HDS800PS48
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 800 W, 48 VDC, 16.7 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:800W; Output Voltage - Output 1:48V; Output Current - Output 1:16.7A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (17-Jan-2023)
- Product Range: HDS800 Series
- No. of Outputs: 1Outputs
- Output Power Max: 800W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 16.7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 342.11 € |
| Current stock | 10+ |
| Lead time | 30 days |
**800 Watts** xppower.com ## **HDS800 Series** - High Efficiency up to 92% - 1U Profile, High Power Density - Programmable Output Voltage (0-105%) - Programmable Output Current (0-105%) - Parallel Operation - Fully Featured Signals & Controls - 3 Year Warranty ## ~~**Specification**~~ ## **Input** - Input Voltage • 90-264 VAC (127-370 VDC), see derating curve - Input Frequency • 47-63 Hz Input Current • 9.3 A/3.7 A typical at 100/240 VAC Inrush Current • 30.0 A/60.0 A typical at 115/230 VAC Power Factor • 0.98/0.95, typical at 115/230 VAC full load Earth Leakage Current • <1.0 mA at 264 VAC/60 Hz Input Protection • T or F15 A/250 V internal fuse ## **Output** - Output Voltage • See model table Output Trim • ±5.0% by potentionmeter Output Voltage Program • 0-105% of rated output Output Current Program • 0-105% of rated output Initial Set Accuracy • ±1% Minimum Load • No minimum load required Start Up Delay • 800 ms maximum Start Up Rise Time • 100 ms maximum at full load Hold Up Time • 8 ms minimum Line Regulation • ±1% Load Regulation • V1: ±1%, standby output: ±3% Transient Response • <1% for a 25% step load change Ripple & Noise • 150 mV pk-pk all voltages, see note 1 Overvoltage Protection • Tracks output voltage. See application notes, Recycle AC to reset - Overtemperature • Primary and secondary heatsinks monitored. Protection Output shuts down, auto recovers Overload Protection • >105% rated power, constant current Short Circuit Protection • Auto recovery Temperature • ±0.02%/ ˚ C (0-50 ˚ C) Coefficient Remote Sense • Compensates for 0.5 V max voltage drop If remote sense is not required, local sense must be used - Enable • Output must be enabled. See application notes, power supply is shipped with enable links fitted - Current Share • 5 supplies can share within 5% Standby Output • 5 V at 0.5 A, present whenever AC is applied (9V at 0.3A, user selectable, by connecting ‘VSET’, Pin 8 of CN2 to ‘GND’) ## **General** - Efficiency • See model table Isolation • 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground - Switching Frequency • PFC 65 kHz typical, PWM 40-200 kHz variable - Power Density • 10.1 W/in[3] Signals & Controls • Enable, Current Share, V Program, I Program, 5 V Standby, PWM switching - MTBF • 90 kHrs to MIL-HDBK-217F at 25 ˚ C ## **Environmental** Operating Temperature • -20 ˚ C to 70 ˚ C, derate linearly from 100% load at 50 ˚ C to 50% load at 70 ˚ C - Cooling • Internal fan fitted. Speed increases with load and internal temperature - Operating Humidity • 20-90% R.H. non-condensing Storage Temperature • -40 ˚ C to +85 ˚ C Storage Humidity • 10-95% R.H. Vibration • 10-500 Hz, 2g 10 min/cycle, 60 min period for each axis. Compliant to IEC68-2-6, IEC 68-2-64 ## **EMC & Safety** - Emissions • EN55032 class A conducted & radiated Harmonic Currents • EN61000-3-2 class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, ±4 kV contact, ±8 kV air discharge, Perf Criteria A - Radiated Immunity • EN61000-4-3, 3 V/m, Perf Criteria A EFT/Burst • EN61000-4-4, level 2, Perf Criteria A Surge • EN61000-4-5, installation class 3, Perf Criteria A - Conducted Immunity • EN61000-4-6, 3 V, Perf Criteria A Magnetic Field • EN61000-4-8, 1 A/m, Perf Criteria A Dips & Interruptions • EN55035 , >95% 10 ms, 30% 500 ms, >95% 5000 ms, Perf Criteria A, A, B - Safety Approvals • UL62368-1, CSA C22.2 No 62368-1-14, EN 62368-1, IEC62368-1:2014, CE (Meets all applicable directives), UKCA (Meets all applicable legislation) **HDS800** ## ~~**Models and Ratings**~~ |Output Power|Output Voltage V1|Output Current|Output Current|Efficiency(2)|Model Number| |---|---|---|---|---|---| |||Min|Max||| |800 W|12.0 VDC|0.0 A|66.7 A|89%|HDS800PS12| |800 W|15.0 VDC|0.0 A|53.4 A|90%|HDS800PS15| |800 W|24.0 VDC|0.0 A|33.5 A|92%|HDS800PS24| |800 W|30.0 VDC|0.0 A|26.7 A|92%|HDS800PS30| |800 W|36.0 VDC|0.0 A|22.3 A|92%|HDS800PS36| |800 W|48.0 VDC|0.0 A|16.7 A|92%|HDS800PS48| |800 W|60.0 VDC|0.0 A|13.4 A|92%|HDS800PS60| ## ~~**Notes**~~ _1. Ripple & noise is measured with 20 MHz bandwidth and using 12”twisted pair-wire terminated with 0.1 μ F & 47 μ F capacitors in parallel._ _2. Measured with 230 VAC input and full load._ ## ~~**Mechanical Details**~~ **==> picture [426 x 245] intentionally omitted <==** **----- Start of picture text -----**<br> 1.61 (40.9)<br>— O 9.80 (249.0) O<br>+V<br>O|P |® M6 ‘<br>-V<br>lof N e) 3 x M4 (bottom side) | @<br>CN2 STATUS TRIM Penetration Depth = 4mmMax Torque = 1.27 Nm 2.91<br>LED (74.0)<br>5.00 Airflow<br>(127.0)<br>E<br>2.52 N<br>(64.0)<br>L<br>0.55 (14.0) 7.80 (198.0)<br>1.46 (37.0)<br>1.06 (26.9)<br>0.81 (20.5) 6 x M4 (Both sides)<br>Penetration Depth = 4mm 0.98 (25.0)<br>Max Torque = 1.27 Nm<br>4 Lp<br>0.45 (11.5) 8.70 (221.0) 0.32 (8.0)<br>2 1<br>24 23<br>**----- End of picture text -----**<br> CN2 Control Pin Connections Pin Functio Description Pin Function Description Pin Function Description +5V/0.5 A or +9V/0.3 Mating connector CN2: Manufacturer :JST Housing: PHDR-24VS ~~a~~ 1 VS+ Remote sense (+) 9 ENInhibit On/Off(-) 17 AUX A Standby power Contacts: SPHD-002T-P0.5 2 VO+ Positive Output 10 GND Ground 18 GND Ground Voltage (28-24 AWG) ~~esa~~ 3 VSRemote Sense ~~sR~~ (-) 11 EN+ Inhibit On/Off ~~GO~~ (+) 19 SCL I[2] C Serial Clock **Note** ~~**s** a OO~~ 4 VONegative Output Voltage 12 AUX +5V/0.5 A or +9V/0.3 A Standby power 20 SDA I[2] C Serial Data 1. All dimensions are in inches (mm). +5V/0.5 A or 2. Weight 3.85 lb (1.75 kg) ~~a~~ 5 POK Power OK ~~ee~~ 13 ACI ~~ee ed~~ I Program 21 AUX +9V/0.3 A power 3. Maintain 2” (50mm) clear space at each end. 6 GND Ground 14 GND Ground 22 GND Ground *Only usable with driver board “KIT-RS232-X” or “KIT-RS485-1” 7 PAR Parallel Operation Current Share 15 VCI V Program 23 RX* Receive ~~ToL a~~ 8 VSET ~~es~~ Aux Output Setting 16 es ~~GQ~~ GND Ground 24 TX* Transmit ## ~~**Derating Curve**~~ ## **Thermal Derating Curve** **==> picture [128 x 89] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>40<br>20<br>-10 0 10 20 30 40 50 60 70<br>Ambient Temperature (˚C)<br>Load (%)<br>**----- End of picture text -----**<br> ## **Input Derating Curve** **==> picture [142 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 100 110 120 264<br>Input Voltage (VAC)<br>Load (%)<br>**----- End of picture text -----**<br> **HDS800** ## ~~**Application Notes**~~ ## **LED Status** |LED Status|Output Status| |---|---| |Solid(Green)|DC Output OK| |Solid(Orange)|DC Output OK in remote control mode| |Slow Blink(Green)|Output Not Enabled| |Slow Blink(Orange)|Output Not Enabled in remote control mode| |Fast Blink(Red)|Over Voltage| |Solid(Red)|Over Loaded| |Slow Blink(Red)|Over Temperature| |Intermittent Blink(Red)|Fan Fail| |Short & Long Blink (Red)|AUX Standby Failure| ## **Output Voltage Programming** **==> picture [462 x 247] intentionally omitted <==** **----- Start of picture text -----**<br> Via External Voltage Via External Resistor<br>120 120<br>100 100<br>80 80<br>60 60<br>4020 4020 aee<br>0 a 0 | Pe<br>0 1 2 3 4 4.5 4.8 5 0 1 2 3 4 4.5 4.8 5<br>Programming Voltage (VDC) Resistor Value (k Ω )<br>Output Current Program<br>Via External Voltage Via External Resistor<br>120 120<br>100 ee 100 ee<br>80 te 80 ee<br>60 Pre 60 Pee<br>40 40<br>20 aE 20 aE<br>0 Pe 0 Pee<br>0 1 2 3 4 4.5 5 0 1 2 3 4 4.5 5<br>Programming Voltage (VDC) Resistor Value (k Ω)<br>Output Voltage (%) Output Voltage (%)<br>Output Current(%) Output Current (%)<br>**----- End of picture text -----**<br> ## **Remote Enable** *GND shown in the diagram (below) is referring to the GND of CN2, not the Grounding from output power (V-) **==> picture [431 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> AUX AUX AUX OFF Power OFF<br>ON Power ON<br>2KΩ EN+ SW 2KΩ EN+ 2KΩ EN+<br>AUX OFFON Power OFFPower ON AUX HL Power OFFPower ON AUX SW External DC source(Max = 9Vdc)<br>EN- EN- EN-<br>L / H<br>a = GND 4 e GND S GND & GND |<br>(A) Using internal auxilliary standby (B) Using external transistor (C) Using external voltage source<br>**----- End of picture text -----**<br> ## **External Programming Voltage Connection** **==> picture [442 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> IC=1mA IC=1mA<br>IC=1mA<br>I-sink<br>min 1mA<br>220R VC = IC x R<br>+ A/D<br>CTRL VCI/ACI - PWM CTRL VCI/ACI 0-5VDC CTRL VCI/ACI R=0-5K<br>a s<br>tear<br>Power Supply Power Supply<br>Power Supply<br>**----- End of picture text -----**<br> **HDS800** ## ~~**Application Notes**~~ ## **POK Signal** ## **OVP Setting** **==> picture [371 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> OVP Trip Point<br>POWER SUPPLY<br>AUX 200%<br>3300R 196%<br>Pok<br>Power not<br>120%<br>Power OK 114%<br>7% 100% 105%<br>GND<br>CN2 Connector % of Nominal Output Voltage<br>**----- End of picture text -----**<br> Open drain signal, low when PSU turns on Maximum sink current: 20 mA Maximum drain voltage: 40 V ## **Current Share** **==> picture [480 x 385] intentionally omitted <==** **----- Start of picture text -----**<br> Remote Sense<br>23 CN2 24<br> RX* TX*<br>AUX GND<br>SCL SDA<br>r a] FE AUX GND sl fz fe fz<br>Load<br>VCI GND<br>ACI GND<br>EN+ AUX<br>EN- GND 23 24 23 24 23 24 23 24<br> PAR VSET RX* TX* RX* TX* RX* TX* RX* TX*<br>ef POK GND TI AUX GND CT AUX GND a AUX GND TJ AUX GND<br>VS- VO-<br>Load peu)Ley) AALL 1 VS+ VO+ 2 4} SCLAUX GNDSDA ) ES SCLAUX GNDSDA 4 SCLAUX GNDSDA 4 SCLAUX GNDSDA<br>VCI GND VCI GND VCI GND VCI GND<br>ACI GND ACI GND ACI GND ACI GND<br>aSSccsodfy LfLT EN+ AUX _] CfCT EN+ AUX _] Lfa EN+ AUX _] eee LfLt EN+ AUX _]<br>EN- GND EN- GND EN- GND EN- GND<br>PAR VSET PAR VSET PAR VSET PAR VSET<br>POK GND POK GND POK GND POK GND<br>VS- VO- VS- VO- VS- VO- VS- VO-<br>SS St 4 4<br>VS+ VO+ VS+ VO+ VS+ VO+ VS+ VO+<br>1 2 1 2 1 2 1 2<br>Local Sense<br>23 RX* CN2 TX*2424 Current Sharing with Remote Sensing<br>AUX GND<br>SCL SDA<br>AUX GND<br>VCI GND 23 24 23 24 23 24 23 24<br>ACI GND RX* TX* RX* TX* RX* TX* RX* TX*<br>7 EN+ AUX [TT AUX GND _] [_T_ AUX GND [T_] AUX GND AUX GND<br>EN- GND SCL SDA SCL SDA SCL SDA SCL SDA<br>PAR VSET<br>AUX GND AUX GND AUX GND AUX GND<br>POK GND<br>Load VS- VO- VCI GND VCI GND VCI GND VCI GND<br>VS+ VO+ ACI GND ACI GND ACI GND ACI GND<br>Ls P44) | Fe 4<br>1 2 Ser EN+ AUX | Ae EN+ AUX | ES EN+ AUX . .. EN+ AUX<br>EN- GND EN- GND EN- GND EN- GND<br>Must be used if remote sense is not 4rT PAR VSET | FEa PAR VSET 4a PAR VSET PAR VSET<br>required. rT POK GND rT POK GND rT POK GND POK GND<br>VS- VO- VS- VO- VS- VO- VS- VO-<br>VS+ VO+ VS+ VO+ VS+ VO+ VS+ VO+<br>1 2 1 2 1 2 1 2<br>FS) (]) (RS<br>CN2<br>23 24 23 24 23 24 23 24<br>CN2 CN2 CN2 CN2<br>1 2 1 2 1 2 1 2<br>23 24<br>1 2<br>1 2<br>CN2<br>23 24<br>**----- End of picture text -----**<br> **==> picture [116 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 23 RX* CN2 TX*2424<br>AUX GND<br>SCL SDA<br>AUX GND<br>VCI GND<br>ACI GND<br>7 EN+ AUX<br>EN- GND<br>PAR VSET<br>POK GND<br>Load<br>VS- VO-<br>VS+ VO+<br>Ls<br>1 2<br>Must be used if remote sense is not<br>required.<br>1 2<br>CN2<br>23 24<br>**----- End of picture text -----**<br> **==> picture [176 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Current Sharing with Local Sensing<br>**----- End of picture text -----**<br> ## **Notes** In parallel operation, it is possible that only one unit will operate if the load is less than 5% of the combined rated output load. It is possible to have more than five units in parallel, contact sales for details. *Pin 23 and 24, Only usable with driver board “KIT-RS232-X” or “KIT-RS485-1” 06 Sept 2022
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →