H3RN-1 24VAC
TIMER, MULTIFUNCTION, 24VAC
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Time Delay Relays - Electromechanical
- SVHC:No SVHC (19-Dec-2011); Coil Voltage VAC Nom:24V; Contact Configuration:SPCO; Contact Current AC Max:3A; Contact Voltage AC Max:250V; External Depth:28.8mm; External Length / Height:47.4m
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 37.04 € |
| Current stock | 10+ |
| Lead time | 30 days |
## ~~OMRON~~ **Solid-state Timer H3RN** ~~|~~ ## **Ultra-slim Timer for G2R Relay Socket** - Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. - Standard multiple time ranges and multiple operating modes. - Conforms to VDE 0435/P2021 and approved by UL and CSA. Conforms to EMC standards. RC ~~Ordering Information~~ **Supply voltage Time-limit contact Short-time range model Long-time range model (0.1 s to 10 min) (0.1 min to 10 h)** 24 VAC **;** SPDT H3RN-1 H3RN-11 **12** , **24 VDC** DPST-NO H3RN-2 H3RN-21 ~~a~~ **Note:** Specify both the model number and supply voltage when ordering. Example: H3RN-1 24 VAC Supply voltage **Model Number Legend: H3RN-** jj 1 2 **1. Output 2. Time Range** 1: SPDT None: Short-time range (0.1 s to 10 min) 2: DPST-NO 1: Long-time range (0.1 min to 10 hrs) **Accessories (Order Separately) Connecting Socket Timer Track mounting/Front connecting Back connecting socket socket** H3RN-1/-11 P2RF-05-E P2R-057P H3RN-2/-21 P2RF-08-E P2R-087P ~~ee~~ 4 ~~**H3RN**~~ ~~**H3RN**~~ ## ~~Specifications~~ ## **Ratings** |**Ratings**||| |---|---|---| |**Item**|**H3RN-1/-2**|**H3RN-11/-21**| |**Time ranges**|0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min<br>max. selectable)|0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs<br>max. selectable)| |**Rated supply voltage**|24 VAC; 12, 24 VDC|| |**Pin type**|Plug-in|| |**Operating mode**|ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch|| |**Operating voltage range**|85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)<br>(see note)|| |**Power consumption**|24 VAC:<br>Relay ON:<br>approx. 0.8 VA (at 24 VAC, 60 Hz)<br>Relay OFF:<br>0.5 VA (at 24 VAC, 60 Hz)<br>12 VDC:<br>Relay ON:<br>approx. 0.4 W (at 12 VDC)<br>Relay OFF:<br>0.1 W (at 12 VDC)<br>24 VDC:<br>Relay ON:<br>approx. 0.5 W (at 24 VDC)<br>Relay OFF:<br>0.2 W (at 24 VDC)|| |**Control outputs**|3 A at 250 VAC, resistive load (cos!= 1) (G6B-2j14P-FD-US used)<br>The minimum applicable load is 10 mA at 5 VDC (P reference value).|| |**Note:**<br>When using the H3RN in any place where the ambient temperature is more than 50"C, supply 90% to 110% of the rated voltages<br>(12 VDC: 95% to 110% of the rated voltage).<br>**Characteristics**||| |**Item**|**H3RN-1/-2**|**H3RN-11/-21**| |**Accuracy of operating time**|#1% FS max. (1 s range:#1%#10 ms max.)|| |**Setting error**|#15%#50 ms FS max.|| |**Reset time**|Min. power-opening time: 12, 24 VDC:<br>0.1 s max. (including halfway reset)<br>24 VAC:<br>0.5 s max.(includinghalfwayreset)|| |**Influence of voltage**|#2% FS max.|| |**Influence of temperature**|#2% FS max.|| |**Insulation resistance**|100 M$min. (at 500 VDC)|| |**Dielectric strength**|2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of<br>different poles)<br>1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)|| |**Vibration resistance**|Destruction: 10 to 55 Hz, 0.75-mm single amplitude<br>Malfunction: 10 to 55 Hz, 0.5-mm single amplitude|| |**Shock resistance**|Destruction: 300 m/s2 (approx. 30G)<br>Malfunction: 100 m/s2 (approx. 10G)|| |**Ambient temperature**|Operating:<br>--10"C to 55"C (with no icing)<br>Storage:<br>--25"C to 65"C(with no icing)|| |**Ambient humidity**|Operating:<br>35% to 85%|| |**Life expectancy**|Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)<br>Electrical:<br>100,000 operations min.(3 A at 250 VAC, resistive load at 1,800 operations/h)|| |**Impulse withstand voltage**|Between power terminals: 1 kV|| |**Noise immunity**|#1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1%s, 1-ns rise)|| |**Static immunity**|Destruction: 8 kV<br>Malfunction: 4 kV|| |**Enclosure rating**|IP20|| |**Weight**|Approx. 18 g|| |**EMC**|Emission Enclosure:<br>EN55011 Group 1 class A<br>Emission AC Mains:<br>EN55011 Group 1 class A<br>Immunity ESD:<br>EN61000-4-2: 4 kV contact discharge (level 2)<br>8 kV air discharge (level 3)<br>Immunity RF-interference:<br>ENV50140:<br>10 V/m (amplitude modulated, 80 MHz to<br>1 GHz) (level 3)<br>10 V/m (pulse modulated, 900 MHz)<br>Immunity Conducted Disturbance: ENV50141:<br>10 V (0.15 to 80 MHz) (level 3)<br>Immunity Burst:<br>EN61000-4-4: 2 kV power-line (level 3)<br>2 kV I/O signal-line (level 4)|| |**Approved standards**|UL508, CSA22.2 No. 14<br>Conforms to VDE 0435/P2021 (for built-in use)<br>Conforms to EN50081-2, EN50082-2|| 5 ~~**H3RN**~~ ~~**H3RN**~~ ## ~~Nomenclature~~ **Run/Power Indicator (Green)** (Lit: Power ON) ## **Main Dial** **Output Indicator (Orange)** (Lit: Output ON) Set the desired time according to time range selectable by DIP switch. ## ~~Operation~~ **Timing Chart** |**Timing Chart**<br>~~=~~||| |---|---|---| |**Operating mode**<br>~~ee~~|**Timing chart**<br>~~Ce~~<br>~~re~~|| ||**H3RN-1/-11**<br>~~Ce~~<br>~~re~~|**H3RN-2/-21**<br>~~Ce~~| |**ON-delay**<br>Power<br>Output<br>~~ee~~|Time limit contact<br>NC (4-2)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)<br>Power (1-5)<br>Time limit contact<br>NO (4-3)<br>~~Ce~~<br>~~re~~<br>t<br>Rt<br>t|Power (1-8)<br>Time limit contact<br>NO (4-3, 5-6)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)<br>~~Ce~~<br>:<br>Rt<br>:| |**Interval**<br>Power<br>Output|Time limit contact<br>NC (4-2)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)<br>Power (1-5)<br>Time limit contact<br>NO (4-3)|Power (1-8)<br>Time limit contact<br>NO (4-3, 5-6)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)| |**Flicker OFF-start**<br>Power<br>Output|Time limit contact<br>NC (4-2)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)<br>Power (1-5)<br>Time limit contact<br>NO (4-3)|Power (1-8)<br>Time limit contact<br>NO (4-3, 5-6)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)| |**Flicker ON-start**<br>Power<br>Output|Time limit contact<br>NC (4-2)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)<br>Power (1-5)<br>Time limit contact<br>NO (4-3)<br>==—=.|Power (1-8)<br>Time limit contact<br>NO (4-3, 5-6)<br>Run/Power<br>indicator (PW)<br>Output indicator<br>(OUT)| **Note:** t: Set time Rt: Reset time 6 ~~-~~ ~~**H3RN** _-._ OMRODEO—— " ——~~ ~~**H3RN**~~ ## **DIP Switch Settings** |**Model**<br>~~ee~~|**Time range**<br>~~ee~~|**Time setting**<br>**range**<br>~~ee~~|**Setting**<br>~~ee~~<br>~~ee~~|**Factory-set**<br>~~ee~~<br>~~ee~~| |---|---|---|---|---| |H3RN-1,<br>H3RN-2<br>~~ee~~<br>~~—~~|1 s<br>~~ee~~<br>~~|~~<br>~~ee~~|0.1 to 1 s<br>~~ee~~<br>~~|~~<br>~~ee ee~~|~~ee~~<br>~~ee~~<br>~~|~~<br>~~ee~~|Yes<br>~~ee~~<br>~~ee~~<br>~~|~~<br>~~ee~~| ||10 s<br>~~ee~~<br>~~—~~<br>~~|~~|1 to 10 s<br>~~ee ee~~<br>~~fw]~~|~~ee~~<br>~~fw]~~|No<br>~~ee~~<br>~~fw]~~| ||1 min<br>~~ee~~<br>~~—~~<br>~~|~~<br>~~a~~|0.1 to 1 min<br>~~ee ee~~<br>~~fw]~~<br>~~ee~~|~~ee~~<br>~~fw]~~<br>~~ee~~|No<br>~~ee~~<br>~~fw]~~<br>~~ee~~| ||10 min<br>~~—~~<br>~~|~~<br>~~a~~<br>~~ee~~|1 to 10 min<br>~~fw]~~<br>~~ee~~<br>~~ee~~|~~fw]~~<br>~~ee~~<br>~~eee~~|No<br>~~fw]~~<br>~~ee~~<br>~~eee~~| |H3RN-11,<br>H3RN-21|1 min<br>~~a~~<br>~~ee~~<br>~~ee~~|0.1 to 1 min<br>~~ee~~<br>~~ee~~<br>~~ee~~|~~ee~~<br>~~eee~~<br>~~ee~~|Yes<br>~~ee~~<br>~~eee~~<br>~~ee~~| ||10 min<br>~~ee~~<br>~~ee~~|1 to 10 min<br>~~ee~~<br>~~ee~~|~~eee~~<br>~~ee~~|No<br>~~eee~~<br>~~ee~~| ||1 h<br>~~ee~~|0.1 to 1 h<br>~~ee~~|~~ee~~|No<br>~~ee~~| ||10 h|1 to 10 h||No| The 1-s range and ON-delay mode for H3RN-1/-2, 1-min range and ON-delay mode for H3RN-11/-21 are factory-set before shipping. |**Operating mode**<br>~~ee~~|**Setting**<br>~~ee~~|**Factory-set**<br>~~ee~~| |---|---|---| |ON-delay<br>~~ee~~<br>~~pf~~<br>~~ee~~|~~ee~~<br>~~pf~~<br>~~eee~~|Yes<br>~~ee~~<br>~~pf~~<br>~~eee~~| |Interval<br>~~ee~~<br>~~ee eee~~|~~eee~~<br>~~eee~~|No<br>~~eee~~<br>~~eee~~| |Flicker OFF-start<br>~~ee ~~<br>~~ee eee~~|~~eee~~<br>~~eee~~|No<br>~~eee~~<br>~~eee~~| |Flicker ON-start<br>~~ee eee~~<br>~~a~~|~~eee~~<br>~~a~~|No<br>~~eee~~<br>~~a~~| **Note:** The right two DIP switch pins are used to select the operating modes. 7 ~~rr~~ ~~**H3RN** OROPar~~ ~~**H3RN** Dimensions~~ **Note:** All units are in millimeters unless otherwise indicated. ## **Timers** ## **H3RN-1/-11 Front Mounting** ## **H3RN-2/-21 Front Mounting** ## **Mounting Height** Use the P2RF-j-E or P2R-j7P to mount the H3RN. When ordering any one of these sockets, replace “j” with “05” for SPDT or “08” for DPST-NO. **P2RF-** j **-E** **==> picture [227 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> H3RN Series<br>80.9 (see note 1)<br>P2RF-j-E (84.9) (see note 2)<br>Socket<br>79.5 (see note 1)<br>(83.5) (see note 2)<br>**----- End of picture text -----**<br> **==> picture [36 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> P2R- j 7P<br>**----- End of picture text -----**<br> **==> picture [36 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> H3RN Series<br>P2R-j7P<br>Socket<br>**----- End of picture text -----**<br> - **Note:** 1. The value shown indicates the dimension for the P2RF-05-E with the PFP-jN Mounting Rail. The value is 71.5 mm when using the PFP-Nj2. 2. The value shown in parentheses indicates the dimension for the P2RF-08-E with the PFP-jN Mounting Rail. The value is 75.5 mm when using the PFP-Nj2. 8 ~~**H3RN**~~ **==> picture [55 x 80657309696] intentionally omitted <==** ~~**!**~~ ~~rr~~ ~~**H3RN** OROPar~~ ~~**H3RN** Precautions~~ When using the H3RN in any place where the ambient temperature Do not use the SPDT contact in a circuit which may cause short-ciris more than 50"C, supply 90% to 110% of the rated voltages (at cuiting at three points (otherwise, short-circuiting of the power sup12 VDC: 95% to 110%). ply may occur) because the SPDT contact of H3RN-1/-11 is com- Do not leave the H3RN in time-up condition for a long period of time (for example, more than one month in any place where the ambient temperatureis high),otherwisetheinternal partsmay becomedamaged. Therefore, the use of the H3RN with a relay as shown in the following circuit diagram is recommended. **==> picture [30 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> H3RN<br>G2R Relay<br>**----- End of picture text -----**<br> The H3RN must be disconnected from the socket when setting the DIP switch, otherwise the user may touch a terminal imposed with a high voltage and get an electric shock. Do not connect the H3RN as shown in the following circuit diagram ontherighthandside,otherwisetheH3RN’sinternalcontactsdifferent from each other in polarity may become short-circuited. **==> picture [127 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Correct Incorrect<br>**----- End of picture text -----**<br> Do not use the SPDT contact in a circuit which may cause short-circuiting at three points (otherwise, short-circuiting of the power supply may occur) because the SPDT contact of H3RN-1/-11 is composed of an SPST-NC contact. **==> picture [109 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> 3 ><br>Short-circuit current 4<br>Power supply<br>for load<br>2<br>:<br>1 5<br>o<br>**----- End of picture text -----**<br> Donot set totheminimum settingintheflickermodes, otherwisethe contact may be damaged. Donot usetheH3RNinplaces wherethereis excessive dust, corrosive gas, or direct sunlight. Makesurethat thereis aspace of 3 mm or morebetween any H3RN Models next to each other. (When using the P2RF-j-E Socket, a spaceof 3mm ormorewill besecured.)If aspaceof3mmormoreis not secured, the ambient temperature must be less than 50"C. The internal parts may become damaged if a supply voltage other than the rated ones is imposed on the H3RN. ## **Precautions for VDE Conformance** The H3RN as a built-in timer conforms to VDE 0435/P2021 provided that the following conditions are satisfied. ## **Handling** Use the following safety circuit when building a self-holding circuit with the H3RN and an auxiliary relay, such as a G2R Relay, in combination. **r** s s } | X/a T/b @: H3RN G2R Relay tte Do not touch the DIP switch while power is supplied to the H3RN. Before dismounting the H3RN from the socket, make sure that no voltage is imposed on any terminal of the H3RN. ## **Wiring** Only a load with basic isolation can be connected to the output contact. TheH3RNis amodel withbasic isolation. Therefore, theH3RN and the load will ensure reinforced isolation, thus meeting VDE standards. Insulation requirement: Overvoltage category II, pollution degree 2 (with a clearance of 1.5 mm and a creepage distance of 2.5 mm at 240 VAC) In the case of the above circuit, the H3RN will be in pulse operation. Therefore, if the circuit shown on page 9 is used, no auxiliary relay will be required. 10 ~~**H3RN**~~ ~~**H3RN**~~ 11 ~~**H3RN**~~ ~~**H3RN**~~ ## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.** To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L090-E1-1B **In the interest of product improvement, specifications are subject to change without notice.** ## **OMRON Corporation** Systems Components Division 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 Printed in Japan 0996-2M (0296) a 12
Updated at April 27, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →