Image not available
Illustrative purposes only
HEP-600-36
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 601.2 W, 36 VDC, 16.7 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:601.2W; Output Voltage - Output 1:36V; Output Current - Output 1:16.7A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HEP-600 Series
- No. of Outputs: 1Outputs
- Output Power Max: 601.2W
- Input Voltage VAC: 90V AC to 305V AC
- Input Voltage AC Max: 305V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 16.7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 182.87 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- HEP 600 series** 600W Single Output Switching Power Supply **==> picture [32 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> TAIWAN 5<br>■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [14 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>**----- End of picture text -----**<br> ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> > ℃ and+70 ℃ _ under free air convection. **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:HEP-600-SPEC 2016-10-27_ 600W Single Output Switching Power Supply ## **- HEP 600 series** ## **SPECIFICATION** |**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.5**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Can be adjusted by internalpotentiometer<br>500ms, 80ms at full load 230VAC /115VAC<br>15ms at full load 230VAC /115VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load<br>7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC<br><0.75mA / 277VAC<br>105 ~ 125%<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>Compliance toEN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance toEN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>UL60950-1, TUV EN60950-1approved<br>76.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>280*144*48.5mm (L*W*H)<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**PROTECTION SHORT CIRCUIT**<br>Constant current limiting, recovers automatically after fault condition is removed<br>13 ~ 16V<br>16.5 ~ 20.5V 22 ~ 26V<br>26 ~ 30V<br>32.5 ~ 36.5V 39.5 ~ 43.5V<br>52.5 ~ 56.5V<br>46 ~ 50V<br>59 ~ 63V<br>93%<br>94%<br>95%<br>95%<br>95.5%<br>95.5%<br>96%<br>96%<br>96%<br>±3.0%<br>20 ~ 40A<br>±2.0%<br>18 ~ 36A<br>±1.5%<br>14 ~ 28A<br>±1.0%<br>12.5 ~ 25A<br>±1.0%<br>10 ~ 20A<br>±1.0%<br>8.3 ~ 16.7A<br>±1.0%<br>6.2 ~ 12.5A<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>5.6 ~ 11.2A<br>±0.5%<br>±0.5%<br>±1.0%<br>7.1 ~ 14.3A<br>±0.5%<br>±0.5%<br>12V<br>**HEP-600-12**<br>**HEP-600-15**<br>**HEP-600-20**<br>**HEP-600-24**<br>**HEP-600-30**<br>**HEP-600-36**<br>**HEP-600-42**<br>**HEP-600-48**<br>**HEP-600-54**<br>15V<br>20V<br>24V<br>30V<br>36V<br>48V<br>40A<br>36A<br>28A<br>25A<br>20A<br>16.7A<br>12.5A<br>480W<br>540W<br>560W<br>600W<br>600W<br>601.2W<br>600W<br>150mVp-p<br>150mVp-p<br>12.7 ~ 15.8V<br>150mVp-p<br>17 ~ 21V<br>150mVp-p<br>20.4 ~ 25.2V<br>200mVp-p<br>25.5 ~ 31.5V<br>250mVp-p<br>30.6 ~ 37.8V<br>250mVp-p<br>40.8 ~ 50.4V<br>10.2 ~ 12.6V<br>54V<br>11.2A<br>604.8W<br>350mVp-p<br>45.9 ~ 56.7V<br>42V<br>14.3A<br>600.6W<br>250mVp-p<br>35.7 ~ 44.1V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>COLD START 70A(t<br>=1000 s measured at 50% I<br>) at 230VAC<br>width<br>peak<br>**FUNCTION REMOTE ON/OFF CONTROL** Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit<br>**5V STANDBY**<br>5V<br>: 5V@0.5A ; tolerance<br>5%, ripple : 100mVp-p(max.)<br>SB<br>±<br>**PACKING**<br>3.9Kg; 4pcs/16.6Kg/0.9CUFT<br>**NOTE**<br>℃<br>℃<br>μ<br>~~rae~~<br>-<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the static characteristics for more details.<br>5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m is needed for operating altitude greater than 2000m(6500ft).|**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.5**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>Can be adjusted by internalpotentiometer<br>500ms, 80ms at full load 230VAC /115VAC<br>15ms at full load 230VAC /115VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load<br>7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC<br><0.75mA / 277VAC<br>105 ~ 125%<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>Compliance toEN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance toEN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A<br>-40 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>UL60950-1, TUV EN60950-1approved<br>76.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>280*144*48.5mm (L*W*H)<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**PROTECTION SHORT CIRCUIT**<br>Constant current limiting, recovers automatically after fault condition is removed<br>13 ~ 16V<br>16.5 ~ 20.5V 22 ~ 26V<br>26 ~ 30V<br>32.5 ~ 36.5V 39.5 ~ 43.5V<br>52.5 ~ 56.5V<br>46 ~ 50V<br>59 ~ 63V<br>93%<br>94%<br>95%<br>95%<br>95.5%<br>95.5%<br>96%<br>96%<br>96%<br>±3.0%<br>20 ~ 40A<br>±2.0%<br>18 ~ 36A<br>±1.5%<br>14 ~ 28A<br>±1.0%<br>12.5 ~ 25A<br>±1.0%<br>10 ~ 20A<br>±1.0%<br>8.3 ~ 16.7A<br>±1.0%<br>6.2 ~ 12.5A<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>5.6 ~ 11.2A<br>±0.5%<br>±0.5%<br>±1.0%<br>7.1 ~ 14.3A<br>±0.5%<br>±0.5%<br>12V<br>**HEP-600-12**<br>**HEP-600-15**<br>**HEP-600-20**<br>**HEP-600-24**<br>**HEP-600-30**<br>**HEP-600-36**<br>**HEP-600-42**<br>**HEP-600-48**<br>**HEP-600-54**<br>15V<br>20V<br>24V<br>30V<br>36V<br>48V<br>40A<br>36A<br>28A<br>25A<br>20A<br>16.7A<br>12.5A<br>480W<br>540W<br>560W<br>600W<br>600W<br>601.2W<br>600W<br>150mVp-p<br>150mVp-p<br>12.7 ~ 15.8V<br>150mVp-p<br>17 ~ 21V<br>150mVp-p<br>20.4 ~ 25.2V<br>200mVp-p<br>25.5 ~ 31.5V<br>250mVp-p<br>30.6 ~ 37.8V<br>250mVp-p<br>40.8 ~ 50.4V<br>10.2 ~ 12.6V<br>54V<br>11.2A<br>604.8W<br>350mVp-p<br>45.9 ~ 56.7V<br>42V<br>14.3A<br>600.6W<br>250mVp-p<br>35.7 ~ 44.1V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>COLD START 70A(t<br>=1000 s measured at 50% I<br>) at 230VAC<br>width<br>peak<br>**FUNCTION REMOTE ON/OFF CONTROL** Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit<br>**5V STANDBY**<br>5V<br>: 5V@0.5A ; tolerance<br>5%, ripple : 100mVp-p(max.)<br>SB<br>±<br>**PACKING**<br>3.9Kg; 4pcs/16.6Kg/0.9CUFT<br>**NOTE**<br>℃<br>℃<br>μ<br>~~rae~~<br>-<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the static characteristics for more details.<br>5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m is needed for operating altitude greater than 2000m(6500ft).|**HEP-600-12**|**HEP-600-15**|**HEP-600-20**|**HEP-600-24**|**HEP-600-30**|**HEP-600-36**|**HEP-600-42**|**HEP-600-48**|**HEP-600-54**| |---|---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|12V|15V|20V|24V|30V|36V|42V|48V|54V| ||**RATED CURRENT**|40A|36A|28A|25A|20A|16.7A|14.3A|12.5A|11.2A| ||**RATED POWER**|480W|540W|560W|600W|600W|601.2W|600.6W|600W|604.8W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|150mVp-p|150mVp-p|150mVp-p|200mVp-p|250mVp-p|250mVp-p|250mVp-p|350mVp-p| ||**VOLTAGE ADJ. RANGE**|10.2 ~ 12.6V|12.7 ~ 15.8V|17 ~ 21V|20.4 ~ 25.2V|25.5 ~ 31.5V|30.6 ~ 37.8V|35.7 ~ 44.1V|40.8 ~ 50.4V|45.9 ~ 56.7V| ||**CURRENT ADJ. RANGE**|Can be adjusted by internalpotentiometer<br>20 ~ 40A<br>18 ~ 36A<br>14 ~ 28A<br>12.5 ~ 25A<br>10 ~ 20A<br>8.3 ~ 16.7A<br>6.2 ~ 12.5A<br>5.6 ~ 11.2A<br>7.1 ~ 14.3A||||||||| ||**VOLTAGE TOLERANCE Note.3**|±3.0%|±2.0%|±1.5%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**LOAD REGULATION**|±2.0%|±1.5%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**<br>**Note.5**|500ms, 80ms at full load 230VAC /115VAC||||||||| ||**HOLD UP TIME (Typ.)**|15ms at full load 230VAC /115VAC||||||||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 305VAC 127 ~ 431VDC||||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||||||| ||**POWER FACTOR (Typ.)**|PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load||||||||| ||**EFFICIENCY (Typ.)**|93%|94%|95%|95%|95.5%|95.5%|96%|96%|96%| ||**AC CURRENT (Typ.)**|7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC||||||||| ||**INRUSH CURRENT(Typ.)**|COLD START 70A(t<br>=1000 s measured at 50% I<br>) at 230VAC<br>width<br>peak<br>μ||||||||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC||||||||| ||**OVER CURRENT**<br>~~rae~~|105 ~ 125%<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>~~rae~~||||||||| ||**SHORT CIRCUIT**<br>~~rae~~|Constant current limiting, recovers automatically after fault condition is removed<br>~~rae~~||||||||| ||**OVER VOLTAGE**<br> <br>~~rae~~|Protection type : Shut down o/p voltage, re-power on to recover<br>13 ~ 16V<br>16.5 ~ 20.5V 22 ~ 26V<br>26 ~ 30V<br>32.5 ~ 36.5V 39.5 ~ 43.5V<br>52.5 ~ 56.5V<br>46 ~ 50V<br>59 ~ 63V<br>~~rae~~||||||||| ||**OVER TEMPERATURE**<br>~~rae~~|Shut down o/p voltage, re-power on to recover<br>~~rae~~||||||||| ||**REMOTE ON/OFF CONTROL** <br>~~rae~~|Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit<br>~~rae~~||||||||| ||<br>**5V STANDBY**|5V<br>: 5V@0.5A ; tolerance<br>5%, ripple : 100mVp-p(max.)<br>SB<br>±||||||||| ||**WORKING TEMP.**|-40 ~ +70<br>(Refer to "Derating Curve")<br>℃||||||||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃||||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)||||||||| ||**VIBRATION**|20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes||||||||| ||**SAFETY STANDARDS**|UL60950-1, TUV EN60950-1approved||||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC||||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||||| ||**EMC EMISSION**|Compliance toEN55022 (CISPR22) Class B, EN61000-3-2,-3||||||||| ||**EMC IMMUNITY**|Compliance toEN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A||||||||| ||**MTBF**|76.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||||| ||**DIMENSION**|280*144*48.5mm (L*W*H)||||||||| ||**PACKING**|3.9Kg; 4pcs/16.6Kg/0.9CUFT||||||||| ||℃<br>℃<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the static characteristics for more details.<br>5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m is needed for operating altitude greater than 2000m(6500ft).|||||||||| ℃ _File Name:HEP-600-SPEC 2016-10-27_ **- HEP 600 series** ## 600W Single Output Switching Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 70KHz<br>+5VSB<br>DETECTION<br>CIRCUIT<br>RECTIFIERS<br>POWER SWITCHING<br>& +5VSB<br>PWM CONTROL<br>FILTER<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P.<br>DETECTION<br>FG O.L.P.<br>PWM & PFC CIRCUIT<br>PFC CONTROL<br>CONTROL<br>O.V.P.<br>PS/ON<br>PS/ON<br>CONTROL<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-40 -25 -10 0 15 30 50 55 60 70 (HORIZONTAL) 90 115 125 135 145 155 165 175 180 200 230 305<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HEP-600-SPEC 2016-10-27_ **- HEP 600 series** ## 600W Single Output Switching Power Supply **==> picture [103 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>**----- End of picture text -----**<br> **==> picture [417 x 362] intentionally omitted <==** **----- Start of picture text -----**<br> Case No. 228A Unit:mm<br>280<br>13.4 253.2<br>8.9<br>5.7<br>1<br>2<br>1 3<br>I/P 2 4<br>O/P<br>3 5<br>T case 126.6 6<br>Io Vo 7<br>ψ4.5×4PL ADJ. ADJ.<br>ψ6×4PL<br>LED<br>5.7 268.6<br>※ T case: Max. Case Temperature.<br>21max. 21max.<br>※ Output voltage and constant current level can be adjusted through internal potentiometer.<br>(Can access by removing the rubber stopper on the case.)<br>15<br>11<br>97<br>9.25<br>15<br>48.5<br>47<br>144<br>7<br>11<br>9.25<br>7<br>**----- End of picture text -----**<br> AC Input Terminal Pin No. Assignment DC Output Terminal Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment 1 FG 1 RC+ 4,5 -V 2 AC/L 2 RC- & GND 6,7 +V 3 AC/N 3 +5VSB **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HEP-600-SPEC 2016-10-27_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →