HDL3000PS400
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 3 kW, 400 VDC, 7.5 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: HDL3000-HV Series
- No. of Outputs: 1Outputs
- Output Power Max: 3kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 400VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1122.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
AC-DC POWER SUPPLIES ## HDL3000 HV Series ## 3000W **FANCOOLED** The HDL3000 HV series offers users both output voltage and output current programming (0 – 105%) via resistance, voltage or digital bus in a very high efficiency, high power density 3kW chassis mount package. Measuring just 6.69” x 2.52” x 11.02”, the HDL3000 HV also features active current sharing, built-in ORing diode, remote on/off and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5V at 0.5A or 9V at 0.3A. ## **Features** Co - High efficiency up to 92% - High power density - DC outputs from 150-400VDC - Programmable output voltage (0-105%) - Programmable output current (0-105%) - I2C, RS485 & RS232 interfaces - Parallel operation - Fully featured signals & controls • 3 year warranty **==> picture [148 x 74] intentionally omitted <==** **----- Start of picture text -----**<br> Applications<br>Industrial Lasers LED Heating Robotics<br>Electronics<br>**----- End of picture text -----**<br> ## **Dimensions** 6.69” x 2.52” x 11.87” (170.0 x 64.0 x 301.49mm) including connectors ## **Models & Ratings** Co |Model Number<br>HDL3000PS150|Output Power|Output Power|Output Voltage<br>150VDC|Output Current<br>High Line<br>Low Line<br>20.0A<br>13.3A|Output Current<br>High Line<br>Low Line<br>20.0A<br>13.3A|Ripple & Noise<br>1500mV|Efficiency(1)<br>91%| |---|---|---|---|---|---|---|---| ||High Line<br>3000W|Low Line<br>2000W|||||| |HDL3000PS200|3000W|2000W|200VDC|15.0A|10.0A|2000mV|91%| |HDL3000PS250|3000W|2000W|250VDC|12.0A|8.0A|2500mV|91%| |HDL3000PS300|3000W|2000W|300VDC|10.0A|6.7A|3000mV|92%| |HDL3000PS400|3000W|2000W|400VDC|7.50A|5.0A|4000mV|92%| Notes: 1. Measured with 230VAC input and full load. AC-DC POWER SUPPLIES ## HDL3000 HV Series ## **Input** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage|90||264|VAC|See derating curve| |Input Frequency|47||63|Hz|| |Power Factor||0.98/0.95|||115/230VAC full load| |Input Current|||19.7/14.5|A|115VAC at 2000W/230VAC at 3000W| |Inrush Current|||43/85||115/230VAC| |Earth Leakage Current|||1|mA|264VAC/60Hz| ## **Output** **==> picture [540 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|150||400|VDC|See Models and Ratings table| |Output Trim||±5||%|By potentionmeter| |Output Voltage Program|0||105|%|Of rated output. Tolerance ±2%| |Output Current Program|0||105|%|Of rated output. Tolerance ±3%| |Voltage Tolerance(1)|||±2|%|Of rated output voltage(1)| |Current Tolerance(1)|||±3|%|Of rated output current(1)| |Minimum Load|0|||A|| |Start Up Delay|||1.1|s|| |Start Up Rise Time|||350|ms|At full load| |Hold Up Time||10||ms|At 230VAC and full load| |Line Regulation|||±1|%|| |Load Regulation|||±1 (V1) /±3|%|V1 Standby. 0-100% load| |Transient Response||<1||%|For a 25% step load change| |Ripple & Noise|1500||4000|mV pk-pk|See models and ratings table.<br>Measured with 20MHz bandwidth and using 12” twisted pair wire<br>terminated with 0.1µF ceramic capacitor and<br>47µF electrolytic at 25°C ambient.| |Overvoltage Protection|Tracks output voltage, see application notes. Recycle AC to reset. Tolerance 7%.||||| |Overtemperature Protection|Internally. Output shuts down, auto recovers.||||| |Overload Protection||105|||Rated power, constant current.| |Short Circuit Protection|||||Auto recovery.| |Temperature Coeffcient||±0.02||%/°C|0-50°C| |Enable|Output must be enabled, see application notes, power supply is shipped with enable links ftted.||||| |Current Share|8 supplies can share within 5%. If total load is less than 5% of rated load only one unit will operate.||||| |Standby Output|5V at 0.5A, present whenever AC is applied (9 V at 0.3A, user selectable, by connecting ‘VSET’, Pin 6 of CN5 to GND of CN5).||||| Notes: 1. Tolerance includes setup time tolerance, line regulation and load regulation. 2 AC-DC POWER SUPPLIES ## HDL3000 HV Series ## **Output Voltage Programming** **==> picture [473 x 620] intentionally omitted <==** **----- Start of picture text -----**<br> Via External Voltage Via External Resistor<br>120 120<br>100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>0 a 0 a<br>0 1 2 3 4 4.5 4.8 5 0 1 2 3 4 4.5 4.8 5<br>Programming Voltage (VDC) Resistor Value (k Ω)<br>Output Current Programming<br>Via External Voltage Via External Resistor<br>120 120<br>100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>0 0<br>0 1 2 3 4 4.5 4.8 5 0 1 2 3 4 4.5 4.8 5<br>Programming Voltage (VDC) Resistor Value (k Ω)<br> Output Voltage/Current Programming<br>oo | | |<br>I climA | Ic=1mA= | IC=1mA= |<br>I-sink | | |<br>min 1mA | | |<br>| 220R VC =ICxR<br>CTRL VCV/ACI| PWMAD — CTRL VCV/ACI o-svoc = CTRL VCV/ACI R=0-5K<br>| Lt<br>|<br>| | = |<br>|<br>Power Supply _Power Supply| _Power Supply|<br>General<br>Characteristic Minimum Typical Maximum Units Notes & Conditions<br>Efficiency 91 % See Models and Ratings table.<br>Isolation: Input to Output 3000 VAC<br>Input to Ground 1500 VAC<br>Output to Ground 500 VAC<br>70 PFC.<br>Switching Frequency 55 95 kHz PWM, variable.<br>40 150 Standby, variable.<br>Power Density 14.4 W/in [3]<br>Signals and Controls Enable, Current Share, V Program, I Program, 5 V Standby, Power OK.<br>Mean Time Between Failure 495 khrs MIL-HDBK-217F, 25°C GB.<br>Weight 7.26 (3.3) lb(g)<br>Output Voltage (%) Output Voltage (%)<br>Output Current (%) Output Current (%)<br>**----- End of picture text -----**<br> ## **Output Voltage/Current Programming** 3 AC-DC POWER SUPPLIES ## HDL3000 HV Series **Environmental** — **==> picture [529 x 302] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>Operating Temperature -20 60 °C Derate linearly from 100% load at 50°C to 50% load at 60°C.<br>Storage Temperature -40 +85 °C 10-95% RH, non condensing.<br>Cooling Internal fan fitted, speed increases with load and internal temperature.<br>Humidity 20 90 %RH Non-condensing<br>Operating Altitude 3000 m<br>Vibration 2 g 10-500Hz, 10 min/cycle, 60 min period for each axis, compliant to IEC60068-2-16, IEC 60068-2-64.<br>Derating Curve<br>QD<br>Thermal Derating Input Derating<br>100<br>100<br>3000W<br>90<br>80<br>80<br>60 70<br>50<br>60 2000W<br>40<br>50<br>20<br>40<br>ea :<br>-20 -10 0 10 20 30 40 50 60 70 90 115 140 180 264<br>Ambient Temperature (˚C) Input Voltage (VAC)<br>Load (%)<br>Load (%)<br>**----- End of picture text -----**<br> ## **Derating Curve** ~~QD~~ ## **Signals & Controls** |Characteristic|Output Status| |---|---| |Solid (Green)|DC Output OK| |Solid (Orange)|DC Output OK in remote control mode| |Slow Blink (Green)|Output Not Enabled| |Slow Blink (Orange)|Output Not Enabled in remote control mode| |Fast Blink (Red)|Over Voltage| |Solid (Red)|Over Loaded| |Slow Blink (Red)|Over Temperature| |Intermittent Blink (Red)|Fan Fail| |Short & LongBlink (Red)|AUX StandbyFailure| ## **Remote Enable** **==> picture [469 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> AUX AUX AUX OFF Power OFF<br>ON Power ON<br>2KΩ EN+ SW 2KΩ EN+ 2KΩ EN+<br>L Power OFF SW<br>AUX EN- OFFON Power OFFPower ON AUX EN- H Power ON AUX EN- External DC source(max = 9VDC)<br>L / H<br>GND GND GND GND<br>cr c ee<br>(A) Using internal auxilliary standby (B) Using external transistor (C) Using external voltage source<br>*GND shown in above diagram is referring to the GND of CN5, not the grounding from output power (NEG (-))<br>**----- End of picture text -----**<br> 4 AC-DC POWER SUPPLIES ## HDL3000 HV Series ## **EMC: EmissionsGeneral** |Phenomenon<br>Conducted|Standard<br>EN55032|Test Level<br>Class A|Notes & Conditions| |---|---|---|---| |Radiated|EN55032|Class A|| |Harmonic Currents|EN61000-3-2|Class A|| |Voltage Flicker|EN61000-3-3||| ## **EMC: Immunity** |Phenomenon|Standard|Test Level|Criteria|Notes & Conditions| |---|---|---|---|---| |ESD Immunity|EN61000-4-2|2 / 3|A|±4kV contact / ±8kV air discharge| |Radiated Immunity|EN61000-4-3|3 V/m|A|| |EFT|EN61000-4-4|±1kV|A|| |Surge|EN61000-4-5|Installation class 3|A|| |Conducted|EN61000-4-6|3Vrms|A|| |Dips||1A/m|A|| ||EN55024|Int. >95% 10ms|A|| |Interrupt||Int. >95% 5000ms|B|| ## **Safety Approvals** |Safety Agency|Standard|Notes & Conditions| |---|---|---| |CB Report|IEC62368-1: 2014|| |UL|UL62368-1, CAN/CSA C22.2 No.62368-1-14|Audio/Video, Information and Communication<br>Technology Equipment| |TUV|EN62368-1: 2014/A11: 2017|| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| **==> picture [547 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> Application Notes<br>Power OK Signal OVP Settings<br>OVP Trip Point<br>POWER SUPPLY<br>Aux 200%<br>3300R 196%<br>Pok<br>Power not OK<br>Power OK 120%<br>114%<br>GND<br>CN2 Connector 7% 100% 105%<br>% of Nominal Output Voltage<br>Open drain signal, low when PSU turns on.<br>Maximum sink current: 20mA Maximum drain voltage: 40V [a] [a]<br>5<br>**----- End of picture text -----**<br> AC-DC POWER SUPPLIES ## HDL3000 HV Series ## CoD **Application Notes** ## **RS232 Connection Diagram** **==> picture [305 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> 1 3 5 7 9 11 13 15 17 19 21 23<br>DA+<br>DA- RS485 to RS232<br>converter<br>GND1<br>2 4 6 8 10 12 14 16 18 20 22 24 PC<br>**----- End of picture text -----**<br> ## **Current Sharing** **==> picture [383 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> Load<br>2 1 2 1 2 1 2 1<br>GND AUX GND AUX GND AUX GND AUX<br>| [| [| | | [[|]<br>GND POK GND POK GND POK GND POK<br>VSET PAR VSET PAR VSET PAR VSET PAR<br>ee<br>GND EN- GND EN- GND EN- GND EN-<br>AUX EN+ AUX EN+ AUX EN+ AUX EN+<br>GND ACI GND ACI GND ACI GND ACI<br>Sf} SS} Fey<br>GND VCI GND VCI GND VCI GND VCI<br>GND AUX GND AUX GND AUX GND AUX<br>—— NC. NC. | fFe|} NC. NC. fee NC. NC. NC. NC.<br>GND1 +5VC GND1 +5VC GND1 + VC GND1 +5VC<br>—— SDA SCL } fe} SDA SCL Jee SDA SCL SDA SCL<br>DA+ DA - DA+ DA- DA+ DA- DA+ DA-<br>oe ee<br>24 23 24 23 24 23 24 23<br>**----- End of picture text -----**<br> Notes: 1. In parallel operation, it is possible that only one unit will operate if the load is less than 5% of the combined rated output load. 2. Output voltage of each PSU among parallel unit 3 should be <0.2VDC difference. 3. Maximum output current should not exceed 90% of the combined rated current of the units in parallel. 6 AC-DC POWER SUPPLIES ## HD ~~L~~ 3000 HV Series ## **Mechanical Details** **==> picture [523 x 542] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||||| |---|---|---|---|---|---|---|---|---|---|---| |0.22 (5.5)|11.02 (280.0)|0.47 (12.0)| |1.87|8.19 (208.0)|2.52 (64.0)| |(47.5)| |1.81| |(46.0)| |4-M4 0.12 (3.0) max| |ZS|||\|CJ|>| |@|a|es|a|=| |3.07|Air flow|6.69| |(78.0)|(170.0)| |).|Tn|i!|;|i|__—| |0.63 (16.0)|=|a| |||AC Mains Connection|sid|0.57|1.34 (34.0)|CN5|.| |Pin|Function|(14.5)|9.33 (237.0)| |1| |2|©|ACL|1.38|a|8-M4(Both Sides)|||ar A|neers| |(35.0)|L=3.0[0.12] max.| |3|ACN| |CN5 Control Pin Connections| |Pin|Function|Description|Pin|Function|Description|Pin|Function|Description| |+5V / 0.5A or +9V /| |1|AUX|9|EN+|Inhibit ON/OFF (+)|17|N.C.| |0.3A Auxiliary power| |+5V / 0.5A or +9V / 0.3A| |2|GND|Ground|10|AUX|18|N.C.| |Auxiliary power| |3|POK|Power OK|11|ACI|I Program|19|+5VC|Use with GND1, isolated supply for I|[2]|C and RS485 interfaces| |4|GND|Ground|12|GND|Ground|20|GND1|Use with +5VC, isolated supply for| |I|[2]|C and RS485 interfaces| |5|PAR|Parallel operation current share|13|VCI|V Program|21|SCL|Serial Clock for I|[2]|C interface| |6|VSET|Aux output setting|14|GND|Ground|22|SDA|Serial Data for I2|[2]|interface| |7|EN-|Inhibit ON/OFF (-)|15|AUX|+5V / 0.5A or +9V|23|DA-|For RS485 Data- Interface| |8|GND|Ground|16|GND|/ 0.3A Auxiliary power|24|DA+|For RS485 Data+ Interface| **----- End of picture text -----**<br> ## **Notes:** 1. Dimensions shown in inches (mm). 4. Torque of mounting M4 screw: 1.27Nm (13.0 kgf.cm) 2. Weight: 7.26lb (3.3kg) 3. Mating Connector: CN5 JST PHDR-24VS Housing, SPHD-002T-P0.5 Contact 7 01 April 2025
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →