- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HBG-100P
- Output Current: 1.6A
- LED Driver Mode: Constant Current
- Output Power Max: 96W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 60VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 30.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
100W Constant Current Mode LED Driver ## **HBG - 100P series** **==> picture [358 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> SELV<br>(for DA Type only)<br>■ Features ■<br>‧ Constant Current mode output ‧<br>‧ ‧<br>Circular shape PCB type design<br>‧ Built-in active PFC function ‧<br>‧ Function options: output adjustable via potentiometer; ‧<br>‧<br>3in 1 dimming; DAL I<br>‧ Typical lifetime>50000 hours<br>‧ 5 years warranty<br>■ Description<br>HBG-100P series is a 100W AC/DC PCB type LED driver featuring the<br>~<br>Itoperates from 90 305VAC and offers constant current output models<br>voltage ranging between 36V and 60V. Thanks to the high efficiency<br>fanless design, the entire series is able to operate for-40 ℃ ~+45 ℃<br>HBG-100P is equipped with various function options, such as dimming<br>provide the optimal design flexibility for LED lighting system.<br>■ Model Encoding<br>HBG - 100P - 36 A<br>**----- End of picture text -----**<br> **==> picture [461 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> Type Function Note<br>|__| A lo adjustable through built-in potentiometer. In<br>|| B 8 in 1 dimming function (1~10Vdc, 10V PWM signal and resistance) In<br>DA<br>**----- End of picture text -----**<br> _File Name:HBG-100P-SPEC 2018-12-06_ ## 100W Constant Current Mode LED Driver ## **HBG - 100P series** ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)Note.5**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURENote.10**<br>**OVER VOLTAGE**<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 45℃)<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**OVER CURRENT**<br>**SAFETY STANDARDS**<br>COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC 127 ~ 431VDC<br>95 ~ 108%<br> PF≧0.96/115VAC, PF≧0.96/230VAC, PF≧0.94/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Ta=-40 ~ +45℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>2000ms / 115VAC 500ms / 230VAC<br>21.6 ~ 36V<br>2.7A<br>97.2W<br>**HBG-100P-36**<br>36 ~ 60V<br>1.6A<br>96W<br>**HBG-100P-60**<br>28.8 ~ 48V<br>2A<br>96W<br>**HBG-100P-48**<br>1.62 ~ 2.7A<br>1.2 ~ 2A<br>1.0 ~ 1.6A<br>91%<br>91.5%<br>91%<br>41 ~ 49V<br>65 ~ 75V<br>54 ~ 63V<br>10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>346.8Khrs min. MIL-HDBK-217F (25℃)<br>Refer to mechanical specification<br>UL8750,CSA C22.2 No.250.13-12; ENEC EN61347-1,EN61347-2-13,EN62384, GB19510.1,GB19510.14,EAC TP TC 004 approved<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3, GB17743, GB17625.1,EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV),EAC TP TC 020<br>Adjustable for A-Type only (via built-in potentiometer)<br>1.1A / 115VAC 0.5A / 230VAC 0.45A / 277VAC<br>Shut down o/p voltage, re-power on to recovery<br>Shut down o/p voltage, re-power on to recovery<br>0.3Kg; 45pcs/14.5Kg/1.60CUFT<br>**RATED CURRENT**<br>**RATED POWER**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME Note.4**<br>**CURRENT TOLERANCE**<br>**CONSTANT CURRENT REGION Note.2**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>**CURRENT RIPPLE**<br>±5.0%<br>5.0% max. @rated current<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedcurrentand25℃ofambienttemperature.<br>2.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".<br>3.De-ratingmaybeneededunderlowinputvoltages.Pleasereferto“STATICCHARACTERISTIC”sectionsfordetails.<br>4.Lengthofsetuptimeismeasuredatfirstcoldstart.TurningON/OFFthepowersupplymayleadtoincreaseofthesetuptime.<br>5.TheDAtypepowersupplyislessefficientthanthetypicalefficiencyinspecificationby1%.<br>6.Thedriverisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe<br>completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.<br>7.Thisseriesmeetsthetypicallifeexpectancyof>50,000hoursofoperationwhenTaisabout45℃orless.<br>8.PleaserefertothewarrantystatementonMEANWELL'swebsiteathttp://www.meanwell.com<br>9.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).<br>10.Allfunctionaltestingmustbefilledwithpotting,includingOTPfunction.<br>37V<br>62V<br>49V<br>Constant current limiting, recovers automatically after fault condition is removed<br>**DALI STANDARDS**<br>Compliance to IEC62386-101, 102, 207 for DA-Type only|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)Note.5**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURENote.10**<br>**OVER VOLTAGE**<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 45℃)<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**OVER CURRENT**<br>**SAFETY STANDARDS**<br>COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC 127 ~ 431VDC<br>95 ~ 108%<br> PF≧0.96/115VAC, PF≧0.96/230VAC, PF≧0.94/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Ta=-40 ~ +45℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>2000ms / 115VAC 500ms / 230VAC<br>21.6 ~ 36V<br>2.7A<br>97.2W<br>**HBG-100P-36**<br>36 ~ 60V<br>1.6A<br>96W<br>**HBG-100P-60**<br>28.8 ~ 48V<br>2A<br>96W<br>**HBG-100P-48**<br>1.62 ~ 2.7A<br>1.2 ~ 2A<br>1.0 ~ 1.6A<br>91%<br>91.5%<br>91%<br>41 ~ 49V<br>65 ~ 75V<br>54 ~ 63V<br>10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>346.8Khrs min. MIL-HDBK-217F (25℃)<br>Refer to mechanical specification<br>UL8750,CSA C22.2 No.250.13-12; ENEC EN61347-1,EN61347-2-13,EN62384, GB19510.1,GB19510.14,EAC TP TC 004 approved<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3, GB17743, GB17625.1,EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV),EAC TP TC 020<br>Adjustable for A-Type only (via built-in potentiometer)<br>1.1A / 115VAC 0.5A / 230VAC 0.45A / 277VAC<br>Shut down o/p voltage, re-power on to recovery<br>Shut down o/p voltage, re-power on to recovery<br>0.3Kg; 45pcs/14.5Kg/1.60CUFT<br>**RATED CURRENT**<br>**RATED POWER**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME Note.4**<br>**CURRENT TOLERANCE**<br>**CONSTANT CURRENT REGION Note.2**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>**CURRENT RIPPLE**<br>±5.0%<br>5.0% max. @rated current<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedcurrentand25℃ofambienttemperature.<br>2.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".<br>3.De-ratingmaybeneededunderlowinputvoltages.Pleasereferto“STATICCHARACTERISTIC”sectionsfordetails.<br>4.Lengthofsetuptimeismeasuredatfirstcoldstart.TurningON/OFFthepowersupplymayleadtoincreaseofthesetuptime.<br>5.TheDAtypepowersupplyislessefficientthanthetypicalefficiencyinspecificationby1%.<br>6.Thedriverisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe<br>completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.<br>7.Thisseriesmeetsthetypicallifeexpectancyof>50,000hoursofoperationwhenTaisabout45℃orless.<br>8.PleaserefertothewarrantystatementonMEANWELL'swebsiteathttp://www.meanwell.com<br>9.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).<br>10.Allfunctionaltestingmustbefilledwithpotting,includingOTPfunction.<br>37V<br>62V<br>49V<br>Constant current limiting, recovers automatically after fault condition is removed<br>**DALI STANDARDS**<br>Compliance to IEC62386-101, 102, 207 for DA-Type only|**HBG-100P-36**|**HBG-100P-48**|**HBG-100P-60**| |---|---|---|---|---| ||**RATED CURRENT**|2.7A|2A|1.6A| ||**RATED POWER**|97.2W|96W|96W| ||**CONSTANT CURRENT REGION Note.2**|21.6 ~ 36V|28.8 ~ 48V|36 ~ 60V| ||**OPEN CIRCUIT VOLTAGE(max.)**|37V|49V|62V| |||Adjustable for A-Type only (via built-in potentiometer)||| ||**CURRENT ADJ. RANGE**<br>**CURRENT RIPPLE**|1.62 ~ 2.7A<br>1.2 ~ 2A<br>1.0 ~ 1.6A<br>5.0% max. @rated current||| ||**CURRENT TOLERANCE**|±5.0%||| ||**SET UP TIME Note.4**|2000ms / 115VAC 500ms / 230VAC||| ||**VOLTAGE RANGENote.3**|(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC 127 ~ 431VDC||| ||**FREQUENCY RANGE**|47 ~ 63Hz||| ||**POWER FACTOR**|PF≧0.96/115VAC, PF≧0.96/230VAC, PF≧0.94/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)||| ||**EFFICIENCY (Typ.)Note.5**|91%|91%|91.5%| ||**AC CURRENT**|1.1A / 115VAC 0.5A / 230VAC 0.45A / 277VAC||| ||**INRUSH CURRENT(Typ.)**|COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC||| ||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed||| ||**OVER VOLTAGE**|41 ~ 49V<br>65 ~ 75V<br>54 ~ 63V<br>Shut down o/p voltage, re-power on to recovery||| ||**OVER TEMPERATURENote.10**|Shut down o/p voltage, re-power on to recovery||| ||**WORKING TEMP.**|Ta=-40 ~ +45℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 45℃)||| ||**VIBRATION**|10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes||| ||**SAFETY STANDARDS**|UL8750,CSA C22.2 No.250.13-12; ENEC EN61347-1,EN61347-2-13,EN62384, GB19510.1,GB19510.14,EAC TP TC 004 approved||| ||**WITHSTAND VOLTAGE**<br>**DALI STANDARDS**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>Compliance to IEC62386-101, 102, 207 for DA-Type only||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH||| ||**EMC EMISSION**|Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3, GB17743, GB17625.1,EAC TP TC 020||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV),EAC TP TC 020||| ||**MTBF**|346.8Khrs min. MIL-HDBK-217F (25℃)||| ||**DIMENSION**|Refer to mechanical specification||| ||**PACKING**<br>0.3Kg; 45pcs/14.5Kg/1.60CUFT<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedcurrentand25℃ofambienttemperature.<br>2.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".<br>3.De-ratingmaybeneededunderlowinputvoltages.Pleasereferto“STATICCHARACTERISTIC”sectionsfordetails.<br>4.Lengthofsetuptimeismeasuredatfirstcoldstart.TurningON/OFFthepowersupplymayleadtoincreaseofthesetuptime.<br>5.TheDAtypepowersupplyislessefficientthanthetypicalefficiencyinspecificationby1%.<br>6.Thedriverisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe<br>completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.<br>7.Thisseriesmeetsthetypicallifeexpectancyof>50,000hoursofoperationwhenTaisabout45℃orless.<br>8.PleaserefertothewarrantystatementonMEANWELL'swebsiteathttp://www.meanwell.com<br>9.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).<br>10.Allfunctionaltestingmustbefilledwithpotting,includingOTPfunction.|||| _File Name:HBG-100P-SPEC 2018-12-06_ ## 100W Constant Current Mode LED Driver ## **HBG - 100P series** ## **BLOCK DIAGRAM** **==> picture [462 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 100KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P.<br>O.T.P. O.L.P. DETECTION<br>FG<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series works in constant current mode to directly drive the LEDs. **==> picture [219 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>Constant<br>Current area<br>60<br>(min.)<br>Hiccup<br>Protection<br>50 100 Io(%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Typical output current normalized by rated current (%) _File Name:HBG-100P-SPEC 2018-12-06_ **HBG - 100P series** 100W Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [356 x 581] intentionally omitted <==** **----- Start of picture text -----**<br> BD1<br>SJTW 18AWG*3C<br>AC/N(Blue)AC/L(Brown) ACNACLFS1<br>FG (Green/Yellow)<br>-V FG C5<br>-V(Black) L1<br>+V T1<br>SJTW 18AWG*2C HS1<br>L100 Q2<br>Q1<br>* DIM+ for B-Type C107<br> DA+ for DA-Type L3<br>* *DIM- for B-Type<br> DA- for DA-Type C106<br>**DIM-(White) VR2 VR1<br>*DIM+(Blue) SVR1 CN1<br>UL2517 22AWG*2C<br>μA (typ.)A (typ.)<br>100%<br>LED Strips 90%<br>+ 80%<br>70%<br>- 60%<br>50%<br>+<br>Additive Voltage 40%<br>- 30%<br>20%<br>10%<br>1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>LED Strips 90%<br>+ 80%<br>70%<br>- 60%<br>50%<br>Additive PWM signal 40%<br>30%<br>20%<br>10%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>+V(Red)<br>ZNR1 C1<br>LF1<br>Q101 G G<br>D<br>S<br>HS2<br>Output current (%)<br>Output current (%)<br>+<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function (for B-Type)** - ‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: - 1 ~ 10VDC, or 10V PWM signal or resistance. - ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. - ‧Dimming source current from power supply: 100μA (typ.)A (typ.) - Applying additive 1 ~ 10VDC **==> picture [211 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> LED Strips<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): **==> picture [211 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> LED Strips<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> _File Name:HBG-100P-SPEC 2018-12-06_ **HBG - 100P series** 100W Constant Current Mode LED Driver **==> picture [224 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive resistance:<br>LED Strips<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> **==> picture [157 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for�synchronized�dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>**----- End of picture text -----**<br> Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options. **==> picture [401 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> N FG L<br>Relay Switch Adjuster<br>10K/N~100K/N Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Blue<br>Green/ DIM+ White<br>Yellow AC/L HBG-100P DIM- Black<br>Brown AC/N B-Type V(-)V(+) Red LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. ## ※ **DALI Interface (primary side; for DA-Type)** - ‧Apply DALI signal between DA+ and DA-. - ‧DALI protocol comprises 16 groups and 64 addresses. - ‧First step is fixed at 8% of output. _File Name:HBG-100P-SPEC 2018-12-06_ **HBG - 100P series** 100W Constant Current Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [241 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>230VAC<br>80<br>230VAC<br>Input only<br>60 100VAC<br>50<br>40<br>20<br>-40 -25 -10 0 15 30 40 45 50 60 (HORIZONTAL)<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [110 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> AMBIENT TEMPERATURE, Ta ( ℃ )<br>**----- End of picture text -----**<br> ## **STATIC CHARACTERISTIC** ## **POWER FACTOR (PF) CHARACTERISTIC** **==> picture [74 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Constant Current Mode<br>**----- End of picture text -----**<br> **==> picture [490 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> 100 1<br>90 0.99<br>0.98<br>80<br>0.97<br>70 0.96<br>277V<br>60 0.95<br>230V<br>0.94<br>50 115V<br>0.93<br>40<br>0.92<br>0.91<br>90 100 125 135 145 155 165 175 180 200 230 305 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) 60Hz LOAD<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> ※De-rating is needed under low input voltage. ## **TOTAL HARMONIC DISTORTION (THD)** ## **EFFICIENCY vs LOAD** HBG-100P series possess superior working efficiency that up to 91.5% can be reached in field applications. **==> picture [44 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 60V Model<br>**----- End of picture text -----**<br> ※ 60V Model **==> picture [498 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 60V Model<br>25%<br>94<br>20%<br>92<br>90<br>15% 88<br>277V<br>277V 86<br>10% 84 230V<br>230V<br>82<br>115V 115V<br>5% 80<br>78<br>0% 76<br>50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>THD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:HBG-100P-SPEC 2018-12-06_ ## 100W Constant Current Mode LED Driver ## **HBG - 100P series** ## **MECHANICAL SPECIFICATION** **==> picture [475 x 420] intentionally omitted <==** **----- Start of picture text -----**<br> Unit:mm<br>※ A-type 34<br>ψ24 1.6<br>300±20<br>BD1<br>AC/N(Blue)AC/L(Brown) SJTW 18AWG*3C ACNACLFS1<br>FG (Green/Yellow)<br>200±20<br>-V FG C5<br>-V(Black) +V 33.75 ψ3.5 T1 L1<br>SJTW 18AWG*2C HS1<br>L100 Q2<br>Q1<br>C107<br>L3<br>C106<br>Io.adj VR2 VR1<br>SVR1 CN1<br>※ B/DA type<br>34<br>ψ24 1.6<br>300±20<br>BD1<br>SJTW 18AWG*3C<br>AC/N(Blue)AC/L(Brown) ACNACLFS1<br>FG (Green/Yellow)<br>200±20<br>-V FG C5<br>-V(Black) +V 33.75 ψ3.5 T1 L1<br>SJTW 18AWG*2C HS1<br>L100 Q2<br>Q1<br>C107<br>L3<br>300±20 C106<br>*DIM+(Blue) VR2 VR1<br>**DIM-(White) SVR1 CN1<br>* DIM+ for B-Type UL2517 22AWG*2C<br> DA+ for DA-Type<br>* *DIM- for B-Type<br> DA- for DA-Type<br>+V(Red)<br>+V(Red)<br>104<br>ψ<br>104<br>ψ<br>ZNR1 C1<br>LF1<br>31<br>Q101 G G<br>D<br>S<br>HS2<br>ZNR1 C1<br>LF1<br>31<br>Q101 G G<br>D<br>S<br>HS2<br>+<br>+<br>**----- End of picture text -----**<br> _File Name:HBG-100P-SPEC 2018-12-06_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →