Image not available
Illustrative purposes only
HDR-60-24
AC/DC DIN Rail Power Supply (PSU), Ultra Slim, ITE, 1 Output, 60 W, 24 VDC, 2.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:60W; Output Voltage - Output 1:24V; Output Current - Output 1:2.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltag
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HDR-60 Series
- No. of Outputs: 1 Output
- Output Power Max: 60W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 20.71 € |
| Current stock | 1000+ |
| Lead time | 30 days |
- - 60W Ultra Slim Step Shape DIN Rail **HDR 60 series** ~~OTe~~ **User’s Manual** ~~aera pREs~~ - ' Se ~~iO]ate~~ - BauarSicherheitbeegelodwacmat geprufto ges g - LPS -@s **UL508** ‘Ads **UL62368 1- BS EN/EN61558www.ID 2000000000tuv.com** ~~S~~ **TPTC004** fil **AS/NZS60950-1** & CB **IEC62368-1 IS13252** THOMAS SAMUEL THOMAS SAMUEL UK Qs] (tt) (Aa) (Ae -$3] | ¥ **(NOTE 6)** ■ Features ■ Applications , Ultra slim design with 52.5mm( 3SU) width * Household control system * Universal input 85~264VAC(277VAC operational) * Building automation * No load power consumption<0.3W * Industrial control system * Isolation class Ⅱ * Factory automation *?P ass LPS (Limited power source) * Electro-mechanical apparatus * DC output voltage adjustable * Protections : Short circuit / Overload Over voltage -_ ooling by free air convection (working temperature:-30~+70°C) ■ GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx ~~a~~ - DIN rail TS-35/7.5 or 15 mountable - eL ED indicator for power on * 3 years warranty ■ Description ℃ ℃ **==> picture [13 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:HDR-60-SPEC 2024-10-30_ **- HDR 60 series** 60W Ultra Slim Step Shape DIN Rail ## **SPECIFICATION** ||**HDR-60-5**<br>**HDR-60-12**<br>**HDR-60-15**<br>**HDR-60-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>6 5. A<br>4.5A<br>4A<br>2.5A<br>0 ~<br>A<br>.6 5<br>0 ~ 4.5A<br>0 ~ 4A<br>0 ~ 2.5A<br>54W<br>60W<br>60W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>13.5 ~ 18V<br>150mVp-p<br>21.6 ~ 29V<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>10.8 ~ 1 . V<br>3 8<br>5 0<br>5 5<br>. ~ . V<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 2 VAC (<br>) 120 ~ 3 VDC (<br>)<br>64<br>277VAC operational<br>70<br>390VDC operational<br>47 ~ 63Hz<br>8 %<br>5<br>88%<br>89%<br>90%<br>1.2A/115VAC 0.8A/230VAC<br>COLD START 30A/115VAC 0A/230VAC<br>6<br>105 ~ 160% rated output power<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>5 75<br>6 75<br>. ~ . V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14 2<br>6 2<br>. ~ 1 . V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95%<br>-<br>℃<br>RH non condensing<br>±0.03%/<br>(0 ~ 50<br>)<br>-<br>℃<br>℃RH non condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>52.5*90*5 . mm (W*H*D)<br>4 5<br>190g;60pcs/13Kg/0.91CUFT<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note )4**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P: KVAC<br>4<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**HDR-60-48**<br>48V<br>1.25A<br>0 ~ 1.25A<br>60W<br>240mVp-p<br>43.2 ~ 55.2V<br>±1.0%<br>±1.0%<br>±1.0%<br>91%<br>5 . ~ 6 . V<br>6 5<br>4 8<br>32 5W<br>.<br>UL62368-1, UL508, TUV BS EN/EN61558-2-16<br>, IEC62368-1,<br>, BSMI CNS15598-1,<br>,BS EN/EN61558-1<br>EAC TP TC 004<br>BIS IS13252(Part1): 2010/IEC 60950-1:2005(NOTE )6 a<br>BS EN/<br>pproved; Design refer to<br>EN62368-1<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>6. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:<br>BS EN/<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2,<br>EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032(CISPR32), CNS15936<br>BS EN/EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>BS EN/EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>BS EN/EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>BS EN/EN55032(CISPR32), CNS15936<br>**OPERATING ALTITUDE**<br>2000 meters<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>**OVER VOLTAGE CATEGORY**<br>According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������<br>3524.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 927.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**HDR-60-5**<br>**HDR-60-12**<br>**HDR-60-15**<br>**HDR-60-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>6 5. A<br>4.5A<br>4A<br>2.5A<br>0 ~<br>A<br>.6 5<br>0 ~ 4.5A<br>0 ~ 4A<br>0 ~ 2.5A<br>54W<br>60W<br>60W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>13.5 ~ 18V<br>150mVp-p<br>21.6 ~ 29V<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>10.8 ~ 1 . V<br>3 8<br>5 0<br>5 5<br>. ~ . V<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 2 VAC (<br>) 120 ~ 3 VDC (<br>)<br>64<br>277VAC operational<br>70<br>390VDC operational<br>47 ~ 63Hz<br>8 %<br>5<br>88%<br>89%<br>90%<br>1.2A/115VAC 0.8A/230VAC<br>COLD START 30A/115VAC 0A/230VAC<br>6<br>105 ~ 160% rated output power<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>5 75<br>6 75<br>. ~ . V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14 2<br>6 2<br>. ~ 1 . V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95%<br>-<br>℃<br>RH non condensing<br>±0.03%/<br>(0 ~ 50<br>)<br>-<br>℃<br>℃RH non condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>52.5*90*5 . mm (W*H*D)<br>4 5<br>190g;60pcs/13Kg/0.91CUFT<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note )4**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P: KVAC<br>4<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**HDR-60-48**<br>48V<br>1.25A<br>0 ~ 1.25A<br>60W<br>240mVp-p<br>43.2 ~ 55.2V<br>±1.0%<br>±1.0%<br>±1.0%<br>91%<br>5 . ~ 6 . V<br>6 5<br>4 8<br>32 5W<br>.<br>UL62368-1, UL508, TUV BS EN/EN61558-2-16<br>, IEC62368-1,<br>, BSMI CNS15598-1,<br>,BS EN/EN61558-1<br>EAC TP TC 004<br>BIS IS13252(Part1): 2010/IEC 60950-1:2005(NOTE )6 a<br>BS EN/<br>pproved; Design refer to<br>EN62368-1<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>6. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:<br>BS EN/<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2,<br>EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032(CISPR32), CNS15936<br>BS EN/EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>BS EN/EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>BS EN/EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>BS EN/EN55032(CISPR32), CNS15936<br>**OPERATING ALTITUDE**<br>2000 meters<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>**OVER VOLTAGE CATEGORY**<br>According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������<br>3524.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 927.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**HDR-60-5**|**HDR-60-12**|**HDR-60-12**|**HDR-60-15**|**HDR-60-24**|**HDR-60-24**|**HDR-60-48**| |---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|5V|12V||15V|24V||48V| |||**RATED CURRENT**|6 5. A|4.5A||4A|2.5A||1.25A| |||**CURRENT RANGE**|0 ~<br>A<br>.6 5|0 ~ 4.5A||0 ~ 4A|0 ~ 2.5A||0 ~ 1.25A| |||**RATED POWER**|32 5W<br>.|54W||60W|60W||60W| |||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|120mVp-p||120mVp-p|150mVp-p||240mVp-p| |||**VOLTAGE ADJ. RANGE**|5 0<br>5 5<br>. ~ . V|10.8 ~ 1 . V<br>3 8||13.5 ~ 18V|21.6 ~ 29V||43.2 ~ 55.2V| |||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**LINE REGULATION**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**LOAD REGULATION**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**SETUP, RISE TIME**|500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load||||||| |||**HOLD UP TIME (Typ.)**|30ms/230VAC 12ms/115VAC at full load||||||| |||**VOLTAGE RANGE**|85 ~ 2 VAC (<br>) 120 ~ 3 VDC (<br>)<br>64<br>277VAC operational<br>70<br>390VDC operational||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz||||||| |||**EFFICIENCY (Typ.)**|8 %<br>5|88%||89%|90%||91%| |||**AC CURRENT (Typ.)**|1.2A/115VAC 0.8A/230VAC||||||| |||**INRUSH CURRENT (Typ.)**|COLD START 30A/115VAC 0A/230VAC<br>6||||||| |||**OVERLOAD**|105 ~ 160% rated output power<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������||||||| |||**OVER VOLTAGE**|5 75<br>6 75<br>. ~ . V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>14 2<br>6 2<br>. ~ 1 . V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>5 . ~ 6 . V<br>6 5<br>4 8||||||| |||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃||||||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95%<br>-<br>℃<br>RH non condensing||||||| |||**TEMP. COEFFICIENT**|±0.03%/<br>(0 ~ 50<br>)<br>-<br>℃<br>℃RH non condensing||||||| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||||| |||**OPERATING ALTITUDE**|2000 meters||||||| |||**OVER VOLTAGE CATEGORY**|According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ||||||| |||**SAFETY STANDARDS**|UL62368-1, UL508, TUV BS EN/EN61558-2-16<br>, IEC62368-1,<br>, BSMI CNS15598-1,<br>,BS EN/EN61558-1<br>EAC TP TC 004<br>BIS IS13252(Part1): 2010/IEC 60950-1:2005(NOTE )6 a<br>BS EN/<br>pproved; Design refer to<br>EN62368-1||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P: KVAC<br>4||||||| |||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||| ||||**Parameter**||**Standard**|||**Test Level / Note**|| ||||Conducted||BS EN/EN55032(CISPR32), CNS15936|||Class B|| ||||Radiated||BS EN/EN55032(CISPR32), CNS15936|||Class B|| ||||Harmonic Current||BS EN/EN61000-3-2|||Class A|| ||||Voltage Flicker||BS EN/EN61000-3-3|||-------|| ||||BS EN/<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2,<br>EN61204-3||||||| ||||**Parameter**||**Standard**|||**Test Level /Note**|| ||||ESD||BS EN/EN61000-4-2|||Level 3, 8KV air; Level 2, 4KV contact, criteria A|| ||||Radiated Susceptibility||BS EN/EN61000-4-3|||Level 3, criteria A|| ||||EFT/Burest||BS EN/EN61000-4-4|||Level 3, criteria A|| ||||Surge||BS EN/EN61000-4-5|||Level 4,2KV/L-N, criteria A|| ||||Conducted||BS EN/EN61000-4-6|||Level 3, criteria A|| ||||Magnetic Field||BS EN/EN61000-4-8|||Level 4, criteria A|| ||||Voltage Dips and interruptions||BS EN/EN61000-4-11|||><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>>|| |||**MTBF**|3524.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 927.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| |||**DIMENSION**|52.5*90*5 . mm (W*H*D)<br>4 5||||||| |||**PACKING**|190g;60pcs/13Kg/0.91CUFT||||||| |||1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>6. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:|||||||| _File Name:HDR-60-SPEC 2024-10-30_ **- HDR 60 series** ## 60W Ultra Slim Step Shape DIN Rail ## **Block Diagram** **==> picture [487 x 456] intentionally omitted <==** **----- Start of picture text -----**<br> RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>DETECTION<br>CIRCUIT<br>PWM<br>O.L.P.<br>CONTROL<br>O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80<br>80<br>60 70<br>50<br>60<br>40<br>50<br>20 40<br>-30 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 277<br>(operational)<br>AMBIENT TEMPERATURE ( ? ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HDR-60-SPEC 2024-10-30_ **- HDR 60 series** 60W Ultra Slim Step Shape DIN Rail ## **Mechanical Specification** (Unit: mm , tolerance ± 0.5mm) **==> picture [365 x 264] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.HDR-60<br>58.4<br>54.5<br>52.5<br>1 2 3 4<br>5 6<br>.3 65<br>90 6 45.15<br>**----- End of picture text -----**<br> **==> picture [7 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 35<br>**----- End of picture text -----**<br> ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin No. Assignment |Pin No|.<br>Pi<br>Assignment|n No.<br>Assignment| |---|---|---| |1,2|-V|5<br>AC/L| |3,4|+V|6<br>AC/N| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HDR-60-SPEC 2024-10-30_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →