Image not available
Illustrative purposes only
HLG-185H-C700AB
LED Driver, LED Lighting, 200.2 W, 286 VDC, 700 mA, Constant Current, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HLG-185H-C
- Output Current: 700mA
- LED Driver Mode: Constant Current
- Output Power Max: 200.2W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 286VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 52.67 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HLG - 185H - C series** 200W Constant Current Mode LED Driver > ** IP65 IP67** ## ■ **** - ‧ - ‧Ⅰ - ‧ - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - - ‧ - ‧ ## ■ **** ~ ℃℃ ■ ** ** ~~—Uu~~ **** ||||| |---|---|---|---| |A||I|| ||||| |||<br>I|| ||||| _File Name:HLG-185H-C-SPEC 2019-10-15_ ## 200W Constant Current Mode LED Driver ## **HLG - 185H - C series** ## **SPECIFICATION** |**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME**<br>**Note.4**<br>**VOLTAGE RANGE**<br>**Note.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Can be adjusted by internalpotentiometer (A/AB type only)<br>1000ms/115VAC 500ms/230VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>Compliance toEN55015, EN61000-3-2 Class C (<br>50% load) ; EN61000-3-3,<br>≧<br>,EAC TP TC 020<br>GB17743 and GB17625.1<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (<br>)<br>surge immunity Line-Earth 4KV, Line-Line 2KV ,EAC TP TC 020<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes;<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>Constant current limiting, recovers automatically after fault condition is removed<br>94%<br>94%<br>94%<br>94%<br>**HLG-185H-C500**<br>**HLG-185H-C700**<br>**HLG-185H-C1050**<br>**HLG-185H-C1400**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>COLD START 55A(t<br>=900 s measured at 50% I<br>) at 230VAC;<br>width<br>peak<br>Per NEMA 410<br>**TOTAL HARMONIC DISTORTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**CONSTANT CURRENT REGION Note.2**<br>**PACKING**<br>**NOTE**<br>μ<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC<br>**CURRENT TOLERANCE**<br>±5%<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>PF<br>0.9 /<br>VAC or PF<br>0.96/2<br>VAC<br>full load<br>≧<br>≧<br>≧<br>8 115<br>30<br>or PF<br>0.93/277VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>THD< 20%@<br>50% load/115VAC, or 230VAC, or @<br>75% load/277VAC<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>**WORKING TEMP.**<br>Tcase=-40 ~ +90<br>(Refer to "Derating Curve")<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>500mA<br>700mA<br>1050mA<br>1400mA<br>200W<br>200.2W<br>199.5W<br>200.2W<br>200V ~ 400V<br>143V ~ 286V<br>95V ~ 190V<br>71V ~ 143V<br>250 ~ 500mA<br>350 ~ 700mA<br>525 ~ 1050mA<br>700 ~ 1400mA<br>2A / 115VAC 1A / 230VAC 0.85A / 277VAC<br>450 ~ 470V<br>320 ~ 340V<br>210 ~ 225V<br>160 ~ 170V<br>10 ~ 95% RH non-condensing<br>UL8750, CSA C22.2 No. 250.13-12, EN/AS/NZS 61347-1, EN/AS/NZS 61347-2-13, EN62384 independent,<br>;<br>GB19510.1,GB19510.14<br>, J61347-1, J61347-2-13<br>approved<br>IP65 or IP67<br>(for A type only), EAC TP TC 004<br>651.1K hrs min.<br>Telcordia SR-332 (Bellcore) ; 191.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>228*68*38.8mm (L*W*H)<br>1.15Kg; 12pcs/14.8Kg/0.8CUFT<br>℃<br>℃<br>℃<br>℃<br>De~~GO~~<br>~~GO~~<br>a<br>Qe<br>~~J~~<br>aRe<br>~~Ge~~<br>eeGO<br>~~Oe~~<br>ee<br>~~en~~<br>~~a ener~~<br>De<br>~~ee~~<br>ee<br>~~ee~~<br>ee<br>~~Ge~~<br>ee<br>De<br>es<br>ee<br>ee<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 —_of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently<br>connected to the mains.<br>7. This series meets the typical lifeexpectancy of>62,000 hours ofoperationwhen Tcase, particularly(©)point (orTMP, per DLC), is about 75<br>or less.<br>8. Please refer to the warranty statement on MEAN WELL's website at http:/Awww.meanwell.com.<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/Awww.meanwell.com/Upload/PDF/LED_EN.pdf|**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME**<br>**Note.4**<br>**VOLTAGE RANGE**<br>**Note.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Can be adjusted by internalpotentiometer (A/AB type only)<br>1000ms/115VAC 500ms/230VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>Compliance toEN55015, EN61000-3-2 Class C (<br>50% load) ; EN61000-3-3,<br>≧<br>,EAC TP TC 020<br>GB17743 and GB17625.1<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (<br>)<br>surge immunity Line-Earth 4KV, Line-Line 2KV ,EAC TP TC 020<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes;<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>Constant current limiting, recovers automatically after fault condition is removed<br>94%<br>94%<br>94%<br>94%<br>**HLG-185H-C500**<br>**HLG-185H-C700**<br>**HLG-185H-C1050**<br>**HLG-185H-C1400**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>COLD START 55A(t<br>=900 s measured at 50% I<br>) at 230VAC;<br>width<br>peak<br>Per NEMA 410<br>**TOTAL HARMONIC DISTORTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**CONSTANT CURRENT REGION Note.2**<br>**PACKING**<br>**NOTE**<br>μ<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC<br>**CURRENT TOLERANCE**<br>±5%<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>PF<br>0.9 /<br>VAC or PF<br>0.96/2<br>VAC<br>full load<br>≧<br>≧<br>≧<br>8 115<br>30<br>or PF<br>0.93/277VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>THD< 20%@<br>50% load/115VAC, or 230VAC, or @<br>75% load/277VAC<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>**WORKING TEMP.**<br>Tcase=-40 ~ +90<br>(Refer to "Derating Curve")<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>500mA<br>700mA<br>1050mA<br>1400mA<br>200W<br>200.2W<br>199.5W<br>200.2W<br>200V ~ 400V<br>143V ~ 286V<br>95V ~ 190V<br>71V ~ 143V<br>250 ~ 500mA<br>350 ~ 700mA<br>525 ~ 1050mA<br>700 ~ 1400mA<br>2A / 115VAC 1A / 230VAC 0.85A / 277VAC<br>450 ~ 470V<br>320 ~ 340V<br>210 ~ 225V<br>160 ~ 170V<br>10 ~ 95% RH non-condensing<br>UL8750, CSA C22.2 No. 250.13-12, EN/AS/NZS 61347-1, EN/AS/NZS 61347-2-13, EN62384 independent,<br>;<br>GB19510.1,GB19510.14<br>, J61347-1, J61347-2-13<br>approved<br>IP65 or IP67<br>(for A type only), EAC TP TC 004<br>651.1K hrs min.<br>Telcordia SR-332 (Bellcore) ; 191.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>228*68*38.8mm (L*W*H)<br>1.15Kg; 12pcs/14.8Kg/0.8CUFT<br>℃<br>℃<br>℃<br>℃<br>De~~GO~~<br>~~GO~~<br>a<br>Qe<br>~~J~~<br>aRe<br>~~Ge~~<br>eeGO<br>~~Oe~~<br>ee<br>~~en~~<br>~~a ener~~<br>De<br>~~ee~~<br>ee<br>~~ee~~<br>ee<br>~~Ge~~<br>ee<br>De<br>es<br>ee<br>ee<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 —_of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently<br>connected to the mains.<br>7. This series meets the typical lifeexpectancy of>62,000 hours ofoperationwhen Tcase, particularly(©)point (orTMP, per DLC), is about 75<br>or less.<br>8. Please refer to the warranty statement on MEAN WELL's website at http:/Awww.meanwell.com.<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/Awww.meanwell.com/Upload/PDF/LED_EN.pdf|**HLG-185H-C500**<br>~~GO~~|**HLG-185H-C700**<br>~~GO~~|**HLG-185H-C1050**<br>~~GO~~|**HLG-185H-C1400**<br>~~GO~~| |---|---|---|---|---|---| ||**RATED CURRENT**<br>De|500mA<br>~~GO~~|700mA<br>~~GO~~|1050mA<br>~~GO~~|1400mA<br>~~GO~~| ||**RATED POWER**<br>De<br>~~GO~~<br>a|200W<br>~~GO~~<br>~~GO~~<br>Qe|200.2W<br>~~GO~~<br>~~GO~~|199.5W<br>~~GO~~<br>~~GO~~|200.2W<br>~~GO~~<br>~~GO~~| ||**CONSTANT CURRENT REGION Note.2**<br>~~GO~~<br>a|200V ~ 400V<br>~~GO~~<br>Qe|143V ~ 286V<br>~~GO~~|95V ~ 190V<br>~~GO~~|71V ~ 143V<br>~~GO~~| ||**CURRENT ADJ. RANGE**<br>a<br>~~J~~<br>a|Can be adjusted by internalpotentiometer (A/AB type only)<br>250 ~ 500mA<br>350 ~ 700mA<br>525 ~ 1050mA<br>700 ~ 1400mA<br>Qe<br>~~J~~|||| ||**CURRENT RIPPLE**<br>~~J~~<br>aRe|5.0% max. @rated current<br>~~J~~|||| ||**CURRENT TOLERANCE**<br>aRe|±5%|||| ||**SET UP TIME**<br>**Note.4**<br>Re|1000ms/115VAC 500ms/230VAC|||| ||**VOLTAGE RANGE**<br>**Note.3**|90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)|||| ||**FREQUENCY RANGE**<br>~~Ge~~|47 ~ 63Hz<br>~~Ge~~|||| ||**POWER FACTOR (Typ.)**<br>~~Ge~~|PF<br>0.9 /<br>VAC or PF<br>0.96/2<br>VAC<br>full load<br>≧<br>≧<br>≧<br>8 115<br>30<br>or PF<br>0.93/277VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>~~Ge~~|||| ||**TOTAL HARMONIC DISTORTION**<br>ee|THD< 20%@<br>50% load/115VAC, or 230VAC, or @<br>75% load/277VAC<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>GO|||| ||**EFFICIENCY (Typ.)**<br>ee|94%<br>GO|94%<br>GO|94%<br>GO|94%<br>GO| ||**AC CURRENT (Typ.)**<br>ee<br>~~Oe~~<br>ee|2A / 115VAC 1A / 230VAC 0.85A / 277VAC<br>GO<br>~~Oe~~|||| ||**INRUSH CURRENT(Typ.)**<br>ee|COLD START 55A(t<br>=900 s measured at 50% I<br>) at 230VAC;<br>width<br>peak<br>Per NEMA 410<br>μ|||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>ee|2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC|||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC|||| ||**SHORT CIRCUIT**<br>~~en~~|Constant current limiting, recovers automatically after fault condition is removed<br>~~en~~|||| ||**OVER VOLTAGE**<br>~~en~~<br>~~a ener~~<br>De|Shut down o/p voltage with auto-recovery or re-power on to recovery<br>450 ~ 470V<br>320 ~ 340V<br>210 ~ 225V<br>160 ~ 170V<br>~~en~~<br>~~ener~~|||| ||**OVER TEMPERATURE**<br>~~a ener~~<br>De|Shut down o/p voltage, recovers automatically after temperature goes down<br>~~ener~~|||| ||**WORKING TEMP.**<br>De|Tcase=-40 ~ +90<br>(Refer to "Derating Curve")<br>℃|||| ||**MAX. CASE TEMP.**<br>~~ee~~<br>ee|Tcase=+90℃<br>~~ee~~|||| ||**WORKING HUMIDITY**<br>~~ee~~<br>ee<br>~~ee~~|10 ~ 95% RH non-condensing<br>~~ee~~<br>~~ee~~|||| ||**STORAGE TEMP., HUMIDITY**<br>ee<br>~~ee~~<br>ee|-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>~~ee~~|||| ||**TEMP. COEFFICIENT**<br>ee|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||| ||**VIBRATION**<br>ee|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes;|||| ||**SAFETY STANDARDS**<br>~~Ge~~|UL8750, CSA C22.2 No. 250.13-12, EN/AS/NZS 61347-1, EN/AS/NZS 61347-2-13, EN62384 independent,<br>;<br>GB19510.1,GB19510.14<br>, J61347-1, J61347-2-13<br>approved<br>IP65 or IP67<br>(for A type only), EAC TP TC 004<br>~~Ge~~|||| ||**WITHSTAND VOLTAGE**<br>~~Ge~~<br>ee|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>~~Ge~~|||| ||**ISOLATION RESISTANCE**<br>ee<br>De|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| ||**EMC EMISSION**<br>ee<br>De<br>es|Compliance toEN55015, EN61000-3-2 Class C (<br>50% load) ; EN61000-3-3,<br>≧<br>,EAC TP TC 020<br>GB17743 and GB17625.1|||| ||**EMC IMMUNITY**<br>De<br>es<br>ee|Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (<br>)<br>surge immunity Line-Earth 4KV, Line-Line 2KV ,EAC TP TC 020|||| ||**MTBF**<br>es<br>ee<br>ee|651.1K hrs min.<br>Telcordia SR-332 (Bellcore) ; 191.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**<br>ee<br>ee|228*68*38.8mm (L*W*H)|||| ||**PACKING**<br>ee<br>a|1.15Kg; 12pcs/14.8Kg/0.8CUFT|||| ||℃<br>℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 —_of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently<br>connected to the mains.<br>7. This series meets the typical lifeexpectancy of>62,000 hours ofoperationwhen Tcase, particularly(©)point (orTMP, per DLC), is about 75<br>or less.<br>8. Please refer to the warranty statement on MEAN WELL's website at http:/Awww.meanwell.com.<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/Awww.meanwell.com/Upload/PDF/LED_EN.pdf||||| _File Name:HLG-185H-C-SPEC 2019-10-15_ ## 200W Constant Current Mode LED Driver ## **HLG - 185H - C series** ## **BLOCK DIAGRAM** **==> picture [471 x 440] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 70KHz<br>PWM fosc : 60KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>(B Type)<br>O.T.P. O.L.P. DETECTION<br>FG<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>DRIVING METHODS OF LED MODULE<br>※ This series works in constant current mode to directly drive the LEDs.<br>In the constant current region, the highest voltage at the output of the driver<br>100<br>depends on the configuration of the end systems.<br>Should there be any compatibility issues, please contact MEAN WELL.<br>Constant<br>Current area<br>50<br>50 100 Io (%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** _File Name:HLG-185H-C-SPEC 2019-10-15_ **HLG - 185H - C series** 200W Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [462 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> DIM+(Gray)<br>FG AC/L(Brown)(Green/Yellow) HLG-185H-C DIM-(Black)<br>AC/N(Blue) -V(Blue)<br>+V(Brown)<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function (for B/AB-Type)** - ‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: - 1 ~ 10VDC, or 10V PWM signal or resistance. **==> picture [295 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>‧Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 1 ~ 10VDC<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>Output current (%)<br>**----- End of picture text -----**<br> **==> picture [157 x 469] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> - Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): **==> picture [215 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive resistance: **==> picture [214 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> _File Name:HLG-185H-C-SPEC 2019-10-15_ **HLG - 185H - C series** ## 200W Constant Current Mode LED Driver Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options. **==> picture [401 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> N FG L<br>Relay Switch Adjuster<br>10K/N~100K/N Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Gray<br>Green/ DIM+ Black<br>Yellow AC/L HLG-185H-C DIM-<br>Brown AC/N B-Type V(-)V(+) BlueBrown LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. _File Name:HLG-185H-C-SPEC 2019-10-15_ **HLG - 185H - C series** 200W Constant Current Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE(Note.8)** **==> picture [490 x 585] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>C1400 C1400<br>80 80<br>Others Others<br>60 60<br>40 40<br>20 20<br>-40 -20 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -20 0 20 45 55 65 75 90(HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 80℃<br>100 1<br>90 0 .9 8<br>80 0 .9 6<br>70 0 .9 4 2 7 7 V<br>0 .9 2 2 3 0 V<br>60<br>1 1 5 V<br>0 .9<br>50<br>0 .8 8<br>40<br>0 .8 6<br>5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %<br>90 100 125 135 145 155 165 175 180 200 230 305 (200W)(250W)<br>LOAD<br>INPUT VOLTAGE (V) 60Hz<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>HLG-185H-C series possess superior working efficiency that up to 94% can<br>※ 700mA Model, Tcase at 80℃ be reached in field applications.<br>25 ※ 700mA Model, Tcase at 80℃ 700mA Model, Tcase at 80℃℃<br>20 95<br>93<br>91<br>15<br>89<br>277VAC<br>87 277V<br>10 230VAC<br>85 230V<br>115VAC 83 115V<br>5<br>81<br>79<br>0 77<br>50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> HLG-185H-C series possess superior working efficiency that up to 94% can be reached in field applications. ※ 700mA Model, Tcase at 80℃ 700mA Model, Tcase at 80℃℃ _File Name:HLG-185H-C-SPEC 2019-10-15_ **HLG - 185H - C series** 200W Constant Current Mode LED Driver ## **LIFE TIME** **==> picture [388 x 239] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80 90<br>Tcase�(����)℃<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:HLG-185H-C-SPEC 2019-10-15_ ## 200W Constant Current Mode LED Driver ## **HLG - 185H - C series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.994D Unit:mm<br>※ A-Type<br>228<br>12 204<br>9.6<br>Io<br>300±20 ADJ.<br>AC/L(Brown)FG (Green/Yellow) tc 102 300±20<br>AC/N(Blue) SJOW 17AWG&H05RN-F 1.0mm²x3C -V(Blue)<br> SOOW 17AWG&H07RN-F 1.0mm²x2C +V(Brown)<br> (for HLG-185H-C500)<br> SJOW 17AWG&H05RN-F 1.0mm²x2C(for others)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ B-Type 228<br>12 204<br>300±20<br>9.6<br>SJOW 17AWG&H05RN-F 1.0mm²x2C<br>300±20<br>FG (Green/Yellow) 102 DIM-(Black)DIM+(Gray)<br>AC/L(Brown) tc<br>AC/N(Blue) SJOW 17AWG&H05RN-F 1.0mm²x3C -V(Blue)<br> SOOW 17AWG&H07RN-F 1.0mm²x2C +V(Brown)<br> SJOW 17AWG&H05RN-F 1.0mm (for HLG-185H-C500) ²x2C(for others)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>**----- End of picture text -----**<br> _File Name:HLG-185H-C-SPEC 2019-10-15_ **HLG - 185H - C series** 200W Constant Current Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>228<br>12 204<br>300±20<br>9.6<br>300±20 ADJ.Io SJOW 17AWG&H05RN-F 1.0mm²x2C<br>FG (Green/Yellow) 102 DIM-(Black)DIM+(Gray)<br>AC/L(Brown) tc<br>AC/N(Blue) SJOW 17AWG&H05RN-F 1.0mm²x3C -V(Blue)<br> SOOW 17AWG&H07RN-F 1.0mm²x2C +V(Brown)<br> SJOW 17AWG&H05RN-F 1.0mm (for HLG-185H-C500) ²x2C(for others)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ D-Type<br>228<br>12 204<br>9.6<br>300±20<br>FG AC/L(Brown)(Green/Yellow) T casetc 102 300±20<br>AC/N(Blue) SJOW 17AWGx3C -V(Blue)<br> SOOW 17AWG&H07RN-F 1.0mm²x2C +V(Brown)<br> SJOW 17AWG&H05RN-F 1.0mm (for HLG-185H-C500) ²x2C(for others)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>**----- End of picture text -----**<br> _File Name:HLG-185H-C-SPEC 2019-10-15_ **HLG - 185H - C series** ## 200W Constant Current Mode LED Driver ## **WATERPROOF CONNECTION** ◎ Waterproof connector Waterproof connector can be assembled on the output cable of HLG-185H-C to operate in dry/wet/damp or outdoor environment. **==> picture [462 x 415] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>HLG-185H-C<br>source I/P O/P<br>Size Pin Configuration (Female) Size Pin Configuration (Female)<br>M12 M15<br>4-PIN 5-PIN 2-PIN<br>5A/PIN 5A/PIN 12A/PIN<br>Order No. M12-04 M12-05 Order No. M15-02<br>Suitable Current 10A max. 10A max. Suitable Current 12A max. LED Lamp<br>◎ Cable Joiner<br>CJ04-1 suitable for 14AWG~16AWG<br>66<br>CJ04-2 suitable for 18AWG~22AWG<br>26 20<br>Up to four wires can be connected through this cable joiner by<br>soldering or clamping by tools.<br>LED Lamp<br>HLG-185H-C<br>O/P Wires<br>※CJ04 cable joiner can be purchased independently for user's own assembly.<br> MEAN WELL order No. : CJ04-1, CJ04-2.<br>25<br>ψ<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** **==> picture [177 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br> _File Name:HLG-185H-C-SPEC 2019-10-15_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →