HFKP/012-1H4T
Automotive Relay, 12 VDC, 100 A, SPST, Through Hole, PC Pin, HFKP Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: HONGFA
- Product type: Automotive Relays
- SVHC: No SVHC (04-Feb-2026)
- Coil Voltage: 12VDC
- Product Range: HFKP Series
- Relay Mounting: Through Hole
- Coil Resistance: 90ohm
- Contact Current: 100A
- Relay Terminals: PC Pin
- Contact Material: Silver Tin Oxide
- Contact Configuration: SPST
- Contact Voltage DC Nom: 75V
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 1.56 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **HFKP** ## **AUTOMOTIVE RELAY** ## **Features** - 45A switching capability - PCB terminals ## **Typical Applications** Central door lock, Anti-theft lock, Power doors & windows, Turning lamp, dangerous signal & scram lamp control, Seat adjustment, Air-conditioning, Fuel pump control, Low temperature control, Sunroof motor control, - 1 Form A & 1 Form C contact arrangement - RoHS & ELV compliant Audio system, Rear window defoggers, Starter solenoid switches ## **CHARACTERISTICS** |Contact arrangement|1A, 1C| |---|---| |Voltage drop (initial) 1)|NO:Typ.20mV,250mV max.(at 10A)<br>NC:Typ.30mV,250mV max.(at 10A)| |Max. continuous current 2) 9)|30A (at 85<br>, 8h)| |Max. switching current 3) 9)|Make: 100A(Lamp, Inrush current)<br>Break: 60A (Resistive)| |Max. switching voltage 4)|75VDC| |Min.contact load 5)|1A 12VDC| |Electrical endurance|See " CONTACT DATA "| |Mechanical endurance|1x107OPS(300OPS/min)| |Initial insulation resistance|500M<br>(at 500VDC)| |Withstand voltage 6)|between contacts: 500VAC<br>between coil & contacts: 500VAC| |Operate time 10)|Typ.: 5ms<br>Max.: 10ms (at nomi. vol.)| |Release time 7) 10)|Typ.: 3ms<br>Max.: 10ms| |Ambient temperature|-40<br>to 125| |Vibration resistance 8) 10)|10Hz to 40Hz 1.27mm DA<br>40Hz to 70Hz 49m/s2<br>70Hz to 100Hz 0.5mm DA<br>100Hz to 500Hz 98m/s2| Shock resistance[8)][10)] 98m/s[2] Termination PCB[9)] Construction Plastic sealed Unit weight Approx. 20g - 1) Equivalent to the max. initial contact resistance is 100m (at 1A 6VDC). - 2) Test under the following conditions: - a.The relay is mounted on the PCB,the coil is applied with 100% rated votage; - b.The PCB board is a double layer board. The thickness of the copper foil is 4 oz (140µm),the width of each copper foil is 5.4x(1 5%)mm, the length of the copper foil is (50 1)mm,and the Tg value of the PCB board is 150 ; - c.The sample orders were only tested. - d.It varies by connection conditions. Additionally, reliable performance under repeated power-on cannot be guaranteed. Verify based on actual operating conditions during use. - 3) For NO contacts, at 23 , 13.5VDC, resistive load (100 cycles). - 4) For NO contacts, see "Load limit curve" for details. - 5) Lower limit target for on-off operation at low load. This value varies by on-off frequency, environmental conditions and expected reliability level; verify with actual load during use . - 6) 1min, leakage current less than 1mA. - 7) The value is measured when voltage drops suddenly from nominal voltage to 0 VDC and coil is not paralleled with suppression circuit. - 8) When energized, opening time of NO contacts shall not exceed 100µs, when non-energized, opening time of NC contacts shall not exceed 1ms, meantime, NO contacts shall not be closed. - 9) Since it is an environmental friendly product, please select lead-free solder when welding. The recommended soldering temperature and time is (260 3) , (5 0.5)s. - 10) Only for the 12VDC coil voltage type. ## **CONTACT DATA**[3)] |Load<br>voltage<br>13.5VDC|Load type<br>Resistive<br>Make<br>Break|Load type<br>Resistive<br>Make<br>Break|Load current A|Load current A|Load current A|On/Off ratio|On/Off ratio|Electrical<br>endurace|Contact<br>material|Load wiring<br>diagram2)| |---|---|---|---|---|---|---|---|---|---|---| ||||1C||1A|On<br>s|Off<br>s|||| ||||NO|NC||||||| |||Make|45|30|45|1.5|1.5|1×105OPS|AgSnO2|See<br>diagram 1| |||Break|45|30|45|||||| ||Flasher1)||2×21W+5W|—|2×21W+5W|0.375|0.375|1000h|Special<br>AgSnO2|See<br>diagram 2| ||||4×21W+2×5W|—|4×21W+2×5W|0.375|0.375|360h||| ## HONGFA RELAY ISO9001, IATF16949 , ISO14001, ISO45001, IECQ QC 080000, ISO/IEC 27001 CERTIFIED 2025 Rev. 2.00 87 **Notes:** 1) When it is utilized in flasher, a special AgSnO2 contact material should be used and the customer special code should be (170) as a suffix. Please connect by the polarity according to the diagram below. 2) The load wiring diagrams are listed below: **==> picture [240 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> COM<br>COM COM<br>NO<br>NO NC NO NC<br>Resistive Resistive Flasher<br>R R<br>_<br>diagram 1 diagram 2<br>**----- End of picture text -----**<br> - 3) When the load voltage is at 24VDC or higher, or the applications conditions are different from the table above, please submit the detailed application conditions to Hongfa to get more support. ## **COIL DATA** |**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23|**COIL DATA**<br>at 23| |---|---|---|---|---|---|---|---|---|---| |Coil Power|Nominal voltage<br>VDC|Pick-up voltage<br>VDC.<br>max.|||Drop-out voltage<br>VDC<br>min.|||x(1<br>10%)<br>Coil resistance|Power<br>consumption<br>W| |||23|85|125|23|85|125||| |Standard|6|3.3|4.1|4.7|0.6|0.7|0.8|19|1.9| ||12|6.8|8.5|9.7|1.2|1.5|1.7|90|1.6| ||24|13.9|17.3|19.9|2.4|3.0|3.3|362|1.6| |Sensitive|6|4.5|5.6|6.4|0.6|0.7|0.8|30|1.2| ||12|9.0|11.2|12.9|1.2|1.5|1.7|120|1.2| ||24|19.2|23.9|27.4|2.4|3.0|3.3|480|1.2| ||||||||||| ## **ORDERING INFORMATION** HFKP / 012 -1H 4 T S (XXX) **Type Coil voltage 006** : 6VDC **012** : 12VDC **024** : 24VDC **Contact arrangement 1H** : 1 Form A **1Z** : 1 Form C **Version** 1) **4** : European Plastic sealed model **6** : European Plastic sealed model, 3 yoke terminals **Contact Material T** : AgSnO2 **Coil Power S** : Sensitive **Nil** : Standard **Special code**[2)] **XXX:** Customer special requirement **Nil:** Standard **Notes:** 1)Contact us for suitable soldering conditions and product specifications if post-soldering cleaning or surface treatment is required after the relays are soldered onto the PCB. 2)The customer special requirement express as special code after evaluating by Hongfa. e.g. (170) stands for flasher load.The performance parameters of products with characteristic numbers shall be subject to the specific specifications provided by Hongfa. 88 **OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT** Unit: mm ## Outline Dimensions ## HFKP/ □□□ -1 □ 4 □□ (XXX) **==> picture [161 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 10.1 0.3 *<br>5.9 0.3<br>+0.2<br>2×1.8 0.1 ( 1 Form C 1x ) 2x1.2 - 0.1<br>13.2 0.3<br>2.2 0.3<br>2×1.8 0.1<br>26.5max<br>**----- End of picture text -----**<br> **==> picture [73 x 67] intentionally omitted <==** **==> picture [19 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 22max<br>**----- End of picture text -----**<br> **==> picture [76 x 44] intentionally omitted <==** ## HFKP/ □□□ -1 □ 6 □□ (XXX) **==> picture [171 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> 15.9 0.3 *<br>10.1 0.3 *<br>5.9 0.3<br>+0.2<br>2×1.8 0.1 ( 1 Form C 1x ) 2x1.2 - 0.1<br>13.2 0.3<br>2.2 0.3<br>3×1.8 0.1<br>26.5max<br>**----- End of picture text -----**<br> **==> picture [74 x 70] intentionally omitted <==** **==> picture [19 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> 22max<br>**----- End of picture text -----**<br> **==> picture [77 x 47] intentionally omitted <==** 89 **OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT** Unit: mm PCB Layout (Bottom view) HFKP/ □□□ -1 □ 4 □□ (XXX) HFKP/ □□□ -1 □ 6 □□ (XXX) **==> picture [132 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> (3.72.2) +0.20 10.1 2× 1.6 +0.20<br>5.9<br>2.2 2.2 +0.20<br>13.2<br>**----- End of picture text -----**<br> **==> picture [133 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> (3.7) 15.9<br>2.2 +0.20 2× 1.6 +0.20<br>10.1<br>5.9<br>2 +0.20<br>2.2 2.2 +0.20<br>13.2<br>**----- End of picture text -----**<br> Remark: 1) ***** The additional tin top is max. 1mm. - 2) The tolerance without indicating is always ±0.1mm. - 3) means that the mounting hole doesn't exist for HFKP/ □□□ -1H □□□ (XXX) type. Wiring Diagram (Bottom view) HFKP/ □□□- 1H4 □□ (XXX) HFKP/ □□□-1 Z4 □□ (XXX) **==> picture [286 x 58] intentionally omitted <==** HFKP/ □□□ -1H6 □□ (XXX) HFKP/ □□□ -1Z6 □□ (XXX) **==> picture [69 x 57] intentionally omitted <==** **==> picture [69 x 57] intentionally omitted <==** 90 Unit: mm ## **CHARACTERISTIC CURVES** ## CHARACTERISTIC CURVES ## 1. Coil operating voltage range **==> picture [223 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> 130<br>120<br>110<br>100<br>90 0A<br>8A<br>80<br>16A<br>70<br>24A<br>60<br>32A<br>50<br>40<br>40A<br>30<br>90 95 100 105 110 115 120 125 130 135 140 145 150<br>**----- End of picture text -----**<br> - 1) The maximum allowable coil temperature is 180 . For the coil temperature rise which is measured by resistance is average value, we recommend the coil temperature should be below 170 under the different application ambient, different coil voltage and different load etc. - 2) If the actual operating coil voltage is out of the specified range, please contact Hongfa for further details. Percentage of nominal coil voltage ## 2. Load limit curve (at 23 ) **==> picture [206 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> 75<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0.5 1 2 3 4 5 7 10 20 30 45<br>Switching current (A)<br>**----- End of picture text -----**<br> - 1) This chart takes NO contact, Resistive load as example. - 2) The load and electrical endurance tests are made according to “CONTACT DATA” parameters’ table. If actual load voltage, current, operate frequency, or ambient temperature is different from “CONTACT DATA” table, please arrange corresponding tests for confirmation. ## Disclaimer The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. In case there is specific criterion (such as mission profile, technical specification, PPAP etc.) checked and agreed by and between customer and Hongfa, this specific criterion should be taken as standard regarding any requirement on Hongfa product. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s responsibility to determine which product should be used only. > © Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved. 91
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →