Image not available
Illustrative purposes only
HDR-100-15
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 92 W, 15 VDC, 6.13 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:92W; Output Voltage - Output 1:15V; Output Current - Output 1:6.13A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HDR-100 Series
- No. of Outputs: 1 Output
- Output Power Max: 92W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 6.13A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 34.9 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- HDR 100 series** 85 ~ 100W Ultra Slim Step Shape DIN Rail **==> picture [264 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>(Blank type only) LPS @ UL508 UL60950-1 W Z EN61558www.ID 2000000000tuv.com ICBCER IEC60950-1<br>**----- End of picture text -----**<br> ## La Features Ultra slim design with 70mm( - ‧ - ‧ - ‧ass LPS (Limited power source) for Blank type ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ / - ‧ooling by free air convection (working temperature:-30~+70°C) - ‧DIN rail TS-35/7.5 or 15 mountable - ‧Ⅲ - ‧ED indicator for power on - ‧ ## ■ **** ℃ ℃ ## ■ ** ** aie **** fl ~~e~~ |****|****||****| |---|---|---|---| ||||| |<br>|||| _File Name:HDR-100-SPEC 2017-10-12_ **- HDR 100 series** ## 85 ~ 100W Ultra Slim Step Shape DIN Rail ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|**SPECIFICATION**|||||||||| |---|---|---|---|---|---|---|---|---|---|---|---| |88%<br>89%<br>90%<br>90%<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD Note.4**<br>**OVER VOLTAGE**<br>500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational )<br>47 ~ 63Hz<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-30 ~ +70�(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85�, 10 ~ 95% RH non-condensing<br>�0.03%/�(0 ~ 50�) RH non-condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>856.5K hrs min. MIL-HDBK-217F (25�)<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25�/ 70% RH<br>UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved; Design refer to TUV EN60950-1<br>℃<br><br><br><br><br><br><br><br><br>EN55024, EN61000-6-2, EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current (Note 5)<br>Voltage Flicker<br>**Standard**<br>EN55032(CISPR32)<br>EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-6<br>EN61000-4-5<br>EN61000-4-8<br>EN61000-4-11<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>EN55032(CISPR32)<br>**OPERATING ALTITUDE**<br>2000 meters<br>**HDR-100-12**<br>**HDR-100-15**<br>**HDR-100-24**<br>12V<br>15V<br>24V<br>7.1A<br>6.13A<br>3.83A<br>0 ~ 7.1A<br>0 ~ 6.13A<br>0 ~ 3.83A<br>85.2W<br>92W<br>92W<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>�1.0%<br>�1.0%<br>�1.0%<br>�2.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>�1.0%<br>**HDR-100-48**<br>48V<br>1.92A<br>0 ~1.92A<br>92.2W<br>240mVp-p<br>�1.0%<br>�1.0%<br>�1.0%<br>3A/115VAC 1.6A/230VAC<br>COLD START 35A/115VAC 70A/230VAC<br>HDR-100 : 102 ~ 110% rated output power;HDR-100-xxN : 105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>14.2 ~ 16.2V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>56.5 ~ 64.8V<br>70*90*54.5mm (W*H*D)<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>0.27Kg; 48pcs/14Kg/1.10CUFT<br>15 ~ 17V<br>24 ~ 25.5V<br>12 ~ 13V<br>48 ~ 48.7V<br>**Non LPS**<br>**Pass LPS**<br>**RANGE**<br>**VOLTAGE ADJ.**<br>13.5 ~ 18V<br>21.6 ~ 29V<br>12~ 13.8V<br>43.2 ~ 55.2V<br>**HDR-100-12N**<br>7.5A<br>0 ~ 7.5A<br>90W<br>**HDR-100-15N**<br>6.5A<br>0 ~ 6.5A<br>97.5W<br>**HDR-100-24N**<br>4.2A<br>0 ~ 4.2A<br>100.8W<br>**HDR-100-48N**<br>2.1A<br>0 ~ 2.1A<br>100.8W<br>μ<br>μ<br>**OVER VOLTAGE CATEGORY**<br> Ⅲ;According to EN61558, EN50178,EN60664-1, EN62477-1;altitude up to 2000meters|||**HDR-100-12**|**HDR-100-12N**|**HDR-100-15**||**HDR-100-15N**|**HDR-100-24**|**HDR-100-24N**|**HDR-100-48**|**HDR-100-48N**| ||**DC VOLTAGE**||12V||15V|||24V||48V|| ||**RATED CURRENT**||7.1A|7.5A|6.13A||6.5A|3.83A|4.2A|1.92A|2.1A| ||**CURRENT RANGE**||0 ~ 7.1A|0 ~ 7.5A|0 ~ 6.13A||0 ~ 6.5A|0 ~ 3.83A|0 ~ 4.2A|0 ~1.92A|0 ~ 2.1A| ||**RATED POWER**||85.2W|90W|92W||97.5W|92W|100.8W|92.2W|100.8W| ||**RIPPLE & NOISE (max.)Note.2**||120mVp-p||120mVp-p|||150mVp-p||240mVp-p|| ||**RANGE**<br>**VOLTAGE ADJ.**|**Non LPS**<br>**Pass LPS**|12 ~ 13V<br>12~ 13.8V||15 ~ 17V<br>13.5 ~ 18V|||24 ~ 25.5V<br>21.6 ~ 29V||48 ~ 48.7V<br>43.2 ~ 55.2V|| ||**VOLTAGE TOLERANCENote.3**||�2.0%||�1.0%|||�1.0%||�1.0%|| ||**LINE REGULATION**||�1.0%||�1.0%|||�1.0%||�1.0%|| ||**LOAD REGULATION**||�1.0%||�1.0%|||�1.0%||�1.0%|| ||**SETUP, RISE TIME**||500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load||||||||| ||**HOLD UP TIME (Typ.)**||30ms/230VAC 12ms/115VAC at full load||||||||| ||**VOLTAGE RANGE**||85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational )||||||||| ||**FREQUENCY RANGE**||47 ~ 63Hz||||||||| ||**EFFICIENCY (Typ.)**||88%||89%|||90%||90%|| ||**AC CURRENT (Typ.)**||3A/115VAC 1.6A/230VAC||||||||| ||**INRUSH CURRENT (Typ.)**||COLD START 35A/115VAC 70A/230VAC||||||||| ||**OVERLOAD Note.4**||HDR-100 : 102 ~ 110% rated output power;HDR-100-xxN : 105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed||||||||| ||**OVER VOLTAGE**||Protection type : Shut down o/p voltage, re-power on to recover<br>14.2 ~ 16.2V<br>18.8 ~ 22.5V<br>30 ~ 36V<br>56.5 ~ 64.8V||||||||| ||**WORKING TEMP.**||-30 ~ +70�(Refer to "Derating Curve")||||||||| ||**WORKING HUMIDITY**||20 ~ 90% RH non-condensing||||||||| ||**STORAGE TEMP., HUMIDITY**||-40 ~ +85�, 10 ~ 95% RH non-condensing||||||||| ||**TEMP. COEFFICIENT**||�0.03%/�(0 ~ 50�) RH non-condensing||||||||| ||**VIBRATION**||10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||||||| ||**OPERATING ALTITUDE**||2000 meters||||||||| ||**OVER VOLTAGE CATEGORY**||Ⅲ;According to EN61558, EN50178,EN60664-1, EN62477-1;altitude up to 2000meters||||||||| ||**SAFETY STANDARDS**||UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved; Design refer to TUV EN60950-1||||||||| ||**WITHSTAND VOLTAGE**||I/P-O/P:4KVAC||||||||| ||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**||I/P-O/P:100M Ohms / 500VDC / 25�/ 70% RH||||||||| ||||**Parameter**|||**Standard**|||**Test Level / Note**||| ||||Conducted|||EN55032(CISPR32)|||Class B||| ||||Radiated|||EN55032(CISPR32)|||Class B||| ||||Harmonic Current (Note 5)|||EN61000-3-2|||Class A||| ||||Voltage Flicker|||EN61000-3-3|||-------||| ||||EN55024, EN61000-6-2, EN61204-3||||||||| ||||**Parameter**|||**Standard**|||**Test Level /Note**||| ||||ESD|||EN61000-4-2|||Level 3, 8KV air; Level 2, 4KV contact, criteria A||| ||||Radiated Susceptibility|||EN61000-4-3|||Level 3, criteria A||| ||||EFT/Burest|||EN61000-4-4|||Level 3, criteria A||| ||||Surge|||EN61000-4-5|||Level 4,2KV/L-N, criteria A||| ||||Conducted|||EN61000-4-6|||Level 3, criteria A||| ||||Magnetic Field|||EN61000-4-8|||Level 4, criteria A||| ||||Voltage Dips and interruptions|||EN61000-4-11|||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods||| ||**MTBF**||856.5K hrs min. MIL-HDBK-217F (25�)||||||||| ||**DIMENSION**||70*90*54.5mm (W*H*D)||||||||| ||**PACKING**||0.27Kg; 48pcs/14Kg/1.10CUFT||||||||| ||℃<br><br><br><br><br><br><br><br><br>μ<br>μ||||||||||| _File Name:HDR-100-SPEC 2017-10-12_ **HDR-100 series** 85 ~ 100W Ultra Slim Step Shape DIN Rail ## **Block Diagram** **==> picture [469 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>DETECTION<br>CIRCUIT<br>PWM<br>O.L.P.<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> **Derating Curve VS Ambient Temperature** **==> picture [152 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Output Derating VS Input Voltage<br>**----- End of picture text -----**<br> **==> picture [468 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>100 230VAC Input<br>90<br>80<br>80<br>110VAC Input<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 45 50 60 70 (VERTICAL) 85 95 100 110 115 120 140 160 180 200 220 240 277<br>(operational)<br>AMBIENT TEMPERATURE ( � ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HDR-100-SPEC 2017-10-12_ **HDR-1 00 series** ## 85 ~ 100W Ultra Slim Step Shape DIN Rail ## **Mechanical Specification** (Unit: mm , tolerance ± 0.5mm) **==> picture [471 x 305] intentionally omitted <==** **----- Start of picture text -----**<br> 58.4<br>70 70 54.5<br>3 4 5 6 3 4 5 6<br>1 2 1 2<br>90 63.65 45.15<br>35<br>**----- End of picture text -----**<br> **==> picture [185 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>**----- End of picture text -----**<br> Terminal Pin No. Assignment |Pin No.<br>Ass|Pin No.<br>ignment| |---|---| |1<br>|AC/L<br>3,4| |A<br>2|C/N<br>5,6| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HDR-100-SPEC 2017-10-12_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →