HP515A6
RESET TIMER, 60HZ, 120VAC, 0.5S
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: VEEDER ROOT
- Product type: Analogue Timers
- Time Max: 10s
- Time Min: 0.33s
- Timer Output: Solid State
- Product Range: HP5 Series
- Timer Functions: Reset
- Current Rating Nom: 10A
- Supply Voltage Max: 120VAC
- No. of Timing Ranges: 1Ranges
- Connection / Termination: Plug-In
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 737.28 € |
| Current stock | 10+ |
| Lead time | 30 days |
**EAGLE SIGNAL Electric Timers** **E L T E I C M T E R R I S C** ## **HP5 CYCL-FLEX[®] Reset Timer** **The high quality timer that has become an industry standard... knob setpoint, cycle progress pointer, pilot light, and patented plug-in housing** - **6** Also see Series HP5E in Section 5 for SolidState Model The HP5 CYCL-FLEX[®] series timer is a high quality, synchronous motor driven reset timer housed in the standard CYCL-FLEX[®] plug-in housing. - I 16 standard time ranges from 5 seconds to 60 hours - I Knob adjustable time ranges - progress pointer for each - I Highly visible, calibrated dials (7.85 inch circumference) - I Easily read and well-spaced calibrations - I Red progress pointer displays remaining time interval - I Pilot light indicates when timer motor is energized - I Standard timers supplied with "power on" clutch operation - I Optional reverse action clutch will not reset on power failure - I 15 terminal ABS (UL rated 94V-0) molded housing has high impact resistance and will not support combustion **==> picture [108 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> ® F M<br>®<br>RECOGNIZED CERTIFIED A P P R O V E D<br>**----- End of picture text -----**<br> ## **Time Ranges Cont.:** |**Sym.**|**Dial**|**Minimum**<br>**Setting**|**Dial**<br>**Divisions**|**Repeat**<br>**Accuracy**| |---|---|---|---|---| |18|15 Min.|30 Sec.|15 Sec.|±4.5 Sec.| |5|30 Min.|1 Min.|1/2 Min.|±9 Sec.| |6|60 Min.|2 Min.|1 Min.|±18 Sec.| |7|150 Min.|4.5 Min.|2 Min.|±45 Sec.| |8|5 Hr.|9 Min.|3 Min.|±1.5 Min.| |9|10 Hr.|20 Min.|10 Min.|±3 Min.| |10|30 Hr.|1 Hr.|1/2 Hr.|±9 Min.| |11|60 Hr.|2 Hr.|1 Hr.|±18 Min.| **Reset Time:** 1/2 second at max. setting ## **OPERATION** Application of power to terminals 1, 2, and 11 energizes the clutch coil, closes contacts 9-10 and 6-8, and starts the timing period. At time out, contacts 4-3 close, 11-12 open, and the motor stops. The timer will remain in this condition until power is removed from the clutch coil. Contacts 6-7-8 and 9-10-C are instantaneous contacts and operate with the application of power to the clutch coil. Contacts 3-4-5 and 11-12-A operate at time out with contacts 3-4-5 operating prior to contacts 11-12-A. **Voltage/Frequency:** 120V (+10, -15%), 60 Hz 240V (+10, -15%), 60 Hz **Burden:** Motor: 2.45 VA, 120 VAC Clutch: 10.5 VA **Output Rating:** 10 amps, resistive, 120 VAC 5 amps, resistive, 240 VAC **Electrical Lifetime:** Contingent on load characteristics. Average contact life at full load is 250,000 operations. At 1 amp load, switch life increases to 5 million cycles. Inrush current should not exceed 10 amps. **Power On Response:** 28 ms average pull-in 17 ms average drop-out ## **SPECIFICATIONS** ## **Time Ranges:** |**Sym.**|**Dial**<br>**Minimum**<br>**Setting**|**Minimum**<br>**Setting**<br>**Dial**<br>**Divisions**|**Repeat**<br>**Accuracy**| |---|---|---|---| |17|5 Sec.<br>1/6 Sec.|1/6 Sec.<br>.05 Sec.|±.05 Sec.| |15|10 Sec.<br>1/3 Sec.|1/3 Sec.<br>1/6 Sec.|±.05 Sec.| |14|15 Sec.<br>1/2 Sec.|1/2 Sec.<br>1/4 Sec.|±.08 Sec.| |0|30 Sec.<br>1 Sec.|1 Sec.<br>1/2 Sec.|±.15 Sec.| |1|60 Sec.<br>2 Sec.|2 Sec.<br>1 Sec.|±.3 Sec.| |2|150 Sec.<br>4.5 Sec.|4.5 Sec.<br>2 Sec.|±.75 Sec.| |3|5 Min.<br>9 Sec.|9 Sec.<br>3 Sec.|±1.5 Sec.| |4|10 Min.<br>20 Sec.|20 Sec.<br>10 Sec.|±3 Sec.| **Temperature Range:** 0˚ to 140˚F (-18˚ to +60˚C) **Vibration:** Unaffected by 2.5G sinusoidal vibration magnitudes in both directions of three perpendicular mounting axes imposed from 10 to 900 Hz **Approximate Weight:** 2 lb. 14 oz. **Agency Approvals:** UL Recognition E61735 UL Recognition 71726 (Feature 92 only) CSA Certification LR26861 CSA Certification (Feature 92 only) FM Approval 15030 RoHS 6.08 **DANAHER SENSORS & CONTROLS** **6** **T OE TL T AE I LC M IT E ZRI RS IC N G** **==> picture [576 x 39] intentionally omitted <==** ## **OPERATION** ## **Standard and Reverse Start** Instantaneous contacts 9-10-C and 6-7-8 operate directly with the clutch offering different sequences of operation depending on the control circuit configuration. Delayed contacts 4-3 and 11-A close and contacts 4-5 and 11-12 open when timer reaches a timed out condition. Contacts 4-5 and 11-12 close and contacts 4-3 and 11-A open when timer is reset. ## **Schematic Diagram** **==> picture [112 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2<br>M<br>A<br>11<br>10<br>12<br>9<br>3<br>C<br>4<br>8<br>6 5<br>7<br>**----- End of picture text -----**<br> ## **ENCLOSURES** |**Model No.**|**NEMA Class**|**Description**| |---|---|---| |**HN308**<br>**HN364**|1<br>1|Surface Mtg. with terminal block<br>Surface Mtg. without terminal block| |**HN368**|!A|Dual unit cabinet with 9 position| |||terminal block, timer housings, and| |||DPST toggle switch| |**HN370**|1A|Dual unit cabinet less unit cases and| |||toggle switch, with 9 terminal block| ## **ACCESSORIES** ||**Model No.**|**Description**| |---|---|---| ||**H-5331**|Mounting Brackets 2 req'd per timer| ||**HP50-31**|One Hole Mounting Ring| ||**HP50-103**|120 VAC, 50/60 Hz Repeat Cycle Kit| |||Not applicable with Feature 19| ||**HP50-131**<br>**HP50-133**|CYCL-FLEX®Water-Sealed Housing<br>Surface Mounting Adapter to use in place of brackets| ||**HP50-295**|Dial Lock| ## **MOUNTING** **==> picture [289 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> DRILL AND TAP FOUR<br>HOLES FOR 8-32 SCREWS<br>(INCLUDED W/UNIT)<br>1.406 3.187 +.062<br>(35.71) (80.95 +1.57)<br>DIA. CUTOUT<br>4.250<br>(107.95)<br>1.406<br>(35.71)<br>1.406 1.406 MTG. HOLE<br>(35.71) (35.71) USED FORGROUNDING<br>CASE 3.812<br>(96.82)<br>**----- End of picture text -----**<br> **==> picture [170 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> 3.062<br>(77.77)<br>4.125 1.625<br>(104.78) (41.27)<br>5.750<br>(146.05)<br>**----- End of picture text -----**<br> ## **ORDERING INFORMATION** ## **HP5 15 A6 01** ||||||||||Reverse Clutch Arrangement<br>Dial Lock<br>Revision for Mtg. to HN383 Explosion Proof<br>Cabinet. Add when purchased without<br>cabinet. DOES NOT have pilot light.<br>Water Resistant Window & Housing<br>Enclosed in HN383 Explosion Proof Cabinet<br>**Description**<br>01<br>07<br>19<br>22<br>92*<br>**Sym.**<br>**FEATURES**||Reverse Clutch Arrangement<br>Dial Lock<br>Revision for Mtg. to HN383 Explosion Proof<br>Cabinet. Add when purchased without<br>cabinet. DOES NOT have pilot light.<br>Water Resistant Window & Housing<br>Enclosed in HN383 Explosion Proof Cabinet<br>**Description**<br>01<br>07<br>19<br>22<br>92*<br>**Sym.**<br>**FEATURES**|Reverse Clutch Arrangement<br>Dial Lock<br>Revision for Mtg. to HN383 Explosion Proof<br>Cabinet. Add when purchased without<br>cabinet. DOES NOT have pilot light.<br>Water Resistant Window & Housing<br>Enclosed in HN383 Explosion Proof Cabinet<br>**Description**<br>01<br>07<br>19<br>22<br>92*<br>**Sym.**<br>**FEATURES**| |---|---|---|---|---|---|---|---|---|---|---|---|---| |**TIME RANGE**||||||||||||| |**Sym.**|**Description**|**Sym.**|**Description**|||||||||**Description**| |||||||||||||| |17|0-5 Sec.|18|0-15 Min.|||||||||Reverse Clutch Arrangement| |15|0-10 Sec.|5|0-30 Min.|||||||||Dial Lock| |14|0-15 Sec.|6|0-60 Min.|||||||||Revision for Mtg. to HN383 Explosion Proof| |||||||**Sym.**|**Description**|||||| |0|0-30 Sec.|7|0-150 Min.|||||||||Cabinet. Add when purchased without<br>cabinet. DOES NOT have pilot light.<br>Water Resistant Window & Housing| |1|0-60 Sec.|8|0-5 Hr.|||A6<br>B6|120V, 60 Hz|||||| |2|0-150 Sec.|9|0-10 Hr.||||240V, 60 Hz|||||| |3|0-5 Min.|10|0-30 Hr.|||||||||Enclosed in HN383 Explosion Proof Cabinet| |4|0-10 Min.|11|0-60 Hr.|||||||||| |||||**HP5**| |---|---|---|---|---| |**TIME RANGE**||||| ||**Sym.**|**Description**|**Sym.**|**Description**| ||17<br>15|0-5 Sec.<br>0-10 Sec.|18<br>5|0-15 Min.<br>0-30 Min.| ||14<br>0|0-15 Sec.<br>0-30 Sec.|6<br>7|0-60 Min.<br>0-150 Min.| ||1|0-60 Sec.|8|0-5 Hr.| ||2|0-150 Sec.|9|0-10 Hr.| ||3|0-5 Min.|10|0-30 Hr.| ||4|0-10 Min.|11|0-60 Hr.| ||**FEATURES**|**FEATURES**|**FEATURES**| |---|---|---|---| |||**Sym.**|**Description**| |||01<br>07|Reverse Clutch Arrangement<br>Dial Lock| |||19|Revision for Mtg. to HN383 Explosion Proof<br>Cabinet. Add when purchased without| ||||cabinet. DOES NOT have pilot light.| |||22|Water Resistant Window & Housing| |||92*|Enclosed in HN383 Explosion Proof Cabinet| *Laboratory Testing: UL Recognition E61735 CSA Certification LR45132-1 **DANAHER SENSORS & CONTROLS** 6.09
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →