal, slew rate <40ms 10-105% & 105-10%.<br>Max frequency of voltage program is 0.5Hz 0-5% load,<br>0.67Hz 5-10% load, 1Hz 10-20% load, 3Hz 20-100% load| |Output voltage adjust|± 10|||%|Of set output via potentiometer 105% of nominal max.| |Output current program|0||110|%|Of nominal| |Minimum load|0|||A|No minimum load required| |Start up delay||1.8|2.3|s|Under all load and line conditions| |Start up rise time|||40|ms|| |Hold up time|20|22||ms|208VAC at 5000 W and 25°C| |Line regulation|||±0.5|%|Of nominal voltage| ||||±0.5||5V/2A Standby| |Load regulation|||1|%|0-100% or 100-0% load| ||||2||5V/2A Standby| |Transient response|||3|%|Deviation with a 50-75-50% load change. Output returns to within 1% in<br>less than 500µs| |Ripple & noise|||1/2.5|%|Of nominal voltage/5V Standby. Measured with 20 MHz bandwidth<br>limited oscilloscope 0-50°C.| |Overshoot|||5|%|Turn on & turn off| |Overvoltage protection|||120|%|Of nominal voltage, latching. Cycle AC to reset. No protection for 5V<br>Standby| |Overtemperature protection|Auto resetting thermal protection||||| |Overload protection|||±3|% of<br>max load|Set current limit point. Constant current characteristics.<br>Max current limit is 108% ±3% of maximum rated current.<br><5A max| |Temperature coeffcient|||0.03 of max load|%/˚C|| |Short circuit protection|Constant current characteristics. 5V/2A Standby: Foldback characteristic <5A max||||| |Remote sense|Compensates for 1% max of nominal voltage per lead, 2% of total nominal voltage drop. Not ftted on HPL5K0TS200||||| |5V standby supply|5V/2A standby supply, available whenever the mains supply is present||||| Specifications subject to change without notice. 2 **AC-DC power supplies** ## HPL5K0 series ## **General** **==> picture [554 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 92 93 % Measured from 180 to 264VAC, 5V Standby at full load<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency|92|93||%|Measured from 180 to 264VAC, 5V Standby at full load| |Isolation: Input to output<br>Input to ground<br>Output to ground|4000(1)|||VDC|| ||2500(1)|||VDC|| ||500|||VDC|| |Switching frequency|40|45|50|kHz|Fixed frequency PFC| ||40||250|kHz|Variable frequency main converter| |Power density|||15.38|W/in3|| |Signals and controls|V Program, I Program, AC OK, DC OK, Fan Fail/Temperature Warning, Sync, PMBus, Inhibit, Current Share.||||| |MTBF||450||khrs|Telecordia 332, 25°C| |Weight||12.5 (5.7)||lb (kg)|| 1. Rating for complete assembly with HI-POT screw removed (see mechanical details for screw position). Maximum isolation test voltage is 2121VDC with screw installed. ## **Environmental** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-20||+70|°C|Derate linearly from 50°C to 50% rated power at 70°C| |Storage temperature|-40||+85|°C|| |Cooling|Force-cooled with intelligent fan speed control||||| |Humidity|5||95|%RH|Non-condensing| |Operating altitude|||5000|m|Medical| ||||5000||ITE| |Transport altitude|||10000|m|| |Shock|±3 x 30g shocks in each plane, total 18 shocks. 30g = 11 m||||s (±0.5ms) half sine. Conforms to EN60068-2-27 & EN60068-2-47| |Vibration|Single axis 10-500Hz at 1.5g sweep and endurance at reso||||nance in all 3 planes. Conforms to EN60068-2-6| |Accoustic noise|<70 db(A) Lw||||| ## **Application notes** ## Output voltage programming **==> picture [193 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> 105<br>100<br>80<br>60<br>40<br>20<br>0<br>0 1 2 3 4 5<br>Vprog (V)<br>Output Voltage (% of nominal)<br>**----- End of picture text -----**<br> ## Output current programming **==> picture [193 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> 110<br>100<br>80<br>60<br>40<br>20<br>0<br>0 1 2 3 4 5<br>Iprog (V)<br>Output Current (% of nominal)<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 3 **AC-DC power supplies** ## HPL5K0 series ## **Signals & controls** **==> picture [555 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Function<br>**----- End of picture text -----**<br> ||Functon| |---|---| ||| |V program(1)(2)|0V to 5V signal will program Vout from 0-105%. VProg accurancy ±1% of nominal output voltage. When left open, supply will go<br>into its default operating mode.| |I program(1)(2)|0V to 5V signal will program the current limit from 0-110%. When this signal is left open, supply will go into its default operating mode.<br>IProg accurancy ±2% of maximum rating.| |AC OK|LOW = Input Voltage is within operating range, HIGH = Input Voltage is outside of operating range or there is a loss of phase.<br>Uncommitted opto-transistor, 2ms warning time| |DC OK|When the supply is used as a variable output supply, this signal is disabled. When the supply is programmed as a fxed output supply,<br>LOW = Vout > 95% of Vnominal. This level is programmable by the user through the PMBus. Uncommitted opto-transistor| |Fan fail/Temp warning|High = Fan FAIL and/or overtemperature, Low = Fan OK and temperature OK (3.3V Logic), unit switches off 10s after Fan Fail/Temp<br>Warning alarm, auto recovery. XP GUI available for download, contact sales.| |Sync.|Connect parallel units to synchronise output turn on.| |PMBus, CANopen and RS485|The interface specifcation is detailed in a separate document “HPL5K0 Communication, Control and Status Specifcation”.<br>XP GUI available for download, contact sales. Vout monitor accuracy is ±1% of nominal voltage, Vout setting accuracy is ±1% of nominal<br>voltage, Iout monitor accuracy is ±2% of full load, Iout setting accuracy is ±2% of full load.| |Current share|Connecting pin 23 on one unit to pin 23 on a like voltage unit will force the current to be shared. Up to 5 units can be paralleled. Current<br>share accuracy ±3% of full load of single unit.| |Inhibit|Uncommitted opto diode. See signal connections.| (1) In analog mode, the default Vout and Iout settings are 0% when open circuit. (2) To activate analog mode, PMBus_EN (pin 24) must be pulled down to SGND. Default when open is digital progamming. ## **Safety approvals** **==> picture [554 x 211] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Safety standard Notes & conditions<br>IEC62368-1 Ed 2 Information technology<br>CB report<br>IEC60601-1 Ed 3.1 Including Risk Management Medical<br>UL62368-1, CSA 22.2 No.62368-1 Information technology<br>UL<br>ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08 Medical<br>EN62368-1 Information technology<br>EN<br>EN60601-1/2006 Medical<br>CE Meets all applicable directives<br>UKCA Meets all applicable legislation<br>Equipment protection class Class I See safety agency conditions of acceptibility for details<br>Isolation Means of protection Notes & conditions<br>Primary to secondary 2 x MOPP (Means of patient protection)<br>Primary to earth 1 x MOPP (Means of patient protection) IEC60601-1 Ed 3.1<br>Secondary to earth N/A<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 4 **AC-DC power supplies** ## HPL5K0 series ## **EMC: emissions** |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| |Conducted|EN55011/EN55032|Class B|| |Radiated|EN55011/EN55032|Class A|| |Harmonic currents|EN61000-3-2|Class A|| ## **EMC: immunity** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |ESD immunity|EN61000-4-2|4|A|±8kV contact / ±15kV air discharge| |Radiated immunity|EN61000-4-3|3|A|| |EFT/Burst|EN61000-4-4|3|A|| |Surge|EN61000-4-5|Installation class 4|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic feld|EN61000-4-8|4|A|| |Dips and interruptions|EN61000-4-11<br>(200 VAC)|Dip 100% (0 VAC), 8.4ms|A|| |||Dip 100% (0 VAC), 16.7ms|A|| |||Dip 60%, 200ms|A|| |||Dip 30%, 500ms|A|| |||Dip 20%, 5000ms|B|| |||Int 100% (0 VAC), 5000ms|B|| ||EN61000-4-11<br>(240 VAC)|Dip 100% (0 VAC), 10ms|A|| |||Dip 100% (0 VAC), 20ms|A|| |||Dip 60%, 200ms|A|| |||Dip 30%, 500ms|A|| |||Dip 20%, 5000ms|B|| |||Int 100% (0 VAC), 5000ms|B|| ||EN60601-1-2<br>(200 VAC)|Dip 100% (0 VAC), 10ms|A|| |||Dip 100% (0 VAC), 20ms|A|| |||Dip 60% (80/152 VAC), 100ms|A|| |||Dip 30% 140/266 VAC|A|| |||Int 100% (0 VAC), 5000ms|B|| ||EN60601-1-2<br>(240 VAC)|Dip 100% (0 VAC), 10ms|A|| |||Dip 100% (0 VAC), 20ms|A|| |||Dip 60%, 100ms|A|| |||Dip 30%, 500ms|A|| |||Int 100% (0 VAC), 5000ms|B|| ||SEMI F47-0706|208VAC nominal|A|| Specifications subject to change without notice. 5 **AC-DC power supplies** ## HPL5K0 series **==> picture [336 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> Signals connection<br>Vout<br>adj<br>AC OK<br>DC OK<br>29 30<br>1 2<br>**----- End of picture text -----**<br> ## View A **==> picture [554 x 37] intentionally omitted <==** **----- Start of picture text -----**<br> J1 signal connector connections<br>Pin Function Description<br>**----- End of picture text -----**<br> |J1 signal connector connectons|J1 signal connector connectons|J1 signal connector connectons| |---|---|---| |Pin|Functon|Descripton| |||| |1|DCOK|Low means Vout is within range (Opto Isolated; Open Collector)| |2|DCOK return|Return for DCOK (Opto Isolated)| |3|Remote inhibit|High to Inhibit - uncommitted opto diode| |4|Remote inhibit return|Return for Inhibit - uncommitted opto diode| |5|A0|I2C Device Address Bit (10kΩpull up to 3.3V)| |6|A1|I2C Device Address Bit (10kΩpull up to 3.3V)| |7|A2|I2C Device Address Bit (10kΩpull up to 3.3V)| |8|CANH|CAN Bus Communication using CANopen protocol| |9|RS485_Y|RS485 Differential Serial Bus Communication| |10|CANL|CAN Bus Communication using CANopen protocol| |11|RS485_Z|RS485 Differential Serial Bus Communication| |12|SGND|Signal Return| |13|RS485_A|RS485 Differential Serial Bus Communication| |14|I2C SDA|I2C (10kΩpull up to 3.3V)| |15|RS485_B|RS485 Differential Serial Bus Communication| |16|I2C SCL|I2C Bus Clock (10kΩpull up to 3.3V)| |17|FAN_FAIL/TEMP WARNING|Fan Failure/Temp Warning Reporting (High means fan fails and/or overtemperature rating;<br>10kΩpull up to 3.3V)| |18|SYNC|Connect parallel units to synchronise output turn on| |19|VPROG|0 - 5V to set Vout from 0 to 105%(1)(50.8 kΩdischarge resistor to SGND(2))| |20|RS+|Positive Remote Sense (HPL5K0TS048, HPL5K0TS060 and HPL5K0TS100 only)| |21|RS-|Negative Remote Sense (HPL5K0TS048, HPL5K0TS060 and HPL5K0TS100 only)| |22|IPROG|0 - 5V to set Current Limit from 0 - 110% of rated current(1)(50.8 kΩdischarge resistor to SGND(2))| |23|ISHARE|0 - 2.6V for current sharing of units in parallel| |24|PMBUS_EN|Selecting Digital (open) or Analog (low) mode for VPROG & IPROG (10kΩpull up to 3.3V)| |25|ACOK|Low means AC is within range operating range (Opto Isolated; Open Collector)| |26|ACOK Return|Return for ACOK (Opto isolated)| |27|5VSBY|5V/2A Standby| |28|5VSBY|5V/2A Standby| |29|5VSBY_RTN|5V/2A Standby Return| |30|5VSBY_RTN|5V/2A Standby Return| ## Notes: 1. In analog mode, the default Vout & Iout settings are 0% when Vprog & Iprog are open circuit. 2. To activate analog mode, PMBus_EN must be pulled down to 5VSBY-RTN. Default if left open is digital programming. Specifications subject to change without notice. 6 **AC-DC power supplies** ## HPL5K0 series ## **Signals & controls** DC OK **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> AC OK<br>**----- End of picture text -----**<br> **==> picture [462 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> 5 V Standby 5 V Standby<br>Pin 27/28 Pin 27/28<br>3K3 3K3<br>Pin 1 Pin 25<br>100R 15 V 100R 15 V<br>4 mA max 4 mA max<br>High: DC NOT OK High: AC NOT OK<br>Low: DC OK Low: AC OK<br>Pin 2 Pin 26<br>5 V Standby 5 V Standby<br>Return Return<br>Pin 29/30 Pin 29/30<br>**----- End of picture text -----**<br> Fan fail/Temperature warning Inhibit **==> picture [242 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> 3V3<br>10K<br>Pin 17<br>High: FAN NOT OK/Over Temperature<br>Low: FAN OK/Temperature OK<br>3.3V TTL compatible<br>Pin 12<br>SIGNAL GND<br>**----- End of picture text -----**<br> **==> picture [240 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 5 V Standby<br>Pin 27/28<br>511R<br>Pin 3<br>Open/Floating: Power Supply ON<br>High: Power Supply OFF<br>0.5 mA min to inhibit<br>8mA max<br>Pin 4<br>5 V Standby<br>Return<br>Pin 29/30<br>**----- End of picture text -----**<br> ## Current share **==> picture [372 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> HPL5K0 HPL5K0 HPL5K0<br>V1 Output Current V1 Output Current V1 Output<br>- + Share - + Share - + Up to 5 x HPL5K0 units<br>Pin 23 Pin 23<br>To synchronise output turn on from application of AC input,<br>SGND SGND connect SYNC (pin 18) of parallel units together.<br>Pin 12 Pin 12<br>- +<br>Load<br>+ Sense - Sense<br>- Sense + Sense<br>- Sense + Sense<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 7 **AC-DC power supplies** ## HPL5K0 series **==> picture [554 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> LED signals LED state Signals<br>Conditions<br>FAN _FAIL/ Remote<br>AC OK DC OK AC OK DC OK<br>TEMP inhibit<br>Vout<br>AC input OK ON ON [(3)] LOW LOW LOW LOW<br>adj<br>AC not present or too low OFF OFF HIGH HIGH LOW X [(2)]<br>AC OK<br>DC OK AC present but out of range or PFC Blink<br>failure or no primary to secondary (0.2s ON, OFF HIGH HIGH LOW X [(2)]<br>communication 0.2s OFF)<br>29 30<br>Output over voltage ON OFF LOW HIGH LOW LOW<br>Current limit Blink LOW or<br>ON LOW LOW LOW<br>(Constant current response) (0.2s ON, 0.2s OFF) HIGH [(3)]<br>Fan failure/Thermal shutdown ON OFF LOW HIGH HIGH [(1)] LOW<br>Blink<br>1 2 Remote OFF ON (1.0s ON, 1.0s OFF) LOW HIGH LOW HIGH<br>Blink<br>PMBus operation OFF ON LOW HIGH LOW LOW<br>View A (1.0s ON, 1.0s OFF)<br>**----- End of picture text -----**<br> ## Notes: 1. In case of fan failure, and/or Overtemperature, FAN_FAIL/Temp Warning signal will be set 10s before output shutdown. 2. Don’t care / not applicable. 3. DC_OK LED is ON if Output Voltage >= VOUT_UV_FAULT_LIMIT, if Output Voltage < VOUT_UV_FAULT_LIMIT, the DC_OK LED will be OFF ## **Mechanical details** **==> picture [546 x 306] intentionally omitted <==** **----- Start of picture text -----**<br> 127.0 (5.00)<br> 9.4 (0.37)<br> 32.0 (1.26)<br>See View A<br>DC OUT Terminals 26.7 (1.05)<br>4 x M5 Screw.<br>Max torque: 3.2Nm<br> 130.6 (5.14) 152.4 (6.00) 4 x M4 Moun�ng point.<br>10.2 4.0 max screw penetra�on.<br>(0.40) Max torque 1.6Nm<br> 14.0 (0.55)<br>127.0 (5.00)<br>70.1 101.6 (4.00)<br>(2.76)<br>76.2<br>(3.00)<br> 25.4 (1.00)<br>M4 E arth Stud.<br>Max torque: 1.6Nm 16.9 (0.67)<br>AC Input Terminals. 3 x M4. Pitch:13.0, AIRFLOW 120 x 120mm fan<br> 10.4 (0.41) Access width: 10.0, Max torque: 1.5Nm DIRECTION<br>30.4 (1.20) 4 x M4 Moun�ng point.<br>7.9 92.7 (3.65) 212.6 (8.37) 4.0 max screw penetra�on.<br>(0.31) Max torque 1.6Nm<br> 101.6 (4.00)<br> 127.0 (5.00)<br>M3 x 12 countersunk<br>screw for HI-POT<br> 33.3 (1.31)<br> 81.0 (3.19) M3 screw. See Applica�on Note 'Dielectric Strength Tes�ng’<br> 330.2 (13.00)<br>**----- End of picture text -----**<br> **==> picture [24 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br>**----- End of picture text -----**<br> 1. All dimensions are in mm (inches). 2. Weight 5.7kg (12.5lb) 3. Signal Connector: P/N JST S30B-PHDSS (LF) (SN) or equivalent Mates with P/N JST PHDR-30VS or equivalent Contact: SPHD-002T-P0.5 09 March 2026 8
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →