HDS1500PS24
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 1.5 kW, 24 VDC, 62.5 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:1.5kW; Output Voltage - Output 1:24V; Output Current - Output 1:62.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (15-Jan-2018)
- Product Range: HDS1500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 1.5kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 62.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 696.1 € |
| Current stock | 10+ |
| Lead time | 30 days |
## HDS1500 Series ## 1500W **CONVECTION COOLED** ## AC-DC POWER SUPPLIES The HDS1500 series offers users both output voltage and output current programming (0– 105%) via resistance, voltage or I2C bus in a very high efficiency, high power density 1.5kW chassis mount package. Measuring just 12.32” x 2.5” x 5.0”, the HDS1500 also features active current sharing, remote on/off, remote sense and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5V at 0.5A or 9V at 0.3A. ## **Features** - High Efficiency up to 92% - High Power Density - Programmable Output Voltage (0-105%) **==> picture [162 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> Applications<br>Industrial Lasers LED Heating Robotics<br>Electronics<br>**----- End of picture text -----**<br> - Programmable Output Current (0-105%) - Parallel Operation **==> picture [53 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>**----- End of picture text -----**<br> - Fully Featured Signals & Controls 12.32” x 2.50” x 5.00” (294.5 x 63.5 x 127mm) - 3 Year Warranty ## **Models & Ratings** |Model Number<br>HDS1500PS12|Output Voltage V1<br>12.0VDC|Output Current<br>Min<br>Max<br>0.0A<br>125.0A|Output Current<br>Min<br>Max<br>0.0A<br>125.0A|Efficiency(1)<br>89%| |---|---|---|---|---| |HDS1500PS15|15.0VDC|0.0A|100.0A|90%| |HDS1500PS24|24.0VDC|0.0A|62.5A|91%| |HDS1500PS30|30.0VDC|0.0A|50.0A|92%| |HDS1500PS36|36.0VDC|0.0A|41.7A|92%| |HDS1500PS48|48.0VDC|0.0A|31.3A|92%| |HDS1500PS60|60.0VDC|0.0A|25.0A|93%| Notes: 1. Measured with 230VAC input and full load. AC-DC POWER SUPPLIES ## HDS1500 Series ## **Input** **==> picture [540 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage|90||264|VAC|See derating curve| |Input Frequency|47||63|Hz|| |Power Factor||0.99/0.98|||115/230VAC Full load| |Input Current|||18/9|A|115/230VAC| |Inrush Current|||30/60|A|115/230VAC| |Earth Leakage Current|||1.0|mA|264VAC/60Hz| |Input Protection|F20 A/250 V internal fuse||||| ## **Output** **==> picture [540 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|12||60|VDC|See Models & Ratings table| |Output Trim||±5.0||%|By potentionmeter| |Output Voltage Program|0||105|%|Of rated output| |Output Current Program|0||105|%|Of rated output| |Voltage Tolerance(1)|||±2|%|Of rated output voltage(1)| |Current Tolerance(1)|||±3|%|Of rated output current(1)| |Minimum Load|No minimum load required||||| |Start Up Delay|||1|s|| |Start Up Rise Time|||120|ms|At full load| |Hold Up Time|8|||ms|| |Line Regulation|||±1|%|| |Load Regulation|||±1|%|V1, 0-100% load| ||||±3|%|5V standby, 0-100% load| |Transient Response|||1|%|For a 25% step load change| |Ripple & Noise|||1|% pk-pk|1.25% for 12V model. Measured with 20 MHz bandwidth and using<br>12” twisted pair wire terminated with 0.1μF ceramic capacitor and<br>47μF electrolytic.| |Overvoltage Protection|Tracks output voltage. See application notes, recycle AC to reset||||| |Overtemperature Protection|Primary and secondary heatsinks monitored. Output shuts down, auto recovers||||| |Overload Protection||105||%|Rated power, constant current| |Short Circuit Protection|Auto recovery||||| |Temperature Coeffcient||±0.02||%/°C|0-50°C| |Remote Sense|Compensates for 0.5V max voltage drop If remote sense is not required, local sense must be used||||| |Enable|Output must be enabled. See application notes, power supply is shipped with enable links ftted||||| |Current Share|5 supplies can share within 5%||||| |Standby Output|5V at 0.5A, present whenever AC is applied (9V at 0.3A, user selectable, by connecting ‘VSET’, Pin 8 of CN2 to ‘GND’)||||| ## **Notes:** 1. Tolerance includes setup time tolerance, line regulation and load regulation. 2 AC-DC POWER SUPPLIES ## HDS1500 Series ## **Output** Output Voltage Programming Via External Voltage ## Via External Resistor **==> picture [206 x 280] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>rr ane<br>40<br>a are<br>200 |PePoepo<br>0 1 2 3 4 4.5 4.8 5<br>Resistor Value (kΩ)<br>Via External Resistor<br>120<br>100<br>80<br>60<br>rr are<br>40<br>a ae<br>20 Poe<br>0 |Pepo<br>0 1 2 3 4 4.5 4.8 5<br>Resistor Value (kΩ)<br>Output Voltage (%)<br>Output Current (%)<br>**----- End of picture text -----**<br> ||||||||||||||120|120|||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |0<br>20<br>40<br>60<br>80<br>100<br>120<br>Output Voltage (%)||~~ea~~||||||||||Output Voltage (%)|0<br>200<br>40<br>60<br>80<br>100<br>120||~~PePoepo~~<br>~~|PePoepo~~<br>~~rr~~<br>~~ane~~<br>~~a~~<br>~~are~~<br>~~Poepo~~<br>~~po~~||||| ||0||1|2|3||4|4.5 4.8|||5||||0<br>1<br>2<br>3<br>4<br>4.5 4.8||||5| |||||Programming Voltage (VDC)||Programming Voltage (VDC)|||||||||Resistor Value (kΩ)||||| |Output Current Programming|Output Current Programming||||||||||||||||||| |Via External Voltage||||||||||||Via External Resistor|||||||| |0<br>20<br>40<br>60<br>80<br>100<br>120<br>Output Current (%)|~~ea~~|||||||||||Output Current (%)||0<br>20<br>40<br>60<br>80<br>100<br>120|~~Pepo~~<br>~~|Pepo~~<br>~~rr~~<br>~~are~~<br>~~a~~<br>~~ae~~<br>~~Poe~~<br>~~po~~||||| ||0||1|2|3||4|4.5 4.8|||5||||0<br>1<br>2<br>3<br>4<br>4.5 4.8||||5| ||||Programming Voltage (VDC)||||||||||||Resistor Value (kΩ)||||| |||**General**|||||||||||||||||| |Characteristic<br>Efficiency||||Minimum<br>89|||Typical||Maximum<br>93|||Units<br>%||Notes & Conditions<br>230VAC Full load|||||| |Isolation: Input to Output|Isolation: Input to Output||||3000|||||||VAC|||||||| |Input to Ground|Input to Ground||||1500|||||||VAC|||||||| |Output to Ground|||||500|||||||VAC|||||||| ||||||||65|||||||PFC converter|||||| |Switching Frequency||||||||||||kHz|||||||| ||||||40||||||200|||PWM, variable|||||| |Power Density|||||||||||9.7|W/in3|||||||| |Signals and Controls||||||||||||||Enable, Current Share, V Program, I Program, 5 V Standby, Power OK|||||| |Mean Time Between Failure|||||||115|||||khrs||MIL-HDBK-217F, Notice 2 25°C GB|||||| |Weight|||||||5.7 (2.6)|||||lb (kg)|||||||| Output Current Programming ## Via External Voltage Specifications subject to change without notice. 3 AC-DC POWER SUPPLIES ## HDS1500 Series ## **Environmental** |Characteristic|Minimum|Typical<br>Maximum|Units|Notes & Conditions| |---|---|---|---|---| |Operating Temperature|-25|+60|°C|Derate linearly from 100% load at 50°C to 60% load at 60°C| |Storage Temperature|-40|+85|°C|| |Cooling|Internal fan fitted, speed increases with load and internal temperature|||| |Humidity|20|90|%RH|| |Vibration||2|g|10-500 Hz, 10 min/cycle, 60 min period for each axis, compliant to<br>IEC68-2-6, IEC 68-2-64| Derating Curve Thermal Derating Curve **==> picture [537 x 537] intentionally omitted <==** **----- Start of picture text -----**<br> Thermal Derating Curve Input Derating Curve<br>100<br>100<br>90<br>8 0<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>7<br>-10 0 10 20 30 40 50 60 70 90 100 110 120 264<br>Ambient Temperature (˚C) Input Voltage (VAC)<br>External Programming Voltage Connection<br>IC=1mA IC=1mA IC=1mA<br>I-sink<br>min 1mA<br>+ A/D 220R VC = IC x R<br>- PWM<br>CTRL VCI/ACI CTRL VCI/ACI 0-5VDC CTRL VCI/ACI R=0-5K<br>Har<br>Power Supply Power Supply Power Supply<br>Hn Ah<br>4<br>) %<br>ad (<br>L o Load (%)<br>**----- End of picture text -----**<br> External Programming Voltage Connection AC-DC POWER SUPPLIES ## HDS1500 Series ## **Signals & Controls** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> LED Status Output Status<br>**----- End of picture text -----**<br> |Solid (Green)|DC Output OK| |---|---| |Solid (Orange)|DC Output OK in remote control mode| |Slow Blink (Green)|Output Not Enabled| |Fast Blink (Red)|Over Voltage| |Solid (Red)|Over Loaded| |Slow Blink (Red)|Over Temperature| |Intermittent Blink (Red)|Fan Fail| |Short & Long Blink (Red)|AUX Standby Failure| ## Remote Enable **==> picture [487 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 5 V SB 5 V SB 5 V SB OFF Power OFF<br>ON Power ON<br>2KΩ EN+ SW 2KΩ EN+ 2KΩ EN+<br>L Power OFF SW<br>5V OFFON Power OFFPower ON 5V H Power ON 5V 5V<br>EN- EN- EN-<br>L / H<br>GND GND GND GND<br>(A) Using internal 5 V standby (B) Using external transistor (C) Using external voltage source<br>**----- End of picture text -----**<br> *GND shown in above diagram is referring to the GND of CN2, not the grounding from output power (NEG (-)) ## **EMC: Emissions** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Notes & Conditions<br>**----- End of picture text -----**<br> |Conducted|EN55032|Class A|| |---|---|---|---| |Radiated|EN55032|Class A|| |Harmonic Currents|EN61000-3-2|Class A|| |~~Volt~~age Flicker|EN61000-3-3||| Specifications subject to change without notice26 Jan 2022 . 5 AC-DC POWER SUPPLIES ## HDS1500 Series ## **EMC: Immunity** |Phenomenon<br>ESD Immunity|Standard<br>EN61000-4-2|Test Level<br>2/3|Criteria<br>A|Notes & Conditions<br>±4kV contact, ±8kV air discharge| |---|---|---|---|---| |Radiated|EN61000-4-3|3|A|| |EFT/Burst|EN61000-4-4|3|A|| |Surges|EN61000-4-5|Installation class 3|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic Field|EN61000-4-8|3|A|| |Dips and Interruptions|EN55035|Dip 30% 500ms|A/B|High line/Low line| |||Int >95% 10ms|A|| |||Int >95% 5000ms|B|| ## **Safety Approvals** |Certification|Standard|Notes & Conditions| |---|---|---| |CB|IEC62368-1|| |UL|UL62368-1, CSA C22.2 No 62368-1-14|Audio/Video, Information and Communication Technology Equipment| |EN|EN62368-1|| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| ## **Application Notes** ## OVP Setting **==> picture [467 x 206] intentionally omitted <==** **----- Start of picture text -----**<br> POK Signal<br>POWER SUPPLY<br>AUX OVP Trip Point<br>3300R 200%<br>196%<br>Pok<br>Power not<br>Power OK 120%<br>114%<br>GND<br>CN2 Connector [ I N 7% 100% 105%<br>% of Nominal Output Voltage<br>Open drain signal, low when PSU turns on<br>Maximum sink current: 20mA<br>Maximum drain voltage: 40V<br>**----- End of picture text -----**<br> 6 **AC-DC POWER SUPPLIES** ## HDS1 ~~50~~ 0 Series ## **Application NotesGeneral** Remote Sense **==> picture [146 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>2 1 2 CN2 1<br>VO+ VS +<br>23 VO - VS -<br>GND POK<br>VS ET PAR<br>+ - GND EN-<br>AUX EN+<br>GND ACI<br>GND VCI<br>GND AUX<br>S DA S CL<br>GND AUX<br>Load TX* RX*<br>24 23<br>**----- End of picture text -----**<br> Current Share with Re ~~mote Sensing~~ **==> picture [265 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 + 2 1 + 2 1 + 2 1 +<br>24 23 24 23 24 23 24 23<br>VO+ VS+ VO+ VS+ VO+ VS+ VO+ VS+<br>VO- VS- VO- VS- VO- VS- VO- VS-<br>GND POK GND POK GND POK GND POK<br>VSET PAR VSET PAR VSET PAR VSET PAR<br>GND EN- GND EN- GND EN- GND EN-<br>AUX EN+ AUX EN+ AUX EN+ AUX EN+<br>GND ACI GND ACI GND ACI GND ACI<br>GND VCI GND VCI GND VCI GND VCI<br>GND AUX GND AUX GND AUX GND AUX<br>SDA SCL SDA SCL SDA SCL SDA SCL<br>GND AUX GND AUX GND AUX GND AUX<br>TX* RX* TX* RX* TX* RX* TX* RX*<br>24 23 24 23 24 23 24 23<br>**----- End of picture text -----**<br> Local Sense ## Curre ~~nt Share with Local Sensing~~ **==> picture [481 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> CN2 2 + 2 1 + 2 1 + 2 1 +<br>2 + 2 1 23 24 23 24 23 24 23<br>VO+ VS +<br>23 VO - VS -<br>GND POK<br>VS ET PAR<br>+ - GND EN-<br>AUX EN+<br>Load GND ACI VO+ VS+ VO+ VS+ VO+ VS+ VO+ VS+<br>GND VCI VO- VS- VO- VS- VO- VS- VO- VS-<br>GND POK GND POK GND POK GND POK<br>GND AUX VSET PAR VSET PAR VSET PAR VSET PAR<br>S DA S CL GND EN- GND EN- GND EN- GND EN-<br>GND AUX AUX EN+ AUX EN+ AUX EN+ AUX EN+<br>GND ACI GND ACI GND ACI GND ACI<br>TX* RX* GND VCI GND VCI GND VCI GND VCI<br>24 23 GND AUX GND AUX GND AUX GND AUX<br>SDA SCL SDA SCL SDA SCL SDA SCL<br>GND AUX GND AUX GND AUX GND AUX<br>Must be used if remote sense is not required. TX* RX* TX* RX* TX* RX* TX* RX*<br>24 23 24 23 24 23 24 23<br>**----- End of picture text -----**<br> Must be used if remote sense is not required. Notes: 1. In parallel operation, it is possible that only one unit will operate if the load is less than 5% of the combined rated output load. It is possible to have more than five units in parallel, contact sales for details. - *Pin 23 and 24, Only usable with driver board “KIT-RS232-X” or “KIT-RS485-1” 2. Maximum output current should not exceed 90% of the combined rated current of the units in parallel. Specifications subject to change without notice26 Jan 2022 . 7 AC-DC POWER SUPPLIES ## HDS1500 Series ## **Mechanical Details** **==> picture [438 x 292] intentionally omitted <==** **----- Start of picture text -----**<br> Torque: 2.5 ±2Kgf.cm (2.5±0.2Nm)<br>AIR FLOW<br>12.36 (313.85)<br>8-M4 (both sides) L=0.12 (3.0) max<br>11.02 (280.0)<br>1.38<br>9.33 (237.0) 5.0 (127.0)<br>(35.0)<br>0.55<br>(14.0) 2.5<br>(63.5)<br>1.34 (34.0)<br>0.59 (15.0) 9.84 (250.0)<br>3.86<br>(98.0)<br>0.57<br>(14.5) 4-M4 L=0.12 (3.0) max<br>**----- End of picture text -----**<br> **==> picture [500 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> CN2 Control Pin Connections<br>Pin Function Description Pin Function Description Pin Function Description<br>**----- End of picture text -----**<br> |CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons|CN2 Control Pin Connectons| |---|---|---|---|---|---|---|---|---| |Pin|Functon|Descripton|Pin|Functon|Descripton|Pin|Funct|on<br>Descripton| |||||||||| |1|VS+|Remote Sense (+)|9|EN-|Inhibit On/Off (-)|17|AUX|+5V/0.5 A or +9V/0.3 A<br>Standby power| |2|VO+|Positive Output Voltag|e<br>10|GND|Ground|18|GND|Ground| |3|VS-|Remote Sense (-)|11|EN+|Inhibit On/Off (+)|19|SCL|I2C Serial Clock| |4|VO-|Negative Output Voltag|e<br>12|AUX|+5V/0.5 A or +9V/0.<br>Standby power|3 A<br>20|SDA|I2C Serial Data| |5|POK|Power OK|13|ACI|I Program|21|AUX|+5V/0.5 A or +9V/0.3 A<br>Auxiliary power| |6|GND|Ground|14|GND|Ground|22|GND|Ground| |7|PAR|Parallel Operation<br>Current Share|15|VCI|V Program|23|RX*|Receive| |8|VSET|AUX Output Setting|16|GND|Ground|24|TX*|Transmit| ## **Notes:** 1. All dimensions are in inches (mm). 2. Weight 5.7lb (2.6kg) 3. Maintain 2” (50mm) clear space at each end. SPHD-002T-P0.5 contacts (28-24 AWG) 5. Torque of mounting M4 screw: 1.27Nm (13.0kgf.cm) - *Only usable with driver board “KIT-RS232-X” or “KIT-RS485-1” 4. Mating connector CN2: Manufacturer: JST Housing: PHDR-24VS, Contacts: **==> picture [148 x 49] intentionally omitted <==** 8 02 April 2025
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →