Image not available
Illustrative purposes only
HAX 1500-S
Current Transducer, Open Loop Hall Effect, AC/DC/Pulsed, 1.5kA, Analogue - ± 4V, ± 15V Supply
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 1%
- Product Range: HAX Series
- Primary Current: 1.5kA
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Analogue
- Supply Voltage Range: ± 15V
- Secondary Signal Type: -4V to 4V
- Current Sensor Technology: Open Loop Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 64.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer HAX 500** … **2500-S** ## _I_ **= 500** … **2500 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data** Lo~~ Type Primary nominal Primary current, RMS current measuring range[1)] _I_ P N (A) _I_ P M (A) HAX 500-S 500 ±1500 HAX 600-S 600 ±1800 HAX 850-S 850 ±2550 HAX 1000-S 1000 ±3000 HAX 1500-S 1500 ±4500 HAX 2000-S 2000 ±5500 HAX 2500-S 2500 ±5500 _U_ C Supply voltage (±5 %)[1)] ±15 V _I_ C Current consumption < +20/−15 mA _Î_ P Overload capability 30000 At _R_ INS Insulation resistance @ 500 V DC > 1000 MΩ _U_ out Output voltage (Analog) @ ± _I_ P N, _R_ L = 10 kΩ, _T_ A = 25 °C ±4 V _R_ out Output internal resistance appr. 100 Ω _R_ L Load resistance > 1 kΩ ~~**Accuracy - Dynamic performance data** Lo~~ _ε_ Error @ _I_ P N, _T_ A = 25 °C (excluding offset)[2)] < ±1 % of _I_ P N _ε_ L Linearity error[3)] (0 … ± _I_ P N) < ±1 % of _I_ P N _U_ O E Electrical offset voltage @ _T_ A = 25 °C < ±20 mV _U_ O H Hysteresis offset voltage @ _I_ P = 0, after an excursion of 1 × _I_ P N < ±30 mV _TCU_ O E Temperature coefficient of _U_ O E < ±1 mV/K _TCU_ out Temperature coefficient of _U_ out (% of reading) < ±0.1 %/K _t_ D 90 Delay time to 90 % of the final output value for _I_ P N step[4)] < 5 µs _BW_ Frequency bandwidth (−3 dB)[5)] DC … 25 kHz ~~**General data** Lo~~ _T_ A Ambient operating temperature −40 ... +85 °C _T_ A st Ambient storage temperature −40 ... +85 °C _m_ Mass appr. 450 g Standards UL 508: 2013 ## ~~**Accuracy - Dynamic performance data** Lo~~ Notes:[1)] Operating at ±12 V < _U_ C < ±15 V will reduce the measuring range - 2) The primary busbar fixed in the center of aperture is recommended. The ## **Features** - ●Hall effect measuring principle - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Low insertion losses - ●Easy installation - ●Low power consumption - ●Small size and space saving - ●Only one design for wide current ratings range - ●High immunity to external interference. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drivers - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power suppliers for welding applications. ## **Application domain** - ●Industrial. - position of busbar has impact on the accuracy of transducer - 3) Linearity data exclude the electrical offset - 4) For a d _i_ / d _t_ = 50 A/µs 5) Please refer to derating curves in the technical file to avoid excessive core heating at high frequency. - 6) Variation of the offset during the test IEC 61000-4-3 between 100 to 200 MHz. N° 74.75.50.000.0, N° 74.75.52.000.0, N° 74.75.57.000.0, N° 74.75.60.000.0, N° 74.75.65.000.0, N° 74.75.69.000.0, N° 74.75.70.000.0 Page 1/3 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 7February2024/Version 26 ## **Current Transducer HAX 500** … **2500-S** ## ~~**Insulation coordination**~~ |_U_d|RMS voltage for AC insulation test, 50 Hz, 1 min|5|kV| |---|---|---|---| |_U_Ni|Impulse withstand voltage 1.2/50 µs|8.3|kV| |_U_t|Partial discharge RMS test voltage (_q_m< 10 pC)|> 660|V| |||Min|| |_d_Cp|Creepage distance|15.7|mm| |_d_CI|Clearance|12.7|mm| |_CTI_|Comparative tracking index (group I)|600|V| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp,_d_CI,_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|1500 V|1000 V| |Reinforced insulation|600 V|600 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 7February2024/Version 26 ## **Dimensions HAX 500** … **2500-S** (in mm) **==> picture [511 x 356] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P U C<br>d Cl d Cp<br>U C<br>**----- End of picture text -----**<br> ## **Remarks** ## **Mechanical characteristics** - _U_ out is positive when _I_ P flows in the direction of the arrow. - ●General tolerance ±1 mm - ●Temperature of the primary conductor should not exceed 100 °C. - ●Transducer fastening 1 hole and 1 notch ⌀ 5.5 mm 2 M5 steel screws - Recommended fastening torque 1.5 N·m - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: . - **https://www.lem.com/en/file/3137/download** |or<br>1 hole and 2 notches⌀5.5 mm<br>3 M5 steel screws<br>Recommended fastening torque 1.5 N·m<br>●Primary through-hole<br>64 × 21 mm<br>●Connection of secondary<br>LEOCO 2501P04V00A1)| |---| - ●Dynamic performances ( d _i_ /d _t_ and delay time) are best with a single bar completely filling the primary hole. Note:[1) ] Recommended mating connector : Molex 511910400 (housing) and 508029101 (contact). - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 7February2024/Version 26
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →