Image not available
Illustrative purposes only
HEP-600C-24
SINGLE OUTPUT BATTERY CHARGER, 600W, 24V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: -
- Product Range: HEP-600C Series
- Charge Current: 10.5A to 21A
- Output Voltage: 23V to 30.2V
- Supply Voltage: 305VAC
- Battery Size Code: -
- Battery Charger Type: Desktop
- No. of Cells Charged: -
- Battery Technologies Supported: Lead Acid, Li-Ion
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 194.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- HEP 600C series** 600W Single Output Battery Charger ## TAIWAN 5 ## ■ ## ■ **==> picture [14 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>**----- End of picture text -----**<br> ## ℃ ## ■ ℃ ## ■ _File Name:HEP-600C-SPEC 2018-04-26_ **- HEP 600C series** ## 600W Single Output Battery Charger reer reer e eee eee ee ## **SPECIFICATION** |**HEP-600C-12**<br>**HEP-600C-24**<br>**HEP-600C-48**<br>**MODEL**<br>**BOOST CHARGE VOLTAGE Vboost**<br>**FLOAT CHARGE VOLTAGE Vfloat**<br>**OUTPUT CURRENT**<br>**BATTERY TYPE**<br>**RECOMMENDED BATTERY**<br>**CAPACITY(AMP HOURS)(Note 3)**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>14.4V<br>28.8V<br>57.6V<br>13.6V<br>11.5 ~ 15.1V<br>17.5 ~ 35A<br>35A<br>Open & Sealed Lead Acid<br>135 ~ 400AH<br>27.2V<br>23 ~ 30.2V<br>10.5 ~ 21A<br>54.4V<br>46.1 ~ 60.5V<br>5.2 ~ 10.5A<br>21A<br>10.5A<br>70 ~ 210AH<br>35 ~ 105AH<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>93.5%<br>94.5%<br>95.5%<br>7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC<br><0.75mA / 277VAC<br>16.5 ~ 20.5V<br>32.5 ~ 36.5V<br>68 ~ 73V<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 60<br>)<br>20 ~ 500Hz, 10G 10min./1cycle, 72min. each along X, Y, Z axes<br>**NOTE**<br>℃<br>℃<br>℃<br>**POWER FACTOR (Typ.)**<br>PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**SAFETY STANDARDS**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**PACKING**<br>Compliance to<br>,<br>EN55032 (CISPR32), radiation class A, conduction class B, EN61000-3-2,-3 EAC TP TC 020<br>Compliance to<br>,<br>EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level EAC TP TC 020<br>UL60950-1, TUV EN60950-1 EAC TP TC 004 approved<br>,<br>73.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>280*144*48.5mm (L*W*H)<br>3.9Kg; 4pcs/16Kg/0.9CUFT<br>**SAFETY &**<br>**EMC**<br>**(Note.4)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**EFFICIENCY (Typ.)**<br>COLD START 70A(t<br>=1010 s measured at 50% I<br>) at 230VAC<br>width<br>peak<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>**FUNCTION**<br>**REMOTE ON/OFF CONTROL**<br>**5V STANDBY**<br>Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit<br>5V<br>: 5V@0.5A ; tolerance<br>5%, ripple : 100mVp-p(max.)<br>SB<br>±<br>μ<br>~~eG~~<br>a<br>ee<br>~~eG~~<br>ER~~Pf~~<br>a<br>ee<br>ee<br>a<br>ee<br>~~ee~~<br>a<br>~~aCR~~<br>a<br>a<br>~~ee~~<br>a~~ee~~<br>a<br>a<br>a<br>a<br>a~~ee~~<br>a<br>a<br>**a**~~a~~<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25<br>of ambient temperature.<br>3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**HEP-600C-12**<br>**HEP-600C-24**<br>**HEP-600C-48**<br>**MODEL**<br>**BOOST CHARGE VOLTAGE Vboost**<br>**FLOAT CHARGE VOLTAGE Vfloat**<br>**OUTPUT CURRENT**<br>**BATTERY TYPE**<br>**RECOMMENDED BATTERY**<br>**CAPACITY(AMP HOURS)(Note 3)**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>**AC CURRENT (Typ.)**<br>14.4V<br>28.8V<br>57.6V<br>13.6V<br>11.5 ~ 15.1V<br>17.5 ~ 35A<br>35A<br>Open & Sealed Lead Acid<br>135 ~ 400AH<br>27.2V<br>23 ~ 30.2V<br>10.5 ~ 21A<br>54.4V<br>46.1 ~ 60.5V<br>5.2 ~ 10.5A<br>21A<br>10.5A<br>70 ~ 210AH<br>35 ~ 105AH<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>93.5%<br>94.5%<br>95.5%<br>7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC<br><0.75mA / 277VAC<br>16.5 ~ 20.5V<br>32.5 ~ 36.5V<br>68 ~ 73V<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 60<br>)<br>20 ~ 500Hz, 10G 10min./1cycle, 72min. each along X, Y, Z axes<br>**NOTE**<br>℃<br>℃<br>℃<br>**POWER FACTOR (Typ.)**<br>PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**SAFETY STANDARDS**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**PACKING**<br>Compliance to<br>,<br>EN55032 (CISPR32), radiation class A, conduction class B, EN61000-3-2,-3 EAC TP TC 020<br>Compliance to<br>,<br>EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level EAC TP TC 020<br>UL60950-1, TUV EN60950-1 EAC TP TC 004 approved<br>,<br>73.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>280*144*48.5mm (L*W*H)<br>3.9Kg; 4pcs/16Kg/0.9CUFT<br>**SAFETY &**<br>**EMC**<br>**(Note.4)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**EFFICIENCY (Typ.)**<br>COLD START 70A(t<br>=1010 s measured at 50% I<br>) at 230VAC<br>width<br>peak<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>**FUNCTION**<br>**REMOTE ON/OFF CONTROL**<br>**5V STANDBY**<br>Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit<br>5V<br>: 5V@0.5A ; tolerance<br>5%, ripple : 100mVp-p(max.)<br>SB<br>±<br>μ<br>~~eG~~<br>a<br>ee<br>~~eG~~<br>ER~~Pf~~<br>a<br>ee<br>ee<br>a<br>ee<br>~~ee~~<br>a<br>~~aCR~~<br>a<br>a<br>~~ee~~<br>a~~ee~~<br>a<br>a<br>a<br>a<br>a~~ee~~<br>a<br>a<br>**a**~~a~~<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25<br>of ambient temperature.<br>3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**HEP-600C-12**|**HEP-600C-24**|**HEP-600C-48**| |---|---|---|---|---| ||**BOOST CHARGE VOLTAGE Vboost**<br>~~eG~~|14.4V<br>~~eG~~|28.8V<br>~~eG~~|57.6V<br>~~eG~~| ||**FLOAT CHARGE VOLTAGE Vfloat**<br>a<br>ee|13.6V|27.2V|54.4V| ||**VOLTAGE ADJ. RANGE**<br>a<br>ee|11.5 ~ 15.1V|23 ~ 30.2V|46.1 ~ 60.5V| ||**CURRENT ADJ. RANGE**<br>ee<br>~~eG~~|17.5 ~ 35A<br>~~eG~~|10.5 ~ 21A<br>~~eG~~|5.2 ~ 10.5A<br>~~eG~~| ||**RECOMMENDED BATTERY**<br>**CAPACITY(AMP HOURS)(Note 3)**<br>~~eG~~<br>ER|135 ~ 400AH<br>~~eG~~<br>|70 ~ 210AH<br>~~eG~~<br>|35 ~ 105AH<br>~~eG~~<br>| ||**BATTERY TYPE**<br>ER|Open & Sealed Lead Acid<br>||| ||**OUTPUT CURRENT**<br>ER~~Pf~~|35A<br>~~Pf~~|21A<br>~~Pf~~|10.5A<br>~~Pf~~| ||**VOLTAGE RANGE**<br>a<br>ee|90 ~ 305VAC 127 ~ 431VDC||| ||**FREQUENCY RANGE**<br>ee<br>ee|47 ~ 63Hz||| ||**POWER FACTOR (Typ.)**<br>ee<br>ee|PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load||| ||**EFFICIENCY (Typ.)**<br>ee<br>a<br>ee|93.5%|94.5%|95.5%| ||**AC CURRENT (Typ.)**<br>ee|7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC||| ||**INRUSH CURRENT (Typ.)**<br>ee<br>~~ee~~<br>a|COLD START 70A(t<br>=1010 s measured at 50% I<br>) at 230VAC<br>width<br>peak<br>μ<br>~~ee~~<br>~~a~~||| ||**LEAKAGE CURRENT**<br>~~ee~~<br>a|<0.75mA / 277VAC<br>~~ee~~<br>~~a~~||| ||**OVER VOLTAGE**<br>a<br>a|16.5 ~ 20.5V<br>32.5 ~ 36.5V<br>68 ~ 73V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~aCR~~||| ||**OVER TEMPERATURE**<br>a|Shut down o/p voltage, re-power on to recover<br>~~CR~~||| ||**REMOTE ON/OFF CONTROL**<br>a<br>a|Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit<br>~~CR~~||| ||**5V STANDBY**<br>a<br>~~ee~~<br>a|5V<br>: 5V@0.5A ; tolerance<br>5%, ripple : 100mVp-p(max.)<br>SB<br>±<br>~~ee~~<br>||| ||**WORKING TEMP.**<br>a|-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>||| ||**WORKING HUMIDITY**<br>a~~ee~~|20 ~ 95% RH non-condensing<br>~~ee~~||| ||**STORAGE TEMP., HUMIDITY**<br>~~ee~~<br>a<br>a|-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing<br>~~ee~~||| ||**TEMP. COEFFICIENT**<br>a<br>a|±<br>℃<br>℃<br>0.05%/<br>(0 ~ 60<br>)||| ||**VIBRATION**<br>a<br>a<br>a|20 ~ 500Hz, 10G 10min./1cycle, 72min. each along X, Y, Z axes||| ||**SAFETY STANDARDS**<br>a<br>a|UL60950-1, TUV EN60950-1 EAC TP TC 004 approved<br>,<br>||| ||**WITHSTAND VOLTAGE**<br>a<br>a~~ee~~|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>~~ee~~||| ||**ISOLATION RESISTANCE**<br>a~~ee~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~ee~~||| ||**EMC EMISSION**<br>a<br>a|Compliance to<br>,<br>EN55032 (CISPR32), radiation class A, conduction class B, EN61000-3-2,-3 EAC TP TC 020||| ||**EMC IMMUNITY**<br>a<br>a<br>**a**|Compliance to<br>,<br>EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level EAC TP TC 020<br>||| ||**MTBF**<br>a<br>**a**|73.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>||| ||**DIMENSION**<br>**a**|280*144*48.5mm (L*W*H)<br>||| ||**PACKING**<br>~~a~~|3.9Kg; 4pcs/16Kg/0.9CUFT<br>~~a~~||| ||℃<br>℃<br>℃<br>~~a~~<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25<br>of ambient temperature.<br>3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|||| ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft). _File Name:HEP-600C-SPEC 2018-04-26_ ## 600W Single Output Battery Charger ## **- HEP 600C series** ## **Block Diagram** **==> picture [475 x 373] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 70KHz<br>+5VSB<br>DETECTION<br>CIRCUIT<br>RECTIFIERS<br>POWER SWITCHING<br>& +5VSB<br>PWM CONTROL<br>FILTER<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P.<br>DETECTION<br>FG O.L.P.<br>PWM & PFC CIRCUIT<br>PFC CONTROL<br>CONTROL<br>O.V.P.<br>PS/ON<br>PS/ON<br>CONTROL<br>Charging Curve<br>Start<br>Vboost<br>Vfloat<br>Charge Voltage Factory default value:<br>100% State HEP-600C-12 HEP-600C-24 HEP-600C-48<br>Constant Current 35A 21A 10.5A<br>50%<br>Vboost 14.4V 28.8V 57.6V<br>Charge Current Constant Current Constant 10% Vfloat 13.6V 27.2V 54.4V<br>Voltage<br>stage 1 stage 2 stage 3<br>Color of LED<br>Red Yellow Green<br>Loading Indicator<br>**----- End of picture text -----**<br> ## **Charging Curve** **==> picture [471 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-40 -25 -10 0 15 30 50 55 60 70 (HORIZONTAL) 90 115 125 135 145 155 165 175 180 200 230 305<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HEP-600C-SPEC 2018-04-26_ **- HEP 600C series** ## 600W Single Output Battery Charger **==> picture [481 x 367] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No.228A Unit:mm<br>280<br>13.4 253.2<br>8.9<br>5.7<br>1<br>2<br>1 3<br>I/P 2 4<br>O/P<br>3 5<br>T case 126.6 6<br>Io Vo 7<br>ADJ. ADJ.<br>ψ6×4PL<br>LED<br>5.7 268.6<br>※ T case: Max. Case Temperature.<br>21max. 21max.<br>※ Output voltage and constant current level can be adjusted through internal potentiometer.<br>(Can access by removing the rubber stopper on the case.)<br>11<br>113<br>9.25<br>48.5<br>47<br>144<br>7<br>11<br>9.25<br>7<br>**----- End of picture text -----**<br> AC Input Terminal Pin No. Assignment DC Output Terminal Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment 1 FG 1 RC+ 4,5 -V 2 AC/L 2 RC- & GND 6,7 +V 3 AC/N 3 +5VSB _File Name:HEP-600C-SPEC 2018-04-26_
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →