HPF3K0PS24
AC/DC Enclosed Power Supply (PSU), ITE, Industrial & Medical, 1 Outputs, 3 kW, 24 VDC, 125 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (23-Jan-2024)
- Product Range: HPF3K0 Series
- No. of Outputs: 1Outputs
- Output Power Max: 3kW
- Input Voltage VAC: 180V AC to 264V AC
- Power Supply Output Type: Programmable
- Output Current - Output 1: 125A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Medical
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 769.98 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **HPF3K0** Series ## 3kW **FAN COOLED** ## AC-DC POWER SUPPLIES The HPF3K0 series provides a suite of sophisticated digital control and monitoring functions, which equip the product for use in systems with a distributed control architecture. Medical and information technology safety approvals, high power density and class B conducted emissions are just part of the generous feature set, supporting use in a wide variety of applications. ## **Features** ## **Applications** - Medical and Information Technology safety approvals - Multiple serial data communication protocols: PMBus, CANopen, MODBUS and SCPI - Programmable output voltage (0-105%) **==> picture [149 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Healthcare Industrial Semiconductor Technology<br>Electronics Manufacturing<br>**----- End of picture text -----**<br> - Programmable output current (0-110%) - Intelligent fan speed control ## **Dimensions** - Parallel operation - High efficiency – up to 93% - Analogue and digital interfaces 279.4 x 177.8 x 63.5mm (11.0” x 7.00” x 2.50”) (Not including connectors and fan guards) - Graphical User Interface - 5V/2A housekeeping supply - 3 year warranty ## **Models & Ratings** |Model Number(1)<br>HPF3K0PS24|Max<br>Output Power<br>3000W|Output Voltage V1|Output Voltage V1|Output Voltage V1|Output Current|Output Current|Efficiency(2)<br>90.3%| |---|---|---|---|---|---|---|---| |||Minimum<br>0VDC|Nominal<br>24VDC|Maximum<br>25.2VDC|Minimum<br>0.0A|Maximum<br>125.0A|| |HPF3K0PS36|3000W|0VDC|36VDC|37.8VDC|0.0A|83.3A|91.7%| |HPF3K0PS48|3000W|0VDC|48VDC|50.4VDC|0.0A|62.5A|92.5%| |HPF3K0PS60|3000W|0VDC|60VDC|63.0VDC|0.0A|50.0A|92.9%| ## **Notes:** 1. Standard models include PMBus, CANopen and RS485 interfaces. RS485 default is full-duplex. RS485 half-duplex can be configured via I[2] C or factory configured on request. To replace RS485 with RS232 or UART, contact sales. 2. Measured with 230VAC input and full load. AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **Input** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons|Notes & Conditons| |---|---|---|---|---|---|---| |Input Voltage<br>(see application notes)|180||264|VAC|3000W|Single phase input| ||90||180||1500W|| |Input Frequency|47||63|Hz||| |Power Factor||0.98|||Complies with EN61000-3-2 for Class A @ 208V|| |Input Current||19||A|90VAC 50% load or 180VAC 100% load|| |Inrush Current|||60|A|264VAC, 25°C cold start|| |Earth Leakage Current|||450|µA|264VAC, 60Hz|| |Input Protection|F25A/250V fuse ftted in line and neutral|||||| ## **Output** **==> picture [540 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc<br>|Minimum<br>|Typical|Maximum<br>|Units<br>|Notes & Conditons<br>| |---|---|---|---|---|---| |Output Voltage|0||63|VDC|See Models and Ratings table| |Output Set Tolerance||±0.1||%|Nominal voltage irrespective of set voltage| |Output Voltage Program|0||105|%|Of nominal, slew rate <40ms 10-105% & 105-10%.<br>Max frequency of voltage program is 0.5Hz 0-5% load,<br>0.67Hz 5-10% load, 1Hz 10-20% load, 3Hz 20-100% load| |Output Voltage Adjust|± 10|||%|Of set output via potentiometer 105% of nominal max.| |Remote Sense|Compensates for 1% max of nominal voltage per lead, 2% of total nominal voltage.||||| |Output Current Program|0||110|%|Of nominal| |Minimum Load|0|||A|No minimum load required| |Start Up Delay||1.8|2.3|s|Under all load and line conditions| |Start Up Rise Time|||40|ms|| |Hold Up Time|13|15||ms|208VAC at 100% load and 25°C| ||10|12|||208VAC at 100% load and -20°C| |Line Regulation|||±0.1|%|Of nominal voltage. Input variation 90-264VAC| ||||±0.5||5V Standby| |Load Regulation|||±0.5|%|0-100% or 100-0% load| ||||±2.0||5V Standby| |Transient Response|||3|%|Deviation with a 50-75-50% load change. Output returns to within 1%<br>in less than 500µs| |Ripple & Noise|||1|%|Of nominal voltage. Peak-peak. 0 to 50°C 20MHz bandwidth with no<br>additional flter.| ||||2.5||5V Standby| |Overshoot|||5|%|Turn on and turn off| |Overvoltage Protection|110||120|%|Of nominal voltage, latching. Cycle AC to reset. No protection for 5V<br>Standby| |Overtemperature Protection|Auto resetting thermal protection||||| |Overload Protection|||110|% of<br>max load|Tolerance: ±3% of max load. Default constant current mode<br>behaviour, with user programmable protection threshold and<br>behaviours. De-rated power limit of 1500W for operation at 90 -<br>180VAC input.<br>5V Standby: 5A max| |Temperature Coeffcient|||0.02|%/˚C|Of nominal voltage and 5V standby| |Short Circuit Protection|Constant current characteristics. Main output: Constant cu||||rrent characteristic. 5V Standby: Hiccup characteristic <5A max.| |Standby Voltage||5||VDC|| |Standby Tolerance||±3||%|At 50% load| |Standby Current||2||A|| Specifications subject to change without notice. 2 AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **General** **==> picture [539 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>Efficiency 92 % 230VAC, 100% load, 5V Standby at full load<br>**----- End of picture text -----**<br> |Characteristc<br>Effciency|Minimum|Typical<br>92|Maximum|Units<br>%|Notes & Conditons<br>230VAC, 100% load, 5V Standby at full load| |---|---|---|---|---|---| |Isolation: Input to Output<br>Input to Ground<br>Output to Ground|4000|||VAC|Reinforced insulation. 2 x MOPP| ||1500|||VAC|Basic insulation. 1 x MOPP| ||500|||VDC|Functional insulation| |Switching Frequency||40||kHz|Fixed frequency PFC| ||41||250|kHz|Variable frequency main converter| |Power Density|||0.95 (15.6)|W/cm3(W/in3)|| |MTBF||3810||khrs|Telecordia SR-332 Issue 4, +25°C| |Weight||4.0 (8.8)||kg (lb)|| ## **Environmental** **==> picture [539 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc<br>|Minimum<br>|Typical|Maximum<br>|Units<br>|Notes & Conditons<br>| |---|---|---|---|---|---| |Operating Temperature|-20||+70|°C|Derate linearly from +50°C to 50% rated power at +70°C| |Storage Temperature|-40||+85|°C|| |Cooling|Force air-cooled with intelligent fan speed control||||| |Humidity|5||95|%RH|Non-condensing| |Operating Altitude|||5000|m|Medical| ||||5000||IT| |Shock|±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (±0.5ms) half sine. Conforms to EN60068-2-27 & EN60068-2-47||||| |Vibration|Single axis 10-500Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| |Acoustic Noise|<66dB LPA||||| ## **Signals & Controls** ||Digital Control & Monitoring Functon| |---|---| |PMBus, CANopen and RS485|Operation of the product using the feldbus interfaces and associated protocols is defned in the supporting document ‘HPA1K5/<br>HPF3K0 Communication, Control and Status Specifcation’. Installation and use of the XP PS Manager software (graphical user<br>interface) is defned in the supporting document ‘XP PS Manager User Manual’. These documents are available through the XP<br>Power website.<br>Analog to digital monitoring accuracy: Vout monitor accuracy is ±0.1% of nominal voltage. Iout monitor accuracy is ±0.1% of full<br>load. Vout and Iout setting accuracy is ±0.1% of nominal voltage/full load| ||Analog Hardware Functon| |V Program|0V to 5V signal will program Vout from 0-105%. VProg accuracy ±1% of nominal output voltage. Minimum source current 0.5mA. In<br>analog programming mode, Vout & Iout will be zero if either Vprog or Iprog is open circuit. Link PMBus_EN (pin 24) to SGND (pin 12)<br>to enable analog mode| |I Program|0V to 5V signal will program the current limit from 0-110%. IProg accuracy ±2% of maximum current. Minimum source current<br>0.5mA| |AC OK|Uncommitted opto-transistor. Circuit conducting means AC is within range. 2ms minimum warning time. See typical connection<br>diagram on page 7| |DC OK|Uncommitted opto-transistor. The operating threshold of this signal is driven from the VOUT_UV_FAULT digital user variable, which<br>is 95% of nominal voltage by default and is programmable via PMbus. See typical connection diagram on page 7| |Fan Fail/Temp Warning|3.3V logic signal referenced to SGND (pin 12). High = Fan FAIL and/or overtemperature, Low = Fan OK and temperature OK, unit<br>switches off 10s after Fan Fail/Temp Warning alarm, auto recovery| |Sync|Connect parallel units to synchronize output turn on following application of AC input| |Current Share|Connecting pin 23 on one unit to pin 23 on a like voltage unit will force the current to be shared. Up to 5 units can be paralleled.<br>Current share accuracy ±3% of a single unit maximum current rating.| |Inhibit|Uncommitted opto-diode. User programmable to become Enable signal. See typical connection diagram page 7| 3 AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **EMC: Emissions** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon<br>|Standard<br>|Test Level<br>|Notes & Conditons<br>| |---|---|---|---| |Conducted|EN55011/EN55032|Class B|Class A <80% nominal output voltage| |Radiated|EN55011/EN55032|Class A|| |Harmonic Currents|EN61000-3-2|Class A|Input > 115Vac @1500W, > 200Vac @3000W| |Voltage Flicker|EN61000-3-3||| ## **EMC: Immunity** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon<br>|Standard|Test Level|Criteria|Notes & Conditons<br>| |---|---|---|---|---| |ESD Immunity|EN61000-4-2|4|A|±8kV contact / ±15kV air discharge| |Radiated Immunity|EN61000-4-3|3|A|| |EFT/Burst|EN61000-4-4|3|A|| |Surge|EN61000-4-5|Installation class 4|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic Field|EN61000-4-8|4|A|| |Dips and Interruptions|EN61000-4-11<br>(100VAC)|Dip 100%, 8.4ms|A|| |||Dip 100%, 16.7ms|A|| |||Dip 60%, 200ms|B|Criteria A derate to 320W| |||Dip 30%, 500ms|B|Criteria A derate to 940W| |||Dip 20%, 5000ms|B|Criteria A derate to 710W| |||Int 100%, 5000ms|B|| ||EN61000-4-11<br>(240VAC)|Dip 100%, 10ms|A|| |||Dip 100%, 20ms|B|Criteria A derate to 1420W| |||Dip 60%, 200ms|B|Criteria A derate to 1590W| |||Dip 30%, 500ms|A|| |||Dip 20%, 5000ms|A|| |||Int 100%, 5000ms|B|| ||EN60601-1-2<br>(100VAC)|Dip 100%, 10ms|A|| |||Dip 100%, 20ms|A|| |||Dip 60%, 100ms|B|Criteria A derate to 320W| |||Dip 30% , 500ms|B|Criteria A derate to 940W| |||Int 100%, 5000ms|B|| ||EN60601-1-2<br>(240VAC)|Dip 100%, 10ms|A|| |||Dip 100%, 20ms|B|Criteria A derate to 1420W| |||Dip 60%, 100ms|B|Criteria A derate to 1590W| |||Dip 30%, 500ms|A|| |||Int 100%, 5000ms|B|| ||SEMI F47<br>(100VAC)|Dip 22% (78VAC),<br>1000ms|B|Criteria A derate to 1100W| |||Dip 33% (67VAC),<br>500ms|B|Criteria A derate to 860W| |||Dip 55% (45VAC),<br>200ms|B|Criteria A derate to 422W| ||SEMI F47<br>(200VAC)|Dip 22% (156VAC)<br>1000ms|A|| |||Dip 33% (134VAC)<br>500ms|B|Criteria A derate to 2360W| |||Dip 55% (90VAC)<br>200ms|B|Criteria A derate to 1460W| Specifications subject to change without notice. 4 AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **Safety Approvals** |**Safety Approvals**||| |---|---|---| |Certification<br>CB Report|Safety Standard<br>IEC62368-1 Ed 2|Notes & Conditions<br>Information Technology| ||IEC60601-1 Ed 3 Including Risk Management|Medical| |UL|UL62368-1, CSA 22.2 No.62368-1, UL60950-1|Information Technology| ||ANSI/AAMI ES60601-1:2005 & CSA C22.2,<br>No.60601-1:08|Medical| |EN|EN62368-1|Information Technology| ||EN60601-1/2006|Medical| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| |Equipment Protection Class|Class I|See safety agency conditions of acceptability for details| ## **Applications Notes** ## **Output Derating** ## **Output Current Programming** **==> picture [202 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 3000<br>1500<br>90 180 264<br>Input Voltage (VAC)<br>Output Power (W)<br>**----- End of picture text -----**<br> **==> picture [158 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 110<br>100<br>80<br>60<br>40<br>20<br>0<br>0 1 2 3 4 5<br>Iprog (V)<br>Output Current (% of nominal)<br>**----- End of picture text -----**<br> ## **Output Voltage Programming** ## **Dielectric Strength Testing** **==> picture [158 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 105<br>100<br>80<br>60 weeecc eee eeeeeneeeeeeeney<br>40<br>20<br>0<br>0 1 2 3 4 5<br>Vprog (V)<br>Output Voltage (% of nominal)<br>**----- End of picture text -----**<br> This product includes Gas Discharge Tubes as part of the Surge Immunity counter-measures. This screw must be removed during dielectric strength testing in the end-equipment, to prevent flashover to Earth. Maximum applied voltage: Live and neutral to earth: 2100Vdc Input to Output: 2100Vdc Re-install the screw after testing. 5 AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **Signals & C** ~~**ontrols**~~ G ~~Q»~~ **Signal Connections** **==> picture [136 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> 29 30<br>1 2<br>**----- End of picture text -----**<br> |J1 Signal Connector Connections<br>~~OO~~|J1 Signal Connector Connections<br>~~OO~~|J1 Signal Connector Connections<br>~~OO~~|J1 Signal Connector Connections<br>~~OO~~| |---|---|---|---| |Pin<br>~~OO~~|Function<br>~~OO~~<br>~~—SSCSCsSC:és~~|Opto-isolator<br>~~—SSCSCsSC:és~~|Description<br>~~—SSCSCsSC:és~~| |1<br>~~OO~~|DCOK<br>~~OO~~<br>~~—SSCSCsSC:és~~|Collector<br>~~—SSCSCsSC:és~~|See circuit diagram on page 7.<br>Uncommited opto-isolator. Circuit conducting means Vout is within range.<br>~~—SSCSCsSC:és~~| |2|DCOK Return|Emitter|| |3|Remote Inhibit|Anode|See circuit diagram on page 7.<br>Uncommited opto-diode. Diode conducting means output OFF.| |4|Remote Inhibit Return|Cathode|| |5|A0||I2C Device Address Bit (Internal 10kΩpull-up to 3.3V)| |6|A1||I2C Device Address Bit (Internal 10kΩpull-up to 3.3V)| |7|A2||I2C Device Address Bit (Internal 10kΩpull-up to 3.3V)| |8|CANH||CAN Bus Communication using CANopen protocol| |9|RS485_Y||RS485 Differential Serial Bus Communication| |10|CANL||CAN Bus Communication using CANopen protocol| |11|RS485_Z||RS485 Differential Serial Bus Communication| |12|SGND||Signal Return| |13|UART_RX / RS232_RX/RS485_A||RS485 Differential Serial Bus Communication or RS232 Serial Bus Communication or UART| |14|I2C SDA||I2C (Internal 10kΩpull-up to 3.3V)| |15|UART_TX / RS232_TX/RS485_B||RS485 Differential Serial Bus Communication or RS232 Serial Bus Communication or UART| |16|I2C SCL||I2C Bus Clock (Internal 10kΩpull-up to 3.3V)| |17|FAN_FAIL/TEMP WARNING||Fan Failure/Temp Warning Reporting (High means fan fails and/or overtemperature rating;<br>10kΩpull up to 3.3V) See circuit diagram on page 7.| |18|SYNC||Connect parallel units to synchronise output turn on| |19|VPROG||0 to 5V to set Vout from 0 to 105%(1)(50.8kΩinternal resistance between Vprog and SGND(2))| |20|RS+||Positive Remote Sense| |21|RS-||Negative Remote Sense| |22|IPROG||0 to 5V to set Current Limit from 0 to110% of rated current(1)(50.8kΩinternal resistance between<br>Iprog and SGND)| |23|ISHARE||0 to 2.6V for current sharing of units in parallel| |24|PMBUS_EN||Selecting Digital (open) or Analog (low) mode for VPROG & IPROG (Internal 10kΩpull up to 3.3V)| |25|ACOK|Collector|See circuit diagram on page 7.<br>Uncommited opto-isolator. Circuit conducting means AC is within range.| |26|ACOK Return|Emitter|| |27|5VSBY||5V/2A Standby| |28|5VSBY||5V/2A Standby| |29|5VSBY_RTN||5V/2A Standby Return| |30|5VSBY_RTN||5V/2A Standby Return| ## **Notes:** 1. In analog mode, the default Vout and Iout settings are 0% when Vprog and Iprog are open circuit. 2. To activate analog mode, PMBus_EN must be pulled down to SGND. Default if left open is digital programming. Specifications subject to change without notice. 6 AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **Signals & Controls** **DC OK** **AC OK** **==> picture [507 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> 5V Standby 5V Standby<br>Pin 27/28 Pin 27/28<br>3K3 3K3<br>Pin 1 Pin 25<br>100R 15V 100R 15V<br>4mA max 4mA max<br>High: DC NOT OK High: AC NOT OK<br>Low: DC OK Low: AC OK<br>Pin 2 Pin 26<br>5V Standby 5V St a ndby<br>HoT R eturn eT Return<br>Pin 29/30 Pin 29/30<br>Fan Fail/Temperature Warning Inhibit<br>**----- End of picture text -----**<br> **==> picture [496 x 252] intentionally omitted <==** **----- Start of picture text -----**<br> Pin 29/30 Pin 29/30<br>Inhibit<br>5V Standby<br>3V3 Pin 27/28<br>511R<br>10K<br>Pin 17 Pin 3<br>Open/Floating: Power Supply ON<br>High: Power Supply OFF<br>0.5 mA min to inhibit<br>High: FAN NOT OK/Over Temperature 8mA max<br>Low: FAN OK/Temperature OK<br>3.3V TTL compatible Pin 4<br>Pin 12<br>SIGNAL GND 5V Standby<br>O M E Return<br>Pin 29/30<br>**----- End of picture text -----**<br> 7 AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **Signals & Controls** Ga» ## **Current Share** **==> picture [348 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> HPF3K0 HPF3K0 HPF3K0<br>V1 Output V1 Output V1 Output<br>Current Current<br>- + Share - + Share - +<br>Up to 5 x HPF3K0 units<br>Pin 23 Pin 23<br>E TIIIIt IIric L ]<br>Ral SGND Ealee SGND<br>Pin 12 Pin 12<br>YY<br>L - | OL +<br>Load<br>+ Sense - Sense<br>- Sense + Sense<br>- Sense + Sense<br>**----- End of picture text -----**<br> ## **LED Signals** GD |Conditions|LED State<br>~~ee~~|LED State<br>~~ee~~|Signals<br>~~ee~~|Signals<br>~~ee~~|Signals<br>~~ee~~|Signals<br>~~ee~~| |---|---|---|---|---|---|---| ||AC OK|DC OK|AC OK|DC OK|FAN _FAIL/<br>TEMP|Remote<br>Inhibit| |AC input OK|ON|ON(3)|Active|Active|Active Low|Inactive| |AC below control system startup<br>AC present but out of range or PFC|OFF<br>Blink (0.2s|OFF|Inactive|Inactive|Inactive|X(2)| |AC present but out of range or PFC<br>failure or no primary to secondary<br>communication<br>Output Over Voltage|ON, 0.2s<br>OFF)<br>ON|OFF<br>OFF|High<br>Active|High<br>Inactive|Low<br>Active Low|X(2)<br>Inactive| |Output Over Voltage<br>Current Limit (Constant current<br>response)<br>Fan Failure/Thermal Shutdown|ON<br>ON<br>ON|OFF<br>Blink<br>(0.2s ON, 0.2s OFF)<br>OFF|Active<br>Active<br>Active|Inactive<br>Active or<br>Inactive(3)<br>Inactive|Active Low<br>Active Low<br>Active High(1)|Inactive<br>Inactive<br>Inactive| |Fan Failure/Thermal Shutdown<br>Remote OFF|ON<br>ON|OFF<br>Blink<br>(1.0s ON, 1.0s OFF)|Active<br>Active|Inactive<br>Inactive|Active High(1)<br>Active Low|Inactive<br>Active| |PMBus Operation OFF|ON|Blink<br>(1.0s ON, 1.0s OFF)|Active|Inactive|Active Low|Inactive| ## **Notes:** 1. In case of fan failure, and/or Overtemperature, FAN_FAIL/Temp Warning signal will be set 10s before output shutdown. 2. Don’t care / not applicable. 3. DC OK LED is ON if Output Voltage >= VOUT_UV_FAULT_LIMIT, if Output Voltage < VOUT_UV_FAULT_LIMIT, the DC OK LED will be OFF. 8 Specifications subject to change without notice. AC-DC POWER SUPPLIES ## **HPF3K0** Series ## **Mechanical Details** **==> picture [530 x 594] intentionally omitted <==** **----- Start of picture text -----**<br> 2 x M4 mounting point,<br>4.0 max screw penetration<br>AC Input Terminal<br>31.8 Pitch: 13.0<br>(1.25)<br>Access width: 9.7<br>Screw: M4<br>Max torque: 1.1Nm<br>53.3 175.3<br>(2.10) (6.90) 17.5<br>(0.69)<br>279.4 15.3<br>(11.0) (0.60)<br>20.4<br>3.1 53.3 175.3 (0.80)<br>(0.12) (2.10) (6.90)<br>(<br>45.1<br>(1.77)<br>4 x M5 Screw<br>AIR FLOW DC OUT Terminal<br>177.8 88.9<br>(7.00) (3.50) 26.1<br>(1.03)<br>See table for<br>logic output<br>connector details<br>32.8<br>(1.29)<br>17.7<br>(0.70)<br>14.0<br>(0.55)<br>63.5<br>(2.50)<br>4 x M4 mounting point<br>4.0 max screw penetration<br>Pin Function Pin Function<br>1 DCOK 16 I2C_SCL<br>2 DCOK_RTN 17 FAN_FAIL<br>3 RMT_INH 18 SYNC<br>4 RMT_INH_RTN 19 VPROG<br>5 I2C_A0 20 RS+<br>6 I2C_A1 21 RS-<br>7 I2C_A2 22 IPROG<br>8 CANH 23 ISHARE<br>9 RS485_Y 24 PMBUS_EN<br>10 CANL 25 ACOK<br>11 RS485_Z 26 ACOK_RTN<br>12 SGND 27 5VSBY<br>13 RS232_RX/RS485_A 28 5VSBY<br>14 I2C_SDA 29 5VSBY_RTN<br>2 x<br>15 RS232_TX/RS485_B 30 5VSBY_RTN 60 x 38mm<br> FAN<br>1 29<br>2 30<br>**----- End of picture text -----**<br> 4 x M4 mounting point 4.0 max screw penetration ## **Notes:** 1. All dimensions are in mm (inches). 2. Weight 4.0kg (8.8lbs). 3. Signal Connector: JST part S30B-PUDSS-1 or equivalent. Mates with JST part PUDP-30V-S or equivalent. Contacts: SPUD-001T-P0.5 (26-22AWG), SPUD 002T-P0.5 (28-24AWG). **==> picture [148 x 49] intentionally omitted <==** 9 25 Oct 2023
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →