Image not available
Illustrative purposes only
HLG-240H-54A
LED Driver, 240.3 W, 54 VDC, 4.45 A, Constant Current, Constant Voltage, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- Output Power Max:240.3W; Output Voltage Max:54V; Output Current:4.45A; LED Driver Mode:Constant Current, Constant Voltage; Input Voltage Min:90V; Input Voltage Max:305V; Product Range:H
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HLG-240H
- Output Current: 4.45A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 240.3W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 54VDC
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 61.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [374 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL BauarSicherheitbeegelodwacmat geprufto ges g<br>R-41027766 www.ID 2000000000tuv.com<br>(except for AB,C,D-type) [G (except for B/AB/D-type) &@® (except for C-type) 8 Whisi 4 ) HICBCES<br><br> IP65 IP67<br>JO V ®<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧Metal housing with class I design - ‧ - - - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧Ⅰ - ## ■ **** ## ■ **** current output. HLG-240H operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-240H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system. ■ **** ~~_—~~ ** ** ~~LIL~~ **** ||||| |---|---|---|---| |||I|| |||I|| |B|||| |||<br>I|| |C||<br>|| |D|||| _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Adjustable for A/AB/C-Type only (via built-in potentiometer)<br>1000ms,80ms/115VAC 500ms,80ms/230VAC<br>15ms / 115VAC, 230VAC<br>47 ~ 63Hz<br>4A / 115VAC 2A / 230VAC 1.2A / 277VAC<br><0.75mA / 277VAC<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>Compliance to BS EN/EN55015, BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class C (<br>) ;<br>@ load≧50%<br>BS EN/EN61000-3-3<br>,EAC TP TC 020;KC KN15,KN61547(<br>)<br>,GB17743 and GB17625.1<br>except for AB,C,D-type<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level(surge immunity<br>Line-Earth 4KV, Line-Line 2KV) EAC TP TC 020;KC KN15,KN61547(<br>)<br>except for AB,C,D-type<br>Tcase=-40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>2015.1K hrs min. Telcordia SR-332 (Bellcore) ;176.4K hrs min. MIL-HDBK-217F (25℃)<br>244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H C-Type)<br>1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B)1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240 C-Type)<br>Shut down and latch off o/p voltage, re-power on to recover<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>90%<br>90%<br>91.5%<br>92.5%<br>92.5%<br>92.5%<br>93%<br>92.5%<br>93.5%<br>±2.5%<br>8 ~ 16A<br>±2.0%<br>7.5 ~ 15A<br>±1.0%<br>6 ~ 12A<br>±1.0%<br>5 ~ 10A<br>±1.0%<br>4 ~ 8A<br>±1.0%<br>3.3 ~ 6.7A<br>±1.0%<br>2.5 ~ 5A<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>2.23 ~ 4.45A<br>±0.5%<br>±0.5%<br>±1.0%<br>2.86 ~ 5.72A<br>±0.5%<br>±0.5%<br>**HLG-240H-12**<br>**HLG-240H-15**<br>**HLG-240H-20**<br>**HLG-240H-24**<br>**HLG-240H-30**<br>**HLG-240H-36**<br>**HLG-240H-48**<br>12V<br>6 ~12V<br>15V<br>7.5 ~ 15V<br>20V<br>10 ~ 20V<br>24V<br>12 ~ 24V<br>30V<br>15 ~ 30V<br>36V<br>18 ~ 36V<br>48V<br>24 ~ 48V<br>16A<br>15A<br>12A<br>10A<br>8A<br>6.7A<br>5A<br>192W<br>225W<br>240W<br>240W<br>240W<br>241.2W<br>240W<br>150mVp-p<br>150mVp-p<br>14 ~ 16V<br>150mVp-p<br>18.6 ~ 21.4V<br>150mVp-p<br>22.4 ~ 25.6V<br>200mVp-p<br>28 ~ 32V<br>250mVp-p<br>33.5 ~ 38.5V<br>250mVp-p<br>44.8 ~ 51.2V<br>11.2 ~ 12.8V<br>**HLG-240H-54**<br>54V<br>27 ~ 54V<br>4.45A<br>240.3W<br>350mVp-p<br>50 ~ 57V<br>**HLG-240H-42**<br>42V<br>21 ~ 42V<br>5.72A<br>240.24W<br>250mVp-p<br>39 ~ 45V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>13.5 ~ 18V<br>17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V<br>33 ~ 39V<br>43 ~ 49V<br>55 ~ 63V<br>48 ~ 54V<br>60 ~ 67V<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**CONSTANT CURRENT REGIONNote.4**<br>UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(type”HL”), CSA C22.2 No. 250.0-08; BS EN/EN/AS/NZS 61347-1,<br>BS EN/EN/AS/NZS 61347-2-13 independent (except for HLG-240H C type); IEC/UL/BS EN/EN 62368-1(except for AB,D type),<br>UL8750;GB19510.1,GB19510.14<br>IP65 or IP67;J61347-1,J61347-2-13<br>,<br>(except for C-type);<br>(except for B,AB and D-type)<br>BIS IS15885( for 48V only), EAC TP TC 004,KC61347-1,KC61347-2-13<br>approved<br>(except for AB,C,D-type)<br>COLD START 75A(twidth=570 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC<br>Adjustable for A/AB/C-Type only (via built-in potentiometer)<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>PF≧0.98/115VAC, PF≧0.95/230VAC @ full load<br>(Please refer to "<br>" section)<br>POWER FACTOR (PF) CHARACTERISTIC<br>THD< 20% (@ load<br>50% / 115VAC,230VAC; @ load<br>75% / 277VAC)<br>≧<br>≧<br>(Please refer to TOTAL HARMONIC DISTORTION (THD) section)<br>"<br>"<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>℃ <br><br><br><br><br><br><br><br><br><br>℃<br><br><br><br><br><br>℃<br>℃<br><br><br>※Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>_File Name:HLG-240H-SPEC 2022-02-18_|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Adjustable for A/AB/C-Type only (via built-in potentiometer)<br>1000ms,80ms/115VAC 500ms,80ms/230VAC<br>15ms / 115VAC, 230VAC<br>47 ~ 63Hz<br>4A / 115VAC 2A / 230VAC 1.2A / 277VAC<br><0.75mA / 277VAC<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>Compliance to BS EN/EN55015, BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class C (<br>) ;<br>@ load≧50%<br>BS EN/EN61000-3-3<br>,EAC TP TC 020;KC KN15,KN61547(<br>)<br>,GB17743 and GB17625.1<br>except for AB,C,D-type<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level(surge immunity<br>Line-Earth 4KV, Line-Line 2KV) EAC TP TC 020;KC KN15,KN61547(<br>)<br>except for AB,C,D-type<br>Tcase=-40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>2015.1K hrs min. Telcordia SR-332 (Bellcore) ;176.4K hrs min. MIL-HDBK-217F (25℃)<br>244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H C-Type)<br>1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B)1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240 C-Type)<br>Shut down and latch off o/p voltage, re-power on to recover<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>90%<br>90%<br>91.5%<br>92.5%<br>92.5%<br>92.5%<br>93%<br>92.5%<br>93.5%<br>±2.5%<br>8 ~ 16A<br>±2.0%<br>7.5 ~ 15A<br>±1.0%<br>6 ~ 12A<br>±1.0%<br>5 ~ 10A<br>±1.0%<br>4 ~ 8A<br>±1.0%<br>3.3 ~ 6.7A<br>±1.0%<br>2.5 ~ 5A<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>2.23 ~ 4.45A<br>±0.5%<br>±0.5%<br>±1.0%<br>2.86 ~ 5.72A<br>±0.5%<br>±0.5%<br>**HLG-240H-12**<br>**HLG-240H-15**<br>**HLG-240H-20**<br>**HLG-240H-24**<br>**HLG-240H-30**<br>**HLG-240H-36**<br>**HLG-240H-48**<br>12V<br>6 ~12V<br>15V<br>7.5 ~ 15V<br>20V<br>10 ~ 20V<br>24V<br>12 ~ 24V<br>30V<br>15 ~ 30V<br>36V<br>18 ~ 36V<br>48V<br>24 ~ 48V<br>16A<br>15A<br>12A<br>10A<br>8A<br>6.7A<br>5A<br>192W<br>225W<br>240W<br>240W<br>240W<br>241.2W<br>240W<br>150mVp-p<br>150mVp-p<br>14 ~ 16V<br>150mVp-p<br>18.6 ~ 21.4V<br>150mVp-p<br>22.4 ~ 25.6V<br>200mVp-p<br>28 ~ 32V<br>250mVp-p<br>33.5 ~ 38.5V<br>250mVp-p<br>44.8 ~ 51.2V<br>11.2 ~ 12.8V<br>**HLG-240H-54**<br>54V<br>27 ~ 54V<br>4.45A<br>240.3W<br>350mVp-p<br>50 ~ 57V<br>**HLG-240H-42**<br>42V<br>21 ~ 42V<br>5.72A<br>240.24W<br>250mVp-p<br>39 ~ 45V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>13.5 ~ 18V<br>17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V<br>33 ~ 39V<br>43 ~ 49V<br>55 ~ 63V<br>48 ~ 54V<br>60 ~ 67V<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**CONSTANT CURRENT REGIONNote.4**<br>UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(type”HL”), CSA C22.2 No. 250.0-08; BS EN/EN/AS/NZS 61347-1,<br>BS EN/EN/AS/NZS 61347-2-13 independent (except for HLG-240H C type); IEC/UL/BS EN/EN 62368-1(except for AB,D type),<br>UL8750;GB19510.1,GB19510.14<br>IP65 or IP67;J61347-1,J61347-2-13<br>,<br>(except for C-type);<br>(except for B,AB and D-type)<br>BIS IS15885( for 48V only), EAC TP TC 004,KC61347-1,KC61347-2-13<br>approved<br>(except for AB,C,D-type)<br>COLD START 75A(twidth=570 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC<br>Adjustable for A/AB/C-Type only (via built-in potentiometer)<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>PF≧0.98/115VAC, PF≧0.95/230VAC @ full load<br>(Please refer to "<br>" section)<br>POWER FACTOR (PF) CHARACTERISTIC<br>THD< 20% (@ load<br>50% / 115VAC,230VAC; @ load<br>75% / 277VAC)<br>≧<br>≧<br>(Please refer to TOTAL HARMONIC DISTORTION (THD) section)<br>"<br>"<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>℃ <br><br><br><br><br><br><br><br><br><br>℃<br><br><br><br><br><br>℃<br>℃<br><br><br>※Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>_File Name:HLG-240H-SPEC 2022-02-18_|**HLG-240H-12**|**HLG-240H-12**|**HLG-240H-15**|**HLG-240H-15**|**HLG-240H-20**|**HLG-240H-20**|**HLG-240H-24**|**HLG-240H-24**|**HLG-240H-30**|**HLG-240H-30**|**HLG-240H-36**|**HLG-240H-36**|**HLG-240H-42**|**HLG-240H-42**|**HLG-240H-48**|**HLG-240H-48**|**HLG-240H-54**|**HLG-240H-54**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||||||| |||**DC VOLTAGE**|12V||15V||20V||24V||30V||36V||42V||48V||54V|| |||**CONSTANT CURRENT REGIONNote.4**|6 ~12V||7.5 ~ 15V||10 ~ 20V||12 ~ 24V||15 ~ 30V||18 ~ 36V||21 ~ 42V||24 ~ 48V||27 ~ 54V|| |||**RATED CURRENT**|16A||15A||12A||10A||8A||6.7A||5.72A||5A||4.45A|| |||**RATED POWER**|192W||225W||240W||240W||240W||241.2W||240.24W||240W||240.3W|| |||**RIPPLE & NOISE (max.)Note.2**|150mVp-p||150mVp-p||150mVp-p||150mVp-p||200mVp-p||250mVp-p||250mVp-p||250mVp-p||350mVp-p|| |||**VOLTAGE ADJ. RANGE**|14 ~ 16V<br>18.6 ~ 21.4V<br>22.4 ~ 25.6V<br>28 ~ 32V<br>33.5 ~ 38.5V<br>44.8 ~ 51.2V<br>11.2 ~ 12.8V<br>50 ~ 57V<br>39 ~ 45V<br>Adjustable for A/AB/C-Type only (via built-in potentiometer)|||||||||||||||||| |||**CURRENT ADJ. RANGE**|Adjustable for A/AB/C-Type only (via built-in potentiometer)<br>8 ~ 16A<br>7.5 ~ 15A<br>6 ~ 12A<br>5 ~ 10A<br>4 ~ 8A<br>3.3 ~ 6.7A<br>2.5 ~ 5A<br>2.23 ~ 4.45A<br>2.86 ~ 5.72A|||||||||||||||||| |||**VOLTAGE TOLERANCENote.3**|±2.5%||±2.0%||±1.0%||±1.0%||±1.0%||±1.0%||±1.0%||±1.0%||±1.0%|| |||**LINE REGULATION**|±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%|| |||**LOAD REGULATION**|±2.0%||±1.5%||±1.0%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%||±0.5%|| |||**SETUP, RISE TIMENote.6**|1000ms,80ms/115VAC 500ms,80ms/230VAC|||||||||||||||||| |||**HOLD UP TIME (Typ.)**|15ms / 115VAC, 230VAC|||||||||||||||||| |||**VOLTAGE RANGENote.5**|90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)|||||||||||||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||||||||||||||||| |||**POWER FACTOR (Typ.)**|PF≧0.98/115VAC, PF≧0.95/230VAC @ full load<br>(Please refer to "<br>" section)<br>POWER FACTOR (PF) CHARACTERISTIC|||||||||||||||||| |||**TOTAL HARMONIC DISTORTION**|THD< 20% (@ load<br>50% / 115VAC,230VAC; @ load<br>75% / 277VAC)<br>≧<br>≧<br>(Please refer to TOTAL HARMONIC DISTORTION (THD) section)<br>"<br>"|||||||||||||||||| |||**EFFICIENCY (Typ.)**|90%||90%||91.5%||92.5%||92.5%||92.5%||92.5%||93%||93.5%|| |||**AC CURRENT (Typ.)**|4A / 115VAC 2A / 230VAC 1.2A / 277VAC|||||||||||||||||| |||**INRUSH CURRENT (Typ.)**|COLD START 75A(twidth=570 s measured at 50% Ipeak) at 230VAC;<br> Per NEMA 410<br>μ|||||||||||||||||| |||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC|||||||||||||||||| |||**LEAKAGE CURRENT**|<0.75mA / 277VAC|||||||||||||||||| |||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed|||||||||||||||||| |||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed|||||||||||||||||| |||**OVER VOLTAGE**|Shut down and latch off o/p voltage, re-power on to recover<br>13.5 ~ 18V<br>17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V<br>33 ~ 39V<br>43 ~ 49V<br>55 ~ 63V<br>48 ~ 54V<br>60 ~ 67V|||||||||||||||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||||||||||||||| |||**WORKING TEMP.**|Tcase=-40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)|||||||||||||||||| |||**MAX. CASE TEMP.**|Tcase=+90℃|||||||||||||||||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||||||||||||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||||||||||||||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||||||||||||||||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||||||||||||||||| |||**SAFETY STANDARDS**|UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(type”HL”), CSA C22.2 No. 250.0-08; BS EN/EN/AS/NZS 61347-1,<br>BS EN/EN/AS/NZS 61347-2-13 independent (except for HLG-240H C type); IEC/UL/BS EN/EN 62368-1(except for AB,D type),<br>UL8750;GB19510.1,GB19510.14<br>IP65 or IP67;J61347-1,J61347-2-13<br>,<br>(except for C-type);<br>(except for B,AB and D-type)<br>BIS IS15885( for 48V only), EAC TP TC 004,KC61347-1,KC61347-2-13<br>approved<br>(except for AB,C,D-type)|||||||||||||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|||||||||||||||||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|||||||||||||||||| |||**EMC EMISSION**|Compliance to BS EN/EN55015, BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class C (<br>) ;<br>@ load≧50%<br>BS EN/EN61000-3-3<br>,EAC TP TC 020;KC KN15,KN61547(<br>)<br>,GB17743 and GB17625.1<br>except for AB,C,D-type|||||||||||||||||| |||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level(surge immunity<br>Line-Earth 4KV, Line-Line 2KV) EAC TP TC 020;KC KN15,KN61547(<br>)<br>except for AB,C,D-type|||||||||||||||||| |||**MTBF**|2015.1K hrs min. Telcordia SR-332 (Bellcore) ;176.4K hrs min. MIL-HDBK-217F (25℃)|||||||||||||||||| |||**DIMENSION**|244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H C-Type)|||||||||||||||||| |||**PACKING**|1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B)1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240 C-Type)|||||||||||||||||| |||℃ <br><br><br><br><br><br><br><br><br><br>℃<br><br><br><br><br><br>℃<br>℃<br><br><br>※Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>_File Name:HLG-240H-SPEC 2022-02-18_||||||||||||||||||| **HLG - 240H series** ## 240W Constant Voltage + Constant Current LED Driver ## **BLOCK DIAGRAM** **==> picture [471 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> Fosc : 100KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>(B Type)<br>DETECTION<br>FG O.L.P.<br>PWM & PFC CIRCUIT<br>PFC CONTROL<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** - ※ This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. **==> picture [202 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>(A) Constant (B)<br>Voltage area Constant<br>Current area<br>50<br>(min.)<br>(C)<br>Hiccup<br>Protection<br>50 100 Io (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Typical output current normalized by rated current (%) _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver ## **DIMMING OPERATION** **==> picture [461 x 604] intentionally omitted <==** **----- Start of picture text -----**<br> -V(Black)<br>FG (Green/Yellow) +V(Red)<br>AC/L(Brown) HLG-240H<br>DIM+(Purple)<br>AC/N(Blue)<br>DIM-(Pink)<br>※ 3 in 1 dimming function (for B/AB-Type)<br>‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:<br> 1 ~ 10VDC, or 10V PWM signal or resistance.<br>‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>‧Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 1 ~ 10VDC<br>100%<br>90%<br>+<br>+V + 80%<br>70%<br>-<br>-V - 60%<br>DIM+ 50%<br>+<br>Additive Voltage 40%<br>- 30%<br>DIM-<br>20%<br>“DO NOT connect "DIM- to -V" 10%<br>1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):<br>100%<br>90%<br>+<br>+V + 80%<br>70%<br>-<br>-V - 60%<br>DIM+ 50%<br>Additive PWM signal 40%<br>30%<br>DIM-<br>20%<br>“DO NOT connect "DIM- to -V" 10%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>◎ Applying additive resistance:<br>100%<br>+V + + 90%<br>80%<br>-<br>-V - 70%<br>DIM+ 60%<br>50%<br>Additive Resistance<br>40%<br>DIM- 30%<br>“DO NOT connect "DIM- to -V" 20%<br>10%<br>10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:HLG-240H-SPEC 2022-02-18_ > 240W Constant Voltage + Constant Current LED Driver **HLG - 240H series** Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options. **==> picture [401 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> N FG L<br>Relay Switch Adjuster<br>10K/N~100K/N Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Green/ DIM+<br>Yellow AC/L HLG-240H DIM-<br>Brown B-Type V(-)<br>AC/N V(+) LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver ## **OUTPUT LOAD vs TEMPERATURE(Note. 10)** **==> picture [508 x 385] intentionally omitted <==** **----- Start of picture text -----**<br> 230VAC<br>100 100<br>80 80<br>60 100VAC 60<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 90 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTICS POWER FACTOR(PF) CHARACTERISTIC<br>※ Tcase at 80 ℃<br>100<br>Constant Current Mode<br>90<br>1.00<br>80 0.98<br>0.96<br>70 0.94<br>0.92<br>60 0.90 277Vac<br>50 0.88 230Vac<br>0.86 115Vac<br>40 0.84<br>0.82<br>0.80<br>90 100 125 135 145 155 165 175 180 200 230 305<br>0.78<br>INPUT VOLTAGE (V) 60Hz 50% 60% 70% 80% 90% 100%<br>(240W)<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> - ※ De-rating is needed under low input voltage. ## **TOTAL HARMONIC DISTORTION (THD)** - ※ 48V Model, Tcase at 80℃ **==> picture [233 x 164] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>12<br>10<br>277VAC<br>8 230VAC<br>6 115VAC<br>4<br>2<br>0<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>THD(%)<br>**----- End of picture text -----**<br> ## **EFFICIENCY vs LOAD** HLG-240H series possess superior working efficiency that up to 93.5% can be reached in field applications. ※ 48V Model, Tcase at 80℃ **==> picture [246 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> 96<br>92<br>88<br>277Vac<br>84<br>230Vac<br>80 115Vac<br>76<br>72<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver ## **LIFE TIME** **==> picture [306 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80 90<br>Tcase ( ℃)<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver **==> picture [515 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION<br>Case No.994C Unit:mm<br>※ Blank/D-Type<br>244.2<br>12 220.2<br>9.6<br>300±20 300±20<br>FG (Green/Yellow) T case 110.1 -V(Black)<br>AC/L(Brown)AC/N(Blue) SJOW 17AWG&H05RN-F 1.0mm2*3C tc SJOW 17AWG&05RN-F 1.0mm2*2C +V(Red)<br>(SJOW 14AWG*2C for 12V~20V)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ A-Type<br>244.2<br>12 220.2<br>9.6<br>300±20 300±20<br>FG AC/L(Brown)AC/N(Blue) (Green/Yellow) SJOW 17AWG&H05RN-F 1.0mm2*3C T casetc 110.1Vo Io SJOW 17AWG&05RN-F 1.0mm2*2C +V(Red)-V(Black)<br>ADJ. ADJ. (SJOW 14AWG*2C for 12V~20V)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ B-Type<br>244.2<br>12 220.2<br>300±20<br>9.6<br>SJOW 17AWG&05RN-F 1.0mm2*2C<br>FG (Green/Yellow) 300±20 T case 110.1 (SJOW 14AWG*2C for 12V~20V) +V(Red)-V(Black)<br>AC/L(Brown) tc<br>AC/N(Blue) SJOW 17AWG&H05RN-F 1.0mm2*3C DIM+(Purple)<br>DIM-(Pink)<br>UL2517 20AWG*2C<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>**----- End of picture text -----**<br> _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** 240W Constant Voltage + Constant Current LED Driver **==> picture [514 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>244.2<br>12 220.2<br>300±20<br>9.6<br>SJOW 17AWG&05RN-F 1.0mm2*2C<br>FG (Green/Yellow) 300±20 T case 110.1 (SJOW 14AWG*2C for 12V~20V) +V(Red)-V(Black)<br>AC/L(Brown) tc<br>AC/N(Blue) SJOW 17AWG&H05RN-F 1.0mm2*3C Vo Io DIM+(Purple)DIM-(Pink)<br>ADJ. ADJ. UL2517 20AWG*2C<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ C-Type<br>251<br>15.4 220.2<br>8<br>1<br>T case 110.1 1<br>I/P 2 tc 2 O/P<br>3<br>Vo Io<br>ADJ. ADJ.<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>AC Input Terminal Pin No. Assignment DC Output Terminal Pin No. Assignment<br>Pin No. Assignment Pin No. Assignment<br>1 FG 1 -V<br>2 AC/L 2 +V<br>3 AC/N<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>8<br>9.5<br>37 68<br>7.5<br>34<br>8<br>38.8<br>**----- End of picture text -----**<br> _File Name:HLG-240H-SPEC 2022-02-18_ **HLG - 240H series** ## 240W Constant Voltage + Constant Current LED Driver ## **WATERPROOF CONNECTION** ※ Waterproof connector Waterproof connector can be assembled on the output cable of HLG-240H to operate in dry/wet/damp or outdoor environment. **==> picture [484 x 602] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>HLG-240H<br>source I/P O/P<br>Size Pin Configuration (Female) Size Pin Configuration (Female)<br>M12 M15<br>4-PIN 5-PIN 2-PIN<br>5A/PIN 5A/PIN 12A/PIN<br>Order No. M12-04 M12-05 Order No. M15-02<br>Suitable Current 10A max. 10A max. Suitable Current 12A max. LED Lamp<br>※ Cable Joiner<br>CJ04-1 suitable for 14AWG~16AWG<br>66<br>CJ04-2 suitable for 18AWG~22AWG<br>26 20<br>Up to four wires can be connected through this cable joiner by<br>soldering or clamping by tools.<br>LED Lamp<br>HLG-240H<br>O/P Wires<br>◎ CJ04 cable joiner can be purchased independently for user's own assembly.<br> MEAN WELL order No. : CJ04-1, CJ04-2.<br>※ Junction Box Option<br>220.2 76 10<br>382.2 5<br>FG (Green/Yellow)<br>AC/L(Brown) -V<br>AC/N(Blue) +V<br>2-ψ5<br>3- PF 1/2" 3- PF 1/2"<br>150±20 150±20<br>86<br>◎ Junction box option is available for A / Blank - Type. Please contact MEAW WELL for details.<br>25<br>ψ<br>6<br>8.5<br>68 61 32<br>8.5<br>35 38.8<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:HLG-240H-SPEC 2022-02-18_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →