Image not available
Illustrative purposes only
HDR-60-5
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 32.5 W, 5 VDC, 6.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:32.5W; Output Voltage - Output 1:5V; Output Current - Output 1:6.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Out
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HDR-60 Series
- No. of Outputs: 1 Output
- Output Power Max: 32.5W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 6.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 25.32 € |
| Current stock | 50+ |
| Lead time | 30 days |
**- HDR 60 series** 60W Ultra Slim Step Shape DIN Rail **==> picture [143 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>UL508 UL60950-1 EN61558www.ID 2000000000tuv.com IEC60950-1<br>**----- End of picture text -----**<br> ## **** Ultra slim design with 52.5mm( - ‧ - ‧ - ‧ass LPS (Limited power source) ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ / - ‧ooling by free air convection (working temperature:-30~+70°C) - ‧DIN rail TS-35/7.5 or 15 mountable - ‧ED indicator for power on - ‧ ## ■ **** C Cc ■ **** ~~T~~ **** ~~E~~ **** _File Name:HDR-60-SPEC 2016-10-28_ 60W Ultra Slim Step Shape DIN Rail ## **- HDR 60 series** ## **SPECIFICATION** ||**HDR-60-5**<br>**HDR-60-12**<br>**HDR-60-15**<br>**HDR-60-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD Note.4**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>6.5A<br>4.5A<br>4A<br>2.5A<br>0 ~6.5A<br>0 ~ 4.5A<br>0 ~ 4A<br>0 ~ 2.5A<br>54W<br>60W<br>60W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>13.5 ~ 18V<br>150mVp-p<br>21.6 ~ 29V<br>�2.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>10.8 ~ 13.8V<br>5.0 ~ 5.5V<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available )<br>47 ~ 63Hz<br>85%<br>88%<br>89%<br>90%<br>1.2A/115VAC 0.8A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>105 ~ 160% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>5.75 ~ 6.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14.2 ~ 16.2V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>-30 ~ +70�(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85�, 10 ~ 95% RH non-condensing<br>�0.03%/�(0 ~ 50�) RH non-condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>927.6K hrs min. MIL-HDBK-217F (25�)<br>52.5*90*54.5mm (W*H*D)<br>190g;60pcs/12.4Kg/0.97CUFT<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25�/ 70% RH<br>**HDR-60-48**<br>48V<br>1.25A<br>0 ~ 1.25A<br>60W<br>240mVp-p<br>43.2 ~ 55.2V<br>�1.0%<br>�1.0%<br>�1.0%<br>91%<br>56.5 ~ 64.8V<br>32.5W<br>UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 a<br>EN50178,<br>pproved; Design refer to<br>TUV EN60950-1<br>℃<br><br><br><br><br><br><br><br>EN55024, EN55035, EN61000-6-2, EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32)<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32)<br>**OPERATING ALTITUDE**<br>2000 meters<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|**HDR-60-5**<br>**HDR-60-12**<br>**HDR-60-15**<br>**HDR-60-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD Note.4**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>6.5A<br>4.5A<br>4A<br>2.5A<br>0 ~6.5A<br>0 ~ 4.5A<br>0 ~ 4A<br>0 ~ 2.5A<br>54W<br>60W<br>60W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>13.5 ~ 18V<br>150mVp-p<br>21.6 ~ 29V<br>�2.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>10.8 ~ 13.8V<br>5.0 ~ 5.5V<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available )<br>47 ~ 63Hz<br>85%<br>88%<br>89%<br>90%<br>1.2A/115VAC 0.8A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>105 ~ 160% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>5.75 ~ 6.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14.2 ~ 16.2V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>-30 ~ +70�(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85�, 10 ~ 95% RH non-condensing<br>�0.03%/�(0 ~ 50�) RH non-condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>927.6K hrs min. MIL-HDBK-217F (25�)<br>52.5*90*54.5mm (W*H*D)<br>190g;60pcs/12.4Kg/0.97CUFT<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25�/ 70% RH<br>**HDR-60-48**<br>48V<br>1.25A<br>0 ~ 1.25A<br>60W<br>240mVp-p<br>43.2 ~ 55.2V<br>�1.0%<br>�1.0%<br>�1.0%<br>91%<br>56.5 ~ 64.8V<br>32.5W<br>UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 a<br>EN50178,<br>pproved; Design refer to<br>TUV EN60950-1<br>℃<br><br><br><br><br><br><br><br>EN55024, EN55035, EN61000-6-2, EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32)<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32)<br>**OPERATING ALTITUDE**<br>2000 meters<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|**HDR-60-5**|**HDR-60-12**|**HDR-60-12**|**HDR-60-15**|**HDR-60-24**|**HDR-60-24**|**HDR-60-48**| |---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|5V|12V||15V|24V||48V| |||**RATED CURRENT**|6.5A|4.5A||4A|2.5A||1.25A| |||**CURRENT RANGE**|0 ~6.5A|0 ~ 4.5A||0 ~ 4A|0 ~ 2.5A||0 ~ 1.25A| |||**RATED POWER**|32.5W|54W||60W|60W||60W| |||**RIPPLE & NOISE (max.)Note.2**|80mVp-p|120mVp-p||120mVp-p|150mVp-p||240mVp-p| |||**VOLTAGE ADJ. RANGE**|5.0 ~ 5.5V|10.8 ~ 13.8V||13.5 ~ 18V|21.6 ~ 29V||43.2 ~ 55.2V| |||**VOLTAGE TOLERANCENote.3**|�2.0%|�1.0%||�1.0%|�1.0%||�1.0%| |||**LINE REGULATION**|�1.0%|�1.0%||�1.0%|�1.0%||�1.0%| |||**LOAD REGULATION**|�1.0%|�1.0%||�1.0%|�1.0%||�1.0%| |||**SETUP, RISE TIME**|500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load||||||| |||**HOLD UP TIME (Typ.)**|30ms/230VAC 12ms/115VAC at full load||||||| |||**VOLTAGE RANGE**|85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available )||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz||||||| |||**EFFICIENCY (Typ.)**|85%|88%||89%|90%||91%| |||**AC CURRENT (Typ.)**|1.2A/115VAC 0.8A/230VAC||||||| |||**INRUSH CURRENT (Typ.)**|COLD START 30A/115VAC 60A/230VAC||||||| |||**OVERLOAD Note.4**|105 ~ 160% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed||||||| |||**OVER VOLTAGE**|5.75 ~ 6.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14.2 ~ 16.2V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>56.5 ~ 64.8V||||||| |||**WORKING TEMP.**|-30 ~ +70�(Refer to "Derating Curve")||||||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85�, 10 ~ 95% RH non-condensing||||||| |||**TEMP. COEFFICIENT**|�0.03%/�(0 ~ 50�) RH non-condensing||||||| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||||| |||**OPERATING ALTITUDE**|2000 meters||||||| |||**SAFETY STANDARDS**|UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 a<br>EN50178,<br>pproved; Design refer to<br>TUV EN60950-1||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC||||||| |||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25�/ 70% RH||||||| |||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**||**Standard**|||**Test Level / Note**|| ||||Conducted||EN55032(CISPR32)|||Class B|| ||||Radiated||EN55032(CISPR32)|||Class B|| ||||Harmonic Current||EN61000-3-2|||Class A|| ||||Voltage Flicker||EN61000-3-3|||-------|| ||||EN55024, EN55035, EN61000-6-2, EN61204-3||||||| ||||**Parameter**||**Standard**|||**Test Level /Note**|| ||||ESD||EN61000-4-2|||Level 3, 8KV air; Level 2, 4KV contact, criteria A|| ||||Radiated Susceptibility||EN61000-4-3|||Level 3, criteria A|| ||||EFT/Burest||EN61000-4-4|||Level 3, criteria A|| ||||Surge||EN61000-4-5|||Level 4,2KV/L-N, criteria A|| ||||Conducted||EN61000-4-6|||Level 3, criteria A|| ||||Magnetic Field||EN61000-4-8|||Level 4, criteria A|| ||||Voltage Dips and interruptions||EN61000-4-11|||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| ||||927.6K hrs min. MIL-HDBK-217F (25�)||||||| |||**DIMENSION**|52.5*90*54.5mm (W*H*D)||||||| |||**PACKING**<br>190g;60pcs/12.4Kg/0.97CUFT<br>℃<br><br><br><br><br><br><br>|||||||| _File Name:HDR-60-SPEC 2016-10-28_ **- HDR 60 series** ## 60W Ultra Slim Step Shape DIN Rail ## **Block Diagram** **==> picture [484 x 457] intentionally omitted <==** **----- Start of picture text -----**<br> RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>DETECTION<br>CIRCUIT<br>PWM<br>O.L.P.<br>CONTROL<br>O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80<br>80<br>60 70<br>50<br>60<br>40<br>50<br>20 40<br>-30 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 277<br>(available)<br>AMBIENT TEMPERATURE ( � ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HDR-60-SPEC 2016-10-28_ **- HDR 60 series** 60W Ultra Slim Step Shape DIN Rail ## **Mechanical Specification** (Unit: mm , tolerance ± 0.5mm) **==> picture [412 x 342] intentionally omitted <==** **----- Start of picture text -----**<br> 58.4<br>54.5<br>52.5<br>1 2 3 4<br>5 6<br>90 63.65 45.15<br>35<br>**----- End of picture text -----**<br> ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin No. Assignment |Pin No|.<br>P<br>Assignment|in No.<br>Assignment| |---|---|---| |1,2|-V|5<br>AC/L| |3,4|+V|6<br>AC/N| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HDR-60-SPEC 2016-10-28_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →