HLG-40H-15A
LED Driver, Household & LED Lighting, 40.05 W, 17 V, 2.67 A, Constant Current, Constant Voltage
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HLG-40H Series
- Output Current: 2.67A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 40.05W
- Input Voltage Max: 305VAC
- Input Voltage Min: 90VAC
- Output Voltage Max: 17V
- Power Supply Applications: Household & LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 21.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HLG - 40H series** 40W Constant Voltage + Constant Current LED Driver **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> ## ** IP65 IP67** V7V ® [Ws **** (except for AB-type) ## ■ **** - ‧ - ‧Metal housing with class I design - ‧ - ‧ - ‧ - - - ‧ - ‧ **==> picture [61 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>(except for B/AB/D-type)<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧Ⅰ - ## ■ **** - ## ■ **** ~ ■ ** ** ~~_ __ oo~~ |<br>||<br>||<br>|| |---|---|---|---| |||I|| |||I|| |B|||| |||<br>I|| |D|||| _File Name:HLG-40H-SPEC 2022-02-18_ 40W Constant Voltage + Constant Current LED Driver ## **HLG - 40H series** ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDSNote.8**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>47 ~ 63Hz<br>0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC<br><0.75mA / 277VAC<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 60℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>3395.8K hrs min. Telcordia SR-332 (Bellcore) ; 345.8K hrs min. MIL-HDBK-217F (25℃)<br>171*61.5*36.8mm (L*W*H)<br>0.73Kg; 20pcs/15.6Kg/0.9CUFT<br>Shut down o/p voltage, re-power on to recover<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**CONSTANT CURRENT REGIONNote.4**<br>18 ~ 24V<br>15 ~ 21V<br>23 ~ 30V<br>28 ~ 35V<br>35 ~ 43V<br>41 ~ 49V<br>48 ~ 58V<br>59 ~ 68V<br>54 ~ 65V<br>86.5%<br>86.5%<br>88%<br>88%<br>88.5%<br>88.5%<br>89.5%<br>88.5%<br>89.5%<br>±2.5%<br>2 ~ 3.33A<br>±2.0%<br>1.6 ~ 2.67A<br>±1.0%<br>1.2 ~ 2A<br>±1.0%<br>1 ~ 1.67A<br>±1.0%<br>0.8 ~ 1.34A<br>±1.0%<br>0.67 ~ 1.12A<br>±1.0%<br>0.5 ~ 0.84A<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>0.45 ~ 0.75A<br>±0.5%<br>±0.5%<br>±1.0%<br>0.58 ~ 0.96A<br>±0.5%<br>±0.5%<br>12V<br>**HLG-40H-12**<br>**HLG-40H-15**<br>**HLG-40H-20**<br>**HLG-40H-24**<br>**HLG-40H-30**<br>**HLG-40H-36**<br>**HLG-40H-42**<br>**HLG-40H-48**<br>**HLG-40H-54**<br>7.2 ~12V<br>15V<br>9 ~ 15V<br>20V<br>12 ~ 20V<br>24V<br>14.4 ~ 24V<br>30V<br>18 ~ 30V<br>36V<br>21.6 ~ 36V<br>48V<br>28.8 ~ 48V<br>3.33A<br>2.67A<br>2A<br>1.67A<br>1.34A<br>1.12A<br>0.84A<br>39.96W<br>40.05W<br>40W<br>40.08W<br>40.2W<br>40.32W<br>40.32W<br>150mVp-p<br>150mVp-p<br>13.5 ~ 17V<br>150mVp-p<br>17 ~ 22V<br>200mVp-p<br>22 ~ 27V<br>200mVp-p<br>27 ~ 33V<br>200mVp-p<br>33 ~ 40V<br>300mVp-p<br>44 ~ 53V<br>10.8 ~ 13.5V<br>54V<br>32.4 ~ 54V<br>0.75A<br>40.5W<br>300mVp-p<br>49 ~ 58V<br>42V<br>25.2 ~ 42V<br>0.96A<br>40.32W<br>200mVp-p<br>40 ~ 46V<br>Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>≧60%) ; BS EN/EN61000-3-3,GB17743 and GB17625.1,<br>@ load<br>EAC TP TC 020<br>**EMC IMMUNITY**<br>**EMC EMISSIONNote.8**<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>16ms / 115VAC, 230VAC<br>500ms,80ms/115VAC 500ms,80ms/230VAC<br>THD< 20% (@ load<br>60% / 115VAC,230VAC; @ load<br>75% / 277VAC)<br>≧<br>≧<br>(Please refer to TOTAL HARMONIC DISTORTION (THD) section)<br>"<br>"<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load<br>(Please refer to "<br>" section)<br>POWER FACTOR (PF) CHARACTERISTIC<br>**MAX. CASE TEMP.**<br>Tcase=+80℃<br>Tcase=-40 ~ +80℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>℃ <br><br><br><br><br><br><br><br><br><br>℃<br><br>℃℃<br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>_File Name:HLG-40H-SPEC 2022-02-18_<br>UL8750(type”HL”), CSA C22.2 No. 250.0-08 ,<br>independent ,<br>BS EN/EN/AS/NZS 61347-1,BS EN/EN/AS/NZS 61347-2-13<br>GB19510.1,GB19510.14,EAC TP TC 004,KC61347-1,KC61347-2-13<br>IP65 or IP67 approved ;<br>(except for AB-type),<br>J61347-1 J61347-2-13 (except for B,AB and D-type)<br>,<br>; design refer to BS EN/EN60335-1(by request)<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024,<br>light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDSNote.8**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>47 ~ 63Hz<br>0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC<br><0.75mA / 277VAC<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 60℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>3395.8K hrs min. Telcordia SR-332 (Bellcore) ; 345.8K hrs min. MIL-HDBK-217F (25℃)<br>171*61.5*36.8mm (L*W*H)<br>0.73Kg; 20pcs/15.6Kg/0.9CUFT<br>Shut down o/p voltage, re-power on to recover<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**CONSTANT CURRENT REGIONNote.4**<br>18 ~ 24V<br>15 ~ 21V<br>23 ~ 30V<br>28 ~ 35V<br>35 ~ 43V<br>41 ~ 49V<br>48 ~ 58V<br>59 ~ 68V<br>54 ~ 65V<br>86.5%<br>86.5%<br>88%<br>88%<br>88.5%<br>88.5%<br>89.5%<br>88.5%<br>89.5%<br>±2.5%<br>2 ~ 3.33A<br>±2.0%<br>1.6 ~ 2.67A<br>±1.0%<br>1.2 ~ 2A<br>±1.0%<br>1 ~ 1.67A<br>±1.0%<br>0.8 ~ 1.34A<br>±1.0%<br>0.67 ~ 1.12A<br>±1.0%<br>0.5 ~ 0.84A<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>0.45 ~ 0.75A<br>±0.5%<br>±0.5%<br>±1.0%<br>0.58 ~ 0.96A<br>±0.5%<br>±0.5%<br>12V<br>**HLG-40H-12**<br>**HLG-40H-15**<br>**HLG-40H-20**<br>**HLG-40H-24**<br>**HLG-40H-30**<br>**HLG-40H-36**<br>**HLG-40H-42**<br>**HLG-40H-48**<br>**HLG-40H-54**<br>7.2 ~12V<br>15V<br>9 ~ 15V<br>20V<br>12 ~ 20V<br>24V<br>14.4 ~ 24V<br>30V<br>18 ~ 30V<br>36V<br>21.6 ~ 36V<br>48V<br>28.8 ~ 48V<br>3.33A<br>2.67A<br>2A<br>1.67A<br>1.34A<br>1.12A<br>0.84A<br>39.96W<br>40.05W<br>40W<br>40.08W<br>40.2W<br>40.32W<br>40.32W<br>150mVp-p<br>150mVp-p<br>13.5 ~ 17V<br>150mVp-p<br>17 ~ 22V<br>200mVp-p<br>22 ~ 27V<br>200mVp-p<br>27 ~ 33V<br>200mVp-p<br>33 ~ 40V<br>300mVp-p<br>44 ~ 53V<br>10.8 ~ 13.5V<br>54V<br>32.4 ~ 54V<br>0.75A<br>40.5W<br>300mVp-p<br>49 ~ 58V<br>42V<br>25.2 ~ 42V<br>0.96A<br>40.32W<br>200mVp-p<br>40 ~ 46V<br>Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>≧60%) ; BS EN/EN61000-3-3,GB17743 and GB17625.1,<br>@ load<br>EAC TP TC 020<br>**EMC IMMUNITY**<br>**EMC EMISSIONNote.8**<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>16ms / 115VAC, 230VAC<br>500ms,80ms/115VAC 500ms,80ms/230VAC<br>THD< 20% (@ load<br>60% / 115VAC,230VAC; @ load<br>75% / 277VAC)<br>≧<br>≧<br>(Please refer to TOTAL HARMONIC DISTORTION (THD) section)<br>"<br>"<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load<br>(Please refer to "<br>" section)<br>POWER FACTOR (PF) CHARACTERISTIC<br>**MAX. CASE TEMP.**<br>Tcase=+80℃<br>Tcase=-40 ~ +80℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>℃ <br><br><br><br><br><br><br><br><br><br>℃<br><br>℃℃<br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>_File Name:HLG-40H-SPEC 2022-02-18_<br>UL8750(type”HL”), CSA C22.2 No. 250.0-08 ,<br>independent ,<br>BS EN/EN/AS/NZS 61347-1,BS EN/EN/AS/NZS 61347-2-13<br>GB19510.1,GB19510.14,EAC TP TC 004,KC61347-1,KC61347-2-13<br>IP65 or IP67 approved ;<br>(except for AB-type),<br>J61347-1 J61347-2-13 (except for B,AB and D-type)<br>,<br>; design refer to BS EN/EN60335-1(by request)<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024,<br>light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020|**HLG-40H-12**|**HLG-40H-12**|**HLG-40H-15**|**HLG-40H-15**|**HLG-40H-20**|**HLG-40H-20**|**HLG-40H-24**|**HLG-40H-24**|**HLG-40H-30**|**HLG-40H-30**|**HLG-40H-36**|**HLG-40H-36**|**HLG-40H-42**|**HLG-40H-42**|**HLG-40H-48**|**HLG-40H-48**|**HLG-40H-54**|**HLG-40H-54**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||||||| ||||12V||15V||20V||24V||30V||36V||42V||48V||54V|| |||**CONSTANT CURRENT REGIONNote.4**|7.2 ~12V||9 ~ 15V||12 ~ 20V||14.4 ~ 24V||18 ~ 30V||21.6 ~ 36V||25.2 ~ 42V||28.8 ~ 48V||32.4 ~ 54V|| |||**RATED CURRENT**|3.33A||2.67A||2A||1.67A||1.34A||1.12A||0.96A||0.84A||0.75A|| |||**RATED POWER**|39.96W||40.05W||40W||40.08W||40.2W||40.32W||40.32W||40.32W||40.5W|| |||**RIPPLE & NOISE (max.)Note.2**|150mVp-p||150mVp-p||150mVp-p||200mVp-p||200mVp-p||200mVp-p||200mVp-p||300mVp-p||300mVp-p|| |||**VOLTAGE ADJ. RANGE**|Adjustable for A/AB-Type only (via built-in potentiometer)<br>13.5 ~ 17V<br>17 ~ 22V<br>22 ~ 27V<br>27 ~ 33V<br>33 ~ 40V<br>44 ~ 53V<br>10.8 ~ 13.5V<br>49 ~ 58V<br>40 ~ 46V|||||||||||||||||| |||**CURRENT ADJ. RANGE**|Adjustable for A/AB-Type only (via built-in potentiometer)<br>2 ~ 3.33A<br>1.6 ~ 2.67A<br>1.2 ~ 2A<br>1 ~ 1.67A<br>0.8 ~ 1.34A<br>0.67 ~ 1.12A<br>0.5 ~ 0.84A<br>0.45 ~ 0.75A<br>0.58 ~ 0.96A|||||||||||||||||| |||**VOLTAGE TOLERANCENote.3**|±2.5%||±2.0%||±1.0%||±1.0%||±1.0%||±1.0%||±1.0%||±1.0%||±1.0%|| |||**LINE REGULATION**|±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%|| |||**LOAD REGULATION**|±2.0%||±1.5%||±1.0%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%|| |||**SETUP, RISE TIMENote.6**|500ms,80ms/115VAC 500ms,80ms/230VAC|||||||||||||||||| |||**HOLD UP TIME (Typ.)**|16ms / 115VAC, 230VAC|||||||||||||||||| |||**VOLTAGE RANGENote.5**|90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)|||||||||||||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||||||||||||||||| |||**POWER FACTOR (Typ.)**|PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load<br>(Please refer to "<br>" section)<br>POWER FACTOR (PF) CHARACTERISTIC|||||||||||||||||| |||**TOTAL HARMONIC DISTORTION**|THD< 20% (@ load<br>60% / 115VAC,230VAC; @ load<br>75% / 277VAC)<br>≧<br>≧<br>(Please refer to TOTAL HARMONIC DISTORTION (THD) section)<br>"<br>"|||||||||||||||||| |||**EFFICIENCY (Typ.)**|86.5%||86.5%||88%||88%||88.5%||88.5%||88.5%||89.5%||89.5%|| |||**AC CURRENT (Typ.)**|0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC|||||||||||||||||| |||**INRUSH CURRENT(Typ.)**|COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>μ|||||||||||||||||| |||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC|||||||||||||||||| |||**LEAKAGE CURRENT**|<0.75mA / 277VAC|||||||||||||||||| |||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed|||||||||||||||||| |||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed|||||||||||||||||| |||**OVER VOLTAGE**|Shut down o/p voltage, re-power on to recover<br>18 ~ 24V<br>15 ~ 21V<br>23 ~ 30V<br>28 ~ 35V<br>35 ~ 43V<br>41 ~ 49V<br>48 ~ 58V<br>59 ~ 68V<br>54 ~ 65V|||||||||||||||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|||||||||||||||||| |||**WORKING TEMP.**|Tcase=-40 ~ +80℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)|||||||||||||||||| |||**MAX. CASE TEMP.**|Tcase=+80℃|||||||||||||||||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||||||||||||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||||||||||||||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 60℃)|||||||||||||||||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||||||||||||||||| |||**SAFETY STANDARDSNote.8**|UL8750(type”HL”), CSA C22.2 No. 250.0-08 ,<br>independent ,<br>BS EN/EN/AS/NZS 61347-1,BS EN/EN/AS/NZS 61347-2-13<br>GB19510.1,GB19510.14,EAC TP TC 004,KC61347-1,KC61347-2-13<br>IP65 or IP67 approved ;<br>(except for AB-type),<br>J61347-1 J61347-2-13 (except for B,AB and D-type)<br>,<br>; design refer to BS EN/EN60335-1(by request)|||||||||||||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|||||||||||||||||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|||||||||||||||||| |||**EMC EMISSIONNote.8**|Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>≧60%) ; BS EN/EN61000-3-3,GB17743 and GB17625.1,<br>@ load<br>EAC TP TC 020|||||||||||||||||| |||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024,<br>light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020|||||||||||||||||| |||**MTBF**|3395.8K hrs min. Telcordia SR-332 (Bellcore) ; 345.8K hrs min. MIL-HDBK-217F (25℃)|||||||||||||||||| |||**DIMENSION**|171*61.5*36.8mm (L*W*H)|||||||||||||||||| |||**PACKING**|0.73Kg; 20pcs/15.6Kg/0.9CUFT|||||||||||||||||| |||℃ <br><br><br><br><br><br><br><br><br><br>℃<br><br>℃℃<br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>_File Name:HLG-40H-SPEC 2022-02-18_||||||||||||||||||| **HLG - 40H series** 40W Constant Voltage + Constant Current LED Driver ## **BLOCK DIAGRAM** **==> picture [471 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> Fosc : 100KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>(B Type)<br>O.T.P. O.L.P. DETECTION<br>FG<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. **==> picture [202 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>(A) Constant (B)<br>Voltage area Constant<br>Current area<br>60<br>(min.)<br>(C)<br>Hiccup<br>Protection<br>50 100 Io (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Typical output current normalized by rated current (%) _File Name:HLG-40H-SPEC 2022-02-18_ **HLG - 40H series** 40W Constant Voltage + Constant Current LED Driver ## **DIMMING OPERATION** **==> picture [499 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> +V(Red)<br>AC/L(Brown) -V(Black)<br>AC/N(Blue) HLG-40H<br>FG (Green/Yellow) DIM+(Purple)<br>DIM-(Pink)<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function (for B/AB-Type)** - ‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: - 1 ~ 10VDC, or 10V PWM signal or resistance. - ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. ‧Dimming source current from power supply: 100μA (typ.) ◎ Applying additive 1 ~ 10VDC **==> picture [157 x 469] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive resistance: **==> picture [214 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> _File Name:HLG-40H-SPEC 2022-02-18_ **HLG - 40H series** ## 40W Constant Voltage + Constant Current LED Driver Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options. **==> picture [401 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> N FG L<br>Relay Switch Adjuster<br>10K/N~100K/N Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Purple<br>Green/ DIM+ Pink<br>Yellow AC/L HLG-40H DIM- Black<br>Brown AC/N B-Type V(-)V(+) Red LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. _File Name:HLG-40H-SPEC 2022-02-18_ **HLG - 40H series** 40W Constant Voltage + Constant Current LED Driver ## **OUTPUT LOAD vs TEMPERATURE(Note.10)** **==> picture [511 x 643] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>230VAC 230VAC<br>Input only Input only<br>60 60<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 80 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTICS POWER FACTOR(PF) CHARACTERISTIC<br>※ Tcase at 70 ℃<br>Constant Current Mode<br>100 1<br>0 .9 9<br>90 0 .9 8<br>0 .9 7<br>80 0 .9 6<br>0 .9 5<br>70 0 .9 4<br>0 .9 3 2 7 7 V A C<br>60 0 .9 2 2 3 0 V A C<br>0 .9 1 1 1 5 V A C<br>50 0 .9<br>0 .8 9<br>40 0 .8 8<br>0 .8 7<br>0 .8 6<br>0 .8 5<br>90 100 125 135 145 155 165 175 180 200 230 305 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %<br>(40W)<br>INPUT VOLTAGE (V) 60Hz LOAD<br>※ De-rating is needed under low input voltage.<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>HLG-40H series possess superior working efficiency that up to 89.5%<br>※ 48V Model, Tcase at 70℃ can be reached in field applications.<br>25 ※ 48V Model, Tcase at 70℃<br>92<br>90<br>20<br>88<br>86<br>15 84<br>82<br>277VAC 277VAC<br>80<br>10 230VAC 230VAC<br>78<br>115VAC<br>115VAC 76<br>5 74<br>72<br>0 70<br>50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> _File Name:HLG-40H-SPEC 2022-02-18_ **HLG - 40H series** 40W Constant Voltage + Constant Current LED Driver ## **��������** **==> picture [332 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>25 30 35 40 45 50 55 60 65 70 75 80<br>Tcase ( )℃<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> _File Name:HLG-40H-SPEC 2022-02-18_ ## 40W Constant Voltage + Constant Current LED Driver ## **HLG - 40H series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.957B Unit:mm<br>※ Blank/D-Type<br>171<br>11.9 147.2<br>9.6<br>300±20 300±20<br>AC/L(Brown)AC/N(Blue)FG (Green/Yellow) SJOW 17AWG&H05RN-F 1.0mm *3C2 tc 73.6 SJOW 17AWG&05RN-F 1.0mm 2*2C +V(Red)-V(Black)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ A-Type<br>171<br>11.9 147.2<br>9.6<br>300±20 300±20<br>AC/L(Brown)AC/N(Blue) tc 73.6 +V(Red)<br>FG (Green/Yellow) SJOW 17AWG&H05RN-F 1.0mm *3C2 Io Vo SJOW 17AWG&05RN-F 1.0mm *2C2 -V(Black)<br>ADJ ADJ<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>**----- End of picture text -----**<br> _File Name:HLG-40H-SPEC 2022-02-18_ **HLG - 40H series** 40W Constant Voltage + Constant Current LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ B-Type<br>171<br>11.9 147.2<br>9.6 300±20<br>300±20 SJOW 17AWG&05RN-F 1.0mm *2C2 +V(Red)<br>AC/L(Brown) 73.6 -V(Black)<br>AC/N(Blue) tc UL2517 20AWG*2C<br>FG (Green/Yellow) SJOW 17AWG&H05RN-F 1.0mm *3C2 DIM+(Purple)<br>DIM-(Pink)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ AB-Type<br>171<br>11.9 147.2<br>9.6 300±20<br>300±20 SJOW 17AWG&05RN-F 1.0mm *2C2 +V(Red)<br>AC/L(Brown) 73.6 -V(Black)<br>AC/N(Blue) tc UL2517 20AWG*2C<br>FG (Green/Yellow) SJOW 17AWG&H05RN-F 1.0mm *3C2 ADJIo ADJVo DIM-(Pink)DIM+(Purple)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>5<br>32 46.5 1.6<br>30.75<br>36.8<br>**----- End of picture text -----**<br> _File Name:HLG-40H-SPEC 2022-02-18_ **HLG - 40H series** ## 40W Constant Voltage + Constant Current LED Driver ## **WATERPROOF CONNECTION** ※ Waterproof connector Waterproof connector can be assembled on the output cable of HLG-40H to operate in dry/wet/damp or outdoor environment. **==> picture [462 x 415] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>HLG-40H<br>source I/P O/P<br>Size Pin Configuration (Female) Size Pin Configuration (Female)<br>M12 M15<br>4-PIN 5-PIN 2-PIN<br>5A/PIN 5A/PIN 12A/PIN<br>Order No. M12-04 M12-05 Order No. M15-02<br>Suitable Current 10A max. 10A max. Suitable Current 12A max. LED Lamp<br>※ Cable Joiner<br>CJ04-1 suitable for 14AWG~16AWG<br>66<br>CJ04-2 suitable for 18AWG~22AWG<br>26 20<br>Up to four wires can be connected through this cable joiner by<br>soldering or clamping by tools.<br>LED Lamp<br>HLG-40H<br>O/P Wires<br>◎ CJ04 cable joiner can be purchased independently for user's own assembly.<br> MEAN WELL order No. : CJ04-1, CJ04-2.<br>25<br>ψ<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** **==> picture [177 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br> _File Name:HLG-40H-SPEC 2022-02-18_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →