Image not available
Illustrative purposes only
HDR-15-12
AC/DC DIN Rail Power Supply (PSU), Ultra Slim, ITE, 1 Output, 15 W, 12 VDC, 1.25 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:15W; Output Voltage - Output 1:12V; Output Current - Output 1:1.25A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HDR-15 Series
- No. of Outputs: 1 Output
- Output Power Max: 15W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 15.07 € |
| Current stock | 500+ |
| Lead time | 30 days |
**- HDR 15 series** 15W Ultra Slim Step Shape DIN Rail **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g LPS[@«.Wu4] ©» **UL508 UL62368 1-** Wu ~~ZS~~ **BS EN/EN61558** ~~[)]~~ **www.ID 2000000000tuv.com** | ~~S~~ **TPTC004** Hil **AS/NZS60950-1** & CBCEXK **IEC62368-1** ntOC) @) ■ Features ■ Ultra slim design with 17.5mm( o Ⅱ ass LPS (Limited power source) > ooling by free air convection (working temperature:-30~+70°C) ■ DIN rail TS-35/7.5 or 15 mountable MW Search: https://www.meanwell.com/serviceGTIN.aspx ED indicator for power on ## ■ working efficiency up to 87%, the entire series can operate at the ambient temperature between -30 ℃ and 70 ℃ _ under air convection. The complete protection functions and relevant certificates for home ## ■ _File Name:HDR-15-SPEC 2024-03-11_ **- HDR 15 series** 15W Ultra Slim Step Shape DIN Rail ## **SPECIFICATION** ||**HDR-15-5**<br>**HDR-15-12**<br>**HDR-15-15**<br>**HDR-15-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>2.4A<br>1.25A<br>1A<br>0.63A<br>0 ~ 2.4A<br>0 ~ 1.25A<br>0 ~ 1A<br>0 ~ 0.63A<br>12W<br>15W<br>15W<br>15.2W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>47<br>63Hz<br>~<br>80%<br>85%<br>85.5%<br>86%<br>0.5A/115VAC 0.25A/230VAC<br>COLD START 25A/115VAC 45A/230VAC<br>110<br>145%<br>~<br>rated output power<br>Protection type :Shut off o/p voltage, clamping by zener diode<br>-30<br>+70<br>(Refer to "Derating Curve")<br>~<br>℃<br>20<br>90% RH non-condensing<br>~<br>-40<br>+85<br>, 10<br>95% RH non-condensing<br>~<br>~<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>) RH non-condensing<br>10<br>500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>~<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>17.5*90*54.5mm (W*H*D)<br>74g;160pcs/12.9Kg/1.09CUFT<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**HDR-15-48**<br>48V<br>0.32A<br>0 ~ 0.32A<br>15.4W<br>240mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>87%<br>5 75<br>6 75<br>.<br>. V<br>~<br>1 .<br>1 . V<br>4 2<br>6 2<br>~<br>18.8<br>22.5V<br>~<br>30<br>36V<br>~<br>5 .<br>6 . V<br>6 5<br>4 8<br>~<br>13.5 ~ 18V<br>21.6 ~ 29V<br>10.8 ~ 1 . V<br>3 8<br>4.5 ~ . V<br>5 5<br>43.2 ~ 55.2V<br>85<br>2 VAC (<br>) 120<br>3 VDC (<br>)<br>~<br>~<br>64<br>277VAC operational<br>70<br>390VDC operational<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>BS EN/EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>BS EN/<br>**Test Level /Note**<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>BS EN/<br>EN61000-4-4<br>BS EN/<br>EN61000-4-6<br>BS EN/<br>EN61000-4-5<br>BS EN/<br>EN61000-4-8<br>BS EN/<br>EN61000-4-11<br>BS EN/<br>Voltage Dips and interruptions<br>BS EN/EN55032(CISPR32), CNS15936<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>BS EN/EN55032(CISPR32), CNS15936<br>UL62368-1, U 508, TUV BS EN/EN61558-2-16<br>IEC62368-1,<br>, BSMI CNS15598-1 a<br>L<br>,<br>,<br>pproved;<br>BS EN/EN61558-1<br>EAC TP TC 004<br>Design refer to TUV<br>EN62368-1<br>BS EN/<br>**OPERATING ALTITUDE**<br>2000 meters<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>F & 47<br>F parallel capacitor.<br>μ<br>μ<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:<br>EN55035,<br>EN61000-6-2,<br>EN61204-3<br>BS EN/<br>BS EN/<br>BS EN/<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>**OVER VOLTAGE CATEGORY**<br>According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������<br>3724.3K hrs min.<br>Telcordia SR-332 (Bellcore) ; 1166.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**HDR-15-5**<br>**HDR-15-12**<br>**HDR-15-15**<br>**HDR-15-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>2.4A<br>1.25A<br>1A<br>0.63A<br>0 ~ 2.4A<br>0 ~ 1.25A<br>0 ~ 1A<br>0 ~ 0.63A<br>12W<br>15W<br>15W<br>15.2W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>47<br>63Hz<br>~<br>80%<br>85%<br>85.5%<br>86%<br>0.5A/115VAC 0.25A/230VAC<br>COLD START 25A/115VAC 45A/230VAC<br>110<br>145%<br>~<br>rated output power<br>Protection type :Shut off o/p voltage, clamping by zener diode<br>-30<br>+70<br>(Refer to "Derating Curve")<br>~<br>℃<br>20<br>90% RH non-condensing<br>~<br>-40<br>+85<br>, 10<br>95% RH non-condensing<br>~<br>~<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>) RH non-condensing<br>10<br>500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>~<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>17.5*90*54.5mm (W*H*D)<br>74g;160pcs/12.9Kg/1.09CUFT<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**HDR-15-48**<br>48V<br>0.32A<br>0 ~ 0.32A<br>15.4W<br>240mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>87%<br>5 75<br>6 75<br>.<br>. V<br>~<br>1 .<br>1 . V<br>4 2<br>6 2<br>~<br>18.8<br>22.5V<br>~<br>30<br>36V<br>~<br>5 .<br>6 . V<br>6 5<br>4 8<br>~<br>13.5 ~ 18V<br>21.6 ~ 29V<br>10.8 ~ 1 . V<br>3 8<br>4.5 ~ . V<br>5 5<br>43.2 ~ 55.2V<br>85<br>2 VAC (<br>) 120<br>3 VDC (<br>)<br>~<br>~<br>64<br>277VAC operational<br>70<br>390VDC operational<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>BS EN/EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>BS EN/<br>**Test Level /Note**<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>BS EN/<br>EN61000-4-4<br>BS EN/<br>EN61000-4-6<br>BS EN/<br>EN61000-4-5<br>BS EN/<br>EN61000-4-8<br>BS EN/<br>EN61000-4-11<br>BS EN/<br>Voltage Dips and interruptions<br>BS EN/EN55032(CISPR32), CNS15936<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>BS EN/EN55032(CISPR32), CNS15936<br>UL62368-1, U 508, TUV BS EN/EN61558-2-16<br>IEC62368-1,<br>, BSMI CNS15598-1 a<br>L<br>,<br>,<br>pproved;<br>BS EN/EN61558-1<br>EAC TP TC 004<br>Design refer to TUV<br>EN62368-1<br>BS EN/<br>**OPERATING ALTITUDE**<br>2000 meters<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>F & 47<br>F parallel capacitor.<br>μ<br>μ<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:<br>EN55035,<br>EN61000-6-2,<br>EN61204-3<br>BS EN/<br>BS EN/<br>BS EN/<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>**OVER VOLTAGE CATEGORY**<br>According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������<br>3724.3K hrs min.<br>Telcordia SR-332 (Bellcore) ; 1166.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**HDR-15-5**|**HDR-15-12**|**HDR-15-12**|**HDR-15-15**|**HDR-15-24**|**HDR-15-24**|**HDR-15-48**| |---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|5V|12V||15V|24V||48V| |||**RATED CURRENT**|2.4A|1.25A||1A|0.63A||0.32A| |||**CURRENT RANGE**|0 ~ 2.4A|0 ~ 1.25A||0 ~ 1A|0 ~ 0.63A||0 ~ 0.32A| |||**RATED POWER**|12W|15W||15W|15.2W||15.4W| |||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|120mVp-p||120mVp-p|150mVp-p||240mVp-p| |||**VOLTAGE ADJ. RANGE**|4.5 ~ . V<br>5 5|10.8 ~ 1 . V<br>3 8||13.5 ~ 18V|21.6 ~ 29V||43.2 ~ 55.2V| |||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**LINE REGULATION**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**LOAD REGULATION**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**SETUP, RISE TIME**|2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load||||||| |||**HOLD UP TIME (Typ.)**|30ms/230VAC 12ms/115VAC at full load||||||| |||**VOLTAGE RANGE**|85<br>2 VAC (<br>) 120<br>3 VDC (<br>)<br>~<br>~<br>64<br>277VAC operational<br>70<br>390VDC operational||||||| |||**FREQUENCY RANGE**|47<br>63Hz<br>~||||||| |||**EFFICIENCY (Typ.)**|80%|85%||85.5%|86%||87%| |||**AC CURRENT (Typ.)**|0.5A/115VAC 0.25A/230VAC||||||| |||**INRUSH CURRENT (Typ.)**|COLD START 25A/115VAC 45A/230VAC||||||| |||**OVERLOAD**|110<br>145%<br>~<br>rated output power<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������||||||| |||**OVER VOLTAGE**|Protection type :Shut off o/p voltage, clamping by zener diode<br>5 75<br>6 75<br>.<br>. V<br>~<br>1 .<br>1 . V<br>4 2<br>6 2<br>~<br>18.8<br>22.5V<br>~<br>30<br>36V<br>~<br>5 .<br>6 . V<br>6 5<br>4 8<br>~||||||| |||**WORKING TEMP.**|-30<br>+70<br>(Refer to "Derating Curve")<br>~<br>℃||||||| |||**WORKING HUMIDITY**|20<br>90% RH non-condensing<br>~||||||| |||**STORAGE TEMP., HUMIDITY**|-40<br>+85<br>, 10<br>95% RH non-condensing<br>~<br>~<br>℃||||||| |||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>) RH non-condensing||||||| |||**VIBRATION**|10<br>500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>~||||||| |||**OPERATING ALTITUDE**|2000 meters||||||| |||**OVER VOLTAGE CATEGORY**|According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ||||||| |||**SAFETY STANDARDS**|UL62368-1, U 508, TUV BS EN/EN61558-2-16<br>IEC62368-1,<br>, BSMI CNS15598-1 a<br>L<br>,<br>,<br>pproved;<br>BS EN/EN61558-1<br>EAC TP TC 004<br>Design refer to TUV<br>EN62368-1<br>BS EN/||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC||||||| |||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||| ||||**Parameter**||**Standard**|||**Test Level / Note**|| ||||Conducted||BS EN/EN55032(CISPR32), CNS15936|||Class B|| ||||Radiated||<br>BS EN/EN55032(CISPR32), CNS15936|||Class B|| ||||Harmonic Current||BS EN/EN61000-3-2|||Class A|| ||||Voltage Flicker||BS EN/EN61000-3-3|||-------|| ||||EN55035,<br>EN61000-6-2,<br>EN61204-3<br>BS EN/<br>BS EN/<br>BS EN/||||||| ||||**Parameter**||**Standard**|||**Test Level /Note**|| ||||ESD||EN61000-4-2<br>BS EN/|||Level 3, 8KV air; Level 2, 4KV contact, criteria A|| ||||Radiated Susceptibility||EN61000-4-3<br>BS EN/|||Level 3, criteria A|| ||||EFT/Burest||EN61000-4-4<br>BS EN/|||Level 3, criteria A|| ||||Surge||EN61000-4-5<br>BS EN/|||Level 4,2KV/L-N, criteria A|| ||||Conducted||EN61000-4-6<br>BS EN/|||Level 3, criteria A|| ||||Magnetic Field||EN61000-4-8<br>BS EN/|||Level 4, criteria A|| ||||Voltage Dips and interruptions||EN61000-4-11<br>BS EN/|||><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>>|| |||**MTBF**|3724.3K hrs min.<br>Telcordia SR-332 (Bellcore) ; 1166.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| |||**DIMENSION**|17.5*90*54.5mm (W*H*D)||||||| |||**PACKING**|74g;160pcs/12.9Kg/1.09CUFT||||||| |||1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>F & 47<br>F parallel capacitor.<br>μ<br>μ<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:|||||||| _File Name:HDR-15-SPEC 2024-03-11_ **- HDR 15 series** ## 15W Ultra Slim Step Shape DIN Rail ## **Block Diagram** **==> picture [492 x 458] intentionally omitted <==** **----- Start of picture text -----**<br> RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P & &<br>SWITCHING<br>FILTER -V<br>FILTER FILTER<br>DETECTION<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80<br>80<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 277<br>(operational)<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HDR-15-SPEC 2024-03-11_ **- HDR 15 series** 15W Ultra Slim Step Shape DIN Rail ## **Mechanical Specification** (Unit: mm , tolerance ± 0.5mm) **==> picture [418 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> 58.4<br>17.5<br>54.5<br>1 2<br>3 4<br>90 63.65 45.15<br>35<br>**----- End of picture text -----**<br> ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 |Terminal Pin No. Assignment|Terminal Pin No. Assignment|Terminal Pin No. Assignment|Terminal Pin No. Assignment| |---|---|---|---| |Pin No|.<br>Assignment|Pin No.|Assignment| |1|+V|3|AC/N| |2|-V|4|AC/L| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HDR-15-SPEC 2024-03-11_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →