Image not available
Illustrative purposes only
HLG-60H-C700A
LED Driver, LED Lighting, 70 W, 100 V, 700 mA, Constant Current, 90 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HLG-60H-C Series
- Output Current: 700mA
- LED Driver Mode: Constant Current
- Output Power Max: 70W
- Input Voltage Max: 305VAC
- Input Voltage Min: 90VAC
- Output Voltage Max: 100V
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 26.68 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HLG - 60H - C series** 70W Constant Current Mode LED Driver **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> > ** ** ** IP65 IP67** ~~A~~ VVY ## ■ **** - ‧ - ‧Ⅰ - ‧ - ‧ - ‧ - - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ■ **** ## ■ **** ~ ℃℃ |■ ****|■ ****|■ ****|| |---|---|---|---| |****<br>****<br>****<br><br><br><br><br>~~=~~<br>mac|||| ||||| |||<br>|| |A||<br>|| |||<br>|| |||<br><br>I|| |||<br>|| _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** 70W Constant Current Mode LED Driver ## **SPECIFICATION** ||**MODEL**<br>**RATED CURRENT**<br>**CURRENT TOLERANCE**<br>**CURRENT RIPPLE**<br>**RATED POWER**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDSNote.6**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>750ms/115VAC, 500ms/230VAC<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,<br>EAC TP TC 020<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, heavy industry level (surge immunity Line-Earth 4KV,<br>Line-Line 2KV), EAC TP TC 020<br>10 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>3113.4K hrs min. Telcordia SR-332 (Bellcore) ; 336.0K hrs min. MIL-HDBK-217F (25℃)<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>Shut down o/p voltage, re-power on to recover<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>±5%<br>5.0% max. @rated current<br>**EMC IMMUNITY**<br>**EMC EMISSION Note.6**<br>COLD START 60A(twidth=275 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CONSTANT CURRENT REGIONNote.2**<br>**PACKING**<br>**NOTE**<br>μ<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>8 units (circuit breaker of type B) / 13 units (circuit breaker of type C) at 230VAC<br>**VOLTAGE RANGENote.3** 90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>**OUTPUT**<br>**POWER FACTOR (Typ.)**<br>**TOTAL HARMONIC DISTORTION**<br>**INPUT**<br>**WORKING TEMP.**<br>Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>**MAX. CASE TEMP.**<br>Tcase=+80℃<br>℃<br><br><br><br><br><br><br><br>℃<br><br>℃℃<br><br><br>※Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>PF<br>0.9 /<br>VAC, PF<br>0.96/2<br>VAC<br>full load<br>≧<br>8 115<br>≧<br>30<br>, PF≧0.94/277VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>THD< 20% (@ load≧60% /115VAC, 230VAC; @ load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)<br>210 ~ 350mA<br>420 ~ 700mA<br>**HLG-60H-C350**<br>**HLG-60H-C700**<br>350mA<br>700mA<br>70W<br>70W<br>100 ~ 200V<br>50 ~ 100V<br>91%<br>90.5%<br>0.69A / 115VAC 0.35A / 230VAC 0.29A / 277VAC<br>Hiccup mode, recovers automatically after fault condition is removed<br>230 ~ 250V<br>120 ~ 140V<br>UL8750, CSA C22.2 No. 250.0-08,<br>independent,<br>BS EN/EN 61347-1,BS EN/EN 61347-2-13<br>,<br>GB19510.1,GB19510.14<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>171*61.5*36.8 mm (L*W*H)<br>0.73Kg; 20pcs/15.6Kg/0.9CUFT<br>approved<br>EAC TP TC 004,IP65 or IP67|**MODEL**<br>**RATED CURRENT**<br>**CURRENT TOLERANCE**<br>**CURRENT RIPPLE**<br>**RATED POWER**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDSNote.6**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>750ms/115VAC, 500ms/230VAC<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,<br>EAC TP TC 020<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, heavy industry level (surge immunity Line-Earth 4KV,<br>Line-Line 2KV), EAC TP TC 020<br>10 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>3113.4K hrs min. Telcordia SR-332 (Bellcore) ; 336.0K hrs min. MIL-HDBK-217F (25℃)<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>Shut down o/p voltage, re-power on to recover<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>±5%<br>5.0% max. @rated current<br>**EMC IMMUNITY**<br>**EMC EMISSION Note.6**<br>COLD START 60A(twidth=275 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CONSTANT CURRENT REGIONNote.2**<br>**PACKING**<br>**NOTE**<br>μ<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>8 units (circuit breaker of type B) / 13 units (circuit breaker of type C) at 230VAC<br>**VOLTAGE RANGENote.3** 90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>**OUTPUT**<br>**POWER FACTOR (Typ.)**<br>**TOTAL HARMONIC DISTORTION**<br>**INPUT**<br>**WORKING TEMP.**<br>Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>**MAX. CASE TEMP.**<br>Tcase=+80℃<br>℃<br><br><br><br><br><br><br><br>℃<br><br>℃℃<br><br><br>※Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>PF<br>0.9 /<br>VAC, PF<br>0.96/2<br>VAC<br>full load<br>≧<br>8 115<br>≧<br>30<br>, PF≧0.94/277VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>THD< 20% (@ load≧60% /115VAC, 230VAC; @ load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)<br>210 ~ 350mA<br>420 ~ 700mA<br>**HLG-60H-C350**<br>**HLG-60H-C700**<br>350mA<br>700mA<br>70W<br>70W<br>100 ~ 200V<br>50 ~ 100V<br>91%<br>90.5%<br>0.69A / 115VAC 0.35A / 230VAC 0.29A / 277VAC<br>Hiccup mode, recovers automatically after fault condition is removed<br>230 ~ 250V<br>120 ~ 140V<br>UL8750, CSA C22.2 No. 250.0-08,<br>independent,<br>BS EN/EN 61347-1,BS EN/EN 61347-2-13<br>,<br>GB19510.1,GB19510.14<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>171*61.5*36.8 mm (L*W*H)<br>0.73Kg; 20pcs/15.6Kg/0.9CUFT<br>approved<br>EAC TP TC 004,IP65 or IP67|**HLG-60H-C350**|**HLG-60H-C700**| |---|---|---|---|---| |||**RATED CURRENT**|350mA|700mA| |||**RATED POWER**|70W|70W| |||**CONSTANT CURRENT REGIONNote.2**|100 ~ 200V|50 ~ 100V| |||**CURRENT ADJ. RANGE**|Adjustable for A/AB-Type only (via built-in potentiometer)<br>210 ~ 350mA<br>420 ~ 700mA|| |||**CURRENT RIPPLE**|5.0% max. @rated current|| |||**CURRENT TOLERANCE**|±5%|| |||**SET UP TIME Note.4**|750ms/115VAC, 500ms/230VAC|| |||**VOLTAGE RANGENote.3**|90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)|| |||**FREQUENCY RANGE**|47 ~ 63Hz|| |||**POWER FACTOR (Typ.)**|PF<br>0.9 /<br>VAC, PF<br>0.96/2<br>VAC<br>full load<br>≧<br>8 115<br>≧<br>30<br>, PF≧0.94/277VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section|| |||**TOTAL HARMONIC DISTORTION**|THD< 20% (@ load≧60% /115VAC, 230VAC; @ load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)|| |||**EFFICIENCY (Typ.)**|91%|90.5%| |||**AC CURRENT (Typ.)**|0.69A / 115VAC 0.35A / 230VAC 0.29A / 277VAC|| |||**INRUSH CURRENT(Typ.)**|COLD START 60A(twidth=275 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>μ|| |||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|8 units (circuit breaker of type B) / 13 units (circuit breaker of type C) at 230VAC|| |||**LEAKAGE CURRENT**|<0.75mA / 277VAC|| |||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed|| |||**OVER VOLTAGE**|Shut down o/p voltage with auto-recovery or re-power on to recovery<br>230 ~ 250V<br>120 ~ 140V|| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|| |||**WORKING TEMP.**|Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)|| |||**MAX. CASE TEMP.**|Tcase=+80℃|| |||**WORKING HUMIDITY**|10 ~ 95% RH non-condensing|| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|| |||**SAFETY STANDARDSNote.6**|UL8750, CSA C22.2 No. 250.0-08,<br>independent,<br>BS EN/EN 61347-1,BS EN/EN 61347-2-13<br>,<br>GB19510.1,GB19510.14<br>approved<br>EAC TP TC 004,IP65 or IP67|| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|| |||**EMC EMISSION Note.6**|Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,<br>EAC TP TC 020|| |||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, heavy industry level (surge immunity Line-Earth 4KV,<br>Line-Line 2KV), EAC TP TC 020|| |||**MTBF**|<br>3113.4K hrs min. Telcordia SR-332 (Bellcore) ; 336.0K hrs min. MIL-HDBK-217F (25℃)|| |||**DIMENSION**|171*61.5*36.8 mm (L*W*H)|| |||**PACKING**|0.73Kg; 20pcs/15.6Kg/0.9CUFT|| |||℃<br><br><br><br><br><br><br><br>℃<br><br>℃℃<br><br><br>※Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx||| _File Name:HLG-60H-C-SPEC 2022-04-15_ ## 70W Constant Current Mode LED Driver ## **HLG - 60H - C series** ## **BLOCK DIAGRAM** **==> picture [471 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 60KHz<br>PWM fosc : 80KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>(B Type)<br>O.T.P. O.L.P. DETECTION<br>FG<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series works in constant current mode to directly drive the LEDs. **==> picture [202 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>(A)<br>Constant<br>Current area<br>50<br>(min.)<br>(B)<br>Hiccup<br>Protection<br>50 100 Io (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Typical output current normalized by rated current (%) _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** 70W Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [499 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> +V(Brown)<br>AC/L(Brown) -V(Blue)<br>AC/N(Blue) HLG-60H-C<br>FG (Green/Yellow) DIM+(Purple)<br>DIM-(Pink)<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function (for B/AB-Type)** - ‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: - 1 ~ 10VDC, or 10V PWM signal or resistance. - ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. ‧Dimming source current from power supply: 100μA (typ.) ◎ Applying additive 1 ~ 10VDC **==> picture [157 x 469] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive resistance: **==> picture [214 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** ## 70W Constant Current Mode LED Driver Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options. **==> picture [401 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> N FG L<br>Relay Switch Adjuster<br>10K/N~100K/N Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Purple<br>Green/ DIM+ Pink<br>Yellow AC/L HLG-60H-C DIM- Blue<br>Brown AC/N B-Type V(-)V(+) Brown LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** 70W Constant Current Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE(Note.8)** **==> picture [502 x 587] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 30 40 50 70 80 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 70℃<br>1.02<br>100<br>1<br>90 0.98<br>0.96<br>80<br>0.94 277V<br>70 0.92 230V<br>60 0.9 115V<br>0.88<br>50<br>0.86<br>40 0.84<br>50% 60% 70% 80% 90% 100%<br>(70W)<br>90 100 125 135 145 155 165 175 180 200 230 305<br>LOAD<br>INPUT VOLTAGE (V) 60Hz<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>HLG-60H-C series possess superior working efficiency that up to 91% can<br>※ 350mA Model, Tcase at 70℃ be reached in field applications.<br>※ 350mA Model, Tcase at 70℃<br>40<br>100%<br>35 90%<br>30 80%<br>25 70%<br>20 277VAC 60%<br>15 230VAC 50% 277V<br>10 115VAC 40% 230V<br>5 30% 115V<br>20%<br>0<br>10%<br>50% 60% 70% 80% 90% 100%<br>0%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** 70W Constant Current Mode LED Driver ## **LIFE TIME** **==> picture [329 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80<br>Tcase ( ℃ )<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:HLG-60H-C-SPEC 2022-04-15_ ## 70W Constant Current Mode LED Driver ## **HLG - 60H - C series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.957 Unit:mm<br>※ A-Type<br>171<br>11.9 147.2<br>9.6<br>300±20 300±20<br>AC/L(Brown) 73.6 +V(Brown)<br>AC/N(Blue)FG (Green/Yellow)SJOW 17AWG&H05RN-F 1.0mm ×2 3C tc Io SJOW 17AWG&H05RN-F 1.0mm ×2 2C -V(Blue)<br>ADJ<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ B-Type<br>171<br>11.9 147.2<br>9.6 300±20<br>300±20 SJOW 17AWG&H05RN-F 1.0mm ×2 2C +V(Brown)<br>AC/L(Brown)AC/N(Blue)FG (Green/Yellow)SJOW 17AWG&H05RN-F 1.0mm ×2 3C tc 73.6 SJOW 17AWG&H05RN-F 1.0mm ×2 2C -V(Blue)DIM+(Purple)<br>DIM-(Pink)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>**----- End of picture text -----**<br> _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** 70W Constant Current Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>171<br>11.9 147.2<br>9.6 300±20<br>300±20 SJOW 17AWG&H05RN-F 1.0mm ×2 2C +V(Brown)<br>AC/L(Brown)AC/N(Blue)FG (Green/Yellow)SJOW 17AWG&H05RN-F 1.0mm ×2 3C tc ADJ73.6Io SJOW 17AWG&H05RN-F 1.0mm ×2 2C -V(Blue)DIM+(Purple)DIM-(Pink)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ D-Type<br>171<br>11.9 147.2<br>9.6<br>300±20 300±20<br>AC/L(Brown) 73.6 +V(Brown)<br>AC/N(Blue)FG (Green/Yellow)SJOW 17AWG&H05RN-F 1.0mm ×2 3C tc SJOW 17AWG&H05RN-F 1.0mm ×2 2C -V(Blue)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>**----- End of picture text -----**<br> _File Name:HLG-60H-C-SPEC 2022-04-15_ **HLG - 60H - C series** ## 70W Constant Current Mode LED Driver ## **WATERPROOF CONNECTION** ◎ Waterproof connector Waterproof connector can be assembled on the output cable of HLG-60H-C to operate in dry/wet/damp or outdoor environment. **==> picture [462 x 415] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>HLG-60H-C<br>source I/P O/P<br>Size Pin Configuration (Female) Size Pin Configuration (Female)<br>M12 M15<br>4-PIN 5-PIN 2-PIN<br>5A/PIN 5A/PIN 12A/PIN<br>Order No. M12-04 M12-05 Order No. M15-02<br>Suitable Current 10A max. 10A max. Suitable Current 12A max. LED Lamp<br>◎ Cable Joiner<br>CJ04-1 suitable for 14AWG~16AWG<br>66<br>CJ04-2 suitable for 18AWG~22AWG<br>26 20<br>Up to four wires can be connected through this cable joiner by<br>soldering or clamping by tools.<br>LED Lamp<br>HLG-60H-C<br>O/P Wires<br>※CJ04 cable joiner can be purchased independently for user's own assembly.<br> MEAN WELL order No. : CJ04-1, CJ04-2.<br>25<br>ψ<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to **:** http://www.meanwell.com/manual.html _File Name:HLG-60H-C-SPEC 2022-04-15_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →